Loading...
HomeMy WebLinkAboutBLD99-00663 Final Cabin and Porch - BLD Permit / Conditions - 3/6/2002 MASON COUNTY PERMIT ASSISTANCE CENTER Phone:(360)427 ss70,ext�352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 /—"- Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT _ BLD99-006 OWNER: HAZEL WILKINSON CEIVED: 07/21/1999 CONTRACTOR: ISSUED: 06/16/2000 SITE ADDRESS: 20 NE NORTH SHORE PL TAHUYA PARCEL NUMBER: 223315000057 EXPIRES: 12/16/2000 LEGAL DESCRIPTION: COLLINS LAKE#1 TR 57 PROJECT DESCRIPTION: DIRECTIONS TO SITE: CABIN AND PORCH ENTER INTO COLLINS LAKE FOLLOW COLLINS LAKE DRIVE TURN RIGHT ON SHORE PL THEN RIGHT FIRST DRIVEWAY General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 1 Type of Constr.: 5N Type of Use: SF Insp. Area: 2 No. of Bathrooms: 1 Occ. Group: R3 Lot Size:O Deck: 0 Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: 0 Building:896 896 Valuation: $60,310 1 Buil ing Height: 15 Occ. Status: Unknown Basement:0 Cvr Porch 288 Manufactured Home Information Setback Information Shoreline& Planning Information Make Length: 0 Ft. Front: N 35.0 Ft. Shoreline: 0.0 Ft. Water Body: SEPA?: No Model: Width: 0 Ft. Rear: S 35.0 Ft. Slope: Ft. Shoreline Desi Side 1: E 20.0 Ft. g" Year: Serial No.: Side 2: W 40.0 Ft. Comp. Plan Desi .: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Hosebibs 2 Exhaust Hood 1 Building plan check' KW $568.95 50962 Kitchen Sink 1 Gas Outlets 3 EH Plan Review $50.00 53749 Lavatories 2 Propane Tank 1 Building State Fee MJB 06/12/200 $4.50 53749 Water Closets (Toilets) 1 Ventilation Fan 1 Building Permit Fee MJB 06/12/200 $643.50 53749 Water Heaters 1 Propane Stove 2 Violation Fee MJB 06/12/200 $643.50 53749 Bath Tubs 1 Violation Investigation Fee MJB 06/12/200 $42.00 53749 Clothes Washer 1 Mechanical Fee MJB O6/12/200 $115.00 53749 Mechanical Base Fee MJB 06/12/200 $22.00 53749 Plumbing Fee MJB 06/12/200 $54.00 53749 Plumbing Base Fee MJB 06/12/200 $20.00 53749 Total $2,163.45 It BLD99-00663, Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD99-00663 CONDITIONS FOR BLD99-00663 1) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X ZAJ 2) This application is sub'ect to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036. x 3) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 5) Structure must be setback 'frpm all utility and drainage easements, a total of 10' from each property line, or a variance must be obtained from the Building Department. X 4 Ali 6) Proposed structure or any portion thereof greater than 30" in height from grade line, ust maintain a minimum of 5' setback from all property lines, easements and 10'from all County and State Road right of ways. X 7) All upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given some other equivalent type of protection against erosion. X 8) Approved per dimensions and setbacks on submitted site plan. X KLAr 9) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(minimum 1 hour) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X 4W i �BLD99-00663 Please refer to the following pages for conditions of this permit. 2 of 4 10) - PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. X ky✓ 11) The plan review corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked APPROVED, they may not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply will result in failure of required building inspections. Every permit shall expire by limitation and become null and void if the building or work authorized by such permits is not commenced within 180 days from the date of issuance, or if the building or work authonz by such permits is suspended or abandoned at any time after the work is commenced for a period of 180 days. X— _4 12) The approved plot plan is required to be on-site for inspection purposes. If inspection is called for and plot plan is not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(minimuia ur) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X 13) UMC Chapter 7. In buildings of unusually tight copstruction, fuel burning appliances shall obtain combustion air from outside (excluding cooking appliances and clothes dryers). X 002 14) Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed, approval will not be granted. In addition, a re-inspection fee of$42.00 per hour( i igm 1 hour) will be charged and must be collected by this department prior to any further inspections being performed or approval granted.X 15) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x WA 16) Changes to approved building plans that effect compliance to the 1991 Washington State Energy Code, 1991 Ventilation and In oor Air Quality Code, the Uniform Building Code and/or Mason County Regulations must be approved by Mason County prior to constructionX 17) CONSTRUCTION PROCESS T BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE.x I O IV- 18) If the tank size is between 125 and 500 gallons you must follow these guidelines: 1. Tank is to be 10 feet from any buidling, public way or property line. 2. If the tank is exposed to probable vehicular damage, provide protective bollards 3. All weeds, grass, brush, trash and other combustible material shall be kept a minimum of 10 feet away from LP containers. X W 19) Fuel piping shall be inspected after the installation of gas piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances attached to the piping shall not be used until the final inspection has been approved by the building inspector. BLD99-00663 Please refer to the following pages for conditions of this permit. 3 of 4 20) All property lines shall be clearly identified at the time of foundation inspection. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. OWNER OR AGENT: 14q�� / ,/� �/,QtQ..�,i DATE: — l — 6 b BLD99-00663 Please refer to the following pages for conditions of this permit. 4 of 4 E MECHANICAL MOBILE HOME etback date by Ribbons Jdate G-C>� by Gas Piping date b rz-!. Wallsdate b Set Up by INSULATION date by 1.BG�/SLAB Insulation Floors Final jdate. N by date � �l by date by FIRE DEPT. Idate , --//-v Eby 2,` a els by date by (PLUMBING OTHER Groundwork Attic Idate by date by D.W.V. WALLBOARD NAILING date by date w /7- c" / by �J Water Line FINAL INSPECTION date —/�' by�� date _ G 2 by T/C date by Gf_ G'� ���T/0^� s�/siFrl ,��95-r' .��) �c�i'YG/yc'.�'i7.�✓� Z22 %7't 1 MASON COUNTY 427-9670 BUILDING DEPARTMENT ALL PERSONS ARE HEREBY ORDERED TO AT ONCE TOP , .WORK On these Premises at This order is issued because A.M. Posted P.M. 19 By The failure to stop work, the resuming of work without permission from the WARNING Building Official, or the removal, mutilation,destruction or concealment of this Notice is punishable by fine and imprisonment. � I MASON COUNTY PERMIT ASSISTANCE CENTER Mason County Bldg.III 426 W.Cedar P.O.Box 186 Shelton,WA 98W (360) 427-9670 Belfair(360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 May 12 , 2000 Hazel & Darlene Wilkinso 11403 Glendale- Way-S" Seattle, WA, 98168 Re:BLD99-00663 Dear applicant, Your plan for the building permit referenced above has been reviewed. This review letter contains only those comments related to the building department review and does not reflect additional needs of the other county departments. Please review the following project data, and plan review comments . It is important that you then follow the instructions for re-submittal located at the end of this letter. PROJECT DATA: Owner: Hazel & Darlene Wilkinson 11403 Glendale Way S Seattle, WA, 98168 (360) 275-9593 Engineer: John K. Bastian P.E. P.O. Box 284 Sumner, WA, 98390 (253) 756-1860 - Code Editions : 1997 Uniform Building Code, WAC 51-40 1997 Uniform Plumbing Code, WAC 51-46, 51-47 1997 Uniform Mechanical Code, WAC 51-42 PLAN REVIEW COMMENTS: 1, The submitted engineering does not contain any calculations or analysis for the design of a non-conforming foundation. The inner and outer footings are specified as 12x12 and 16x16 respectively, however no depth of footing, nor depth below grade is specified. 1997 UBC 1806 .3 requires all bearing walls, if an alternate design is not provided, to be supported by a continuous concrete foundation as set forth in Table 18-I-C. If the post foundation is to be used, a full lateral and vertical analysis and design must be submitted showing all load calculations and how all loads, vertical and lateral, wind and seismic, will be transferred to the resisting elements, and be protected from the elements, including ground freezing. s-' 2 , The lateral engineering submitted does not indicate the loading criteria, the building code edition used to establish design load forces, or the seismic zone that the structure is designed for; nor are any seismic load calculations provided; nor is there any statement that would otherwise establish that only wind loads need to be considered in the lateral design of the structure. 3 , In regard to the requirement for the entire floor system to be pressure treated, the 1997 Uniform Building Code section 2306 . 3 specifies, not only floor beams within 12" or joists within 18" of exposed earth that must be pressure treated, but also refers to any beam within 12" or joist within 18" of unexcavated areas located within the periphery of the building foundation. Therefore, the floor assembly, including posts, girders, joists and subfloor, shall be approved wood of natural resistance to decay as listed in 2306 .4 or treated wood, or the . clearances specified must be maintained. 4, The deck surfacing is indicated to be 3/4" OSB. 1997 Uniform Building Code section 2306 . 12 requires that wood structural panels shall be rated for exterior use is used in an exposed application. Porch floor shall be constructed of approved wood of natural resistance to decay or treated wood. 5, The locations of all smoke detectors as required by 1997 Uniform Building Code section 310 .9 are not noted on the plan documents . Please make the required corrections and clarifications and submit two sets of the plans showing the revisions . If only affected pages are re-submitted, arrangements should be made to remove voided sheets and re-insert new sheets into both building department copies of the submitted plans . Please detail all corrections and revisions in a transmittal letter, numbered in the same order as in the plan review letter to *aid in a timely re- submittal review. If submittal documents are incomplete or changed so as to require additional plan review, an additional plan review fee shall be charged at the rate of $42 .00 per hour. Prior to re-submittal, please call the Plans Examining Department to make arrangements for a re-submittal . If a meeting is needed, or if you have any questions regarding this review, please contact me at (360) 427-9670 extension 551 . Sincerely, Michael J Barth C.B.O. Mason County Building Department Plans Examining wp\99-0663 cc:John K. Bastian. P.E. FORM MUST BE COMPLETED IN INK PLEASE PRESS HARD MASON COUNTY PROJECT SITE INFORMATION ��// Case No. Name Adze/ �-bp v-n z 0 r I IC,'nSm1 PARCEL NUMBER Date7 SHOW THE FOLLOWING ON SITE PLAN Show Direction by indicationg N, S, E, W in relation to the sit�e�Ian /�v Lot Dimensions Fences Existing Structures Driveways Structure Setbacks Shorelines / Water Lines Topography Well Location (including adjacent) Drainage Plan Names of Streets Easements Names of Fronting Streets Septic System DRAW SITE PLAN BELOW Include adjacent properties if on shoreline or within 100 feet of adjacent property line. adjacent property line4 I I E-adjacent property line I I I , I -301 3S ' I i4 �tis I I I I I I I I I , I C. Zk I I I adjacent properly line- 1 I Fad'acent property line rIv Q SAMPLE SITE PLAN .adja�t property line � a 3zo� adjacent property line D 3 0 S - — � L &aatsu NaL"rz I j PrioPostD smP*:C- I5 —�I 1 , 0 I I VAG,.,T I T c.ArtAae I 30' I i 1 � D0.oPo�CD R\ •� I� \ T A&R=LLITtJiAL So 1 I I � I I I \ R /DO I I I � c.+...eLL I I I I I /00' I I L�rGLL 1 i adjacent pro ert lined ; a". \i Fad'acent ro ert line TOPOGRAPHY PROFILE(Show a side view of property. Show slopes, cuts and fills. If possible include height and the degree of slopes. See sample topography profile.) SAMPLE TOPOGRAPHY PROFILE I � ructwY� +�.��. d rates►,« *c S1opm c¢ dts+anam 4 0 !_ Signat re Date � _N G� qR_ppt75 (m� PERM INO.: BLD MASON COUNTY �' ' -D BUILDING PERMIT APPLICATION 7`°�'� 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 -- Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 FAFPLIC NT IN RMATION CONTRACTOR INFORMATION OWNr �e.� r At,. r Contractor Name Vol Maili�9, re U Qir. Mailing AddressIV City J State k Zip Code 017 t City State Zip Code Phone c�I%F LO '75gVF3 Other Ph.206 ) Ph.() Other Ph.( Lien/Titl older�i7tn,rx �Lr ke- r Contractor Reg. # Address .O. h Expiration SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic_X Existing Septic Connect to Sewer System Name of Sewer System Well Water System Name of Water System PARCEL INFORMATION-12 digit Tax Parce No. 2 / — / p00 t5 Fire District �. Legal Description (' Site Address(Please include street name, street number and city) D a Directions to site UAX, ns o.K� Will timber be cut and sold in parcel preparation? (Yes/No) Is your property within 200' of the following: Body of Water (Name) Saltwater Lake River/Creek Pond Wetland Seasonal Run ff Stream Slopes or Bluffs TYPE OF JOB Newer_Add Alt Repair Other Use of BuildingV Describe Work No. of Bedrooms =�. No. of Bathrooms_SQUARE FOOTAGE-1 st Floor_1 9 4 2nd Floor ,9 3rd Floor Loft Basement , Deck Other o t 'Gh sq. ft.� Garage Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make del Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unfit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. r QJX Date �"'�9 -1 X Date FOR OFFICIAL USE BEYOND THIS POINT )Cr Accepted by Date Submittal Amount Dueaj—LORec4ipt No.Qfj DEPARTNTA�.'RVIEW APPROVED DENIED '' CONDITION CODES Building Department MSt3 Occ Group 3 Type Constr. SM 6 4' Planning Department Environmental Health Department Public Works Department I Fire Marshal Valuation $ .. FEES. Building Permit Fee 3.SO Site Site Inspection • Plan Review Fee _s ;b7 UFC Plan Review Fee Plumbing & Base Fee y oQ Public Works Review Fee Mechanical & Base Fee 13) , 3 ,OO Other �� L{ so Wood/Gas/Pellet Stove Fee Other Violation Fee �3. C� O Pre-Paid at Submittal ::::::i:}:$:4i'r.'•iii$t::::ii::i::::i:::::::::::t:::yy:::i:::iii::i:;:;r+::i>Liiii'"'i!:F'�>:: +::$::::'Y;:iii:•i:;}:"^i:G':•::i:•iii:..... ..............,.:,;:•:.:.::::::::::. w«Y...:....:............... .:...:::::::::::::.r.::.:...:. TOTAL FEES D pair- ;- n 7-2-77 1 G,V Zp cow vr�Ti=O JT ofI/�G-L, ?v /9-3 ' ,� ■ �� air b,�IPc�ml�in�� o v?o �I�4S,�m�G- /G;xz�fi STGY/gG� �(3�i�,0��✓G-