HomeMy WebLinkAboutBLD2026-00806 - BLD CD Environmental Health Review - 9/29/2026 *NOT AN APPROVED SEPTIC DESIGN*
Use approved septic design for septic system installation N
Proposed Water Line
1002'
/
/
Slope /
xistin Parkin and Dr' ° /
eway
��o loxio decks at front and rear entry doors // //
rZ 248' 696 / /
cn_
NProposed 3 bed 3 bath manufactured home // /"/
Zepficmay need •/ /
be pgraded to /
ump system if fall ! 1
can not be obtained 1 1
1043'
Reserve drainfield area per
Note: A revised septic design or a tank-only SWG2023-00348
permit will be required if a pump chamber or
pump basin is necessary due to the
residence's new location.
EH SETBACKS
A)Drainfield/Reserve requires 10 setback from footing/foundations
B)Septic tank(s)requires 5'setback from all foundations
C)No foundation/perimeter/curtain drains within 30'down-gradient or 10'up-gradient 0 100 200
of drainfield or designated reserve drainfield area
D)No cut(s),bank(s)(greater than 5'&over 45 degrees)within 50'down-gradient of
drainfield/designated reserve drainfield area EH APPROVED Scale 1"=100
E)No septic components within 10'of pressurized water line(s).Sewer transport line
may only be within 10'of a pressurized water supply line if approved by the local 3-bedroom SFR
health officer and the line is constructed lAW section C1-9 of the DoE"Criteria For . Anderson 09/29/2026
Sewage Works Design".
REVISIONS
DRYER, CHRISTOPHER MM/DD/YY REMARKS
961 NE TAHUYA RIVER RD ii...
TAHUYA WA 98588 Z
3 -- -- ...
Parcel 3221275OO1OO 4
5 -- --i-- H.