Loading...
HomeMy WebLinkAboutSWG2026-00222 - SWG Application / Design - 9/3/2026 ® MASON COUNTY 4t5N6 SELTON 30427970EXT400 SH STREE ,SHE TON,WEXT400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMa.360-092-5269,EXT 400 FAX:360-427-7797 On-Site Sewage System Permit: SWG2026-00222 APPLICANT PAULA JOHNSON' Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 OWNER APPLICANT EMPIRE HOME CONSTRUCTION LLC Phone: 360-751-8062 Address: PO BOX 241 KELSO, WA 98626 SEPTIC DESIGNER PAULA JOHNSON* Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER ALLAN KIRK* Phone: 360-426-0574 Address: 30 E WILCHAR BLVD SHELTON,WA 98584 Site Address: 361 SE RYAN RD Primary Parcel Number 319055000013 Permit Description: New 3bd ATU to pressure trench Permit Submitted Date: 07/17/2026 Permit Issued Date: 09103/2026 Issued By: Rhonda Thompson Current Permit Fees Paid: $570.00 (addumnarree,may de,Rau„ed upon installation of system). Permit Expiration Date: 09/02/2029 (based or dale ofinspection) Permit Conditions: 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 7 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF 055. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call; 360-427-9670, extension 400. OFFICIAL USE ONLY MASON COUNTY tSESi,:. 07 l7/c a Ud 41.womTawEz I racE. =_a av W Public Health & Human Services L j ' 7C inli Environmental Realm 360-427-96'0,ex:.400 or 36O2fi-446],ert.100 SWG _ O 4',S N.6th Street- Shelton,WA 9658: Z rn ON-SITE SEWAGE SYSTEM APPLICATION m M EP L>E cPPL pi "- (360)751-8062 Empire Home Construction [ II � 3 N4iLINGA]]RESS GSREE CIT".S n.E.ZIFC0^✓_ �I` N Kelso WA 98626 m P.O. Box 241 o �!I a z RITE AOGRFSR.STREET.CITY Z P CODE o c Shelton WA 98584 36)SE Ryan Rd E' NAME G:NISIG4ER P OM1c 360 Arrow Septic Designs, Inc (360) 898-2255 m I � rvAlsz C=Insr.:,.Lsa —I r� T G RESMason County Excavating -- _°? (360)490-3144 N I o PER E ed Pro. J HNG t , RROVR _ Q _ _ PRIVATE Two-PARTY NR__ Z O1 TYPE OrV RK(se!TIAL 05$ �GGMMUNIT:'G95 �GOMM5RLIAL QS IT PUBLIC WATER SYSTEM OPWORR(se'T.'Gne) NEW CONSTRUCTION I UPGRADES EREPrPY,REPLACEMENT O . R DETAiLSING S '-..P" ❑ TABLE XREPAR ❑ SURFACING SEWAGE GE ❑ EXISTING AI URE ❑5 .CRELINE SUBMIT'_R G- g O DESIGN FORM(REOJ,REC) SE?TIC DESIGN(R DUIREO) BE^.ROO!n5 'A R.ZE V .-T - iEDA1T 3 /1GY51 p 3 6 BR 1.0 ac ❑ YES a NO P WAIVER(S) APPUOABL;' DIRECTIONS TO 5:T2 AND 575 CONCLTO.IS(er mceo;2) Head toward W Alder St and turn (R). At the traffic circle, take the 1st exit and continue onto N 1st St. Turn (L) onto the US-101 S ramp to Olympia. Turn (L) onto SE Ryan Rd. r o Destination on (L). Green/white "361" on tree by slab/parking 'N SITE MUSTSE FLAGGED FR OM MAIN ROAD AND TESTHotES MUSTRE FIAGGED WITH TESTHOLE NUMBERS. W I W OFFICIAL USE ONLY BELOW THIS LINE UPGRADE I FAILURE SOURCE'Jcr repa'N9 Wrp ses ❑VOLUNTARY ❑MAINTENANLE'PIJMPING ❑BUILDING PERMIT ❑HOME SALE ❑COMPLAINT ❑OTHER. CGMMENS ILOND.TCN5 INSPECTOR 601LOGS [ -f 1 � (p fi - mote \\ RECORD DRA'VP..NG AND INSALLC ON PEFOR- SOIL CODES; =VERY G=GRAv'c1Y s=SAND C-LOAM Si SILT L=CLAY E=ExrONDATE a=ROOTS REBuwEOFORFNF IADSY SAPPLICATION APPROVED;ISSUED 3v DATE INSpELYOR 6IGNATVR= OFTE 'A�PL GTIOtt EXPIRATION DATE cOMTHIS FORM MAY BE SC NNEO AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE Revised:411412025 DESIGN FORM—PACE ONE Assessors Parcel Number: 319O I — 5 0 — 0 0 0 1 3 A design will be reviewed when 3 copies of each of the following are submitted: a Completed design form that has been signed and dated. 'Scaled layout sketch,including all applicable items on chzcklisi_ e Scaled plot plan. including all applicable items on checklist. , Cross-section sketch. including all applicable tems on checklist This form may be scanned and available for public view on the Mason County Web site.MaxJmurn per size: I7 k I fern Permit Number: ,\ Dzvener s'Sam Are: ow 5 pic D q Inc o- Sk1G -__ (7�� `. -OT} 360 698-2255 Empire Home Construction Designers Phone Number ( ) Applicant sCame. __._. . -----— _ 171EVuecrest Dr P.0 Box 241 Dzslgner s Address: Mailing Address: orate LID Union, WA 98592 S Kelso WA 98626 tl aula hctc com City State zip Designers Email pj@ .com Treatment Device ❑ C I i-ion ❑$arid I •.ter ❑ Mound ❑ Sand Lined Drain field 0 Recireciating Fil[cr D AT'.. NUwater ena-500 U Other Treatment Level(cheek all that app I;): ]A C H DC ❑ Ill I E RI 2 21 BLS 1 1: EN Drainfield Type ❑Graoity Pressure li Trench ❑ Bed ❑ Sub Surface Drip Septic TanklDraintield Specifications Laterals lumber of Bedrooms 3 Schedul&Class 40 Daily Flow: Operating Capacity 270 gpd Length 50 ft Daily Flow: Design Flo, 360 gpd Diameter 1.25 in Septic Tank Capacity(working) NuWater BNR-500 ual Number 3 Receiving Soil Type (1-6) 3 Separation 5 ft Receiving Soil Appl_ Rat, 0.8 gpd.'ft- Orifices Required Priman' Area 450 ft Total Number of Orifices 30 Designed PrimaN Area 450 ft2 Diameter 3/16 in Designed Reserve Area 600 ft' Spa,iu_ 60 in Trench/Bed Width 3 ft Manifold Trench/Bed Lengh 150 ft Schedule'Class 40 Elevation Measurements Length header ft Original Drainfield Area Slope 5 % Diameter 1.25 in Nev Slope.If Altered 5 % Preferred manifold configuration used? fil Yes ❑ No Depth of Escavzdon H—mope 10 in Transport Pipe from Ori__inal Grade Du>`n-shpt 8 in Schedule'Class 40 Designed Vertical Separation 12+ in Length 50 h Grata)-based Drainfield Required? ❑ Yes ML No Diameter 2 in Pump Required? 9 Yes O No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses'dev 4 Diff.in Elevation Between Pump& Cppcmhost Orifice 10 ft Dose quantity 00 car Drainfield Squirt Heights Selected Residual (head) 2 h Chamber Capacity(flood) 1,000 gal Uppermost Orifice Higher ❑ Lou er than Pump ShutoffPump controls:Please check those required. Capacity @ Total Pressure Head 17.7 gpnt Timer ❑ B'apse Meter ❑s�rv,nr Counter Calculated Total Pressure Head 13.23 g It 'timer: P t s p off 6 hours Comments J ' t C o —( O Revised: 4'14/20225 TV 'DESIGN FORM—PAGE TWO Assessor's Parcel Number: 3 1 9 0 5 - 5 0 -- 0 0 0 1 3 Permit Number: SWG Dpi - DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch Test hole locations (Z Drainfield orientation and layout Reference depth from original Jade: 96 Soil logs Trench/bed dimensions and l66 Septic tank $6 Property lines critical distances within layout V Drainfield cover � Existing and proposed wells D-Box'Valve box locations Reference dzptb. @om original grade within 100 ft of property E6 Septic tank/pump chamber and restrictive strata: Z Measurements to cuts.banks, and locations Gd Laterals, trench'bed,top and surface water and critical areas 9 Observation port location bottom ❑ Curtain drain collector ❑ Locain n and id all bn of Ed ManifClean- ld n ❑ Sand augmentation curtain drain and ffi! absorption � Manifold placement components fd Orifice placement Other cross-section detail: 9 Location and dimension of G1 Observanon ports'clean-outs Lateral placement with distance primary system and reserve area to edge of bed Other Information 9 Buildings Audible/visual alarm referenced Yes No 0 Direction of slope indicator l[0 Scale of drawing shown on scale d ❑ Design staked out 9 Waterlines bar 0 Et9 Recorded Notices attached ZT Roads, easements. driveways, p Elevation benchmark and relative ❑ I56 Waiver(s) attached parking elevations of system components +� D Pump curve attached ib North arrow and scale drawing 0 9 Evaluation of failure shown on scale bar I Non-residential justification ❑ r]6 Waste strength Q 'bt ij. 0 E1 Flow DE �.l The undersigned designer must be notified by i r t nsra}I t4p,n Et Yes ❑ No q JOHNS . .iC lS1a C5i6NCp' j} _ I b—tea Signature o esrgner - -- - Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regclalions: En vironmentalntal Health Speci list Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped Approved'by Mason County Public Health. I� rZG ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: (� 1 ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Revised: 4/14,2015 2oir-(O ,I ¢ 5 Osb4 :I— a z a -ti T z `1 n: Ut 9 et 8 �1 4 i QE83 -' Y : r Q S � . z - ,� Gale , } -•• zQ F 3 8 2 \ II a \ _ n�u��gn gyulr�g-�r yry 00 NOSVW 4£Z9tiZ uts:S,� KCi•+L CSf� ]` 7y~ Y \ l� - ₹ N . T- r� proY - 9 `` lb / rtm o • 11 ' -Jsm ' -T2 �� cz C — : i c n z,oco cz� ? c' ,�- £S =r_59 � ic;` - v Vale Coa*ro13ae S. � - � vsa ¢�i '�4- 1 •r rte_.,L3s4 L6 s ice— t' C- y {v".. 1*. e•. .2l s_ — '.N , **Note to installer' Sleeve waterline when within 10' of se tic trans or[ line. Maintain PhU[A JOY JOHNSON ''l P P SEtl Si6Nt ]0' minimum between water ��� Zb r� q �.fbt �Q line and septic tanks/drainfield. C. - jeq-� Cr I q�i2Xao� +e_..�eis`r z '� wd a O l r __ Wes_. \ 7 JSPAULA JOY JOHNSON • u3 2LH orny LflcT ...ex_ -- . SCREW ON CAP NOTE 6" 1` )8" 24 d5 DEGREE ELBOW OR O=OBSERVATION PORTS--TO BE 4 " j LATERALSWEEPING 90 GRADE. PIPE FROM BOTTOM OF TRENCH TO FINISHED REMOVABLE END 0F^ CAP SHALL BE INSTALLED ON DITCFl DETAIL OBSERVATION PORT PIPE. GLUED ON CLEAN OUT TEE AT BOTTOM.. IN SYSTEM. MINIMUM OF 3 NOTE, CLEANOUT TO BE FROM D TO 6 LATERALS ARE TO BE CENTERED- INCB£5 BELOW FINISHED GRADE- MARX ENDS WITH REBAR. CLEAN OUT IN TRENCHES REQUIRED AT END OF EACH LATERAL. ' END MANIFOLD (600" ) 50 ' TRENCH o ORIFICES) ORIFIROS MANIFOLD1f 3C FROM MA 300FROM ELBOW , ça - uo Length Length Orifice # Distance from Distance from Lateral# (In.) (Ft.) Spacing Orifices Feeder Line (In.) Cleanout(In.) 1 600 50 60 10 30 30 2 600 50 60 10 30 30 3 600 50 60 10 30 30 Total Lateral Length 150 Total#Orifices 30 GPM = 17.7 Dynamic Head Calculations Selected residual pressure: 2 ft. Length (Ft.) #Orifices Transport Pipe 50 30 0.29 ft. Feeder Total Lateral Line Length Lateral#1 50 2 52 10 029 ft. Lateral#2 50 7 57 10 0.31 ft. Lateral#3 50 12 62 10 0.34 ft. f Total Elevation Lift 10.00 ft. 'v �r ur Total Dynamic Head 13.23 ft. r • v H ;�/tr APPROVP.: n A . R PAULA JOY JCHM1SON 1 [j j 2LLICEYJf�Etlt}E$16NFk- l-k'O"T' SECURED UD WMN GAS 7KNR SEAL THREADED UN(ON 24-D4AWT ACCESS RISEA VacE FIRM GRADE -- TO ORAR4FRID - FROM SEPTIC TANK STORAGE ANTILVEION MON WATER ALATMI LEVEL. DN)EP61DE11T NORMAL TITER OFF LEVEL FORFLOAT ENCLOSED PUMP CHECK VALVE' SEDIMBFfSHROUO• - _ .- _ SEOIMEN78 y_=:In I.II cetrtRWLIaAL ..---"— PUMP ' - PUMP CXAY@EB [Typ CLLI . AS NEEDED Septic Tanks must meet standards required by WAC chapter 2a4g6-272C and FIGURE 2:. manufacturer must beoon Dept of Health list of registered sew a tanks. w...tc nffi5 - ,qf- 4Y Bronze construction available(139 series) High head version available(145 series) Double shaft seat versions available for added protection on models 140/145. Flow-Pilate For more information,see Technical Data Sheets FM2782,FM2783. In high head dewatering or effluent applications where pumping , a POuoNwctcux+r performance is critical• this robust �' „Ove„nnro,r, family of pumps is known for reliability, durability and performance. These pumps are especially suited for harsh environments.Zoellers cool run design and corrosion-resistant powder coated •i epoxy finish add up to a long-lasting, trouble-free product. •�° APPLICATIONS: • STEP or onsite applications i • Watertransfer �. • Light commercial dewatering Th jI SPECIFICATIONS: cS �! 1-1/2"NPT discharge 1/2 HP through 1 HP �A MAOE IN THE USA Available in automatic or non automatic YSaeAYL6P.la1 YIOIIih ,r • Model 137,139.140:1/2"(12 mm)sphedca1 solitls Ofl 1 f r. r- ff � capacity with vortex impeller �"� P 9 I " 1 J ta¢ • � r - Model 145:3/4"(19 mm)spherical solids capacity with vortex impeller [ P 03 2; l - is PUMP PERFORMANCE CURVE MODEL 157/7511153 Dose-Mate er This is our fastest growing line of effluent 1` s Sao pumps.The 150 series is truly a workhorse designed for reliability under extreme ,l conditions in an effluent environment. as 15oseries pump curves cover a wide range m of applications. They are welt suited to ao - ...._c _ applications with tow pressure pipe(LPPandenhancedflow5TEP systems.Zoeller'scool run design and corrosion-resistant,powder coated epoxy finish, in addition to the hermetically seated, oil-filled motor uand non-clogging vortex impeller add up to a long-tasting,trouble-free product. 10 APPLICATIONS:STEP or onsite applicationsMAOE IN THE USR Light commercial dewatering ILYE4UYRIROIUI[OIII11 ALLo; 5 T o ao me z ae ao oa a oo ax ¢e SPECIFICATIONS: n a rLow PER MINLTh 014508 • 1-1/Y'NPT discharge • 3/10 HP through 1/2 HP S • Available in nonautomatic or with a variable level piggyback mechanical switch • 1/2 (12 mm)spherical solids capacity with vortex thermoplastic impeller For more information,see Technical Data Sheet FM2784. O All rights reserved. ZOELLER PUMP CO. 1 502-778-27311800-928-78671 zoeLerpumps.com 9 14- lo 9r DUAL?ORT AERATOR-, RIIETYP) 1\ LID VEN!(p ) RISERS((YP) 3s MNL S . "T IG-PVCI )) SS T '/' AIRLINE' NTSTIC rCOUPLINSIF B RMUCER 6- } Y TEE 1; PPVOSLUDOE REURN LINE PVG TRASH CHAMBER DIGESTER CHAMBER CLARIFIER JPFRATING OACrTY 490 0G LLONS WER OD CAPA ACR494 G.LLONS CHAMBER FLOOD CAPACITY. GPI!ONs FLOOD G?PACRY:L9c GALLONS 160 GiLON5 ROOD 191 GAL ;' Ia �,T Qv jF D • �f 1 e _° 0 ' 23.:0 - OIF U -TO T (21 PARALE-RU TANK WALL I . 3' SLUDGE RETURN 1r TER -ff l • § €]fll 1 1.4 It STONE-FREE NAPVESOIL. OR COMPACTED SAND INSTALLATION INSTRUCTIONS OVER STONY SOIL 1)ExCBNale tank hole with vertical walls 10 1 foot larger than tank On all sides. 2)If boltom of hole is slnny,install 3-of compact sand&level ,' 9'-2' -- Out vith screed. 3)Install tank in center of hole,keeping I t void space on r r all sides. 2L•RISERS�vp 3< BLOWER 4)As lank is filling with water.fill in void space with mmpact I WSINGGST granular(sandy)soil free of large dumps of day. I /^\\ TOF CPU 5)Install rest of system,&affix risers to adapters with / 1 / weterprooladhesive. 1 1 5)Fallon,Waterdghiness test in field as required by local i ) jurisdiction. 7)Upon approval to backfill,carefully backfill with native tY RISER soilsaver top Oftank. i fASH CM4MaE JD/ Nye$ InABIFIEHI 8)Final grade the surface t0 avoid cheneling surface watertoward tank. I ----- --- - - -- -- ---- 1 EW r=2ea AEROBIC TREATMENT TANK DETAIL FOR Nu WATER BNR-500 TREATMENT UNIT ENVIRO-FLO, INC. RE,rrs�: 3/01/12 Wastewater 7reatinent Tedmologies P.O.BOX 321161,Flawoad MS 39232 (877)836-8476 (601)8454716 fax sca-r:: ..enviro-Ao.nst 1 rr _ 1.4 ft. , 0� t0 Nu Water i I ' j \ j I � I PARTS LIST NuWater NR Assembly Diagram A DUAL PORTAERATOP U.POLYOffFU6EREAR21 3.316 RUSSER Sr WICLAU $(2) N.1-PVC(31)7 SECTOR C.3T BARBED AOAPTOft%1.m NPT(2; 0.'.-SUPCAP 017$UP X 1?NPTAOAPTOR P. t/5 CLEW PVC 1105E(OPTIONAL 5) a r StREET x lit NPT BUSHING(3) O.1/2 PVC PIPE IB?ICALLER) ^ 7' ry5 r P 1)2 PLSOW(2) R.••PVC PIPE(BY IHVALLR) 6Ja •I y £ G.1XIXl2•TEE S.TPVC PIPE(BYIHSTALLER) /�. /jJ1i 4.l-so•ELEOW(S) ,.,/o-aARaEDAOWTORTo1/a NPr pJ L U3 7 TX I-BUSHING u.12'STREET x vi•IIDr BUYING c2) A.T sNgrmRymE 11.1-IC COUPLER m - . . K 1.PVC CROSS W?CCUPLER(ST INSTALLER L 1-COUPLER(BY WSTALLER Revised 2/25/12 C10 U a.4wu. Septic 1Oeoigna, Sue. �' �� NuWater BNR Pretreatment INSTALLATION & MAINTENANCE Pressure Distribution Systems N2.. PAULA JOT JOHNSON . t 'iC�FISEtl. K�5�-6�Ng1A 1. Install Laterals with contour of the ground. 1-I 2. Install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock, (do not glue), after pressure test and Environmental Health Dept. approval, turn orifices down (6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade, run the filter fabric at least 2 inches down the trench wall. 11. Waterlines must be a minimum of 10' to any tank or drainfield (a reduction to 5' may be obtained with a State waiver on lots that meet minimum lot size). Encase all water lines within 10' of septic transport lines and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system. 13. No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14. No vehicular traffic over drainfield area or tanks. 15. Inspect floats, clean filters, and test high water level alarm every 6-12 months as needed. 16. All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19. All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8" hole drilled in the discharge pipe above the pump to prevent siphoning. Ensure anti-siphon hole sprays down/away from tank opening. 20. All transport lines under driveways or parking areas must be encased to prevent crushing. 21. Homeowner is responsible for all property lines and easements. 22. Please Note: When you begin using your septic system. contact your septic installer to discuss setting up a schedule for your required your NuWater pretreatment system. /4 fit'`' �" 1 '