Loading...
HomeMy WebLinkAboutSWG2026-00267 - SWG Application / Design - 9/9/2026 ® MASON COUNTY 415N6THE 0 LTON36 -427 96 EXT400 sHSTREE 360-42TON, EXT400 BELFAIR'.360-2754467,EXT 400 Public Health & Human Services ELMA'.350-492-5269,EXT 400 FAX'.360-427-7787 On-Site Sewage System Permit: SWG2026-00267 APPLICANT BUCHENAU DIRK H & KELLY H Phone. Address: 1291 W GALLAGHER RD SHELTON, WA 98584 OWNER BUCHENAU DIRK H & KELLY H Phone: Address: 1291 W GALLAGHER RD SHELTON, WA 98584 SEPTIC DESIGNER PAULA JOHNSON' Phone 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER SHANE MAPLES' Phone: 360-463-8474 Address. 911 SE Arcadia Road SHELTON, WA 98584 Site Address: 1290 W Gallagher Rd Primary Parcel Number: 420314400020 Permit Description: New SFR 3-bedroom NuWater BNR500 ATU with trash tank and trench drainfield Permit Submitted Date: 08118/2026 Permit Issued Date: 09/0912026 Issued By: David Anderson Current Permit Fees Paid'. $570.00 (additional fees may be required won maaIIa;ori of system). Permit Expiration Date- 08/20/2029 (based on date of Inspection) Permit Conditions: 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained 4 Drain field installation not to exceed designed ups/ape and downs/ape depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to back ill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF 055. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. MASON COUNTY 4,5N6SHELTON B"ELTON EXT400 BH STREE 360-42TON EX 8584 BELFAIR'.360-2754467.EXT 400 Public Health IN Human Services ELVA:360-482-5269,EXT 400 FAX-360-427-7787 7 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USF ONLY MASON COUNTY C N nNDLrv-.ucaveD. eEc Ive"e•. � N Public Health & Human Services �7 s y E I HCBNNT D l. O.x:.40L N O L ,el-sl, l —WAPR � SWG �s lG1 z On ON-SITE SE GE SYSTEM APPLICATION ' DO !D Dirk & Kelly Buchenau [LJI (360)463-8713 STATE 1291 W d ODE Gallagherg cZ1 Shelton WA 98584 S iTE ADDRESS STREET C TItP CODE "-L 1290 W Gallagher Rd I Shelton WA 98584 I a NAME OF DESIGNER - P"ONE IN Arrow Septic Designs, Inc �I (360) 898-2255 NnM WP'NSOLLJ3 ___ '� O Maples Excavting (360)463-8474 m w ITI RESIDENTIAL USE F1.COMMUNITYOSS 4 l COMNERCiALOSS 0�+NPRIVATE INDIVIDUAL_WELL ff PRIVATE TWO-PARTY WELL $ PUBLIC WA-__R SYSTEM TVgE'DF R`iN s—, .l p;.NEW CONSTRUCTION!UPGRADES REPAIR!REPLACEMENT O- S iSD. c--' aIimas app"TI ❑ TABLE X REPAIR a SUBMIT f LS 0 SURFACING SEW1 E 0 EX-STING FLU. - 0 SHORELINE p J mr a p La -ESGM1 FORM"REO 'REO) MJ.SEPTIC DESIGN(REQUIRED) E � C 524 a J CREATE: 4n FeL'L'T C)Ly WAVER($)UFAPPLIOASLE) �3 BR 1.80 ac ❑ ES ❑p No o DIRECTIONS-O SITE.AND SCE CONDITDNS fe, i'k 9PT„ Head toward W Alder and turn (R). At the traffic circle, take the 1st exit. Slight (R) onto S O 1st St which becomes W Cloquallum Rd. Turn (R) onto W Lost Lake Rd. Turn (R) onto W r I CD Gallagher Rd. Destination on (R). Yellow sign: "Buchenau". Before green house #1291 on (L) N SITE MUST SE FLAGGED FROM MAIN ROADRNDTEST HOLES MUSTRE FIAGGEDWIiN TESTHOLE NUMBERS. 0 — OFFICIAL USE ONLY BELOWTHIS IiNE— UPGRADE/FAI URE SOURCE Jor rspo-T p4csesl ❑VOLUNTARY 0 MAINTENANCE/PUMPING 0 BUILDING PEEMIT O HOME SALE ❑COMPLA'NT 0OTHER. INSP=CTOR SCI_LOGS IN_N....J..VC. lye. TI1 c'- lq" I1 is (Type 9) �5t ar rf" 4lmal ConnP ffj'd ' 22r. �S( r2254- CI z u/ mof q Ccrnp. r ; O'Lt ' E31 A F LZ" v.C met(( Crnhp1 RECORD DRAWING AND n'STALL.-ION WEPORT SOIL CDDFS: R"__R FL FN'LUPP2GJ?_ VERYo GRAVE- S-SASS: L=LOAM S1=SILT C=CLAY E=EXTREME\ R=RCOT5 E SF TOP DNATJRE DATE APF'_CA ON EXPIRAT or D45 A'PLIC N ROVED;IS LE aI AA �/� aotd I gl ZO 2oZ Y THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE RevISed'4/142025 DESIGN FORM—PAGE ONE Assesso-s Parcel Number: 4 2 0 3 1 - 4 4 - 0 0 0 2 0 A design will be reviewed when 3 copies of each of the following are submitted: .Completed design form that has been signed and dated- Scaled layout sketch, including all applicable items on checklist. Scaled plot plan, including all applicable items on checklist. 'Cross-section sketch, including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site. 1f paper size Ii i f ,. ".n`iw- ,F``-M - rtt4 n'ki:. ...:1'' __ K .._�_;* ,.. ,r.2 -..`na __ ,:f •, -. Desim er s Name: Arrow SeDhc Desi ns Inc Permit Number: 5\\G �-L��CX� p� 360 898-2255 Dirk&Kelly Buchenau Designer's,Phone Aprobe, (360)Applinc AddctS ress: - Vuecrest Dr 1291 W Gallagher Rd Des gnat=s Adders. Mailing Addressc - - Union WA 90592 Shelmn. WA 98584 City State Zp Cue State Zip g au Designers-;mail . la Jhctc Com .D. Treatment Device rouwala-auasoo I!I Othcrs0cyai pre.trash J JAA on ❑ S San 0 . nJ ❑Sand i ¢d Jmi,. dd ❑ R uadrgltacr DA'Il, Treatment Level (-hock oil tnat a d)): 0 ' u B ac ❑ 9LI C BL 2 71 RI? 71 F Pl Y Drainfield Type 0 Gravity Pressure 17�Trench ❑ Red ❑Sub Surface Dr!p Septic TanklDrainfield Specifications Laterals Number ofBedmoms 3 Schedule'Class 40 Daily Flow: Operating Capacity 270 gpd Length 40 ft Daily Flow: Design Flow 360 gpd Diameter 1.25 in Septic Tank Capacity (working) Nuweter BNR-500 gal Number 5 Receiving Soil Tvpe I I-6) 4 Separation 9 ft Receiving Soil App]. Rare 0.6 gpd/ft` Orifices Required Priman Area 600 fir Total Number of Orifices 40 Designed Primary Area 600 ft' Diameter 3/16 in Designed Reserve Area 600 f1` Spacina 60 in Trench:Bed Width 3 ft Manifold Trench Bed Length 200 ft Schedule/Class 40 Elevation Measurements - Length header ft Original Drainfield Area Slope 3 o Diameter 125 m New Slope. If Altered 3 o Preferred manifold configuration used? fidYes 0 No Depth of Excavation U-=lope 9 in Transport Pipe from Original Grade Dt.+.n-dope 8 in Schedule-Class 40 Designed Vertical Separation 12+ in Length 480 ft Gravel-based Drainfield Required? ❑ Yes eNc Diameter 2 in Pump Required? V tes O No Dosing and Pump Chamber Pump/Siphon Specifications Number of dosesldap 4 Dill-in Elevation Retween rump& Lppemtos:Oh ace 10 11 Dose quantity 9n gal 2 Chamber Capacity flood) 1,000 - gal DI'ainfield Squirt Heigte Select p�ed Residual(head) ft Y 1 ) Cap Capacity Orifice Hire ❑1ower than 60 shutoff _ Pomp controls: Please check those required. Capacity�g Total Pressure Head 23.80 gpm t� Timer ❑ pse Meter CJ�vene Counter Calculated Total Pressure bead 17.89 ft If Timer: Pump on 2 min .Pump off_ 6 hr Comments Revised 4114?025 113 DESIGN FORM—PAGE TWO Assessor's Parcel Number 4 2 0 3 1 - 4 4 -- 0 0 0 2 0 ,1r .- Permit Vcmber SWG ` "`-��s..��d-�1 DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch Test hole locations Gd Drainfield orientation and layout Reference depth from original grade: 0 Soil logs Trenclt'bed dimensions and 9 Septic tank 2 Property lines critical distances within layout [tZ Drainfield cover � Existing and proposed wells 1)-Box/Valve box locations Reference depth from original grade within 100 ft of property RJ Septic tank/pump chamber and restrictive strata: ❑ Measurements to cuts,banks,and .ocations Id Laterals, trenched,top and surface water and critical areas &I Observation port location bottom l[ i Curtain drain collector 671 Location nd andd orientation l of' 9 Clanirodt n O Sand augmentation curtain drain and all absorption [yj Manifold placement components [9 Orifice placement Othcr cross-section detail: 0 Location and dimension of 9 Ohsenation ports/clean-outs C� Lateral placement with distance primary system and reserve area to edge of bed Other Information 66 Buiid.ng l9 Audible/visual alarm referenced Yes No l6 Direction of slope indicator 9 Scale of drawing shown on scale d ❑ Design staked out 9 Waterlines bar ❑ E6 Recoided Notices attached R1 Roads,easements.driveways, p Elevation benchmark and relative ❑ tRf Waiver(s)attached parking elevations of system components l[Z O Pump curve attached � North arrow and scale drawing ❑ Cd Evaluation of failure sho•.vn on scale bar _�. Non-residential justification ❑ 66 Waste strength ❑ 9 Flow fir' 32OVAL a.? r The undersigned designer nast be notified b' iSllt irNe.,gnsmllation Yes ❑ No 2r , a ie " 41Z Signal e of MMWDa1"n- Date u The undersigned has reviewed this design on behalf of Mason Count Public Health and determined it to be in compliance with state and local on sir egu rions: "-_n r Dtv.ronmertal Health Specialist Date CAUTION; DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOR'ING CONDITION: ✓ The dest n is stamped Approved by Mason Count Public Health. a.) �� V The Gnsite Scy:age Permi has not expired. ,he Permit Expiration Date is: (/ ✓ Drainfield site conditions have not been altered to adversely affect conditions ofdesign approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form maybe scanned and available for public view on the Mason County Web site. Revised:4;14 ?0?5 2�3 k- 'Pro j. ®' $\ �� w. �S, QLD' P6AN Ali Di R.K. t- 11E UL 111 �niAU ?RCEL � 42cb1 44 boDza d t2ge WGALLPtG$£(L RD Lfl v 9$554 (� j dj l*1��'"^• �2 ' b-�Z S� To r-ccs[t-! Dsv-iP 9 3s3 :D-21," SL�zI- 3G `CP c-OPrtcc"�o-43 DAraP B W ` sESEQ.yE era &wSEN hJ ` I 0 A1Z0-Vi$uai?farm OC_eanolit ✓1 S I U 500 Gallon Pre-Trash tack }� +� 0 NuWater BNR-500 ATILT Tank ® O 1,000 Gaon Pump Chamber 4alve Control Box **\ote to installer"* sleeve waterline when within 10' a O of septic transport line. Maintain 10' minimum between water 14D' Xsb, ly line and septic tanks/drainfield. �e€o pesw� tiP OF ypid 'a 1. 1 ��' PAULA JUY J0M95JN � 1 3D 3 - fSrDUE5i,Nta'" EXHIBIT C (NEW SCALE: 1"=200 F FOUND 314" I.P. SOUTH 0_57, & WEST 0.13' OF 0 100 200t ( ' 00 CALM POSITION S 8996'30' W 66,5.87 661.51 PARCEL t42031440000 S OUND 3/4' I.P. LINDA IN AM SOUTH 1.40, & 1291 W GALLAGHERER RD. 'n'� EAST 53.25' OF SHELTON. WA 4 W CALC'D POSRION r NEW \ '/ 275.95 AiN ELD 2 0 6.335 Act. w't j4203/M0010 oiH HODGSON !^'1` O w 1 1311 W. GALLAGHER RD. !l77NNEE �\ T!0 n i Off' CWE i o:::.T.Y A( , o PUy1P 3i DRA n N0U5 0 Y! -------------------Thy-- _ __ _ _ ______.._₹ ---___-_.___ 666.09 31 32 N:> $ 89'45'21' E 6 5 FOUND T. CO. MON. A# Ob- 77 LINE TABLE DATE APPROVED 7-/6-07 NO. BEARING DISTANCE 7, d fy LI N 892328" E 89.39 ,� ,l D (, LOPMENT L2 S 0254 '32 E 120.96 L3 S 8945 '21 E 150.23 L4 S 025432 E 124.92 L5 N 88'22 '15 E 60. 70 DATE.12-11-06 I LENHERR SURVEYING P.L.L.C. SHARON E93LEl' DWN:MHA APR:,kE PROFESSIONAL LAND SURVEYING L06-217BLA(NEW) P.O. BOX 1155/209 S 3RD ST. SCALE:1 =200 ELMA, WA. 98541 PH.j' (360)482-8750 SHEET I OF 1 nm+mc o..__ 41 _t+fl flVH Cl9/V1l non e.na ou u_..__ n_..-4.. torn - -- n-� II __ -� O F _ v S it f2 ! j1 i W _ YC W .� U u � AC ZC LLYS x g ₹ 3 Y) A, `J I �'C '8n — p Y U r � _ _ _ . I - x .' v z g L 1 a 4 a y f o of ene . _ _. 3I ��ua5 �xf � y Oc L _ — s7e •. Z nx_ r -a z 4 a T I V N I sk 1. «A. I ry z_ Ii a 6 cy�t3 ` o s -_ 4! 40 Valve Control Box with 1.25 Boll Valves 1 ylT3 2 Trcnspart Line II 11 11 O 1 6 Iis Feeder Lines Typicel Clecr o,il l II C i II Typlcv. Observe Ion Port 1.25 Loterpl 30 o 60 _ o Detailed Droinfleld L_aycu eTY?t R< s<ole 1 to cg ERdRTf oN Floci Grade T I E o 20 C Q`:o 12 sordr Leoml Fuer Fabric Cover II On rywl Grade _ z , 40 1 .25 ' Sched. 40 _aterals a-4' to 3-„z o — 1.25 Laterpl q 8) 3/ '1. 6 Cf!f'II S1 C 50 Q C. a" Drop, s Per Lateral_ s1 & Last Orifice Ra<p 30 From End of Trench 36 ' Screw-on Ccp �Q. 4' /45 `Jo9ree Elbow LCL:rcl Endo Ditch — -- Dralrfield Cross Section View Corot - clean Out Not To Scole C _ ) sate: elepnaw to be from 0 to 6 in<,ee elow 4Q- . � with Rebor. Cleii Out Observation Port a F,u a Grades Er. ends Note; w � Required a' the End r E 1 Lateral. i Be4 PVC ID from ableBott m of T m h To Finished Grade. Removable Cap t+ ll be F' tlld oe rvt Pp . Archer Arrow SepT'.c Designs On e tt h GI e o //�� n y^< ' Mnm= of 5 Tofal Required m Srt 5orO ( 360) 39V 2 ? 5J ;a2� PAULA or ;oRrvsnry �J Length Length Orifice # Distance from Distance from Lateral# (In.) (Ft.) Spacing Orifices Feeder Line(In.) Cleanout(In.) 1 480 40 60 8 30 30 2 480 40 60 8 30 30 3 460 40 60 8 30 30 4 480 40 60 8 30 30 5 480 40 60 6 I 30 30 Total Lateral Length 200 Total#Orifices 4pj GPM= 23.6 Dynamic Head Calculations Selected residual pressure: 2 ft' Length (Ft.) #Orifices Transport Pipe 480 40 4.80 ft. Feeder Total Lateral Line Length Lateral#1 40 2 42 8 0.15 ft. Lateral#2 40 11 51 8 0.19 ft. Lateral#3 40 20 60 8 0.22 ft. Lateral#4 40 29 69 8 0.25 ft. Lateral#5 40 38 78 •8 028 ft_ Total Elevation Lift 10.00 fl Total Dynamic Head 17.89 ft. THREADED UNIbN SECURED L D WI TH GAS TIGHT REAL24 D4ATER ACS RISER $6MDE N. YKVE• FRIDNI� __ c=•TO DRAMFIFLD -TIC ������ ANTLLMFI�OII IRON MATER NAME LEVEL .. FLOARIO T LEVY. WOFWJNG VOLUME FORTFLOAT NORMAL -- MOUNTNIG G..p...'l,�rl�i PUNS _ .CHECK VKVE' CENT LE L amIYEN?S FINRr Nil /�=�PAULA JOV JOHNON ; /��r \ ' r II1'� .AS HEEDED wired by WAC chapter 246-272O and FIGURE 2 Septic Tanks must meet standards req manufacturer must be on Dept of Health list of registered sewage tanks. `1 3 7 D....Tcnf Ac - construc a st 13 1) onz e dig,head e $i av&L2b. ( 41series) - _ 0oub haft seat versions availabe for added protection Flow-Mate no models 1401:15. For einjormation,see Technical Data Sheets FMD81,FM2783. In high head dewatering or effluent applications where pumping E-=o=at U E performance ''.s Critical, this robust _- ,. family of pumps is known for reliability, durability and performance. These pumps are especially suited for harsh I environments. ZoeLL /s e coal run design T —r ' and corrosion-resistant,powder coated epoxy finish add up to a long-lasting, _ trouble-free produc,. APPLICATIONS: STEP or ors:e applications I r+ Watertorsfer Light comp-e "'.de ate g - ' SPECIFICATIONS: m ' • 112 NP'd - ,a.g 12HPthr `P gh hP MADE IN THE USA • Availa Mein auto ma c or n onau to matic 1E_IWGiDIk..,+ i • Model 137.139,140:1/2'12 mm spherical solids capadry nub vortex Impeller • Mode'145.3/4 (19 mm)sPher caLsolids capacity with .v.r. vortex im peLLer % ~! a` jç PUMP PERFORMANCE CURVE MODEL 151/152u153 151;152/153 Dose-Mate I This is our fastest growing Line of effluent - 53 pumps.The 150 series is truly a workhorse designed for reliability under extreme — conditions in an effluent environment 1505enes pump curves cover a wide range I 51 of applications. They are weLL suited to applications with Low pressure pipe(LPP) t s and enhanced flowSiEP sysaems.Zoe LLer's cool run design and corrosion-resistant, + _ _ powder coated epoxy finish, in addition to the hermetically sealed, oil-filled motor and non-clogging vortex impeller add up to a long-tasting,trouble-free produce = It — APPLICATIONS: STEP oT onere app:cat ons MADE I NTHEUSA U. co lcewater-ng n .Illowrlo: +_r _ ______________________________ITI— SPECIFICATIONS: an -0a o oz UT Pt=VIhU1 �_�• 1-1/2"NPT discharge • 1D HP through 1/2 HP hAc • Availa b le l n nonautomatic or wIn a va r!a ble leveL piggyback mechanical switch /2''(12 mm)spherical solids opacity with vortex thermoplastic impeller For more information.see Technical Data Sheet P42 784. D AT rights reserves. ZOELLER PUMP CO 1502-778.2731 1800-928-789 1 zoeLLerpumps cam 9 ')3 r«eQNv,FlN3E�GRAS rOn 6� s 0 I P 2 0 b I . • 0 O cauu ¢n 0 0 G 1CMNMAI DRNN'/dIDTX e D O 7 I 0 0 0 fILTFR FPBPoC CPTICNAL e e CNSIDESDFCFAVEL 6 &L PtAZT1CsfEEIINGCM'^'""' + Z-,t iO rf 00 CVPON4 ON DOMtU4be'�'b"'� SIDE OF GRAVEL GRAVEL 1e-K r 00 7m O 1ft QtAVEL IANMJMABOVE lJ PEA GRAVEL ETC 0 O 5TRICINE LAYER ^ 0 � �i.0 o H&IT INTO 4'MNMIM DIA .J RESTRICTIVE LAYER CPITED PE PE PIPE IN BO1I OF T cNCH� �11 3 r3aaa»ve3 � 3W5 9L-L A9E) L'• �IOHd 'Na'p v^,H26M pNPOti'J 3LJV&LwXOS 0d `4Se�l 0°� AS DNI ONId33NIJN3 N3` Fa'4— ° J 'L EVy9 �3 I 23u5 } in C o? PGY --- -- 3 t - ' -- - 1S -e �= 3 z -`- g \ 2il £ 3 - o z w° £ ti •- _ < z. N `gym II t —_ nm /, C - F:_ Z-± h A f J;LH ra REVISE 2/17/25 3 NUWATER BNR-500 DETAIL ENVIRO-FLO, INC. WITH EXTERNAL TRASH TANK Wastewater Treatment TecdnologJes NITROGEN REDUCTION VERSION P-°7 B°X321'61 601) o° MS 39232 (277)236-8G�6 (607) 8flet faa' viwvi enviro-ilo ner 1113 Nut at mane Water 4 j � I fl PARTS LIST NuWater NR Assembly Diagram A DUAL FORTFER&TOR N.POLY O:FFUSER SAR(Z 3.3S RUBBER 99°Wi CL.TiPS R) H.YPVC(317 SECTI0H) C.318'81W X 1/ADAPTG &°TOZ'NPi)2', C.'."SUP CAP O.hr SL1P%tl2'NPTAOAPTCR P.t/e"C'_EAA PVC H0BE cPT.l0NP1 i] Y ST ,X'.?NPT SUSNNG(3) <l.1(Y'PVC PIPE(BY INS TALLER) F t?90'ELBOW(3) R Y PVC PIPE(SY WST%WER) 1'X YX: PTEE S.Z'PVC PIPE(BY INSTALLER R,V 90°ELBOW(3) B+ BEDPLPPTOR TO'v<"NP!(21 7 X P BUSHING U.P2'STREET X nS NPT BUSHING(1) J.T'SANGARY TEE :.1t3'PVC COUPLER)Z) K.V PVC CROSS W 7 COUPLER BY INSTALLER; t'COUPLER(BY INSTALLER) Revised 2/25/12 IZBerr3 au Septic 17ejigm, Jac. , n ' NuWater BNR Pretreatment AW INSTALLATION & NLUNTENANCEPressure Distribution Systems vnurn nor�91INsoN Z'ti 1. Install Laterals with contour of the ground. 1CpNSla b�5i6N 2. Install trench bottoms level -( _- 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock, (do not glue), after pressure test and Environmental Health Dept. approval, turn orifices down (6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade, run the filter fabric at least 2 inches down the trench wall. 11. Waterlines must be a minimum of 10' to any tank or drainfield (a reduction to 5' may be obtained with a State waiver on lots that meet minimum lot size). Encase all water lines within 10' of septic transport lines and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system. 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14.No vehicular traffic over drainfield area or tanks. 15. Inspect floats, clean filters, and test high water level alarm every 6-12 months as needed. 16. All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19. All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8" hole drilled in the discharge pipe above the pump to prevent siphoning. Ensure anti-siphon hole sprays down,away from tank opening. 20. All transport lines under driveways or parking areas must be encased to prevent crushing. 21. Homeowner is responsible for all property lines and easements. 22. Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation& Maintenance on your NuWater pretreatment system. 13 �3