Loading...
HomeMy WebLinkAboutSWG2026-00124 - SWG Application / Design - 9/11/2026 MASON COUNTY 415 N 6TH STREET, 0427-9N,WA 98584 ASHELTON.360-427-9670,EXT 400 BELPAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX 360-427-7787 On-Site Sewage System Permit: SWG2026-00124 CDUN(Y APPLICANT DAVIS FAMILY ASSOCIATION Phone: Address: MULLER;WILLOTT;PENTZ;DAVIS BAINBRIDGE ISLAND, WA 9811O-27O5 OWNER DAVIS FAMILY ASSOCIATION Phone: Address: MULLER;WILLOTT;PENTZ;DAVIS BAINBRIDGE ISLAND, WA 9811O-27O5 SEPTIC DESIGNER CINDY WAITE" Phone: 36O-7O1-O2O5 Address: 80 E PICKERING LANE SHELTON,WA 98584 SEPTIC INSTALLER TAYLOR TONEY' Phone: 36O-489-9169 Address: 2971 E PHILLIPS LAKE RD SHELTON, WA 98584 Site Address: 111 E BIG SKOOKUM RD Primary Parcel Number: 220207500060 Permit Description: Repair/Upgrade to 5bd OscarXO2 Permit Submitted Date'. 04/24/2026 Permit Issued Date: 09/11/2026 Issued By: Rhonda Thompson Current Permit Fees Paid: $845.00 (additional feeslrlay be required upon installation of system) Permit Expiration Date: 05/01/2027 based or dale m inspeamm Permit Conditions: I Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Grainfield installation not to exceed designed upslope and downslope depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 7 Mason County Asbuilt Form, Record Drawing, and installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY — MASON COUNTY C > AMOUNT RECEVra Im m CO Public Health & Human Services DE.%Y ° m < N Enoi,anmenal Health 360>➢-9670,eIt 400 01 360275,4X67,1.1 400SWG COO 415 N oth Street-Shelton,WA 99584 , o� I - — c c i ; z y ON-SITE SEWAGE SYSTEM APPLICATION 3 m APPLICANT HONE DAVIS FAMILY ASSOC/B-LINE CONST I 360-426-4221 c MAILING ADDRESS STREET.CR`1 SATE ZIP CODE Ca 359 GIDEON LANE NW %AINBRIDGE ISL WA 98110 z 111E BIG SKOOKUM RI .l(_SITE ADDRESS-STREEr CITY ZIO CODE c_i C� ELTON WA 98584 ^' FAME OF DESIGNER P NE CINDY WAITE ty�� 2-701-0205 NAME OF INSTALLER 'HONE O I O B-LINE CONSTRUCTION B"I 360-426-4221 o- f°vy-116ti ≤ y I N PERMIT TYPE(sect one) DPI RI NGAATER SOURCE O F C RESIDENTIAL 1.! COMMUNITY 055 1hCOMMERCIALOSS ❑ PRIVATE INDIVIDUAL WELL b PRIVATE TWO-PARTY WELL Z a PUBLIC WATER SYSTEM TYPE OF KORR lPpIOI one; h NEW CONSTRUCT! /UPGRADES REPAIR I REPLACEMENT OTTER DETA L5(select 80!ar apply) 0 TABLE X REPAIR O SURFACING SEWAGE ❑ EXISTING FAILURE D SHORELINE SUBMITTALS p O Iq DESIGN FORM(REQUIRED) SEPTIC DESIGN(REQUIRED) BEDROOM5� LOT 52E O LOT CREATED AFTER BED _ n EWAIVER(sI OF APPLICABLE) 3 ❑ YES ❑ NO o DIRECT ONE 10 SITE AND SITE CONDITONS 'x NOG!Pale) TAKE HIGHWAY 3, TURN RIGHT ON AGATE ROAD, TURN RIGHT ONTO BENSON LOOP ROAD, TAKE FIRST RIGHT ONTO BENSON LOOP ROAD, TURN RIGHT ONTO r I a BIG SKOOKUM RD. PARCEL IS ON THE RIGHT SIDE OF ROAD. SOIL LOGS ARE -, NEXT TO BIG SKOOKUM RD, RESIDENCE IS DOWN ON THE WATER. I rn SITE MUSTBE F(i1GGED FROM MAIN ROAD AND TEST HOLES MUSTSE FIAGGEO MTH TEST HOLE NUMBERS. I O - OFFICIAL USE ONLY BELOW THIS LINE UPGRADE)FAILURE SOURCE ITC,repoeln9 purposes) ❑VOLUNTARY []MAINTENANCE/PUMPING O BUILDING PERMIT OH0ME SALE ❑COMPLAINT O0THER._ INSPECTOR SOIL LOGS COMMENTS;D0NDIT.ONS Z: O .3Z Si LL ( tot vd ' to I : S CL 4rvu d v/ S�II A+ � O RECORD DRAwN6ANo INSTALLATION REP RI SOIL CODES: V=VERY G=CRAVELV 5=SAND L=LOAM SI=SILT C=CLAY E-EXTREMELY R=ROOTS REQUIRED FOR FlVALAFPROVAL A5PEOTOR SIGNATURE SATE APPLICATION EXPIRATION DATE APPLICATION APPROVED]ZSUED BY �l Z9E SIB �I I Iz� THIS FORM MAYBE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE RevIse1 411412025 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 0 2 0 7 5 0 0 0 6 0 A design will be reviewed when 3 copies of each of the following are submitted: v Completed design form that has been signed and dated. v Scaled layout sketch,including all applicable items on checklist. v Scaled plot plan,including all applicable items on checklist. v Cross-section sketch, including all applicable items on checklist. This forte may be scanned and available for public view on the Mown counw Web site,Macimam r size: 11"X 17" F PARCEL IDENTIFICATION Permit Nurnber: SWG DQtq ooi .4 Designer's Name: CINDY WAITE Applicant's Name: DAVIS FAMILY ASSOCB-LINE Designer's Phone Number: 360-701-0205 Mailing Address: 359 GIDEON LANE NW Designer's Address: 80 E PICKERING LANE BAINBRIDGE ISL WA 98110 City State Zip SHELTON WA 98584 City State Zip Designers Email cindyawalte®msn.com I DESIGN PARAMETERS Treatment Device ❑Glendon ❑Sand Filter ❑Mound ❑Sand Lined Drainfield ❑Recirculating Filler ❑ATU ❑Other XO2 Treatment Level(check all that apply): 'A 18 IC lBLI 181.2 181,2 IE ❑N Drainfield Type ❑Gravity ❑Pressure Cl Trench ❑Bed O Sub Surface Drip Septic Tank/Drainfeld Specifications Laterals Number of Bedrooms 5 Schedule/Class NETAFIM Daily Flow:Operating Capacity 450 gpd Length 50 ft Daily Flow; Design Flow 000 Spd Diameter in Septic Tank Capacity(working) 1500 gal Number 5 Receiving Soil Type(1-6) 5 Separation .5 ft Receiving Soil Appl.Rate .4 gpd/ft' Orifices Required Primary Area 1593 ft2 Total Nu f Orifices 10X50=500 Designed Primary Area 1500 ft Diamet EMITTER in Designed Reserve Area 4s 5b( ft° Spec' CvR ' , .5 in Trench/Bed Width 59 ft �'°3;`iJs�4 Manifold Trench/Bed Length 27 ft ul ar �la�SCHEDULE 40 Elevation Measurements lit Stnne tar SUPPLY- Y2�,RENRN ft Dr E Original Drainfield Area Slope <1 % imtna DESI 1.25 in New Slope.If Altered % C n used? D Yea gNo Depth of Excavation Up-slope 0 in Transport Pipe from Original Grade Down-slope 0 in Schedule/Class Designed Vertical Separation 12"+ in Length ft Gravel-based Drainfield Required? O Yes O No Diameter in Pump Required? 16 Yes O No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 360 Diff.in Elevation Between Pump&Uppermost Orifice_ft Dose quantity 1.28 gal Drainfield Squirt Height/Selected Residual(head) _ft Chamber Capacity(flood) 2004 gal Uppermost Orifice Cl Higher O Lower than Pump Shutoff Pump controls:Please check those required. Capacity @ Total Pressure Head gpm Ef Timer lid Elapse Meter I1 Event Counter Calculated Total Pressure Head 81.82 ft If Timer. Pump on 22 SEC ,pump off l M r✓3Phvs Comments I 1 STAKE OUT DRAINFIELD AFTER CAREFUL CLEARING, VERIFY LIFT FROM PUMP TANK TO OSCARS, Revised:6/11/2025 DESIGN FORM—PAGE TWO Assessor's Parcel Number: 2 2 0 2 0 7 5 0 0 0 6 0 PermitNumber: SWG CJ( -,- O1a`f DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch El'Test hole locations .W Drainfield orientation and layout Reference depth from original grade: O' Soil logs m Trench/bed dimensions and M'Septic tank Property lines critical distances within layout W"Drainfield cover Existing and proposed wells 0-Box/Valve box locations Reference depth from original grade within 100 ft of property Septic tank/pump chamber and restvictive strata: 21 Measurements to cuts,banks,and locations P /- < mw Laterals,trench/bed,top and surface water and critical areas 'Observation port location bottom Location and orientation of 611 dean-out location 0 Curtain drain collector curtain drain and all absorption ®'Manifold placement ❑ Sand augmentation components E(Orifice placement Other q055-section detail: 2'Location and dimension of primary system and reserve area Lateral placement with distance Observation ports/clean-outs to edge of bed 'Buildings Other Information Audible/visual alarm referenced Yes No Direction of slope indicator l 'Scale of drawing shown on scale ii ❑ Design staked out IiI'Waterlines ,.,/bar ❑ ❑ Recorded Notices attached 1a Q7"Roads,easements,driveways, Elevation benchmark and relative ❑ ❑ Waiver(s)attached parking elevations of system components lI ❑ Pump curve attached f1Y North arrow and scale drawing 0 ❑ Evaluation of failure shown on scale bar Nen-residentialjustification ❑ ❑ Waste strength ❑ ❑ Flow DESIGN APPROVAL The undersigned designer must be notifi by installer at time of installation Yes ❑ No _ Z L-4 %, Signature f Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to he in compliance with state and local on-site regulations: Environmental Health Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. �[I Iz-7 '' The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. r� This form may be scanned and available for public view on the Mason County Web site. Revised:6/I I/2025v\, t N `^ N C r o � ' U a 1 1a q�q K fi N �N ° L 11 � r .Y _ ��• � � O "is Zo.a I e u'ne a 9 lq.q eW\ IJgq I( 110 QQ ti rQ.0 a` V �,.v ��itEiv�seo_�3 GN Z > e 31`�e 00� C i a WLNT W � x39 C z r.,. Ek S ° a n n N c 0 o Q. • `. N n\ x -- --------- O 1/ W p� to V � V ppY / o ® pp°jA Sn N + G m v m N A W + e uuiriliup PF1 adeNse3 y m o o a m S a ° d c c m m o c a o m 3, ir'�.. c p oop 7 °k m `G 6 o (� �P ,. C °' d 6 C po C n, ro. C C '° 9 6 Gvne�.i � ✓ w t. -- - 7C �G LiCk.vs�p p�•yGNER O Z➢ �- �` H I I S' Ur . oa I1 iL-r A: / $ SIi ' 5 LiCENS pEGGNER -+ 34' ( sIv i � 2i' Headworks: There are two options for headworks with the OSCAR-XO2 system. The original X02 kit has the automatic reverse flush headworks while the new version XO2M kit has a manual headworks (see appendix). There are no solenoid valves in the X02M kit. TABLE a� Hydraulic Layout OS-50 coils �4 4 1 1.4 7.8 50' ID!' 5 5 1 1.75 9.75 50' • 61 3 2 2.1 6.2 50' r 8 4 2 2.8 9.2 50' 8 4 2 2.8 9.2 50' • � r 10' 5 2 3.5 11.5 50' e TABLE 3 Hydraulic Layout � .P77; 1J'"'s OS-100 coils 5 • ' , ®®______ rte GNER �21 2 1 1.4 4.6 50' 3' 3 1 2.1 6.9 50' r 411 4 1 2.8 9,2 50' I ' 5 5 1 3.5 11.5 50' (Q TABLE 4 Minimum Shoulder Lengths OS-50 •. - 240 I 22.5 300 28 360 33.5 480 44.5 600 55.5 The dimensions in Table 4 represent the minimum required length of the outer shoulder which include coils, spacing between coils, and shoulders. These lengths can be extended to match site conditions. Minimum shoulder spacing and spacing between coils is 6 inches. See illustration below for example of shoulder length. TABLE 5 Minimum Shoulder Lengths OS-100 240 F 14' 2 Inches 360 21' 4 inches 480 F 28' 4 Inches 600 35' 5 inches The dimensions in Table 5 represent the minimum required length of th houlder which include coils, spacing between coils, and shoulder. These LengtIjQtbe extended to match site conditions. Minimum shoulder spacing is 6 in s. illustration below for example of shoulder length. P ape Basal Area: y � NA The basal area is comprised of the total area where' -Lt sdnd,m" �a is in contact with the receiving soil. The minimum required basal areai3caltdt by dividing the design flow rate by the soil loading rate specified in WAC 246-272A (Local codes may have differing loading rates). , 1� F=L(Q/KO)^1.85 CALCUUATIQN F=friction loss through pipe I feet of head DO NOTCHANGE L=Iength of supply line in feet FILL IN Q=Flush GPM K=47.8 (1'SCHEDULE 40) LENGTH 200 I4( SL4MIC '{� Q FLUSH GPM __ 8 K (1"SCHEDULEN40) 98.5 FRICTION LOSS 1.922602 TDH _ _ 1.922602 TOTAL HEAD FRICTION LOSS 1.922602 ELEVATION FROM PUMP TANK TO OSCAR 50 TOTAL HEAD 51.9226 <50 EXCESS TDH GMP DISCHARGE AT DF EMITTER GPH 0.42 .42 GALLONS PER EMITTER PER HOUR MINUTES PER HOUR 60 # EMITTERS 50 #COILS 10 GPM PER COIL 0.35 GPM PER TOTAL COILS 3.5 w ^ Nr DOSEVOLUME s GPMPERCOIL COILS 10 , tV. SECONDS IN MINUTES 60 SECONDS ON 22 GALLONS PER DOSE 1.28 CALCULATION TIMER SETTING DO NOT CHANGE TIME OFF SECONDS 218 3 MIN 38 SEC TIMER ON SECONDS _ 22 22 SEC TIMER SETTINGS GPD 184 FILL IN GP DOSE 1.28 DOSES PER DAY 360 GPD 462 OK 4 �� Tanks for a 500 gpd design = 1,000 gallons A 7 bedroom design (120 gpd x 7) is 840 gpd. 840 gpd/500 gpd = 1.68 or 68% increase Minimum tank size for 840 gpd = 1,000 gal. x 1.68 = 1,680 gallons Therefore, a 1750 gallon, two compartment tank can be used. For tanks with water tight, structurally sound partitions: for both the treatment tank and discharge tank a double compartment tank with tee baffles can be used (no flow through ports). Flip the discharge tank around so the smaller compartment is first as shown (see Illustration 2). The clarifier Chamber is to remain full. vEMTfiLt )5 0° a2 ero Illustration 2 As the daily design flow rates increase, larger tanks will be needed. It ma �. become necessary to have individual tanks for each chamber or a combination '& tanks to meet the volume requirements. For example: s ^h 3 Y 3.000 god design flow (refer to Table 1-21. Septic chamber = 4000 gal. needed, use a 3000 gal. tank + 1000 Aeration Chamber = 2-1000 gal. tanks. Clarifier chamber = 2- 1000 gal. tanks. Pump chamber = 3000 gal. tank + 1000 gal. tank. In this example, the septic chambers could be connected using standard tee baffles making a two compartment chamber. The aerator chamber could be arranged the same as the septic chambers. Half of the diffusors would be placed in �1t g 1500SR & 1500SR-HW 128" ----------- ---- --- 79 � � 41 " � LT I jl j € 24 0116 NTOP VIEW iI 72 Sep/ic w A�7 I :. jl ryGp_e A'.cJ � 24 LflENCO TAKK ADMTEfl6 4' UST-A-SEAL GASKET — 4' PVC BAFFLE 4 FLOOD cAv. �zaa GALA FL000 cor. 65" T B2) GALS. 55- 1 /2 53 30• ' 3 ` 2- 1 /2 \ S APPROX. WEIGHT 12.000 LBS. 2250SR & 2250SR-HW 137" 96- 1 /2- ------- 32- t /2" 2a18" 24" TOP VIEW90" 84" 4 �ar/ y�Ip Gh•Im62 � i i i � i �42.6��1 --------- ------1� — — 3„ 2!' ORENCO T Ht ADAPTERS TIC 4 CAST-A-SEAL GASFET 4 PVC BAFFLE 4 4I FLOOD P. 2001 as. —1 ROCU �' 8 BIT GAL5. 68" �P � 58" sP 56" GIND�WAITE LICENSED DESIGN R +ups os,Iv __J 2- 1 /2 H H 3" \tp APPROX. WEIGHT 16,500 LBS. 1' each 1,000 aeration chamber. The clarifier chambers could either use tee baffles or be connected together below the liquid level. The combined pump chambers must be connected below the liquid Level. Table 1-2"' 1 AKOOM, ffta°' "Puna /�at ara 8ggg061 . 4 , 500 gpd 670 330 330 670 1 1,000 gal.treatment, 1,000 gal.discharge 750 gpd 1,000 500 1,000 500 2 1,500 treatment, 1,500 discharge 1500 gpd 2,010 990 990 2,010 3 3,000 treatment,3,000 discharge 2000 gpd 2,680 1,320 1,320 2,680 4 3k&1500 treatment&3k&1500 discharge 2250 gpd 3,000 1,500 1,500 3,000 5 3k& 1500 treatment&3k&1500 discharge 3,000 gpd 4,000 2.000 2,000 4,000 6 use multiple tanks to meet volume needs 3,500 gpd 4,700 2,310 2,310 4,700 7 use multiple tanks to meet volume needs `Minimum liquid volume needed. **Local health jurisdictions may require larger tank volumes. *Table 1.2 is a quick reference guide. Aerator: For each 500 gpd design flow one aerator will be needed. Round up the design flow to the next 500 gpd value. For instance, a 600 gpd design flow will need 2 aerators (600 gal. rounded up to 1000 gal. needs 2 aerators). The aerator box must be installed so that the bottom of the aerator box is at the same elevation or higher than the top of the tank risers, see Illustration 3. If the site is sloped the aerator box can be buried, upslope from the tanks. The sides of the aerator box lid must not be buried. Aerators can be installed up to several hundred feet away from the diffusors. The line between aerator and diffusors must slope toward diffusors. Aesthetic concerns should be considered when placing the aerator box. Place the aerator away from house windows, doors, and areas where people to d to congregate, such as patios areas and barbecues. ex,m o �1 1 o INnsy ,`�N1� yfss x ,r, LICEN D DEDE �iON ER Illustration 3 Headworks, manual flush: HWN-.7-man • '/4 inches Arkat disc filter, mesh, 130 micron • 3/, inches Arad flow meter • Three oil fitted pressure gauges (0-100 psi) • One 1 inch Spears gate valve for flushing. OSCAR-X02 Parts list (500 gpd). Each OSCAR-XOz unit will include: • LF1 P-RF-ARA control panel • LOT-30, 1/2 hp, 120 volt pump • Hi-Blow Aerator, HB-80 (80 liter/minute) --Z • Hi-Blow diffusers • 05-50 or 05-100 Coils • PVC fittings and drip tubing adapters • HWN-.7-RF automatic headworks • Solid 1/2 inches poly tubing for connections • 2 float switches OSCAR-XO2M Parts list (500 gpd). Each OSCAR-X02 unit will include: • LF1 P-RF-ARA control panel • LOT-30, 1/2 hp, 120 volt pump • Hi-Blow Aerator, HB-80 (80 liter/minute) • Hi-Blow diffusers • OS-50 or OS-100 Coils o 5 sin, ,F Nam • PVC fittings and drip tubing adapters c;AITE 4tk • HWN-.7-RF-man G� e .crveR • Solid 'h inches poly tubing for connections • 2 float switches 3 OSCAR-X02+1 Parts list (501-1,000 gpd). Each OSCAR-X02+1 unit will include: • LF1 P-IF-ARA control panel • LOT-30, 1/2 hp, 120 volt pump • Hi-BlowAerator2 (2), XB-80 (80 liter/minute) • Hi-Blow diffusers (4) • OS-50 or OS-100 Coils • PVC fittings and drip tubing adapters • HWN-.7-RF automatic headworks • Solid ½ inches poly tubing for connections • 2 float switches OSCAR-X02 colt Connections Manifolds and supply lines are 1 inches Sch 40 PVC �V q p2 CINCV C WgITE ��+' UC F SF^OFaONER Manifold and blank tech line adapter and connection. Blank tech liner and Bioline connection with internal coupling Inspection ports. . . _>E Screw Type Cap or Slip Cap ..-- < Screw Type Cap or Slip Cap t-4"PVC Pipe F4"PVC Pipe (Length Varla) (Length Varies) 14 r 4"Lone _ -•� t Slots(4)@90*Apart Toilet Ring 4"PVC T. OSCAR Cover Options. , y1 _. j � UER =� There may be a desire to cover the OSCAR with something additonat to the- - specified ASTM C-33 sand. The intent is not to have too much additional cover over the final C-33 sand layer that would prevent the sand from accessing oxygen from the atmosphere. Placing too much cover will inhibit plant root growth. Because the C-33 sand is sub-surface irrigated, grass and other ground cover will grow C 11 $ rapidly, forming a firm protective cover over the OSCAR. At the end of the first growing season the C-33 sand layer will be as firm as native soil to walk on. Options include: • Landscaping jute mat with grass seed or ground cover plantings • A thin layer of mineral soil low in organic content (<10% organics) • Thin layer of crushed or washed rock for wind erosion protection. • Thin layer of bark to wood chips. • Aggregates the size of rip-rap (5-6 inch diameter) can be "placed" on the OSCAR for protection from deer or elk traffic. These Larger sized aggregates must be placed, not dropped, on the OSCAR to prevent breakage of piping and other materials. • Wire mess can be installed over the sand to prevent erosion and allow for grass to grow. Do Not Cover C-33 Sand with: • organic mix (manufactured top soil from compost) • filter fabric LOT-30 pump curve: 1II. iL Thermoplastic I 6fla•a[•nra.NMi,W[.•a shwa.WI rwWnaaala ONIYMiu(wm S4 dWnn. S*.,&Y.R as•Y[ Man .rtr.•.vnl,.wwa,w .r:n•Y Aaaiaalamol,e Wpnraaaw Wawa W FWn[khddddG[Iwww Mwnaro m..yW W alaw•awy W[wan..nww.. roucl e.uen E-]h 6W En __ _____'1 a �P a !2. �.lD ss mousy yaynuiyo[wny r� aisa.0 0.s wMM.. I a iw 31,1[4Pxa n.xia.�Wo.iw. Ia-au. N5110j £I unviIM W ..n M 1(Id Y nSYWUMa W .W W A L w IIV�/� 'sale. Y.r.Yc IYM.:.Si,U.all W M(Si H LilaMll KSr 4 i•WVm.n.nl wu.n.ur.AS ma u...naa uuld &YEfAI Installation Notes Oscar-XO2 Treatment System 111E Big Skookum Rd 22020-75-00060 1. The prepared site plan is not a survey. It's the owner's responsibility to verity property lines, utility lines (water, sewer, power, phone and gas) prior to installation. 2. Verify lift from tanks to Oscars prior to installing transport line. 3. This is a repair for a three bedroom system with Install approval In 1981. Design is for a five bedrooms conforming drainfield and reserve, 4. Owner must string the east property line prior to Installation. 5. Installer responsible to contact designer prior to installation. 6. Installer responsible to submit installation form to designer with a plot map, tank information, pump information and any changes from the original design. 7. Oscar drainfield: ASTM C-33 sand media as per Washington Department of Health's Recommended Standards and Guidance for Intermittent Sand Filter. 8. All new lines in the driveway must be cased. 9. Two aerators required 10. Minimum of 6" of sand throughout out the lateral(coil) area, must be level. 11. Oscar X02 parts list on Page 13 12. Controls to be set per XO2 guidelines 13. Septic tank location must meet all required setbacks. 14. Keep wheeled vehicles off the drainfield area before, during and after installation. 15. Tracked equipment only 16. All ground, surface water and roof drains must be diverted away from the septic tanks and drainfield. 17. Ensure the final grade slopes away from these areas and water doesn't collect on or around them. Use swales, berms, catch basin and tight lines, curtain drains, etc. to divert all waters 18. Curtain drains can be no closer than 10' upgradient and 30' down gradient of the drainfield 19. Exposed restrictive layers, cuts, banks, etc. can be no closer than 50' downhill from the drainfield. 20. Install access risers on all tanks, valve box and ends of laterals. 21. Make sure septic tank risers are epoxied or caulked to cast in riser rings on tank. 22. Lids must form a water and gas tight seal with the access risers. 23. This system must be installed by a Mason County Certified installer. 24. Deviation from this design without prior approval from the designer and Mason County Health Department will make this design null and void. 25. This design was sized per Washington Administrative CodeWAC246-272A-0230. The operating capacity is based on 45 gallons per day per capita with two persons per bedroom. The minimum design flow per bedroom per day the operating capacity of ninety gallons multiplied by 1.33. This results in a minim sign flow of one hundred twenty gallons per day. This creates a surge factor of b nticipated flow is ninety gallons per bedroom per day. v sF h� sJ CI (,N TZ L'fN$f G:i( GNER System Owner Responsibilities: 1. Owner or installer responsible for payment of installation permit prior to starting install. 2. Operation and Maintenance is required by Washington State Department of Health and Mason County Health Department. 3. The septic tank and pump tank should be pumped every three to five years or as needed. 4. System owners are responsible for having maintenance performed annually. 5. System owners are responsible for responding to septic issues in a timely manner. 6. System owners shall not at any time change or alter settings in the control box. 7. System owner agrees to read and abide by information regarding their system in the User Manual provided by Mason County Public Health. 8. Keep the flow of sewage at or below the approved design operating capacity. 9. Leaky plumbing can hydraulic overload your on-site septic system 10. Keep waste strength at residential waste strength parameters. 11. Spread loads of laundry through the week. 12. Do not use excessive bleach or detergents with added whiteners. 13. Do not shower, do laundry and dishwasher at the same time 14. Antibiotics can kill or impair the biological process in the septic tank. y S1 L` y11TE m; 1 IGNER