Loading...
HomeMy WebLinkAboutBLD2026-00909 - BLD CD Environmental Health Review - 9/22/2026 RR2.5 Zoning All setbacks are measured from the furthest Front Yard Setback. 25'. projection of the building. Side & Rear Yard Setbacks. Residential dwelling ADV2026-00099- SIDE- 5' M I N OR 10% width of lot if not more than 100' wide and accessory structures is 20'. OR approved ADV -- �-3 'F.AMlllwl(cwppu..n H1{:... ,ner Z000, 5'EL CLD Group LLC ` Pa rc e l N o.: 32232-52-08013 Address: 130 ETacoma St. a 1 itii .:.,.m Union,WA 98592o!os.DRIVEWAY' { w " Notes: • Septic Components as Shown in � '� ' SWG2022-00100 00 Proposed . :� •, �' • Road Access Permit not required 3/2 MH + saLLacl' • Address: ADD2022-00264 32' 38' �. soluraea 2a RSD>tsr aac+I+s th oa��rH LorsoF PE6�Es • Proposed Manufactured Home a�i °'EL(E31 a? ..i • 27x60 � '* 25' ` / r :.• G•6".dSTUREEDOtDFIL 3 bedrooms/2 baths ---1DNo—EJIi � - ---_ _ �. U s•ar, aosHas�wrLc�MvarNLnTsaFPEa�Es 1620s ft. � . • &I L3. p', • Front Landing/Stairs: 4'x 6' • Rear Deck/Stairs: 8'x20' 43 i ► a'•s'asTAKDOWFflt. SL4 __ Y i r-W..REDDI�i9RONHSWDYLQPHNIfHLOTSOFPERRS IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1DO% I PRIMARY i i :. i. SOLOGIt VIRIURIRIURIRIUR Deck/Landing/Stairs RESERVE DRAINFIEL �`I ; F•' ' O ' '- 5.9P:AFpp15HBRgM£dJlDY VATHLGTSOFPE�ES Septic Line sLa --- - ; L L V+4' 5, a, i r Setback +5'EL 100.00 +4"EL Distance EH Setbacks EH APPROVED A.) Drainfield/Reserve requires 10'setback from foundations. B.)Septic tank(s)requires 5'setback from all foundations. 20' 30' 40 50' 60' Water Line Rhonda Thompson 09/22/2026 C.)No foundation/Perimeter Drains within 30ft,downgradient of U V Drainfield/Reserve area D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area ----- E.)Use approved mitigation from section C1-9 of the department of 7,L -1 f1l C.7 r 11 !A I1/L Y. J11 r r F:(?r f-! r v , /n/f /fl C)-T--E/ R, � ,vT(s q I L31 [ AI I.>F.Mc?N." 7lfllt l. 1 !f/t nWNCJ r -:) ANIs CJ:; �h-fElF. I'IC ENT(:Y). ecology's"Criteria For Sewage Works Design, when sewer 5CAI.E FEET} -......,....... ...... . ...,.. .,,.,.,..,...N. .—... r,...-.. .„ r..,,,,.,.,..,,,.,,,,.,,,„�.� «,,.,�•,,,,,,., oK� transport lines are within 1 Oft of water supply lines. LEGEND D ACME DESIGN GLF.J�ARE L W l4 DATE- 17 AUGUST 2026 . r+4 Arry rsrAY e.-. rare.rrrzrrr 'C6PEN- Imo uPol�F'IrAL ELEv.o.'1'Cr1�Y/,Ir pl�M 'M.Av @fc Iii9uVM s r. I �'/ LOW AR Exs 8!1 a,-WA 09/10/2026 Disclaimer: Mason County does not require a APPROVED survey to obtain a building permit. As a result, site MASON COUNTY DCD PLANNING dy . plans may not reflect accurate data. It is the sen>T�11EDv,AU2P applicant's responsibility to comply with setback requirements.