Loading...
HomeMy WebLinkAboutSWG2026-00227-APPLICATION/DESIGN - SWG Application / Design - 8/19/2026 MASON COUNTY 415"67HELTON , 0427-970 EXT 400 SH STREE.360-42TON, n,9 400 BELFAIR'.360-275-4467.EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 i_IFAX-.360-427-7787 On-Site Sewage System Permit: SWG2026-00227 APPLICANT LOWTHIAN KAREN &JOSHUA Phone: Address: 3145 NE 8TH AVE PORTLAND, OR 97212 OWNER LOWTHIAN KAREN &JOSHUA Phone: Address: 3145 NE 8TH AVE PORTLAND, OR 97212 SEPTIC DESIGNER PAULA JOHNSON* Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 Site Address: 180 E Peregrine Ln Primary Parcel Number: 322327590141 Permit Description: NEW SFR -4BR Pressure Permit Submitted Date: 07/22/2026 Permit Issued Date: 08/19/2026 Issued By: Jeff Wilmoth Current Permit Fees Paid $570.00 (additional fees may be required upon installation of system). Permit Expiration Date: 05/1312029 (based on date of inspection) Permit Conditions: 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Drain field installation not to exceed designed upsiope and downslope depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 7 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 8 Future development will require a geological assessment of the site. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. .,FF C;iL USE ON_Y MASON COUNTY E �°L' CrIJ Public Health & Human Services '57 V Deggco o ti y NF s -, < 3s saa a,uo. "-_ S WG — 1 O 71 z N ON-SITE SEWAGE SYSTEM APPLICATION 3 'z m n owr m r Karen & Joshua Lowthian - klowthian@windermere.com (503) 740-9408 z va._rr=EE=-ss-s*aEE•: c.-v s;;= z=ccoE � 3145 NE 8th Ave Portland; OR 97212 p SEAD3REGS-STREET 5.1 ,-CCJ_ CO - 180 E Peregrine Ln J Union, WA 98592 w ^AffOWGSeptIC Designs, Inc N (360) 898-2255 R ..- N Fassio Excavating !. (360) 490-5519 PE M"3EE ."one: JL G� NS GGRFYERS CE T W zI�R DENIIRCOSS O:00MMUMTY OSS _ 4 / L01A L 6tLL E-1PRIVATE TWO-PARTY ELL Z F NJRK(sec:one) L G AaTER SYSTEM V NEWCOn'5`RUC 01 I.;.oORA02S FTREPAIR:REPLACEMENT O -S 1— e oc,> T LL g REPAIR pTAS C SLREAiNo] N CE ❑ Ex!Sr! fl ALRE ❑SH R EI:N'E LO DESIGN FORM'R QV RED) SET;..DESIGN:Rc'1..RED w5 LO _u:E AFTER 4,t1S2e ff IIVE,IsIt PP c.BL£i 4 1.47 ac ❑ YES NC x eo From Shelton take BrockdaleRd/ McReavy Rd to Union. After you come down the hill and I pass the gas station at McReavy Rd & Dalby Rd, turn sharp up the first road on the (L) onto r E Union Heights Dr, then take the 1st (R) onto E Peregrine Ln, follow around two sharp turns all the way to the end. Lot is on (R) with yellow sign "Lowthian" a N SRF MUST BE FLAGGED FROM MAIN ROAD AND TEST HO!£5 M HS T BE FAGGED WITH TEST ROLE NVMBERS. OFFICIAL USE ONLY BELOWTHS LIRE '3.A_ ,FA.J3c SOJRSE:I:::epc_y G-TOsem ❑VOLUNTARY ❑ AIN ENANGBP.:MPSG CEU'_JNG PERMIT 0 HOME SAE ❑CO P A\T ❑OTHERI 350.,_Gi 'MEN S ND.IO'$SOIL COOPS. VERY I � 6=CRAVflLY 5-SAND =LC AM 8: S.? C- E E- R=WOGS CUED FOP DNA A_. c, ss>• 'aE i :\OF_:_c. O! EXR.i . . o .-., = AP: Ica=, N ARe DATE Jh -13 z4 13- 2 °1,frIS MAY BE SCANNED AND AVAILABLE FOR PUBLIC NEW ON THE MASON COUNTY WEBSITE Rev:sed'4/14/2025 DESIGN FORM—PAGE ONE .Assessors Parcel Aumber 3 2 2 3 2 - 7 5 - 9 0 1 4 A design win be reviewed when 3 copies of each of the foI ou in c submitted Completed design form that has been signed and dated. 'Scaled layout sketch.n lading all applicable LCITIS on ch.eckiisl. v Scaled plot pan, including all app ieable items on checklist. I Cross-section sketch. including all applicable ite ns on checklist. This form may be scanned and available for public view on the Mason County Web site 11 xi ii i t m a u u El FARCEL'LDENTIFICARTON Desi { s Name: Arrow Septic Dew Inc permit Number: SVAle ash C \ Des nisPhone Number: (360)898-2256 Karen 8 Joshua Lowlhan 171 E Vuecrest Dr 3145NE8thAveDssiene 4ddrss: _— - - Union, WA 98592 Portland, OR 97212 Cis} State Zip .— Ciity State Zip Des.gner mail paulal@hctc.com DESIGN PARAMETERS Treatment Dee ice a ) c ❑ 2 ec : to I _. ❑ AFT LJ Oilte- i]p ,iii ❑9t ,.111t� ❑bi o.r.. ❑]andL _ — —sits ,r.. i Treatment Level t -S all dtatam�) A C6 CC — All C 61.2 C Bld fl 1 []V' Drainheld Tcpe ❑ G:aoiry R Pressure ircrch ❑ Bed C Sub Surface Drip Septic TanlclDrainfield Specifications Laterals ]umber of Bedmonvs q Scheduh;rC'ass 40 Daily Flow. Ope:air.e Copadry 480 gpd length 35 tt Dail} Flow: Design Flow 360 gpd Diameter 125 m , Number 6 Septic Tank Capacity(workin 1200 g} gal Receiving Soil Type(1 fi 3 Separation 9 ft Receiving Soil Appl.Rate 0.8 gpd, t Orifices Required Primary Area 600 [t Total Aamber of Orifices 42 Designed Primary Area 630 ftr Diameter 3/16 in Designed Reserve Area 630 fd Spacing 60 in Trench/Bed Width 3 R Manifold Trench!Bee Length 210 ft SeheduleCeu 40 Elevation Measurements Lenetn header Original Or ir.':.eld Area Slope 18 Diameter 1.25 in New Slope Ii A!t ied 18 Y3 Preferred moat ld c onf?araton used? Cd 1'es C No Deem of Excavation lope 14 _n Tra nsport Pipe f bon Orllica!Grade g i❑ < n :uleiCias 40 24+ in L th 110 ft Designed Vertical Separation _ (ravel— based Draoteld Rcq iim ❑ Yes No Diameter 2 in Pump Required? Yes ❑ No Dosing and Pump Chamber Pump/Siphon Specifications Numb Numbcr ofd 4 PPermos 120 eni Dili-jr,Elevation Beoveen pump& L t O 'an-' 2 g Chamber Capacity (flood] 1,200 cal Do afield Squirt Height'Selected Residual (head) Pump ntrol Please check slob. required. U apac5 ' Online O Higher Cif Lower than Pump Shutoff p qui Capacity �a Total Pressure Head 24.78 art Timer ❑ fi&p.a Vta?er ❑Jcevam Counter 2 min punt off 6hr Calculated 1.1.1 Pressure Head 422 tt II Time, Pump on f Comments AUG 19 20%E _ . _ - Revised: 4114'2025 DESIGN FORM—PAGE TWO Assessor's Parcel Surber: 3 2 2 3 2 -- 7 5 -- 9 0 1 4 1 Permit Nunn.:ber: SP'WG DESIGN CHECKLISTS 7t � t Plan Scaled Lacout Sketch Cross-Section Sketch e locations 9 Draindeld orientation and layout Reference depth from original grade_ s l� Trench/bed dimensions and septic tank critical distances with'n layout [d D annleld cover fines and proposed wells6d D Bot A ^ice boa petiti -.ons Rafcr dpth from original gradee00 ftofproocrty 69 Septic tam..pump chan.ber and resmchec strata. ements to cuts.banks,and locations Gd Laterals, trench/bed,top and surface water and critical areas fi71 Observation port location bottom ❑ Cunain drain collector ❑ Location and orientation of l9 Clean-out location ❑ Sand augmentation curtain drain and all absorption pl Manifold placement componer.s EZ Orifice placement Other cross-section detail. � Location and dimension of g I ateral placement with distance C11 Observation ports/clew -outs primary system and reserve area to edge of bed Other Information 9d Buildings Audible/Visual warm referenced Yes No 6r7 Direction of slope indicator rl Scale of draw+ng shown on scale d ❑ Design staked out Waterlines bar ❑ 11 Recorded Notices attached Roads, easements. driveways, ley o flhr In e O 6lA'atv'ei(s)attached parkt� ❑ Pimp curve attached North v do s os Sfdln of o ❑ Ec luanon of failure North arrow and scale drawing AUG 9 1'l�n ,hown on scale bar Non-residential justification - • ❑ fif Waste strength ❑ d elow D .: VAL P' The undersigned designer must be notified by We two i talLaiion C✓l Yes O No 11 Signibur', JliESi6NEa Date 1 .�]SSS NicNQSN The undersigned has reviewed this d sign on behalf of Mason Count Public Health and determined it to be in eomplianee with state and local o -si 'reR ilations: Env mi a al Hcaldh Specialist Date CAUTION: DESIGN APPR VAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped 'Approved"by Mason County Pubic Health. ( �� ✓ The Onsite Sewage Permit has not cxprzd.the Permit Expiration Date ✓ Drainfield site conditions have not bcer altered to adversely affect conditions of design approval. PleaseNote: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Revised: 4/14 20?s 2 s(< N /°24 34°W &LL4Th F328j t 1 �g H m _ n W NO3°0357° _ W _ _ _ 1509 �N �13g.PO p 138.00 30. PRIVATE ROAD E6MT1 rn :;z � _ — McKay Rotaftla� I I N w N sDo'50''47E( -z0p g0'v„` Ig2D2 S ti 0 I N 1 t� F@gl 1— bIA. `y o y j _ 5 00 5047337d6' V.� Y�MP c Ci o ' �g 112,62 - - 112.62 112.62 - o �m 30 v YM9 � ��V Z YW �n S� rtO> W � O w '�U � m bNbb + 1 N� YOID bFlYn D e � 8Q t 'N3/•/� g 0T14T F ' 2: a � 0 113.801139 c ie is soE ROAD =. _' sbe 10 o 0o o h u iC `"�"m _ y Y z m z z o '.nz ' O luy qqq z 8 z n F_ U qZZ z o J A �nQ { R& eSP9 Kkz_ T o5 P L .>- N,aN 4S - : ift E 7g`-(s ! :1,rJE _ � l N 50.np -P.�2S.dG }#>{ : O 3g��{2` VG-LSr Roots 4, SCC.AQ p Zp aEp (p0 Bo O - — _ _ — C Audio-Visual Alarm • Cieanout ?-200 Galion Senflc Tai �(? 2-Corpar, aen:a�G_ y� Fluent�:irer , , Valve Conaol Boo s^ ; n yp' pe Ail 42'h�IP�AULA5JC VJJO4NSON ; '*' s✓ � g . t4a��1s>•en sl H�a" � � s9 AUG 19 9 226 -a T- 3W 4�� a. vc_ crud,•- Ic o-t u3Ud1.ZS � 35 � 4 . !'i t2S FeNer Lxa _ t It O C�9� '11 25 Leta¢ rscct II F I a J N I - t !d NiM:HE JH- AJd Derailed Drainfield Layout afsr S:dc 1 s 10' 0 IG 20 `ate VF UTA JOY JOHNSON m3� Types ce.a ara, UC�1JS� SION8m'. 12 I - F2< Feer< � Qp Gevr r i Gatle 45.aegce EC L.aaa 2-t/C- Q$'— +26' laud I I Erq 6 �' bl ceia - Oem Aa N>ta Cbavn ro b frm 0 ro 6 eem Cebu 30 I F-. - Gm. 1bk — adh Rate. Clevn Oa 4 t, R q a ev &d et Eam m:n Arrow Septic Designs Drainfield Cross-Section View (360) 898-2255 Net To Sale Length Length Orifice # Distance from Distance from Lateral# (In.) (Ft.) Spacing Orifices Feeder Line(In.) Cleanout(In.) 1 420 35 60 7 30 30 2 420 35 60 7 30 30 3 420 35 60 7 30 30 4 420 35 60 7 30 30 5 420 35 60 7 30 30 6 420 35 60 7 30 30 Total Lateral Length 210 Total#Orifices 42 GPM= 2478 Dynamic Head Calculations Selected residual pressure'. 2 ft' Length (Ft.) #Orifices Transport Pipe 110 42 120 ft. Feeder Total Lateral Line Length Lateral#1 35 2 37 7 0.11 ft. Lateral#2 35 11 46 7 0.13 ft. Lateral#3 35 20 55 7 0.16 ft. Lateral#4 35 29 64 7 0.18 ft. Lateral#5 35 38 73 7 0.21 ft. Lateral#6 35 47 82 7 0.23 ft. Total Elevation Lift 0.00 ft. Total Dynamic Head rr,7� 4.22 ft. t t. PAULA JOY JOHNSON iaSIANEk_ 1-Zo-2c CPC \J AUG j9 . IWASJ LU • aronze consrructon available(139 series) • High head'version available 145 series) v •> '' Double shaft seal versions a vailabte for added protection Flow-Mate on models 140/143. For more Information,see Technical Data Sheets FM2782,FM2783. In high head dewatering or effluent applications where pumping performance is critical, this robust familyofpumpsis lmcwn for reliability, \ durabit Ty and performance. These pumps are especially suited for harsh environments. Zoeder's cootrun design and corrosion-resistant,powder coated LA epoxy finish add cp to a bong-tasting, trouble-free product. APPLICATIONS: • STEP oronsieapoIications _ .. U.die transfer 'fight_omm d,cewaTering SPECIFICATIONS 11h"NP. d . age ea 1/2 HP thr h1HP MADE IN THE USA • Availa0le n auto tic Crnon somor tic nj Gi k,ptll. .III "i • Model 137,139,140'.1/2"(12 mm)spherical solids - capacity with vortex impeller • Model?45:3/4"(19 mm)spheric t solids capacity with vortex Impeller F \ _ PUMP PERFORMANCE CURVE MODEL 151 P152i 753 Dose-Mate This is our fastest growing line of effluent 4- 4 pumps.The JSO seriesis truly a workhorse I designed for reliability under extreme __ conditions in an effluent environment. It 150 series pump curves coverawide range of applications. They are well suited to t applications with tow pressure pipe(LPP) eJ LL and enhanced flow STEP systems.Zoeller's cool run design and corrosion-resistant, _ powder coated epoxy finish, in addition to the hermetically sealed, oil-filled motor and non-clogging vortex impeller add up to a long-lasting,trouble-free product APPLICATIONS: • STEP or°nste applications M H U o t�c • !fefit coca_ del dewater rig Y "Ali' L ; - [ "a SPECIFICATIONS: ?- 23 P ce • 1-1/2"NPT discharge t i 99 y r...4 a.•} • /10 HP h /2 HP if • AvailauLe In nonautomaticorwimavondble level AUG 93, t� ] pipe back mechanical switch , e.. • 1/2"112 mm)spherlcal solids capacitywith vortex thermoplastic impeller For more information,see Technical Data Sheet FM2784. ALt rights reservee. ?OELLER PUMP CO. 1502-778-2731 1800-928.7857 zoelierpuopscom 9 i F2011 FSSAA �3Aa I MEg TA1(K s i mi etas -- r'�' tjj MM S'EPT:L -�Ta WtAaff�.D TAM N • P i Ef {�{ r YAWE i H.�@S WASSIALARM LEVEi d MalowTD=a"iar3 MMUMTS a: AUG 1 9 ' --' i amm i iF >.-_. r 24, 2720 AS G 2 arc . Se. ` r of8 (liataw- Septic 2)eoigno, Sec. r� INSTALLATION& MAINTENANCE Pressure Distribution Systems y PAULA JOY 4OHNSON 1. Install Laterals with contour of the ground. �; -T�--�-v-- 2. Install trench bottoms level. '7 ate 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. 8. Install 1/8"mesh non-corrosive pump screen(min. 12 sq. ft. surface area, not to interfere with controls or floats.) Or pump screen may be substituted with Bio-Tube in septic tank and block under pump. Pull bio-tube every 6-12 months and flush back into tank. 9. Install anti-siphon valve above pump in pump chamber to prevent the pump chamber from siphoning into the drainfield. 10. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 11. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue), after pressure test and Environmental Health Dept. approval,turn orifices down(6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 12. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade, run the filter fabric at least 2 inches down the trench wall. 13. Waterlines must be a minimum of 10' to any tank or drainfleld(a reduction to 5' may be obtained with a State waiver on lots that meet minimum lot size). Encase all water lines within 10' of septic transport lines and under any driveway/parking areas. 14. Divert all storm water runoff away from on-site sewage system. 15. \o curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 16. Have the septic tank and pump chamber pumped or inspected every 3 years minimum. 17.No vehicular traffic over drainfield area or tanks. 18. Inspect floats, clean filters, and test high water level alarm every 6-12 months as needed. 19. All materials and workmanship must meet County and State regulations. 20. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Deparmient will make this design null and void 21. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 22. All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning. Ensure anti-siphon hole sprays down/away from tank opening. ?3. All transport lines under driveways or parking areas must be encased to prevent crushing. 24. Homeowner is responsible for all property lines and eas n t y i g 6 AUG �o