HomeMy WebLinkAboutSWG2020-00135 REVISED - SWG As-Built Mason County OSS Installation Report pg. 1 MASON COUNTY PUBLIC HEALTH APPLICANT/ PERMIT INFORMATION Permit Number SWG 2020-00135 Parcel# 22310-79-90663 Applicant Name Frank&Suze Marcinko Subdivision (Name/Div/Block/Lot) Applicant Address 5677 Minnig LN NW Tract 3 of SP#2795 of#635388 City, State, Zip Seebeck,WA 98380 Installer Name F Marcinko Allied Septic Design an Site Address 797 NE Blacksmith Dr, Belfair Designer Name Frank Marcinko INSTALLATION CHECKLIST Q Full System Installation ❑Tank(s)Only ❑ Drainfield Only ❑Repair ❑Other System Type Pretreatment Type >5 ft. from foundation? - - - - - - - - - -- - - - - - - - - - - - - - - - ❑ NIA ® YES ❑ NO >50ft. from wells? . - _ - - - - - - - - - - - - - - - - - - - - - - - - - - ❑ ® El Z >50ft. from surface water? - - - - - - - - - - - - - - - - - - - - - - - - ❑ ® ❑ Cleanout between building and tank? - - - - -- - - - - - - - - - - - - - ❑ ® ❑ U Tank baffles present? - - - - - - - - - - - - - - - - - - - - - - - - - - - ❑ 0 El 24'access risers over each compartment? - - - - - - - - - - - - - - - ❑ ® ❑ W Effluent filter installed?- - - - - - - - - - - - - - - - - - - - - - - - - - ❑ ❑ N Septic tank size 125O gal Manufacturer Hagerman Pre Cast C D-box water level and speed levelers used? - - - - - - - - - - - - - - - ® NIA ❑ YES ❑ NO 0O Manifold/D-box accessible from surface?- - - - - - - - - - - - - - - - - ❑ 0 ❑ mz Check valves installed? - - - - - - - - - - - - - - - - - - - - - - - - - ❑ El OQ 2 Transport Line Size 2" Schedule/Class Son 40 Bedrooms installed (check one) ❑ 2 ❑3 ❑4 ❑ 5 ❑6 ❑Commercial/Other >10fl. from foundation?- - - - - - - - - - - - - - - - -- - - - - - - - - ❑ NIA ® YES ❑ NO a 1100ft from wells?- - - - - - - - - - - - - - - - - - - - - - - - - - - - - ❑ ® El m >100ft. fromsurfacewater? - - - - - - - - - - - - - - - - - - - - - - - ❑ ® ❑ LL >1oft. frompotablewaterlines?- - -- - - - - - - - - - - - - - - - - - - ❑ ® ❑ QZ > 5ftfrompropertylinesandeasements?- - - - - - - - - - - - - - - - ❑ ® ❑ > 30 ft. from downgradient curtain/foundation drains? - - - - - - - - - ® ❑ El Drainfield level and observation ports present - - - - - - - - - - - - - - • Graveless chambers or ❑ Clean gravel used? (check one) Proper cover installed overdrainfield?- - - - - - - - - - - - - - - -- - - ❑ 0 ❑ Pump tank setbacks consistant with septic tank? - - - - - - - - - - - - - ❑ NIA ® YES ❑ NO Pump tank size 1OOO gal Manufacturer Hagerman Pre Cast F24' access riser(s)and accessible from surface?- - - - - - - - - - - - - ❑ N ❑ C Alarm or Control Panel Installed? - - - - - - - - - - - - - - - - - - - El 9 El f Control Panel equipped with Timer/ ETM/Counter- - - - - - - - - - - ❑ E ❑ 7 0- Pump installed in • Bucket or ❑ On Block or ❑ Other IL Pump Make/Model Liberty 280 e Floats or ❑ Transducer Tank draw down 1 314 in/min Pump capacity 35 gpm Squirt Height 4 ft Pump on time I min 40 sec Pump off time 4 hours Daily flow set at 360 gpd Updated moots Mason County OSS Installation Report pg. 2 Parcel# 22310-79-90663 ABANDONMENT RECORD Were existing septic components abandoned as part of this project? - - - - - - - -- - -- - - - - YES Q NO If yes, please describe'. Were all components pumped out and properly abandoned per WAC246-272A-0300? - - - - - -- E YES NO RECORD DRAWING Thus is a permanent record and must be accurate and descriptive enough to relocate In the need of maintenance activities and future development. Typical Record omwmgs contain: oram0ela a manifold orientation a layout.Septcpump lank location North arrow.reserve d2mneld.exiling and proposed buildings location of wells.waterlines. ells observation pods cloanoule and other maintenance access points. Incomplete ReCad Drawings may create additional delays in final installal,on approval and related permits. eY( c fP 1 R ®C ® Record Drawing Attached CERTIFICATION OF INSTALLATION INSTALLER DESIGNER/ENGINEER I certify that I installed the system in accordance with I certify that the system has been installed in accor- the septic design stamped "APPROVED' by Mason dance with the septic design stamped"APPROVED"by County Public Health and that any deviations shown Mason County Public Health and that any deviations here have been cleared/approved by both the designer shown here have been cleared/approved by both and Mason County Public Health and meet all State myself and Mason County Public Health and meet all and Mason County Codes. State and Mason County Codes l further certify that al/information contained on this 1 further certify that al/information contained on this form and attached Record Drawing is accurate, form and attached Record Drawing is accurate. 08/13/26 Signature of Installer Date Frank Marcinko -, \ Printed Name of Signee d , MASON COUNTY PUBLIC HEALTH �e The undersigned approves this Installation Report and �gC} 201ODBOO Record Drawing on behalf of Mason County Public ? FrnkA I .M... Health: LICENSED DESGIER O Signature of Environmental Health Specialist Date (stamp, signature and date) THIS FORM MAY BE SCANNED ANDAVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEB SITE updnen erzt.In (Wellradius for -79-90664 I +0'el 184.83' A oaa rO\ a 3�1� ''d c`0 µsRa 0Qoa a it �g6 O : \ E_ _�- Tank y�� Pump 5e 6 a MI o � � Water Line For Reserve 1�Nl Rados 2y. °° Adjoining P90661 e\\ '�M/ell zz310-]9-9066] b:.9- ,House aSLa 3 aa`�o ww .hO�F IV N w W O V 'vb i W owed 9tormwater Runoff Retention ..........: Area X' e Well �a�sc' Soayo�9¢ a�ou 's el 184.46' +9'el Building Site Plan Name: Marcink0 Tax Parcel: 22310-79-90663 F �i Scale = I" = 40' Address: 797 NE Blacksmith Or, Belfair P�' A;my sA 40100609 F Frank A.Matdnko LICENSED DESIGNER 0 13 26