Loading...
HomeMy WebLinkAboutBLD2026-00405 - BLD CD Environmental Health Review - 8/17/2026 A SCALD 1 INCH = 40 FEET 0 5 10 20 40 PROPOSED ECOLOGY BLOCK WALL. SEE DETAILS, PROPERTY LINE EXISTING DRIVEWAY c,J �3F EXISTING DRAINFIELD EXISTING SEPTIC TANK SEPTIC RESERVE AREA A OIT EXISTING HOUSE �i a /" EH APPROVED Rhonda Thompson 08/17/2026 EH Setbacks A.) Drainfield/Reserve requires 10' setback from footing/foundations CLYD PROJECT/ OWNER/ LOCATION, Septic tank(s) requires 5' setback from all footing/foundations PAGAC RETAINING WALL B. P q 9 DESIGN C.) No foundation/Perimeter Drains within 30ft, downgradient of PAGAC Drainfield/Reserve area 51 NE ALLEN COURT No Cut Bank(s) (greater than 5ft and over 45 degrees)within PARCEL 22336-53-00047 D. g ) MASON COUNTY WASHINGTON 50ft, down gradient of Drainfield/Reserve area r 43O45 ENGINEER: E.) Use approved mitigation from section C1-9 of the department of :r�, -�ts-rea� \r' ENVIROTECH ENGINEERING ecology's "Criteria For Sewage Works Design," when sewer PSS,ONALF'''u BO FA ROX 9 84 EL WASHINGTON 98528 transport lines are within 1 Oft of water supply lines. 360-275-9374 s/lo/26 SITE PLAN - SH 1 OF 3 2'X2'X4' MIN CONCRETE MODULAR BLOCK WITH INTERLOCKING COMPONENTS LEVEL BACKFILL e a. m. .. 4 a < 4 NATIVE ° e e SANDY ° ° S❑ILS a °e 4 IIMlIMl C❑MPACTED 6" LEVELING COARSE OVER UNYILDING, UNDISTURBED SUBGRADE 6FT MAX MODULAR BLOCK WALL G CLYbE PROJECT/ OWNER/ LOCATION NOT TO SCALE � `LYD s� PAGAC RETAINING WALL DESIGN PAGAC � 51 NE ALLEN COURT PARCEL 22336-53-00047 MASON COUNTY WASHINGTON 4O45 r ENGINEER: Q. ( -V ENVIROTECH ENGINEERING �Sq�t BE BOX 984 BELFAIR, WASHINGTON 98528 360-275-9374 6/26/26 DETAILS - SH 2 OF 3 N❑TES: 1, BL❑CKS SHALL BE MIN SIZE AS SH❑WN, EXCEPT 2 BL❑CKS MAY BE USED WHERE NECESSARY ❑N T❑P ❑F WALL AND ENDS, 4 INTERL❑CKING C❑MP❑NENTS REQUIRED. 2. LEVEL BACKFILL BEHIND WALL IS REQUIRED AS SH❑WN, 3. ALL W❑RK SHALL C❑MPLY WITH APPR❑PRIATE IBC, STATE AND L❑CAL C❑DES INCLUDING SAFETY FENCING AS NECESSARY. 4. DAMAGED BL❑CKS SHALL N❑T BE USED. ASSEMBLY ❑F M❑DULAR BL❑CK SYSTEM SHALL BE IN ACC❑RDANCE WITH THE MANUFACTURER'S REC❑MMENDATI❑NS. 5. BACKFILL SH❑ULD BE C❑MPACTED AS T❑ N❑T DISL❑DGE BL❑CKS. 6. BASE LEVELING C❑URSE SH❑ULD BE USED AND SHALL N❑T EXCEED 6 INCHES IN DEPTH, AND BE C❑MPACTED WITH HEAVY C❑NSTRUCTI❑N EQUIPMENT. 7. VEHICLES SHALL BE N❑T CL❑SER THAN 10 FEET FR❑M EDGE ❑F WALL WITHIN THE BACKFILL, 8. DRAINAGE ❑UTLETS ❑R INFILTRATI❑N FACILITIES ARE N❑T PERMITTED WITHIN AT LEAST 15 FEET BEHIND THE RETAINING WALL. 9. ALL MATERIALS, QUANTITIES, AND L❑CATI❑NS SHALL BE VERIFIED BY THE ❑WNER/ C❑NTRACT❑R PRI❑R T❑ C❑NSTRUCTI❑N. PR❑P❑SED WALL MUST BE STAKED ❑UT AND UTILITIES L❑CATED PRI❑R T❑ C❑NSTRUCTI❑N. ANY DISCREPENCIES SHALL BE REP❑RTED T❑ THE ENGINEER PRI❑R T❑ C❑NSTRUCTI❑N. a�L C LYO,F.ST PROJECT/ OWNER/ LOCATION: PAGAC RETAINING WALL DESIGN 6/26/26 PAGAC 51 NE ALLEN COURT PARCEL 22336-53-00047 MASON COUNTY WASHINGTON ENGINEER: ENVIROTECH ENGINEERING PO BOX 984 BELFAIR, WASHINGTON 98528 360-275-9374 DETAILS & N❑TES- SH 3 ❑F 3