Loading...
HomeMy WebLinkAboutBLD2026-00518-EH SETBACKS - BLD CD Environmental Health Review - 7/6/2026 Co - Coo5L O PROPOSED 3 BDRM RES NOTES: RESTRICTIVE LAYER BELOW: 32" SCALE: 1"-20FT �O 3 2O PROPOSED WATERLINE • FIVE TIMES RULE MET • ELAPSE TIME METER AND EVENT COUNTER REQUIRED t- 3 EXISTING DRIVE • RISERS TO SURFACE REQUIRED OVER ALL TANK LIDS � / 2 PROPOSED STUBOUT/CLEANOUT(IE.-95.8) • OPERATION CAPACITY OF THE SYSTEM IS 270 GPD / / O PROPOSED 1200GAL.SEPTIC TANK(IN.EL.-95.0/OUT.EL.-94.7) SOIL.LOGS: 1) VERY GRAVELLY LOAMY MED SAND 0-12" P�/ /� / 6 PROPOSED 1200GAL.PUMP CHAMBER(PUMP EL.-91.7) VERY GRAVELLY MED SAND 12-32 CEMENTED TILL 32"+ 75.0 / ! 1 77 HEADWORKS(SEE DETAIL PG 2) 2) VERY GRAVELLY LOAMY MED SAND 0-12" /�/, , VERY GRAVELLYMED SAND 12-32" N O GRAVELLY COARSE SAND 32"+ O 120'-1"SCH40 PVC SUPPLY AND RETURN LINES / N erimeter/foundation 3) VERY GRAVELLY LOAMY MED SAND 0-12" / / p PROPOSED 675FT2 DRIP DRAINFIELD(4-69FT LATERALS)-IE.-100.2) VERY GRAVELLY MED SAND 12-32" / drains within 30ft of O GRAVELLY COARSE SAND 32"+ /O� 10 PROPOSED 675FT DRIP RESERVE AREA 4) � upgradient drainfield ^� / O \ 170 6• / 11 LARGE FIR TREES 5) / / 12 RBM IS GROUND EL.@ PROPERTY CORNER(RBM=100.0) / ' ;' V SHED(REMOVE) 71 / / 100 \ / / 5 / J EXIS I G D.F.D.F.(ABANDON) �' TANK DETAIL-NO SCALE r / / J CIEANOIR LIO WITHOASTIOM REAL CN 24-ACCE88 RISERS ON 24•ACDEB9 RISERS LID VRT"GASTIGHT REAL WATERPROOFNNORDN BD% / V y INIB OMOE i � / ' � / , AI FROMS I K FLOAT / FROM SEWAGE 6 Y �• 60VRCE " Eg R NOEPENOENTFLOATBTEM FORFLOAT NpVNRNO 7 w. EIX VALVE �' / , / `` APPROVEDEFFLUENTF ER ATONCTOFF / PUMP ON BLOCK PORCH GR1NeKxouD EXISTING SEPTIC TANK(ABANDON PER CODE) ' / _ d ° . ' CONTOUR LINES PER GIS,REFER TO APPLICATION FOR PROPERTY ACREAGE. / NAVD88 ELEVATION IS UNKOWN 170.6 THIS IS NOT A SURVEY: �o - site features,topography,elevations and benchmarks are based on assumed datum I o 1 provided by,the owner and county planning records and are intended only for the review and construction of the proposed septic system design.Hunter Septic Design '1i • - recommends that a licensed professional land surveyor always be used to set corners, $ / establish lot lines,determine elevations and topography and/or provide a legal site plan. 75.0 A fee may be charged for final Inspection and record drawings EH APPROVED ' REVISION LOG: VERS ION-DATE Rhonda Thompson 07/06/2026 �rv,N��c EFT SETBACK FROM DRAINFIELD TO PROPERTY LINES E MASON LAKE RD TO A LEFT ON BALANTRAE TO SITE ON THE RIGHT. HUNTER SEPTIC DESIGN DESIGNER: EH Setbacks ADAM HUNTER PO'Box 1621 Olympia,WA 98507 SITE ADDRESS: A.) Drainfield/Reserve requires 10'setback from footing/foundations 360-890-27781 adem hunterse ticdesi n.com 340 E BALLANTRAE SEPTIC SYSTEM DESIGN FOR: B.)Septic tank(s)requires 5'setback from all footing/foundations Am �� 1„ J BO RUSSELL C.) No foundation/Perimeter Drains within 30ft, downgradient of (� ►`y 11, 81TELEGAL: Drainfield/Reserve area r 4 BALLA iRAE LAKE LIMERICK I LOT 87 • D.) No Cut Bank(s)(greater than 5ft and over 45 degrees)within 4- P 1) �� \ / (M N LAKE pARCELNUMBER: SITE/PERMIT#: PAGE: 50ft, down gradient of Drainfield/Reserve area (. 321275000087 1 0F2 E.) Use approved mitigation from section C1-9 of the department of 0 - ecology's"Criteria For Sewage Works.Design,"when sewer O transport lines are within 1Oft of water supply lines.