HomeMy WebLinkAboutBLD2026-00554 - BLD CD Environmental Health Review - 7/27/2026 z� O 3 F1O4 - rya -
a 5s�I
d
EH Setbacks
A.) Drainfield/Reserve requires 10'setback from footing/foundations
B.)Septic tank(s)requires 5'setback from all footing/foundations
C.)No foundation/Perimeter Drains within 30ft,downgradient of
Drainfield/Reserve area
D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)wit(tin
50ft,down gradient of Drainfield/Reserve area {
E.)Use approved mitigation from section C1-9 of the department of 'r
ecology's"Criteria For Sewage Works Design,"when sewer II VV g
transport lines are within 10ft of water supply lines. Zt�� a�ML .
EH APPROVED
Rhonda Thompson 07/27/2026 J.` �
2y
RR5 Zoning 0 ew
Front Yard Setback.25'. ���
Side&Rear Yard Setbacks.Residential dwelling
and accessory structures is 20'. /)
OR 10%width of lot if not more than 100'wide
OR approved ADV
6'minimum side yard set back NO PLUMBING
All setbacks are measured from the furthest —
projection of the building.
07/01/2026 r .' r
APPROVED /_Y
MASON COUNTY DCD PLANNING
Disclaimer:Mason County does not require a
survey to obtain a building permit.As a result,site
plans may not reflect accurate data.It is the
applicant's responsibility to comply with setback
requirements.
S€