Loading...
HomeMy WebLinkAboutSWG2026-00165 - SWG Application / Design - 7/27/2026 11IIAS®N C®LINTY 415 N 6TH STREET,SHELTON, ,WA 98584 • SHELTON:360-427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2026-00165 APPLICANT Hunter,Adam Phone: 360 753-1226 Address: 2201 93rd Ave SW Olympia, WA 98512 APPLICANT Ronald Lansing Phone: Address: 2291 E Crestview Dr SHELTON, WA 98584 OWNER CLD Group LLC Phone: 425-503-6121 Address: 301 E WALLACE KNEELAND BLVD STE 24 SHELTON,WA 98584 SEPTIC DESIGNER ADAM HUNTER* Phone: 360-753-1226 Address: PO Box 162 OLYMPIA,WA 98507 Site Address: 1480 E TRAILS END DR Primary Parcel Number: 222235106052 Permit Description: New 3bd ATU to subsurface drip Permit Submitted Date: 05/22/2026 Permit Issued Date: 07/27/2026 Issued By: Rhonda Thompson Current Permit Fees Paid: $570.00 (additional fees may be required upon installation of system). Permit Expiration Date: 06/30/2029 (based on date of inspection) Permit Conditions: I Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 7 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. • * trf1' OFFICIAL USE ONLY • MASON COUNTY DATERECENED: • AMOUNT RECE RECEIVED BY: C Cn Public Health & Human Services d r S 1 v Cl) Environmental Health 360-427-9670,ext.400 or 360-275-4467,ext.400 ice! r y�9S�^ (' C Cl) 415 N.6th Street-Shelton,WA 98584 S W G �0' �1 — 0 0 1 CC66// 0 Z CA ON-SITE SEWAGE SYSTEM APPLICATION APPLICANT PHONE m r Ronald Lansing 3608744699 z C MAILING ADDRESS-STREET,CITY,STATE,ZIP CODE E 71 E Dalkeith Rd Shelton WA 98584 M m SITE ADDRESS-STREET,CITY,ZIP CODE 1480 East Trails End Drive Belfair 98528 I N NAME OF DESIGNER PHONE I N ADAM HUNTER 3607531226 C NAME OF INSTALLER PHONE TBD TBD < N PERMIT TYPE(select one) DRINKING WATER SOURCE 0 I RFJ RESIDENTIAL OSS 5ICOMMUNITYOSS ❑COMMERCIAL OSS ❑ PRIVATE INDIVIDUAL WELL ❑ PRIVATE TWO-PARTY WELL z TYPE OF WORK(select one) PUBLIC WATER SYSTEM TRAILS END zNEW CONSTRUCTION/UPGRADES REPAIR/REPLACEMENT OTHER DETAILS(select all that apply) ❑ TABLE X REPAIR I SUBMITTALS ❑ SURFACING SEWAGE ❑ EXISTING FAILURE O SHORELINE W DESIGN FORM(REQUIRED) Q SEPTIC DESIGN(REQUIRED) BEDROOMS LOT SIZE WAS LOT CREATED AFT 4/ 025? I n❑ WAIVER(S)(IFAPPLICABLE) 3 0.41 YES NO I DIRECTIONS TO SITE AND SITE CONDITIONS:(ex.locked gate) TRAILS RD TO A RIGHT ON TRAILS END TO A LEFT ON TRAILS END TO SITE ON THE LEFT AT SIGN. I r O --1 SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. OFFICIAL USE ONLY BELOW THIS LINE UPGRADE/FAILURE SOURCE(for reporting purposes) ❑VOLUNTARY ❑MAINTENANCE/PUMPING❑ BUILDING PERMIT❑HOME SALE❑ COMPLAINT ❑OTHER: INSPECTOR SOIL LOGS COMMENTS I CONDITIONS - /2 ( s L 4 SOIL CODES: RECORD DRAWING AND INSTALLATION REPORT V=VERY G=GRAVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FORFINALAPPROVAL. INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSU DATE f 6 ( 3V/z') c141 7k 7k THIS FORM MA BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE Revised:01/09/2026 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 222235106052 A design will be reviewed when 3 copies of each of the following are submitted: Completed design form that has been signed and dated. ' Scaled layout sketch,including all applicable items on checklist. Scaled plot plan,including all applicable items on checklist. 'Cross-section sketch,including all applicable items on checklist. This form maybe scanned and available for public view on the Mason County Web site.Maximum paper size: 11"X17" PARCEL IDENTIFICATION Permit Number: SWG 7, " 0O c Designer's Name: ADAM HUNTER Applicant's Name: Ronald Lansing Designer's Phone Number: 3607531226 Mailing Address: 71 E Dalkeith Rd Designer's Address: 2201 93RD AVE SW, STE A Shelton WA 98584 City State Zip OLYMPIA WA 98512 City State Zip Designer's Email ADAM@HUNTERSEPTICDESIGN.COM DESIGN PARAMETERS Treatment Device 0Glendon OSand Filter OMound QSand Lined Drainfield Recirculating Filter 4J ATU BNR500 ❑Other Treatment Level(check all that apply): ❑A 4 B ❑C ❑BL1 46 BL2 J6 BL3 46 E N Drainfield Type ❑Gravity Pressure ❑Trench ❑Bed Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 Schedule/Class DRIP Daily Flow:Operating Capacity 270 gpd ✓ Length 116 ft Daily Flow:Design Flow 360 gpd Diameter 1/2 in Septic Tank Capacity(working) BNR500 gal Number 4 Receiving Soil Type(1-6) 4 Separation 1.93 ft Receiving Soil Appl.Rate 0.6 gpd/ft2 Orifices Required Primary Area 675 ft2 Total Number of Orifices 464 Designed Primary Area 696 ft2 Diameter DRIP in Designed Reserve Area 900 ft2 °' Spacing 12 in Trench/Bed Width 29 ft J' Manifold Trench/Bed Length 24 ft Schedule/Class 40 Elevation Measurements Length 20 ft Original Drainfield Area Slope 8 % Diameter 1 in New Slope,If Altered 8 % Preferred manifold configuration used? Yes ONo Depth of Excavation Up-slope 10 in / Transport Pipe from Original Grade Down-slope 6 in Schedule/Class 40 Designed Vertical Separation 12 in Length 20 ft Gravel-based Drainfield Required? 0Yes®No O Diameter 1 in Pump Required? ®Yes ONo Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 12 Diff. in Elevation Between Pump&Uppermost Orifice 9.5 ft Dose quantity 30GAL gal Drainfield Squirt Height/Selected Residual(head) 57.8 ft Chamber Capacity(flood) 1200 gal Uppermost Orifice®Higher OLower than Pump Shutoff Pump controls:Please check those required. Capacity @ Total Pressure Head 11.2 gpm Timer 66 Elapse Meter i1 Event Counter Calculated Total Pressure Head 93.1 ft If Timer: Pump on 30GAL ,Pump off 2HRS Comments A O V E 0 JUL 2 7 2026 2J[I jL)U11 1 cNvftcL A IL hLiRevised:6/11/2025 RET DESIGN FORM—PAGE TWO Assessor's Parcel Number:222235106052 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch lT Test hole locations t Drainfield orientation and layout Reference depth from original grade: UI Soil logs if Trench/bed dimensions and l?f Septic tank Property lines critical distances within layout ' Drainfield cover UI Existing and proposed wells UI D-Box/Valve box locations Reference depth from original grade within 100 ft of property UI Septic tank/pump chamber and restrictive strata: UI Measurements to cuts,banks, and locations UI Laterals,trench bed,top and surface water and critical areas Observation port location bottom Location and orientation of 10 Clean-out location UI Curtain drain collector curtain drain and all absorption 11 Manifold placement UI Sand augmentation components Orifice placement Other cross-section detail: if Location and dimension of � UI ports/clean-outs primary system and reserve area Lateral placement with distance Observation to edge of bed Other Information UI Buildings Audible/visual alarm referenced Yes No Direction of slope indicator ' Scale of drawing shown on scale E ! 0 Design staked out Waterlines bar if 0 Recorded Notices attached Roads,easements,driveways, Q' Elevation benchmark and relative if ❑ Waiver(s)attached parking elevations of system components UI 0 Pump curve attached North arrow and scale drawing UI ❑Evaluation of failure shown on scale bar Non-residential justification ❑ ❑ Waste strength ❑ ❑ Flow DESIGN APPROVAL The undersigned designer must be notified by installer at time of installation ®Yes O No 5/22/26 Signature o Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regulations: Environmental Healt 7 fz- i/24 Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. ;0 ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Revised:6/11/2025 Fill in the vleiet shaded cells.Output Information writ automatically be calculated and shown.In blue-shaded The Netafim elollne°CeleUI to esdheat es the amount of Blogne neetletl cells,0o not attempt to enter data Into or blueshaded cells,Irwin erase II,e`tom uI and potentially Impact to install a wasteweter drip dispersal system along with other design other output data,To save your Information ace,tut tile let future reference or submittal,fill In the Information parameters.It Is NOT Intended to replace a professional design,and General lnsbucfions•- in tile prelnuvon me end address fields below.The name you choose for"Job Namefflomeoweer"will should be used for estimating purposes only.Always consult with a become the name of the.txtfile.It will be saved on your computer when yen click the"Save to File"button at professional designer.Do not use this program with other bands of the bottom of the sheet A file folder will be created for you caged"Netafim"and the file will be stored there. products, -• F rexample,ifth Job Name IH toowner form proJectis Mr&M Jones,.all lye In term abon will be.. " - saved Ina file folder called"Netafim"and the tile in this folder will b celled"Mr.&Mrs.Jenes.t r, Netafim Bioline®Dripperline Design Recommendations-Based on Soil Loading Rate Job Name I Homeowner: RONALD LANSING Address: 1480 E TRAILS END DR. City,State,Zip: BELFAIR,WA Permit Agency: MASON COUNTY EH Installer Name: TBD Designed By: ADAM HUNTER Data: 5/222026 CD •. • G hoes Per Day' SBD __ Total System Information C7 Application Area Required(square feet)r 696 O S Leading Rate Gallons/Sq FLIPer Day,(GPD])� �a 51 T2_ _ Total Amount oIS I Re glared(feat)� 464 Total Number of Emitters in the Dripfieltl 464 '• ", SelectE itter Fl w Rate(GPH) !42 ^ - _ Zone Interrelation �-'•a Select EnutterSpacing(inches)) 12 Number of Zones 1 ®Ldp➢ W _ Arrount of Bioline°Par Zone(taut) 464 f Flush Velocity(fpa)i 2.5 Number efEmitiere Per Zone 464 r¶ •`)] Minimum Number of Laterals Per Zeno J + MUoimumhcwberefLateraiopenZene 11 Estimated Pump Flow Rating(GPM) 20 Number of Cereals That WI he Used 4 -` I® Maximum Length of B'abne°Laterals Based en mini Pr re 161 QgT Inlet Pressure(psi). __.. .ES_ ..i5 _ Flow Rate Pee Zone(GPM) SZ Z rte] Holding Capacity of Dnppedino Per Zone(Galin) 6,2 inlet P ure(F,eat ofHead)`_,57b_�_ Additional Flow Requirement to Accommodate RushingVeloub ILD R wSpacingB hse Dipine (f t)I„ 111 Helding Capacity of Piping _ Holding Capacity(Gallons)of Supply Lien&Supply B Flush Manifolds 19 Number of Ze _,_7 .__ Holding Capacity(Gallons per Zone)of Online 6.2 Holding Capacity(Gallons)of Supply Une,Man folds and Dripped'neC8-U r Hours Par Dey to'Use foiy DosingL___ 24;_.___. _ _ Head Loss Data-Dosing&Flushing Cycle Elevation Change form Pump toAase,Tank Outletp t( �_4,_._,.,__ Frction Loss per 100'(psi)in Supply Llna&Manifaltla 1.0 Velocity(fps) 4.2 Elevation Change from Dose Tank to Drip Feld(feet)E -5.5._ Friction Loss in Supply Line&Supply Manifolds(psi)) 1.2 - ' _ m. - Friction Loss in Supply Una&Supply Manifolds(Feet of Head) 2.8 Length of Supply Line&Supply&Flush Menif6ldo(f qt.._-.__40.__-__ Additional Pressure Required for Return Manifold and Piping to Tent(p01)1 10.0 Additonal Pressure Required for Return Manifold and Piping to Tank(Feet of Heed)) 21,1 - TDH(Total Dynamic Head)in Feat of Head l l.1:... -. Type of Pipe-Supply tire&MenUoido .. ,tT/.C.ielr4O ; Control Settings Information Total l SIZ of Supply&M nddld Pipe(in h s) 1 _ TohalRu timePerZ nePer Day(Mtea)nur7tt Total system Dosing Events Par DayIll�tz 05/22/2026 Pip R gnness C n tents. ,,.., 150 „- _._ Runtime For Each Dose(Minutes) 9 ,.� •' Y as�x" ^ -• _ OtlTma Between Doses in me Same Zone(Houw to nearest 0L.1 td InsIdeD tar of Ppe( in s)__ 1049 v �_ t - Miscellaneous Information Numberof Daily Dosing Evente Per Zone +"12 Dosing Volume Per Emitter Par Dose(gallons)" 0.07 uvim•' •.'1,• ' Inches Per Week oho os ng 5.81 Volume of a Single Dose(gallons) Pump Selection .; I: a '•..J, Pump Flow Feel ) 11.2 J TDH(Total Dynastic Heed in Feet Head)of -_ 85.1 rz �•`• Pump Manufacturer ORENCO _ ADA.1 11UNTER `•� Pura Model PF-1005 I _ Jiirr71r7i1RiI7 Using a Pump Curve A pump curve helps you determine the best pump for your system.Pump curves show the relationship between flow and pressure(total dynamic head or"TDH"),providing a graphical representation of a pump's optimal performance range.Pumps perform best at their nominal flow rate.These graphs show optimal pump operation ranges with a solid line and flow rates outside of these ranges with a dashed line.For the most accurate pump specification,use Orenco's PumpSelectTM software. Pump Curves 500 --I400 PF10 Series,60 Hz,0.5-1.O hp PF20 Series,60 Hz,0.5-1.5 hp 400 _ 350 PF2015 PF1010 ,_ ,e 300 300 PF1007 liii0 250 PF2010 - 250 - PF1005 m — 200 v 200 150 PF2005 150 -- - - - - - 10 100 '•. 50 50 0 0 2 4 6 8 10 12 14 16 18 0 5 10 15 20 25 30 35 40 Flow in gallons per minute(gpm) Flow in gallons per minute(gpm) 900 \ � PF305o PF30 Series,60 Hz,0.5-5.O hp AP PRO O 800 Q c JUL 27 2026 700 -- --------j ASON COUNTY ENYIRONMEN�AL HFALTI'1 600 RET PF3030 .... ....... 500 iiiii 05/22/2026 400 PF3020 C 300 PF3015 �,`'; PF3010 v' - POAI.IJ HVYTEF .y 200 '•11P1'i..", tiISi:1,z IF:�.. ........ .... ...• PF3005 0 0 5 10 . E1 5 20 25 30 35 40 45 Flow in gallons per minute(gpm) NTD-PU-PF-5 Orenco Systems®•800-348-9843•+1 541-459-4449•www.orenco.com Rev.3 O 01/21 Page 4 of 5 1O PROPOSED 3BDRM RED NOTES: SCALE:1"=30FT RESTRICTIVE LAYER BELOW: 22" n 2O PROPOSED WATERLINE • FIVE TIMES RULE MET 1" ELAPSE TIME METER AND E COUNTER REQUIRED 3 PROPOSED DRIVE RISERS TO SURFACE REQUIRED OVER ALL TANK LIDS l PROPOSED STUBOUT I CLEANOUT(IE.-95.0) • OPERATION CAPACITY OF THE SYSTEM IS 270 GPD TT SO PROPOSED NUWATER B06500 IN APPROVED ATU TANK(IN.EL-94.5/OUT.EL.-94.2) SOIL LOGS: 1) GRAVELLY SANDY LOAM 0-22" PROPOSED 1200GAL PUMP CHAMBER(PUMP EL.RI.2) TILL 22"t 7O HEADWORKS(SEE DETAIL PG 2) 2) GRAVELLY SANDY LOAM 0-2? / 4 TILL 22"+ 11 / O 40'-PSCH405UPPLY/RETURNUNES / 3) GRAVELLY LOAMY MED SAND 0-2Y ( / PROPOSED DRIP DRAINFIELD(695FT2-4.116FT LATERALS)(10.-100.0) TILL 22". / I 10 900FT DRIP RESERVE AREA 4) // I it BUILDING SETBACK LINE 5) I 12 REM IS GROUND EL.®PROPERTY CORNER(REM=100.0) / I ' 6' i I � 7) a I / / /I /I TANK DETAIL—NO SCALE 2E,.7 6 % 60.0 I i / o D CD 28.0 2 C / 6 CONTOUR LINES PER GIS,REFER TO APPLICATION FOR PROPERTY ACREAGE. / I24I / (/� �7 NAVD68 ELEVATION IS UNKOWN 101" 9Fr / 7 / I O ® THIS IS NOTA SURVEY: < 3 I '\ Z f V site features,topography,elevations and benchmarks are based on assumed datum 3 O provided by the owner and county planning records and are intended only for the review 12 �\ i_ _ _ _ _ _ i __ _ I_53.5 m CD < and construction of)he proposed septic system design.Hunter Septic Design — — O7 recommends that a licensed professional land surveyor always be used to set corners, 0512212026 establish lot lines,determine elevations and topography and/or provide a legal site plan. JAe / I = Y,., r A fee may be charged for final Inspection and record drawings -' `5rJ - REVISION LOG: 1 r— �•(• Jil VERSION-DATE 188.7 E TRAILS END E TRAILS RDTO A RIGHTON ETRAILS END DR TO A LEFT ON E TRAILS HUNTER SEPTIC DESIGN DESIGNER: END DR TO SITE ON THE LEFT. ADAM HUNTER PO Box 1621 Olympia,WA 98507 360-890-2778/udam@hanterse ticdesi n.com SrrEADOREsS: SEPTIC SYSTEM DESIGN FOR: 1468 E TRAILS END DR TRA RD RONALD LANSING SITE LEGAL TRAILS END#2 BLK 6 LOT 52 T ILSENDDR PARCEL NUMBER: SITE/PERMRC: I PAGE: 222235106052 1OF2 END DR DRIPFIELD SCHEMATIC 1 .2 FLEX PVC, Tu(:nvC Finish Grade I ______________________ _________________________ Residence S�PH tine I I I— I I See Spea Flush line tor Depth Q IPLlAIE' II— 1 — . 71, ineN ........ fielaRMBiehne (12'EAf/TTERSPACING) —) — e 7 �HEADWORKs Nr/Varwm1/2" hMPT X .BBRSED ReOefVahre NetafindBiolineDripperline RAMA MALE ADAPTEP.Flex Pipe BlOline Male Adapter(TLO5OMTL075MA) 1/2' FPT PVC ADAPTER — A/PVCSCH40 SxFPT Adpt ..•....•.............•.........................•. fefne Supply or PVC SCH40 SxSx5 Tee' .............. PP Flush Manifold DRIPLINE ne�� ...........................�.F.................. Fe wacpnnepuon 1.93FTi .......................................................... push Una P LOOP CONNECTION SCN4aOV HEADWORKh SETUP INSTRUCTIONS: ' ••••°°°••••°• •••`••"' °•""•'•"'••'••°'°•"°"°'°•'•• 1. Flshthe entirepiping networkI• \ UL n With the pump sLl conning slowly dse the field gush valve.Once Ua needle en the pressure ueges staealze, . .: \ O� 7 26 remN theoI on dedto, seing• 2U D now ate WaBm eeeded rotU gat eemings. g:....................................................... ONCOON3. Neat mk t U n,,to fe by Zing b g the nu his now sappy ui eflo mnroNons by 105Pwadene.Ae0 • the dosing eowrate from step 2 te the gushing flow rate.This raw mmulaee 11005 tale Is Ue minimum needed to •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• \ EN RON05/2 212 026 eddeveedegas I,smudn.velWyth Ue entlre a1w,slm wly ntlreenatun system 6dosed. NE MENTA y� 54.. wMoretpump is mnni g.openthe field nosh ve osewy untoegr Ue reWmthessurogauge eeds 10psi. HB. Now emrd the now date Umugh the flow mater,Ils1roWd he greaterthan the nev mmalaW.novate agolred in step a.Morels oener.................................................................. NrlVamum \ ��x Relief Valve \ riii (car,e(''.' /iii e•g i itI iii T7i /iiii/ ii e \ ,� s e •t•l'?iv'1^i 1L2 eamg" - - - •]T?SCllll�ll•2�• fi TfiY1•. i �/ Iron RtlO v/ ,de; ldrur /i>l RISERS ARE REQUIRED TO OR ABOVE FINISHED GRADE OVER TANK LIDS.IF GROUNDWATER OVER THE TOP OF THE TANKS IS A CONCERN DRIP NOTES: �/ �iiijjj!/�.•�` "'°" ace 1 //7 /�I'S^+ 0e THEN HIGH GROUNDWATER RATED TANKS WILL BE REQUIRED.THE RISERS MUST BE SEALED WATERTIGHT AT THE JOINT BETWEEN TANK -/j /// �� -► to rKM AND THE RISER. • DRIPLINES TO BE INSTALLED 6° BELOW EXISTING GRADE AND 1.93FT ON CENTER % L 1T —u>.`�'•S DRIPLINES TO BE INSTALLED USING A NARROW SHOVEL OR TRENCHING TOOL %/j/ U-S00 e51 jj DRIPLINES TO BE INSTALLED LEVELAND PARALLEL WITH CONTOURS ttMbni GENERAL NOTES . /// SUPPLY AND RETURN LINE IS 1' SCH40 TO BE INSTALLED 6°DEEPER THAN DRIPLINE ON EN V� I/iu>- ANY ao 1. ANY VARIATIONS TO THIS DESIGN SHALL FIRST BE APPROVED BY JIM HUNTER&ASSOCIATES AND THE COUNTY SANITARIAN. AF DRAIUUIELD /j/� AIR VACUUM BREAKER VALVE TO BE AT END OF SUPPLY LINE AT HIGHEST ELEVATION IN A VALVE "/// 0 �•• icon Rmp 2. OWNER INSTALLER SHALL NOT REMOVE OR DISTURB ANY TOP SOIL WHILE CLEARING TREES AND STUMPS IN ORAINFlELD ARFA BOX REMOVAL OF TOP SOIL COULD RENDER SITE UNUSABLE. • FLEXIBLE CONNECTING TUBE TO BE BETWEEN DRIPLINE AND SUPPLY LINE j��/ - i��i•*N', %j i/� • EARTHEN DAMS TO BE CONSTRUCTED AT END OF CH LATERAL TO PREVENT DRAINBACK / /�///i /// i, u•damn EA 3. OWNER SHALL BE AWARE OF THE POSSIBILITY OF TANKS FLOATING OUT OF THE GROUND SHOULD THE TANKS BE PUMPED EMPTY // MAr,I law • DRIPLINES:NETAFIM BIOLINE SELF CLEANING PRESSURE COMPENSATING EMITTERS ///j/// DURING SEASONAL HIGH WATER TABLE CONDITIONS. • CHECK VALVE AND HIGH LEVEL ALARM REQUIRED IN PUMP TANK ///////•i/ .�j j///////i� 4. ALL CONSTRUCTION MATERIALS AND THE INSTALLATION OF THE DESIGNED SEPTIC SYSTEM SHALL CONFORM TO ALL APPLICABLE TIME DOSING OF DRIP SYSTEM REQUIRED AT 2 HOUR INTERVALS 1 30 GAL.DOSE) • DOSE COUNTER AND ELAPSE TIME METER REQUIRED CONnNUOU5 FLUSN nmaowDRxm FROM RO FOWLER STATE AND COUNTY HEALTH DEPARTMENT REQUIREMENTS. • ALL VALVE BOXES TO BE ACCESSIBLE TO SURFACE • RISERS REQUIRED OVER ALL TANK LIDS 5. USE OF SOME RESERVE DRAINFIELDS MAY NECESSITATE PUMP,SAND FILTER,MOUND OR PRETREATMENT INSTALLATIONS. • FOWLER CONTINUOUS FLUSH HEADWORKS REQUIRED HUNTER SEPTIC DESIGN DESIGNER 6. THE ADDITION OF AN APPROVED EFFLUENT FILTER IN THE SEPTIC TANK IS REQUIRED TO ENSURE THAT SOLIDS DO NOT PASS TO THE • VACUUM BREAKER VALVE:NETAFIM 1•COMBINATION#65ARIB1 ADAM HUNTER 2201 93rd Ave SW!Olympia,WA 98507 • USE T TO T CONSTRUCTION GRAINFIELD CAUSING PREMATURE DRAINFIELD FAILURE AND COSTLY REPAIRS, • CHEMICAL INJECTION PORT REQUIRED(TYPICALLY IN THE CONTINUOUS FLUSH HEADWORKS) 360-BSS-2778 1 adam@huotergoplicdeolgn.com SITE ADDRESS: 7. ALL REQUIRED TESTS SHALL BE SUCCESSFULLY RUN PRIOR TO CALLING JIM HUNTER&ASSOCIATES FOR FINAL INSPECTION,ALL • PUMP MODEL: ORENCO PF1005 1460 E TRAILS END DR SEPTIC SYSTEM DESIGN FOR: COMPONENTS,INCLUDING TANK ACCESS LIDS MUST BEACCESSIBLE FOR INSPECTION.CONTRACTOR SHALL BE RESPONSIBLE FOR RONALD LANSING SITE LEGAL COST OF RETURN INSPECTIONS DUE TO FAILED TESTS OR INACCESSIBLE COMPONENTS. TRAILS END#2 ELK 6 LOT 6. THIS IBA SPECIAL DESIGN DUE TO ADVERSE SOIL CONDITIONS,GROUNDWATER TABLE AND I OR TOPOGRAPHY.JIM HUNTER& PAGE: ASSOCIATES HAS DESIGNED THIS SYSTEM IN ACCORDANCE WITH ALL STATE AND COUNTY HEALTH DEPARTMENT REQUIREMENTS AND PARCEL NUMBER: ]7EIPERMI14: 2 OF 2 ASSUMES NO RESPONSIBILITY FOR ITS USE OR LONGEVITY.THE OWNER THEREFORE AGREES TO MAINTAIN AND MAKE ALL NECESSARY 222235106052 REPAIRS TO THE SYSTEM AT NO COST TO JIM HUNTER&ASSOCIATES.