Loading...
HomeMy WebLinkAboutBLD2026-00518 - BLD CD Environmental Health Review - 7/6/2026 � Cc 6 O PROPOSED 3 BERM RES NOTES: . RESTRICTIVE LAYER BELOW: 32" ¢� FIVE TIMES RULE MET SCALE:1"=20FT O 3 O PROPOSED WATERLINE �,rr'c ELAPSE TIME METER AND EVENT COUNTER REQUIRED 1° 3O EXISTINGDRIVE . ' • RISERS TO SURFACE REQUIRED OVERALL TANK LIDS QQ 2 PROPOSED STUBOUTI CLEANOUE(IE.-95.5) • OPERATION CAPACITY OF THE SYSTEM IS 270 GPO PROPOSED 1200GAL SEPTIC TANK ON EL•06.0/OUT EL-e/T) SOIL LOGS: 1) VERY GPAVELLY LOAMY MEO SANG 0-12° / O VERY GRAVELLY MED SAND 12.32° PROPOSED 1200GAL.PUMP CHAMBER(PUMP EL-01.7) . CEMENTED TILL 2) VERY GRAVELLY LOAMY MED SAND 0-12` 76.0 \ ,r / 1 O HFADWORKO(SEE DETAILP02) /W 1 VERY GRAVELLY MED SAND 12.32• � No O' 12d-1•SCH4°PVC SUPPLYAND RE URN LINES ORAVELLYCOARSESAND 0-22_1 / 3) VERY GRAVELLY LOAMY MED SAND perimeter/foundation VERY GRAVELLY MED SAND 12-32` O PROPOSED 876FT2 DRIP DRAINFIEID(4-BBFT LATERALS)-IE-100.2) GRAVELLY COARSE SAND 32i / / drains within 30ft of a) / / upgradient drainfield 10 PROPOSED 675FT DRIP RESERVE AREA / $ 170.6• 11 LARGE FIR TREES 5) o/ RBM IS GROUND EL.@PROPERTY CORNER(RBM=10°.0) B) ' // // / / �ry SHED(REMOVE) - T) / 10/ T- � `� \ / / 5 TANKDETAIL-NO SCALE EXIBTI!O F.(ABANDON) / / / N� 6 11 7 \ N O / C PORCH m"o EXISTING SEPTIC TANK(ABANDON PER CODE) ,/ / CONTOUR LINES PER GIS,REFER TO APPLICATION FOR PROPERTY ACREAGE. NAVD88 ELEVATION IS UNKOWN I / - THIS IS NOT A-SURVEY: 170.6 _ site features,topography,elevations and benchmarks are based on assumed datum '*T / — - provided by the owner and county planning records and are Intended only for the review and construction of the proposed septic system design.Hunter Septic Design 9i. recommends that a licensed professional land surveyor always be used to set comets,B / establish lot Ones,determine elevations and topography and I or provide a legal site plan. 75.0 Afee ma be charged for final Inspection and record drawings EH APPROVED • CAswN•DATE v R DN tuTsTB Rhonda Thompson 07/0612026 ak , J 6FT SETBACK FROM DRAINFIELD TO PROPERTY UNES SEPTIC DESIGN °E6IGNER \. MASON LAIERO TOALEFT ON 9ALAMRAE TO 6RE ON THE maw. HUNTER SEADAM HUNTER EH Setbacks PD Boo 182/Olympia,WA98507 380.89D-27781 adam hunlerse flcdesl n.com 3405 sI34 BALL AN Bs: A.) Drainfield/Reserve requires 10'setback from footing/foundations SEPTC SYSTEM DESIGN FOR E B.)Septic tank(s)requires 5'setback from all footing/foundations EAr& /O�1� ' 80 RUSSELL SITE LEGAL C.)No foundation/Perimeter Drains within 30ft,downgradient of 1 LLAKE LIMERICK 1 LOTS7 Drainfield/Reserve area BAL E NLAKE• D-)No Cut Bank(s)(greater than 5ft and over 45 degrees)within G.YL PARCELNUMBER 81TEIPERMITO: PAGE: lops 50ft,down gradient of Drainfield/Reserve area 321275000087 E.)Use approved mitigation from section C1-9 of the department of ecology's"Criteria For Sewage Works-.Design,"when sewer transport lines are within 10ft of water supply lines. '