HomeMy WebLinkAboutCOM2025-00098 Cell Tower Upgrade - COM Inspections - 5/4/2026 MASON COUNTY Department of Community Development
615 W.Alder St.Bldg 8,Shelton,WA 98584
COMMUNITY DEVELOPMENT 360-427-9670 ext.352
Permit Assistance Center,Building,Planning www.MasonCountyWA.gov
INSPECTION CARD AND CERTIFICATE OF OCCUPANCY**
To schedule an inspection call or visit
https://masoncountywa.gov/departments/community_development/building/inspections/index.php
Permit Number COM2025-00098 Date Issued 12/09/2025 Issued By
THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED EQUIPMENT AS INDICA PER
BELOW:
GROUND WORK:
REMOVE 8'CHAIN-LINK FENCE SECTION
Project REMOVE(1)100 GAL PROPANE TANK
REMOVE(1)3'x 3'CONCRETE PAD
INSTALL(1)3'x 12'CONCRETE PAD
INSTALL 48KW DIESEL GENERATOR
INSTALL 200A ATS
RELOCATE(1)ICE BRIDGE POST
Site Address 7623 E STATE ROUTE 3
Applicant Vinh Dinh
Contractor
Contractor Phone
2021 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type
Permit Type CELL TOWER UPGRADE Occupancy
-APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS.
-DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED.
-THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY.
-ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION.
-OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION.
**THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.**
PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET
Public Works Access/Driveway Other
Health Septic Well
Deptartment
Planning Site Inspection
Department
Fire Marshall Fire Apparatus Access Fire Sprinkler
Auto Fire Alarm Hood and Duct
Other Final
Building Building Official: Community Services Designee
Department
Concrete Setbacks -/ c Slab
Footing Perimeter W Point load Footing
Footing Interior Footing Decks/Porches
Foundation Stem Walls Other
Rough-In Groundwork Plumbing Framing
Groundwork Mechanical Plumbing
Groundwork Gas Pipe Mechanical
Gas Piping Shear Wall Nailing
Underfloor
Other
Insulation Slab Ceiling
Floor Vaulted Ceiling
Walls Vapor Barrier
Other
Wallboard Interior Wall Brace Panels Fire Walls
Nailing
Other
Final Building 5= _Z
. 1.
Department of Community Development
MASON COUNTY 615 W.Alder St.Bldg 8,Shelton,WA 98584
COMMUNITY DEVELOPMENT 360-427-9670 ext.352
Permit Assistance Center,Building,Planning www.MasonCountyWA.gov
INSPECTION CARD AND CERTIFICATE OF OCCUPANCY**
Manufactured Setbacks Setup
Home
Concrete Foot/Runners Final
Other
iKrazan
& Associates, Inc. REPORT NO.: 10626064DFR042426MB
Geotechnical Engineering-Environmental Engineering Date Issued: Page 1
Construction Testing and Inspection DAILY FIELD REPORT
INSPECTION DATE: April 24,2026 JURISDICTION: Mason County
PROJECT NO.: 10626064 BLDG PERMIT NO.: Not Provided
PROJECT NAME: SE06054A 7621 E State Route 3 ENGINEER OF RECORD: TEP
CLIENT NAME: Joy Inc CONTRACTOR: Joy Inc
KRZ PM: Mark Peterson WEATHER: Partly Cloudy TEMP.: 60 F°
As dispatched, I arrived onsite at the T-Mobile/American Tower Oakland Bay site located at 7621 E State Route 3 in
Shelton,Washington,for a post-installed anchor inspection related to the proposed generator installation. Upon arrival,
I met with Ethan, representing the contractor/site contact. Ethan stated that the generator installation and associated
anchorage had already been completed prior to my arrival and that the project had been submitted for final inspection
with the county. I was informed that the county required third-party inspection documentation for the installed anchors
before final approval.
The approved plans reviewed onsite identified the project as T-Mobile Proposed Generator Installation,ATC Site Name
Oakland Bay,ATC Site Number 310511,T-Mobile Site Number SE06054A.The construction detail shown on Sheet C-501
calls for 1/2-inch diameter Hilti Kwik Bolt TZ2 anchors,stainless steel 304, 1/2 inch by 5-1/2 inch,with installation into
the existing concrete pad.The plans also note that required reports are to be provided prior to final inspection and that
bolt inspection is to be completed by a third-party agent.
At the time of inspection,the anchors were already installed and tightened. I visually observed the exposed portions of
the installed anchors, nuts,washers, base plates,and general equipment anchorage.The anchor packaging onsite
indicated Hilti KB1 1/2 inch by 5-1/2 inch expansion anchors. Exposed anchor threads and hardware were visible at the
generator support locations observed. Photographs were taken to document the exposed conditions,anchor packaging,
and installed hardware.
Because the anchors were installed prior to my arrival, I did not observe drilling, hole cleaning, embedment placement,
anchor installation,tightening,torqueing,or any other installation procedure required by the manufacturer or approved
plans. My inspection was therefore limited to visual observation of the exposed installed condition only. No verification
of concealed embedment depth, hole preparation, hole diameter, cleaning method, installation torque,or installation
sequence could be made based on the completed condition observed onsite.
Inspector's Statement of Acceptance:
Informational Purposes Only -The referenced work was performed solely for informational purposes and should not be used for
contract or code compliance
Inspector's Name: a.vvt,f3 Reviewed By: Mark
Peterson
Offices Serving the Western United States Page 1 of 1
Bakersfield•Clovis•Corona • Exeter• Lancaster•Lynnwood •Modesto• Pleasanton•Poulsbo•Sacramento•San Luis Obispo•Tacoma
Krazan&Associates• 1230 NW Finn Hill Rd Suite A Poulsbo WA 98370• Phone:(360)598-2126
This report,exclusively prepared by Krazan&Associates for the client,contains provisional observations and test results subject to review.Reproduction is prohibited without written consent. Results are specific to
inspected/tested locations and items.
x- 'w
Mason County
0 Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
COM2025-00098 CELL TOWER UPGRADE
PROJECT DESCRIPTION: THE PROPOSED PROJECT INCLUDES ISSUED: 12/09/2025
MODIFYING GROUND BASED EQUIPMENT AS INDICATED PER
BELOW: EXPIRES: 06/07/2026
GROUND WORK:
• REMOVE 8' CHAIN-LINK FENCE SECTION
• REMOVE (1) 100 GAL PROPANE TANK
• REMOVE (1) 3'X 3'CONCRETE PAD
• INSTALL (1)3'X 12' CONCRETE PAD
INSTALL 48KW DIESEL GENERATOR
INSTALL 200A ATS
• RELOCATE (1) ICE BRIDGE POST
SITE ADDRESS: 7623 E STATE ROUTE 3 SHELTON
PARCEL: 221304300010
APPLICANT: Vinh Dinh OWNER: WEAVER TRAVIS&TAMMY
21806 POPLAR WAY 802 EATONVILLE HWY W
Brier,WA 98036 EATONVILLE,WA 98328
2062955926
VALUATIONS: FEES: Paid Due
Project Valuation (BID, 28000.00 $28,000.00 Technology Surcharge $14.94 $0.00
ESTIMATION..) Building Permit Fee $452.59 $0.00
State Fee-Commercial $25.00 $0.00
Plan Check Fee $294.18 $0.00
Planning Commercial Review $450.00 $0.00
Fee
Total: $28,000.00 Totals : $1,236.71 $0.00
REQUIRED INSPECTIONS
SLAB INSPECTION BLD-Final Inspection
CONDITIONS
Printed by:Genie Mcfarland on:12/09/2025 04:18 PM
Page 1 of 3
QMason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
CELL TOWER UPGRADE COM2025-00098
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the farthest projection of the
structure. Front setbacks are measured from the front lot line or road easement boundary, whichever is closer.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed.The Building
Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit
expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being
taken.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Code 14.28 and 14.17.
Printed by:Genie Mcfartand on:12/09/2025 04:18 PM
Page 2 of 3
, w
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
CELL TOWER UPGRADE COM2025-00098
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* In addition to the inspections required in IBC, Section 110, the owner, the engineer or architect of record acting as the
owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of
work listed under Chapter 17 and as specified by the design professional. The special inspectors duties &responsibilities
shall be as specified in Chapter 17.
Special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton WA 98584
and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall
be submitted prior to the framing and final occupancy inspections.
SLAB CONCRETE
GENERATOR ANCHORS
* Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to
the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of
the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In
addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or 4tjorized Agent: (lLt a'1 ( ) Date: A .9 'cis
Printed by:Genie Mcfarland on:12/09/2025 04:18 PM
Page 3 of 3