BLD2026-00218 Roof Solar - BLD Inspections - 5/5/2026
INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2026-00218 PROJECT ADDRESS 31 E HICKORY CT SHELTON, WA 98584 PARCEL# 320055000034 PROJECT DESCRIPTION 35 MODULES-ROOF MOUNTED PHOTOVOLTAIC INSTALLATION OWNER DAWSON FRANCES K ADDRESS 31 E HICKORY CT PHONE CONTRACTOR TML INTERNATIONAL LLC dba INFINITY ADDRESS 6405 E Mill Plain Blvd PHONE 8009284785 CONTRACTOR LICENSE TMLINIL800RN LENDER INSPECTION INSP DATE j Comments INSPECTION INSP DATE Comments BLD-Final Inspection Lfztf7Ess S-S`z6 D6 ' fi l %' a'/-Z( INSPECTION RESULTS Pagel W _____________________________________MASON COUIS'TY Department of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584 Permit Assistance Center,Budding,Planning (360)427-9670 ext. 352 Application# BLD2026-00218 Application Type ROOF MOUNT SOLAR Owner DAWSON FRANCES K PANEL-RESIDENTIAL Parcel# 320055000034 Site Address 31 E HICKORY CT SHELTON, WA 98584 Inspector Inspection Type Date Status Comments 4-24-26 DEC PROVIDE L&I INSPECTION RESULTS. Drew Carlson BLD-FINAL INSPECTION 04/24/2026 FAIL EMAIL RESULTS AND INCLUDE PERMIT#, NAME ON PERMIT AND ADDRESS. DREWC@MASONCOUNTYWA.GOV PROJECT WILL FINAL WHEN I CONFIRM RECEIPT OF EMAIL Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2026-00218 ROOF MOUNT SOLAR PANEL- RESIDENTIAL PROJECT DESCRIPTION: 35 MODULES-ROOF MOUNTED ISSUED: 03/20/2026 PHOTOVOLTAIC INSTALLATION SITE ADDRESS: 31 E HICKORY CT SHELTON EXPIRES: 09/16/2026 PARCEL: 320055000034 APPLICANT: TML INTERNATIONAL LLC dba INFINITY OWNER: DAWSON FRANCES K SOLAR USA, 31 E HICKORY CT 6405 E Mill Plain Blvd SHELTON,WA 98584 Vancouver,WA 98661 8009284785 GENERAL CONTRACTOR'S LICENSE: TML INTERNATIONAL LLC dba INFINITY SOLAR License: TMLINIL800RN USA, Expires: 01/08/2027 6405 E Mill Plain Blvd Vancouver,WA 98661 8009284785 FEES: Paid Due Technology Surcharge $1.94 $0.00 Solar/PV Fee $665.00 $0.00 State Fee-Residential $6.50 $0.00 Solar/PV Base Fee $30.00 $0.00 Final Inspection $97.00 $0.00 Totals : $800.44 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection CONDITIONS Printed by:Brittany King on:03/24/2026 09:53 AM Page 1 of 3 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2026-00218 " The installation of solar(thermal or photovoltaic)energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 4 lbs per square foot. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-lbs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two-3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers,fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. Printed by:Brittany King on:03/24/2026 09:53 AM Page 2 of 3 lopMason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2026-00218 * The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: ___� � Contractor or Authorized Agent: Date:' 5 'Lk [Lio Printed by:Brittany King on:03/24/2026 09:53 AM Page 3 of 3 PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 35 MODULES-ROOF MOUNTED- 14.350 kW DC, 13.824 kW AC,31 E HICKORY CT, SHELTON,WA 98584 inflnityso.i _ _ - - - RENIY HOMESCLUTKNS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SITE DETAIL: SHEET INDEX: `,°SEMILL A91U VMICOINER WA 98661 DS 07: MOUNTING-DATA SHEET SYSTEM SIZE: 14.350 KW DC UTILITY: MASON COUNTY PUD NO.3 PV 0.0: GENERAL NOTES AND PROJECT DATA PHONE'1-800818-0598 DS 08: RACKING-DATA SHEET 13.824 KW AC MSP: EXISTING 200A MSP WITH 200A MAIN BREAKER PV 1.0: PLOT PLAN DS 09: SPLICE G rswTr sclAR.coM KIT-DATA SHEET MODULE TYPE&AMOUNT: (35)Z14SHINESOLAR ZXM7SH108-410M ROOF MATERIAL: COMPOSITE SHINGLE PV 1,1: SITE PLAN DS 10: GROUNDING-DATA SHEET REVISIONS MODULE DIMENSIONS: (LAN/H)67.8T/44.64/1.8- ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) PV 1.2: ROOF SECTION DS 11: MID CLAMP-DATA SHEET INVERTER: (18)AP SYSTEMS DS3-L(240V) RISK CATEGORY II: 110 MPH IM 1.0: INVERTER MAP DS 12: END CLAMP-DATA SHEET ap10ATr °" NTERCONNECTION METHOD: LINE SIDE TAP S 1.1: MOUNT DETAILS DS 13: CHIKO USA UL LISTING CERTIFICATE AHJ: MASON COUNTY E 1.1: 3-LINE DIAGRAM DS 14: SITE SAFETY MAP E12: NOTES RACKING: CHIKO RACKING SYSTEM FOR COMP ROOF E 1.3: WARNING LABELS ARRAY AREA: 21.04 SOFT x 35=736.4 SOFT DS 01: PV MODULE SPECIFICATION SHEET DS 02: MICROINVERTER SPECIFICATION SHEET DS 03: COMBINER PANEL CERTIFICATION DS 04: AC DISCONNECT UL CERTIFICATION DS 05: JUNCTION BOX UL CERTIFICATION DS 06: WIRING SPECIFICATION PHOTOVOLTAIC NOTES: 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL WITH THE SMACNA'GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK SYSTEMS. UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN N THAT STATE UNTIL THE ELECTRICAL 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) CONSIDERATION OF NP AND PP BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE Prged NYM 8 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC AOlw THREADLESS COMPRESSION TYPE, LATERAL FORCE DETERMINATION. 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDERAANUAL SHALL BE ON THE JOB W 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. Z DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING W ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO NON.PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR UQ WITHSTAND THE WEATHER. DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRESTRESSED CONCRETE C/) 5.JUNCTION BOXJCOMBINER BOX HAVE TO USE COMPRESSION TYPE STRAW RELIEF POSITIONED FOR TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE } Q Q APPROPRIATE WATER RUN OFF. AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR, 'A 0 K Q Z BOXICOMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW N O W_I 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. ~ U z z 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.601,310.8D) 2 SATELLITE VIEW j =O O APPLIED PROTECTIVE COATINGS PRE NOT ACCEPTABLE, 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE W J W 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE DC SIDE OF THE SYSTEM.(NEC 250.97) PUTS SCALE:NTS m= WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF 28,THE GROUNDING ELECTRODE CONDUCTOR RUST BE PROTECTED FROM PHYSICAL DAMAGE IF - Cl) MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WRING SYSTEM.(NEC 690.34) SMALLER THAN N6 COPPER WIRE.(NEC 250.64 B) QQ 10.N AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT Li- FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) UNGROUNDED CIRCUITS MAYBE EXPOSED DURING SERVICE WARNING-ELECTRIC SHOCK HAZARD. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END. THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT 31,WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAYBE ENERGIZED N THE OPEN POSITION, MAYBE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND(NECE 690.35(F)) A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED 911eM N 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED CONDUCTOR OF THE MULT4WIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER GENERAL NOTES FROM ANY PHYSICAL DAMAGE. NEC210.5. 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B). AND PROJECT 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR DATA 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E). IN.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, SMeel DAN COMMISSIONING AND ACCEPTANCE WITH THE CLENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED JUNCTION 8 PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURERS 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BEAT THE OPTION OF THE INSTALLATION INSTRUCTIONS. ANSI B CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 35.SCREWS,NUTS,BOLTS 8 WASHERS THATATTACH EQUIPMENT GROUNDING LUGS SHALL BE 31 E Hickory 't 11"X 17" 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL. a; ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE REDLINED AND UPDATED AS 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE ..� Shelton,WA 98584, SARA N,,,,y„ APPROPRIATE. LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. United States 18.WHENEVER A DISCREPANCY N QUANTITY OF EQUPMENT,ARISES ON THE DRAWINGS OR 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY r V MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN REMOVABLE FASTENERS. THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM 38.REMOVAL OF A DWP-NTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE - REQUIRED BY THE ARCHITECTIENGINEER. BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC 2 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING Shelton 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FINE-RESISTANCE RATING THAN THE BUILDING 3 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE ROOFCOVERING MATERIAL. ' Th\ GENERAL NOTES AND PROJECT DATA 40.ALL ROOF MOUNTED CONDUIT WILLBEAMINIMUMIR'OFFTHEROOFSURFACE. 3 VICINITY MAP .- wu0 SCALE.NTS • PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 35 MODULES-ROOF MOUNTED-14.350 kW DC, 13.824 kW AC,31 E HICKORY CT,SHELT0N,WA 98584 infinity: WPATY"ONE SOWUT10"S PHOTOVOLTAIC SYSTEM SPECIFICATIONS: �ROOFACCESS POINT VA TEMIEL EA 98661 SYSTEM SIZE: 14.350 kW DC ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS PHONE IAW819.0898 THAT REQUIRE THE PLACEMENT OF GROUND LADDERS NVPi"ITr sana.coM 13.824 kW AC ^�� OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND MODULE TYPE&AMOUNT: (35)ZNSHINESOLARZXM7SH108d10M /^ MODULE DIMENSIONS: LOCATED R AT ON IN NO LOCATIONSINTS OF BUILDING THE REVISIONS (UWm)SYST M S � ROOF CONSTRUCTION IN WHERE ACCESS 110)ZNSHINESOLAR °waa'°" m INVERTER: (18)AP SYSTEMS DS3-L[240VI POINT DOES NOT CONFLICT WITH OVERHEAD SLOPE:19° In iIDadpi SlOB TO AHJ: MASON COUNTY ,1 ` AZIM 305• OBSTRUCTIONS SUCH AS TREE OMBS,WIRES OR SIGNS. GOVERNING CODES: A. Q?"c:" EXISTING INTERIOR MAIN SERVICE • 2021 WASHINGTON STATE BUILDING CODE / PANEL TIED TD EXTERIOR UTILITY • 2021 WASHINGTON STATE RESIDENTIAL CODE �o ' L /1� METER#135 845 223 Sgn•Neoms ` • 2021 WASHINGTON STATE MECHANICAL CODE � • 2021 WASHINGTON STATE FIRE CODE k'' \L ✓✓✓"`\ • 2021 UNIFORM WASHINGTON STATE PLUMBING CODE \� 0k . / N \ - FENCE • 2021 WASHINGTON STATE ENERGY CODE \ \ • 2021 WASHINGTON STATE EXISTING BUILDING CODE `V 4QO `°/ N / \ � • 2023 NATIONAL ELECTRICAL CODE \\ Q ' \ � Q°Fgn, P8qWN.•.a [4L,F A00•u 1n ) k \ ))) �� w Zz &co 03 Z U Z Z � Wwaw ROOF ACCESS POINT ROOF#3 ♦` r (04)ZNSHINESOLAR ZXM7SH108-410M SLOPE:19• AZIM.:215 IS"•+N- �?�� qRi �• " PLOT PLAN ROOF#1 snsel SM. (21)ZNSHINESOLAR ZXM7SH108 410M q SLOPE:19• � 1 NXI16" N / AM.:125• �, SA•el NunDs ;/ PV 1.0 NEW PV AC DISCONNECT VISIBLE, LOCKABLE,LABELED DISCONNECT v / WITHIN 10'OF UTILITY METER PLOT PLAN NOTE: "PV SYSTEM SHALL HAVE THE SAME FIRE w i o SCALE 1/16'=I.0 CLASSIFICATION AS THE ROOF ASSEMBLY' •PHOTOVOLTAIC SYSTEM SPECIFICATIONS: I NOTE: NOTE:(SOLAR PV SYSTEM EQUIPPED WITH SYSTEM LEGEND SYSTEM SIZE: 14.350 kW DC I RACKING AND MOUNTING FEET ARE LISTED RAPID SHUTDOWN)NEEDS TO BE LOCATED fJ 13.824 kW AC AND LABELED IN ACCORDANCE WITH UL 270 EXISTING INTERIOR MAW SERVICE TEREL d POINT MODULE TYPE&AMOUNT: (35)ZNSHINESOLARZXM7-SH108410M WITHIN3FTOFACDISCONNECT. MEER.35845223.OFWTERCONNECTKDN'TIEDTOEXTERKK2UTILITY InflnitySOUr MODULE DIMENSIONS: (L/WM)67.8T/44.6411.8- AND IRC 324.3.1. INVERTER: (18)AP SYSTEMS DS3-L[240V} NOTE: ® NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFE4TY E ME 50LUNONS AHJ: MASON COUNTY "PV SYSTEM SHALL HAVE THE SAME FIRE LOCATED WITHIN IS FROM THE UTILITY METER VnrvcOUJEIRLWAA96661 PHOrf.7A0a818-0596 CLASSIFICATION AS THE ROOF ASSEMBLY" INFINITYSC ARCOM VISIBLE,LOCKABLE,LABELED DISCONNECT NEW AC COMBINER PANEL © NEW DEDICATED PV SYSTEM COMBINER PANEL. WITHIN 10'OF UTILITY METER NEWPV AC DISCONNECT GROUPED REVISIONS WITH SERVICE EQUIPMENT(VISIBLE, 35 NEW NEW(18NEAPLYR STEMS DH106410LM MODULES Oø' Oa. Rer WITHNEW(16)•AP SYSTEMS DS311240VI In4iel Design 3nn8 00 NOTE: LOCKABLE,LABELED) INVERTERS. ATTIC RUN-YES EXISTING INTERIOR MAIN SERVICE PANEL ATTIC FAN-NO -t! &POINT OF INTERCONNECTION.TIED TO ®SHUTDOWN-NO �� IXTERIORUTILITVMETER#135845223 =FIRE PATHWAY 5.900006 eon Sed O10 -ROOF OBSTRUCTIONS O` • ATTACHMENT FOISTS f MODULE,ARRAY WEIGHT(LOAD -RAFTER \ CALLS) --- =RACKING SYSTEM fI f Number of Modules 35 i y Module Weight 45.19 LBS —— =ATTIC RUN Pn*d N.n.& t( Total Module(Array)Weight 1581.65 LBS A48ase Number of Attachment point 86 I X =CONDUIT ATTIC RUN JUNCTION BOX W i ; Mounting System Weight 1.5 LBS Z Mounting System Weight 129.00 LBS p • 3T' Total System Weight 1710.65 LBS W ROOF SECTIONS v Weight at Each Attachment Point 18.39 LBS Z >- ____________________________ Module a Area(67. 44.54') 21.04 SgFI ROOF ao1 MODULE-21 N Y w z O SLOPE-19' ~ U Z Z Total Array Area 736.39 SgFt AZIMUTH-125• =O O 0 Distributed Load Per MATERIAL-COMPOSITE SHINGLE w a w vAw.arr rA,.Aw 232 SqR TRUSS SIZE&SPACING-2'X4 @ 24'O.C. Total Roof Area 2131 SgFt RooF461 MODULE-10 ZZ Total Percentage or Roof Covered SLOPE-19' ruAmA..i wR..rA.N•ioo 34.56% AZIMUTH-305' LL 'J• MATERIAL-COMPOSITE SHINGLE BILL OF MATERIALS TRUSS SIZE&SPACING-2'X4'O 24'G.C. NUMBER OF MODULES 35 ZNSHINESOLAR ZXM7-SH108-410M ROOF 493 MODULE-04 _ , SLOPE-19' aMM N.nro _l NUMBER OF INVERTER 18 EA ON BIR STYLE 1-INCH MAZIMUTH-215TERI C• MATERIAL-COMPOSITE SHINGLE EATON BR STYLE 1-INCH LOAD CENTER SITE PLAN +� \ Ay;C COMBINER PANEL 1 816L125RP TRUSSSIZE&sPACING-2'X4'@24'O.C. AC DISCONNECT I 100A FUSIBLE AC DISCONNECT,240V _ -' O NUMBER OF ATTACHMENTS 86 Cs CHIKO ROOF HOOK#167 ANSI B 1pZ,• RAILS 19 CHIKO 518 RAIL 4200MM 11"X 17" RAIL SPLICE 14 SPLICE KIT MID CLAMPS 54 MIDCLAMPS/UFO N END CLAMPS 32 END CLAMPS/STOPPER SLEEVE GROUNDING LUG 16 GROUNDING LUG PV 1.1 CIRCUIT(S) ®CIRCUIT#1-08 MODULES WITH 04 MICROINVERTERS e8 ®CIRCUIT#2-09 MODULES WITH 05 MICROINVERTERS 1 SITE PLAN ®CIRCUIT#3-08 MODULES WITH 04 MICROINVERTERS w1.1 SCALE:U8'=V-W !CIRCUIT#4-10 MODULES WITH 05 MICROINVERTERS ROOF-1 ROOF-2 0 '-11 Infinity solar (N)PV MODULE INFINITY HOME SaUTIMS (N)PV MODULE sd06E ER PUIN PWNE NEft WA 98661 PFpNI 1S0P81&0696 INFINITY SIXAR.COM 3'-7' �nslONS @ 24"O.C. ------------------------- -- 9 3 ------------------------------------------8-5----------------------- ---------9-3"-------------- ROOF SECTION Project Name d Adtran EXTERIOR BEARING WALL EXTERIOR BEARING WALL w U Z w V 2 Q 0 ¢?Z (N)PV MODULE w a w ROOF-3 T- `"rn LL 3'=4" t > SheM Nome -•--- R N s�etsa. ANSI B 11"X 17" --------------9'---------------------- --------------------------------8'-2"------------------------- ------------------------9'------------------------------ SheN Number PV 1.2 ROOF SECTION EXTERIOR BEARING WALL EXTERIOR BEARING WALL E9ROOFSECTION 0 1 13 Inflnityso;aT IFHTY NOME SOLUTIONS SIDS E MLL PIAIN VANCdNER WA 98881 Plglf'.1d84818-0$8 2 14 W S`�" RENSIONS SIR k" �ra 66 3 15 S S.W 4 16 5 17 P1.d Name N 6 18 z w z imaa 7 19 o 0:aZz U o o w w w Lu w 8 20 LL 9 21 9Ns"I Nm INVERTER MAP 10 22 ANSI B N 11"X17" Sheet Numbs 11 23 IM 1.0 12 24 INVERTER MAP ❑DTU/ECU: MBA -GENERAL STRUCTURAL NOTES: THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF PV MODULE 0 FRAMING USING THE CHIKO RACKING SYSTEM NTH CHIKO Infinity solar AL ROOF HOOK#167 CK-FTS-167RT2 ATTACHMENTS.THE SEE(2/S 1,1)FOR MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE c, eFNir Nq.E sa�rioNs DETAILS,AND MUST BE STAGGERED TO ADJACENT FRAMING ENLARGEDVIEW 6185EMLLMN VM C.NER WP 98861 MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. PNDIE:1dW81B-0698 1. THE PROPOSED PV SYSTEM ADDS 2.32 PSF TO THE ROOF / rsarr swR.coN FRAMING SYSTEM. 2. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER NEW PV REVISIONS SYSTEM.3. GROUND SNOW LOAD=15 PSF \ pC MAX.DISTANCE BIW 357O6 60 5. EXPOSURE CATEGORY=B 4. WIND SPEED=110 MPH 524 I YX4 tFZUS MOUNTING POINTS @ 48" 6. RISK CATEGORY=II (E)COMPOSITE SHINGLE ROOF Prq 1 Nam e& ATTACHMENT DETAIL (SIDE VIEW) Addm. CHIKO MID CLAMP/END CLAMP S,., SE'.L NTs Lu z Z SOLAR MODULE o CHIKO 518 RAIL 4200MM L rn SUS304 FLANGE NUT M8 _ x w UOO 2 SUS304 12 BOLT M8*30 `L w w Mx CHIKO AL ROOF HOOK#167 z N CK-FTS-167RT2 LL MOUNT DETAIL NOTE: RACKING AND MOUNTING FEET ARE LISTED I ANSI B AND LABELED IN ACCORDANCE WITH UL 2703 I 2'X4 TRUSS @ 24'DC 11"X 17" AND IRC 324.3.1. I w? NS_N-"b. NOTE:-PER WAC 51-51-03240,PANELS WILL NOT S 1.1 MOUNT HIGHER THAN 18 INCHES ABOVE THE SURFACE OF THE ROOFTOP TO WHICH THEY ARE MOUNTED. (2)-WOOD SCREW,M6.3 x 65. 2 . ATTACHMENT DETAIL ENLARGED VIEW �,� SCALE.NTS NOTE:(SOLAR PV SYSTEM EQUIPPED WITH VISIBLE,LOCKABLE,LABELED DISCONNECT Rooftop conductor ampacities designed in compliance with THIS PANEL IS FED BY MULTIPLE SOURCES RAPID SHUTDOWN)NEEDS TO BE LOCATED WITHIN 10'OF UTILITY METER art.690.8,Tables 310.15(B)(1),310.15(C)(1),310.15(B)(2), (UTILITY AND SOLAR) WITHIN 3FT OF AC DISCONNECT. 310.16,Chapter 9 Table 4,5,&9.Location specific AC OUTPUT CURRENT I 58A I Inflnitysolar NOTE: temperature obtained from ASHRAE 2017 data tables (35)ZNSHINESOLARZXM7SH108-410M ATTIC RUN-YES NOMINAL AC VOLTAGE I 240V I YIIN WNC SHUTDOWN-NO OWER WA M1 (1 B)AP SYSTEMS DS3 L[240V]INVERTERS RECORD LOW TEMP -11'C NOTE:-INTERCONNECTION 120%RULE NOT APPLICABLE. PHD'E 14054140588 rrr4lr saAAcaM BRANCH I-08 MODULES WITH 04 MICRO INVERTERS AMBIENT TEMP(HIGH TEMP 2%) 3O'C LINE-SIDE TAP DOES NOT AFFECT MAIN PANEL. CONDUIT HEIGHT 7/8' REv�loN4 0 198, ROOF TOP TEMP 52'C UTILITY SERVICE.UNDERGROUND Ir98Dl I vme I 60 POINT OF INTERCONNECT,LINE SIDE TAP CONDUCTOR TEMPERATURE RATE 9O'C EXISTING 240V1200A BUS BAR RATING, L = J L J L J L J MAIN SERVICE PANEL,SINGLE PHASE, N N N N MODULE: (35)ZNSHINESOLAR ZXM7-SH108-410M WITH A 200A MAIN BREAKER Sp".nr..iln s.r BRANCH 2-09 MODULES WITH 05 MICRO INVERTERS 1 INVERTER: (18)AP SYSTEMS DS3-L[240V] UTILITY COMPANY-MASON COUNTY PUD NO.3 UTILITY METER#135 845 223 EXISTING AC DISCONNECT WITH IN BI-DIRECTIONAL IS'FROM METER (12) UTILITY METER, L J L J L J L J i (N)125A COMBINER PANEL, (N)BLADE TYPE 1-PHASE,3W, iv N N N N 120V/240V I 240V,3W,1 HASE FUSIBLE AC DISCONNECT --------------------------------------------1 NEMA 3R 100A-2P 120/240VAC "'""4 BRANCH 3-08 MODULES WITH 04 MICRO INVERTERS I (N)JUNCTION BOX Ate.. 600 V,NEMA 4 (VISIBLE,LOCKABLE,LABELED) UL LISTED 208 BOA FUSES 200A(-- z LINE SIDE TAP LD I L7 1 IE1 LOwa USING IPC L = J L _ J L J L — J II 208 rn Q N N N N I L7 LI �1 LDM8 O ¢Z Z -------------------------------------t 2w Li BRANCH 4-10 MODULES VATH 05 MICRO INVERTERS I LI LI I3 /� 1= 0 Z Z N =OO L L7 ' W IJU I r- -----L---i G N ..__ --J _ G L _ J L _ J L _ J L J L _ J I I �- LL ni ni N N N TO EXISTING -=- -----------------------------------I--------- --------- ------J ELECTRODE EXISTING GROUNDING 1 2 /: 3 SYSTEM 4 ELECTRODE SYSTEM I ShdN- 3-LINE WIRE MAX PARALLEL C.C PV CURR. TOTAL CONT.CURR WIRE TEMP CONDUIT WIRE DERATED MAX.CONT. LENGTH VOLTAGE DIAGRAM TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPE\AMP. OCR #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT.MAX DROP(%) sn..l Sz. O5 x 3.20 x N/A = 16.OOA 2O.OOA #1O\THWN\4OA @9O-C 2OA 2 TRU BLE N AIR 1.00 x 1.00 x 4OA 4O.OOA 16.OOA #6 AWG 4O 0.45 ANSI B 11"X17" M.MN-W O5 x 3.20 x N/A = 16.OOA 2O.OOA #1O\THWN\4OA @9O-C 2OA 8 3/4"EMT 1.00 x 0.70 x 4OA 28.OOA 18.OOA #1OAW 0.73 E 1.1 1.48< 2 18 x 3.20 x N/A = 57.6OA 72.OOA #4\THWN\85A @75-C 8OA 2 1"EMT 1.00 x 1.00 x 85A 85.OOA 57.6OA #8 AWG 1O 0.15 18 x 3.20 x N/A = 57.6OA 72.OOA #4 0 THWN 0 85A @75-C 8OA 3 1"EMT 1.00 x 1.00 5 85A 85.OOA 57.6OA - 1O 0.15 SITE NOTES: GROUNDING NOTES: PV MODULE RATING 0 STC 0 1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND MANUFACTURER ZNSHINESOLARZXM7SH108-410M Infinity soar REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH MAX.POWER-POINT CURRENT(IMP) 1310 AMPS 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE. ___ saur__ UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM MAX,POWER-POINTVOLTAGE(VMP) 31.30 VOLTS 64%ELILLKAN VMWMI 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL, NEC TABLE 250.122. OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS larva ease OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS rf""'AR. 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136. ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC NOM.MAX POWER AT STC(PMAX) 410 WATT REVI810N3 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 690.45 AND MICRO INVERTER MANUFACTURERS'INSTRUCTIONS. MAX SYSTEM VOLTAGE 1500V DY"Op DIY ft ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN " Y7n4 DD VOC TEMPERATURE COEFFlgENT -0.29%d'C INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE BUILDING OR STRUCTURE. NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED MICROINVERTERS SPECIFICATION GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION MICROINVERTER MAKE I AP SYSTEMS EQUIPMENT LOCATIONS: REQUIREMENTS. 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT MICRONVERTER MODEL NO. DS3-L 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO MAXIMUM AC OUTPUT 188W OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLES ANOTHER MODULE. MAX INPUT VOLTAGE 60V 310.15(B)(1)AND 310.15(B)(2). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED MAX AC CURRENT I 3.20A 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] MAX OUTPUT VOLTAGE I 240 V ACCORDING TO NEC 690.34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 Propel N°m&-- e INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC AND AHJ. AChe„ APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)AND (2)TO 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS w USAGE WHEN APPROPRIATE. U DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: z STRUCTURAL NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE w v CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A DESIGNATED TERMINALS MARKED LINE SIDE(TYPICALLY THE UPPER TERMINALS). o, SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE p a z z BEYOND EITHER EDGE OF THE ARRAY / SUBARRAY, ACCORDING TO RAI LOCKABLE,AND BE A VISIBLE-BREAK SWITCH F x ui 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID O z z MANUFACTURER'S INSTRUCTIONS. =O O 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS.IF SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY LL w d w ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). REQUIREMENTS. 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9,AND UD 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ 240. APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 5. MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE FUSES IN ACCORDANCE WITH NEC 110.3(B). SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED ACCORDING TO NEC 690.11 AND UL1699B. ISh dN�me AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: I 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12] NOTES 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120%OF BUS BAR RATING[NEC 705.12(B)(3X2)j. [71ANSIB WIRING&CONDUIT NOTES: 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUS BAR, PV REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. FROM THE UTILITY SOURCE OCPD[NEC 705.12(B)(3)(1)j. ShW Noni°" 3. VOLTAGE DROP LIMITED TO 2% 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WI SUITABLE BUSBAR.HOWEVER,THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED WIRING CLIPS. ACCORDING TO NEC 705.12(B((3)(3). 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:PHASE A OR L1-BLACK 5. FEEDER TAP INTERCONNECTION(LOADSIDE)ACCORDING TO NEC 705.12(B)(1) PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.11 WITH SERVICE BLUE,YELLOW,ORANGE",OR OTHER CONVENTION NEUTRAL-WHITE OR GREY ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL BE MARKED ORANGE[NEC 110.15]. FASTENING[NEC 705.12(E)]. AWARNING . . . . 0 ELECTRICAL SHOCK HAZARD • Infinity solar LABEL LOCATION:MAIN SERVICE DISCONNECT,UTILITY METER KNITY(IDLE SOLUTXk5 6405 E MLL PLAN TERMINALS ON THE LINE AND PER CODE:NEC 890.13(B) VANCOUVER WAN651 LOAD SIDES MAY BE ENERGIZED PNDNE 1-8009180088 IN THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED IFNITY5aAROOM LABEL LOCATION:COMBINER PANEL,AC DISCONNECT, WITH RAPID SHUTDOWN REVISIONS POINT OF INTERCONNECTION PER CODE:NEC 705.20)7),NEC 890.13(B) 8888 D.,I 30026 00 TURN RAPID SHUTDOWN WRtI,- ` SWITCH TO THE 'OFF"POSITION TO SHUT DOWN PV SYSTEM AND REDUCE Sq•0..NA SW TURN OFF PHOTOVOLTAIC AC SHOCK HAZARD DISCONNECT PRIOR TO IN THE ARRAY WORKING INSIDE PANEL LABEL LOCATION:COMBINER PANEL(S),MAIN SERVICE DISCONNECT LABEL LOCATION:MAIN SERVICE DISCONNECT PER CODE'.NEC 110.27(0),OSHA 1910.145(5(7) PER CODE:NEC 690.12(D) AWARN ING DUAL POWER SOURCE ''' • • •' W 9KMARNE{&.PMOTOV01,.7IUC SYSTEM.i • '' ' ►LABEL LOCATION MAIN SERVICE DISCONNECT PRODUCTION/NET METER LABEL LOCATION:RSO INITIATION DEVICE.AC DISCONNECT J�CAUTION : PN{ec1 N•Yw8 PER CODE NEC 690 59,705.30(0) PER CODE:NEC W.120X2) Aft—LAWARNING A CAUTION 1 MULTIPLE SOURCES OF POWER w THIS EQUIPMENT FED BY MULTIPLE PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED O SOURCES: LABEL LOCATION'MAIN SERVICE DISCONNECT TOTAL RATING OF ALL OVERCURRENT PER CODE:NEC 705.30(D),NEC 690.59 DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED 35 PV MODULES z } Q Q AMPACfIV OF BUSBAR . •, _ U 0 3?Z LABEL LOCATION:POINT OF INTERCONNECTION,COMBINER PANEL IN. Y W J PER CODE NEC 755.12(B03) LABEL LOCATION'MAIN SERVICE DISCONNECT U 2 z- PER CODE'.NEC 690.15(8)&NEC 590.33)DX2) J =OF=wLUaw 1h x LABEL LOCATION:DC CONDUIT,DC JUNCTION BOX PER CODE:NEC 690.31 1902) • LL LABEL LOCATION AC DISCONNECT LABEL LOCATION.DC CONDUIT,DC JUNCTION BOX PER CODE NEC 690.13(8) PER CODE NEC 690.31)D02) V^/ S_____e — I�WARNING 0 WARNING POWER SOURCE OUTPUT ' C U CONNECTION.DO NOT RELOCATE" �•wr�. -- THISOVERCURRENTD _EVICE.LABEL LOCATION POINT OF INTERCONNECTION W ANSI B PER CODE.NEC 706.12(BX2) 11 X 1 7E ___ . 91..I NuMd LABEL LOCATION.AC DISCONNECT/POINT OF INTERCONNECTION M PER CODE.NEC 690.54 O 4c MAIN SERVICE PANEL AC COMBINER PANEL UTILITY METER AC DISCONNECT -rNSHINr• ILRp ZXM7-SH108 Series Znshinesolar lOBB HALF-CELL 51,ak �� INSHINESOLAR Infinitysolar Monocrystalline PER(PV Module 6105E MILL PLAIN DIMENSIONS OF PV MODULE(mm) VANCOUVER wA 99561 ZXM7-SH108 Series t-V CURVES OF PVMODULE(400W) raNITY5OURCONI 413 REVISIONS 1 R 0.946441 I.. Rn wt..nr.o••w � hilal D93pI 3!7126 00 1 OBB HALF CELL Black Monocrystalline PERC PV Module ' I I ! . siplrilr6wsh 5991 / 390-410W 20.97% 0.55% tee I ; P-V CURVES OF PV MODULE(40OW) POWER RANGE MAXIMUM EFFICIENCY YEARLY DEGRADATION '. 11 j j 12 YEARS PRODUCT WARRANTY Z$25 YEARS OUTPUT GUARANTEE aw.e Front View Back view w Pr 1851 ..w.. C� Cr �6 CE . � .� . . . Addess rt .,5,((6„o,E(a,m„a2,.,, 9„o 1%141]02 W rso;«n :.114.:4941,4.51:Mm W nv ELECTRICAL CHARACTERISTICS 5TL MECHANICAL DATA 55%Ol.OW:u09.ragemwnsroem .. --_---._ ---._... __-.. _.-.. Cl) eo \ SW5A1,1902MWrlea05179 SnMlYra.pemem system Nominal Power Wall Pmaw/W)' 390 395 400 905 .ill SaWr[ells Monu 1EP.C it 01 1 , 12 ' I I z }O)Q< +.�.r u4 Arts ad .:.nldaradm vob:r •^]-���mM�a •II •�� �re� • Mawlmum PowevdN9evmp(v) 30.50 30]0 30.90 31.10 31.30 Cellsakntatbn 10850.1$) Q W a Z Z .:mum Pown c.rreT: Cl) Ma mptA) 12.]9 12.97 12.95 13.03 13.10 eodule dimension 1>i4.1134v34 mm(Wrth 114414! C.)Z Z Open Omu9040 age vo[M 36.03 36.90 31.10 31.30 37.90 WeIght 20.501.009 W W d W KEY FEATURES CO Snort Cir(un Curtent lsc(A) 13.55 13.63 33 70 13.]] 13.94 L1ass 3.24141,Hlgn Transmlision,AR<oalN Tempered:lass 110461 Excellent Celts Efficiency t,e Better Weak Illumination Response NWNI,Em yl%) 9.95 2020 20.40 20.72 20,97 ).-I.boa 1166,3dbde0 lL Wa w output in weak light condition,such as haze, mm�,350mm Will 001118034031 MBB techrlorogy reduce the distance between busDars and More power •-- --• cable: finger grid line which is benefit to power increase, cloudy,end early morning. cao-• Na-c.nlp+gae 9MMN9me h;<ER M=a .•_ PV MODULE ELERRICAL CHARACTERISTICS I NMOi TEMPERATURE RATINGS WORKING CONDITIONS Anti PID Adapt To Harah Outdoor Environment CHARACTERISTICS 29,.0 295x0 zrroo 30!x0 306 4 daRKING slemvdrage SPECIFICATION NMOT XC.2C Issay. SHEET _ Ensured PID resistance through the quality control of cell Resistant to harsh environments such as salt,ammonia, manufacturing process and raw materials, sand,high temperature and high humidity environment. Mu.lmum POwnvoltege vm0P(v) 29.30 27.50 2070 29.90 29.10 TempnatWe[OMrcNmdPmaa .0.3551% operatlrglemperature -40(_•65% Shat size 1-�L /�� Ma.rmum Powe,0,1,8 'm011145 10.29 30.35 30.43 10.47 10.53 Temperaton[ama[M %o1vo[ -0.2951 Mammum xrlez6 s. 250 AN B rY� TIER I 1521 Excellent Quality Managerment System opencb[vnvomgevp[M 34,10 X.50 3470 3440 35.0 Tempxature coe icient4N[ 0.05%/C RaesdeWumum5NKlwdr, upIO S[000a 11"X 17 � Global,Tier 1 bankable brand,with independently certified LY-1V Warranted reliability and stringent quality assurances well c.,vde.ar9nu,n R,x toad,�s 0030343008 Sh6at Huron soon ar[vx cuneT ls[(A) 1g.9s 3103 1100 1u: n.19 advanced automated man ufact urng. beyond certified requirements. '"""" "` ""• - � �_�w. DS 01 PACKAGING CONPIGURATION� 1:v«tr dra+a�aw .„w,...:ar..k e4mxro50930 air» v:iwddWw ..,a w O .er.. ? Improved Aesthetics ----------'-"-''-'-" - ----- -------. nH 14[4/90. 36 Compared to conventional modules,this full blade modules a5N/COnWr,,laeIiq) 936 have a more uniform appearance and superior aesthetics. Founded in 1360.ZN5rfine 5014.:1 a wusdS 64406E-y ruyr:-nuo'n PT rWOule manufamu'aodayh the advanonv production Bale,the[ompary boas M bold,mc55:e d:19, uW 2N.i lntlial Lm.jiraAnfiangsu 0. 0 213251,P. 00, `L,rat:.86 919 6632 023 3 '-Ty E-mail:ndoQnsM ur neso .[om capacity of 6GW.0100803300 has listed Zl l5hine era global 51011 PS module maser.Today Z,,35011 has distributed its sales to 30015 than(0(04141:45 a1Ound the gione mesots,x.r1 Note;spe[Kkatbns in[Wded in thi,daUsheet aresubledttoohenge withoutlone.2N5HINE1eselves M,right or fnallmermeratlod 58559350501-it20221011,:,,:aaen'5X,002202.£ :W2W.Zn5h euepedelundemakmq or Ainalty1 Inasultaburyd specialpurpose orbeing InoWNd ineabaodiWrysunounamgsis aunts unlesssi otherwite speoloa99 dommeledbymanoadwnin[.Tract document ® inflnitilij 4 APsystems Leading the Industry in • aswln NontE saurxxa A L T E N E R G Y POWER Solar Microinverter Technology Moael ,,3 S G53-L DS3 yM405EMRwpAIN Region PIweiv l.00haI°usse Canada "1411nsOlAR.COM Input Data(DC) Recommended PV Module Power(STC)Range 25OWp-480Wp+ 265Wp-57OWp+ 300Wp-66OWp+ REVISIONS . Peak Power Tracking Voltage 28V-45V �°p°' orle Rr Operating Voltage Range 26V-60V Iri•elDoipn 117128 00 • • • • pTfl Maximum input Voltage 6OV Maximum Input Current 16402 18A x 2 20A o2 • Maximum input short circuit current 20A per Input 22 5A per input 25A per input Output Data(AC) Sginduewxhsd Maximum Continuous Output Power 640VA 768VA 880VA Nominal Output Voltage/Range" 240V/211V-264V Nominal Output Current 2.66A 3,24 3.74 Maximum Output Fault Current(ac)And Duration 5.69lApk.26.75rns of duration;3.3O7Arms Nominal Output Frequency/Ranger 60Hz/58.8Hz-61.2Hz(HECO:57Hz-63Hz) Power Factor(Default/Adlustahle) 0.99/0.8 leading...O.8 lagging Maximum Units per 12AWG Branch'z' 6(20A breaker) 5(20A breaker) 4(20A breaker) Maximum Units per lOAWG Branch" 9(30A breaker) 7(30A breaker) 6(30A breaker) PmpctNemea Efficiency paeeaa Peak Efficiency 97.3% LLI CEC Efficiency 97% U Z PRODUCT FEATURES Nominal MPPT Efficiency 99.5% o Night Power Consurnpiion 2nmV✓ N W APsystems 3'd generation of dual-module microlnverters,the DS3 product family Mechanical Data represents the culmination of years of power conversion expertise and Innovation in high-efficiency,high-density power conversion to maximize the peak Operating Ambient Temperature Range"' .4OF to+149-F(-4WC to+65'C) O Q Z Z performance of today's high-capacity PV modules. Storage Temperature Pange -4O`F to+I85"F(-4O"C toe85`C) H O Lu J The DS3 series reaches unprecedented levels of power output.It features 2 input channels,each with independent MPPT, Dimensions(W x H x D) 10.3"x 8.6-x 1.6" 10.3"x 8.6"x 1.7" V Z Z 2mm) (263mm x218mm 2 0 0 and encrypted wireless ZigBee communication.An innovative and compact design makes the product lighter while (263mm x 218mm x 41. § w J d LU maximizinsilicone-encapsulated g power production,and components reduce stress on electronics,facilitate thermal x 42.5mm) _Ed diissipation,and enhance weatherproofing.Reliability is significantly increased thanks to 20%fewer components than Weight 5.71b5(2.7kg) 6.8'.bs(3lkg) en previous generations.A24/7 energy access through apps or web based portal facilitate remote diagnosis and maintenance. DC Connector Type Staubli MC4 PV-ADBP4-S2&ADSP4-S2 The DS3 series is grid-interactive and fully compliant with CA Rule 21 requirements.With an excellent performance and Cooling Natural Convection-No Fans U.. high converstion efficiency,a unique integration with less components,the APsystems DS3 series is a gamechanger for Enclosure Environmental Rating Type 6 residential and commercial solar. Feaiturew Communication(inverter To ECU)'O Encrypted ZigBee shed Name isolation Design High Frequency Transformers,Galvanically Isolated MICROINVERTER WIRING SCHEMATIC Energy Management Energy Management Analysis(EMA)system SPECIFICATION Warranty'° 10 Years Standard.25 Years Optional SHEET Compliance sheet sae Safety and EMC Compliance UL174);CSA C22.2 No.107.1.16;UL1741SA;UL174ISB; IEEE1547;Rule 21;SRD-V2.O;FCC Pact15;ICES-003; ANSI B NEC2014&NEC2017&NEC2020 Section 690.11 DC Arc-Fault 11"X17" circuit Protection;NEC2O14&NEC2O17&NEC2O2O Section 60.12 Rapid Shuttlown of PV systems on Buildings Sheet NumEa rfry W en-ran ca-oeernntl<aGy.»onomina(� „i.enby 1l:tr 'AI R9hts Reserved OLA hr f�acal�iwivuemenn m tlah,w rro nvmew a m,rionwr cev Spec ft tans-b-ro change w(hour MNite pleat eivure youare !1)r - rbOawnde9nde mod�nwbrpwr`eM✓efMarbpeat distpac,rn a the mosrrecent update lourxi f b:v:aAPyt—S— DS 02 steAar.cn enn.omm�'Y. V (4,Recunvnenu rro nron tA+n BO invxnrz nw:m ro one ECU/a ffab!e cwnmunketion. (5)7o De a;,y,Me brfae.eerrenly. hya, micralmarnnrxaclbW monxorcd.a ffm fMA . ne,rruv,,;e.ere.row-wanamr recaawAanle wr k.«F✓sruen;.,vm `—j APsystems ��e Enersly Reirx.7—(UL174p 8r, A nd dentifed with the CSA Fx,>1. ,,.,,. C US I--Mark u, �..-.......,Hell 2024/02/22 Rev2.0 inflnitysoar E��• MFMItY40 P AIN HOME S L 6405EMILL A986 VANCOUVER WA 98667 Powering Business Worldwide pe.eaton.com IPHONTYS R,60598 REVISIONS 0ru DaN Fw Iniid Design 017126 00 BR style 1-inch loadcenter Spnelue.Ah Seel BR816LI25RP UPC:786676001472 Dimensions: •Height:13 IN •Length:3.56 IN 'Width:11 IN Project Nem•6 Awe,Warranties: • 10 year w U Specifications: o •Special Features:Current design in •Type:Main lug b m¢ •Amperage Rating:125A ZZ ¢z z •Box Size:7r 2 w ; U 2 Z •Bus Material:Aluminum x o o •Cover:Cover included w w a w •Enclosure:NEMA 3R Z Co •Enclosure Material:Metallic I •Interrupt Rating:10 kAIC w •Main Circuit Breaker:BR •Number Of Circuits:16 •Number Of Spaces:8 •Number Of Wires:Three-wire C0MBBINERINER PANE CERTIFICATION •Phase:Single-phase •Voltage Rating:120/240V SMWsae •Wire Size:#14-1 AWG Cu/Al ANSI B Supporting documents: 11"X 17" •Eatons Volume 1-Residential and Light St"Number Commercial •Cutler-Hammer Type CH and BR Loadcenters- DS 03 Instructions •Type BR Arc Fault Circuit Breakers and Loadcenters •Eaton Specification Sheet-BR816L125RP iII I E §I - - G G v s - - J s a I a R I on I € aaaaa aaaa - EL aaaaaaa ags LELf ELLS Ei - I - I m s 'su 11 1 � I I I I p I I I I 8 # 888 I I I III I I I I I I I II I l I I III I I I ; I I I j I - 8 B 8 § § > _S S 8 8 9 8 8 8 E f s S 9 5 s T a a z F G 0 _ FRAN MAURITSON RESIDENCE r N $ z w V 31 E HICKORY CT pA V O z SHELTON,WA 98584 m PHONE:-N/A o Q EMAIL:-N/A 8 J infinity soar RSTC Enterprises, Inc. rsr+mNax sauraNs 2214 Heimstead Road ° L A D E C K MI VANCOMRWAMI Eau Claire, WI 54703 rrnm saiAxcoN 715-830-9997 FLASHED PV ROOF-MOUNT ,a COMBINER/ENCLOSURES NWDwipI Outdoor Photovoltaic Enclosures 0799 Series Canposltaviced it Roof System sw.h.•iA sW ETL listed and labeled Report#3171411PRT-002 Revised May,2018 • UL50 Type 3R,1 t Edition Electrical equipment enclosures • CSA C22.2 No.290 Nema Type 3R - • Conforms to UL 1741 Standard PrajAA— ,. 0799 Series Includes: I. w 0799-2 Wire size 2/0-14 z 0799-5 Wire size 14-6 p 0799-D Wire size 14-8 Models available in Grey,Black or Stainless Steel Z }rn Q K Q Z z N O l L H U Z Z J Basic Specifications w a r+�y Material options: ,,m • Powder coated,18 gauge galvanized 90 steel , (1,100 hours salt spray) • Stainless steel fsmosaa Process-Seamless draw(stamped) Flashing-15.25 x 17.25' JUNCTION BOX U Heght-3' CERTIFICATION Cavity-255 Cubic inches shrsae Base Plate: ANSI B " • Fastened to base using toggle fastening system — 11 X17" • 5 roof deck knockouts -- • Knockout sizes:(3).5,(1).75"and(1)1" snM Nb� • 8 35mm slotted din rail DS 05 • Ground Block L Passthrough and combiner kits are available for either I AC or DC applications. 0 Cross-Linked Polyethylene Insulated•PVC Jacketed Inflni solar '; =� I'-�' 1 14-750 MCM•2000 Volts•105°C Dry and 90`C Wet b`FN 40 9665$O84OO65 Descri tion VANCOUVER WA98661 ADC's Solarlink brand Photovoltaic cable has a chemically cross- RIONe 1A0g8160698 linked polyethylene insulation with a sunlight resistant PVC jacket. biNR95O8ARCON Bare Copper Applications REVISIONS Appropriate for use in solar power applicatioins that require s rm o. Rr XLPE Insulation 2,000 volt rating. For use in grounded interconnection and un- In6W Dwgn 39708 00 grounded Photovoltaic power systems. Construction PVC Jacket Conductors:Stranded bare copper conductor per ASTM B-3,B-8. Available in 7 or 19 stranded versions as well as tinned copper. SgletlesaMh Sect Sir'I Insulation: White Chemically Cross-linked polyethylene with colored sunlight resistant PVC jacket. .� .. Colors: Black.Green.White,Red. Print on one side with a • "" contrasting ink. An extruded stripe and other colors are available upon request. - r Industry Listings&Standards 'ADVANCED DIGITAL CABLE INC.XX AWO(UL) PV WIRE 2KV 900 WET OR 105C DRY SUN RES t1L Listed as PV per UL$tanderd 4701 Project Nerve E UV RATED VW-1 OR RHW-2 DIRECT BURIAL RoHS RHW-2 per UL Standard 44 and USE-2 per UL Standard 854 Address E324841• 90-C Wet/105C Dry Rated • Gasoline and Oil Resistant II W ROHS Compliant .1 RUH z Sunlight Resistant LISTED W VW-1 Rated rn Q Q aInsulation Jacket Approximate O 0<Z z Part Number AWG Strand Thickness Thickness No I O.D. Net Weight F Y w_ j (mile) (mils) j ) Ibal1 M' 2 =O O 3142DPV 14 7 60 30 .251 39 = W J d W 3122DPV 12 7 60 30 .270 49 31020PV 10 7 60 30 .29d 66 30820PV a 7 70 30 .344 96 IL. 30620PV 6 7 70 30 .381 130 30420PV 4 7 70 30 .429 188 3032DPV 3 7 70 30 .457 228 3022090 2 7 70 30 .489 277 Stw8Neme 3012DPV 1 19 90 30 .569 358 WIRING 30102DPV 1/0 19 90 30 .602 427 SPECIFICATION 30202DPV 2/0 19 90 30 .646 519 30302DPV 3/0 _. .. 19 .. _ 90 30 .696 633 Shed Sca 304020PV MU 19 90 30 .752 784 ANSI B 302502DPV 250 MCM 37 105 30 .829 934 11•X 17• 303002DPV 300 MCM 37 105 30 .875 1104 303502DPV 350 MCM 37 105 30 931 _1260 EF 304002DPV 400 MCM 37 105 30 .976 1431305002DPV 500 MCM 37 105 30 1.059 1745O06 06002D9V 600 MCM 61 120 30 1.166 2097_.30 5 _02OPV 750 MCM 61 120 30 1.268 2612 The 8brrnation contained an this specdlaahon 0Intended to Os used as a guide in product Selection 508a505984 b05Nd S be reliable. ADC br1111deeseryercorttoensuretnedatasrwwnaoorelsaccu,aleat Nebnreotpu N,ca9on msspednrihonissubkgbettgeanybmewlnputnolks A5V9821 181 PHONE: (800) 343 2579 • FAX: (828) 389 3922 • WWW.ADCABLE.COM 'IC HIKQUSA N�___ �r RACKING MADE SIMPLE INFI 6 HOMESOLA 8005 E MILL RAININ EWER WA 98661 PHON PHONE 1b0681B-0598 INFINITY SOLAR 000 7 RAD MOUNT(Rafter And Decking) REVISIONS Integrated with a L-Foot&Flash with the flexibility to mount to Either the Rafter or Decking.This simple but RADICAL 1n° °°'° "2b °° design is made for asphalt shingle roofs.Installers love the ,., ease and faster install times! SgrW o*ol,Seal Item Product Name CK-FTS-167RT2 RAD Mount Al Roof Hook#167-SILVER CK-FTS-167BRT2 RAD Mount Al Roof Hook#167-BLACK Main Material :AL6005-T5 Rw1act NameO Uplift P :N'Fv(N=3) Addess Wind Velocity :Up to 60 MIS(134 MPH) w Snow Load :1.4 KN/m'/30 lbs/sq.foot z Spacing :Up to 2000mm;6.5 feet;80 Inches w Install Site Type •Asphalt Shingle 4.SSo.imm p 8 z w nS ebmm •a Q of a?Z b1.2mm Standard Packaging:25PC5/CTN LY'z z J =ooh Dimensions :45x27x30/CM w a w 0 0 0 Weight :21KG M_ O le" Z •Optional Holes provided for Rafter&Decking IIl.II- •Flexible moving on orientations Vertical&Horizonal ShedNrm •Water-proof with thermoplastic butyl adhesive I MOUNTING- Material QTY •Faster Install Time DATA SHEET Rad Mount#167 Hook 01 SAW SWe SUS304T2 Bolt M8.30 01 ANSI B SUS304 Flange nut M8 01 11"X17" Wooden Screw M6.365 02 4 Butyl rubber 01 us Intertek CIS 07 For Deck Mount;Add Qty 2 Add'!Screws :0 •-: CHIKQUSA RAC%I"G MADE 5I I^Ft 1 CHIKQinfinity Boor Solar Mounting Solutions WFWIrY/q6E saurme 60 E Ei1 PUN VANCOWER WA 98667 PHONE.uee ied69e PRODUCTLINE KWRY_«A_OOM Item Product Name RES^SIONs My " Cl-FT-R518B1-2100 CHIKO 518 Rail 2100mm i"aro n wrA 60 CK-FT-R518B1-3200 CHIKO 518 Rail 3200mm CK-FT-R51861-4200 CHIKO 518 Rail 4200mm CK-FT-R51881-4350 CHIKO 518 Rail 4350mm s,9Nea.* sw TECHNICAL DATA Main Material AL 6005-T5 Wind Velocity Up to 60 M/S Ix=34466.83 mm' #518 RAIL ly=49849.13 mm° I- 32.4mm H CHIKO 518R aluminum rail is designed for roof mounting system,t could applied on T w all roof mount system.A variety of lengths N can help to reduce unnecessary cut. E CS ( o z > Q¢ O ¢z z 1 �_zz- ~ d =0 0 ADVANTAGES QQ= w W a :8.26mm H • Easy installation • Highclass anodized LL ■ Universal on roof mount system COMPONENT LIST MATERIAL OT( Aluminium Rail 01 soar rae RACKING-WARRANTY WARRANTY DATA SHEET �., - o sasa� ORDERING SPECIFICS ANSI B Standard Packaging BPCS/PKG 11"X 17" Dimensions 2100/3200/4200/4350mm sn�N„ne« Weight 9.6/14.6/19.2/19.85kg �S 08 H 1 KQ infinity Solar Mounting Solutions INFINITY MO61ES UTg15 6106 E MLL PMl VMICOUVER WA 90661 PHONE.I-SMIswa PRODUCTLINE NFINITY SO ARCOM Item Product Name "SI°Ns CK-FT-SKA CHIKO 43 Rail Splice Kit Rem R� IniW).,IV 3/IM W TECHNICAL DATA •. Main Material AL 6005-T5 Wind Load Up to 60 M/S Snow Load 1.4 KM/M2 N 43 RAIL SPLICE KIT CHIKO 43R aluminium rail splice kit is Lu designed for 43R rail connection from Lu back to position. The most simple and handy installation way. T 364mm 0 o<z z 1 Y LLI =ooh ADVANTAGES m=aw z W ■ Easy Installation COMPONENT LIST ■ Highclass anodized MATERIAL QTY Aluminium Rail Splice Kit 01 SUS304¢4.216 04 sh.W Nall. p SPLICE KIT- WARRANTY DATA SHEET sheet sa< ORDERING SPECIFICS ANSI B Standard Packaging 150 PCS/PKG 11"X17" Dimensions 51X38X22CM snee<N9« Weight 30KG DS 09 CHIK �► v Solar Mounting Solutions WFININ HONE 6aunOr 6a5Ea4LPWN VANCIXNER WA 96661 P6496 l70696 DFIIRY ROIAR.DOM TECHNICAL DATA R__ O.togm Dtlo Rw ............._... Iid agR Main Material AL 6005-T5 MD 37916 W Tighten torque 15N.m Safe torque 20N.m cud COMPONENT LIST MATERIAL QTY Grounding Lug 01 SUS304 inner hex hots M8X20 01 SUS304 T4 bolts M8x25 01 Pr.j.tN■R.& Grounding Lug SUS304 hex nut M8 01 Ad*— CHIKO grounding lug is designed for fixing SUS304 spring washer M8 01 U grounding cable going through smoothly SUS304 star washer 01 w betweeen each rails w i- z >-o p jazz ADVANTAGES =00 ■ Easy installation w w a w Mx N ■ High class anodized ■ Tilt-in nut w WARRANTY GROUNDING- �+ DATA SHEET ORDERING SPECIFICS Standard Packaging 140 PCS/BOX 560PCS/CTN ANSI B Dimensions 51X38X22CM 11"X Jr w ,w Weight 5.B/23.2KGS sheet NumEw DS 10 CHIKtnfintysoior 0 Solar Mounting Solutions 6105E MlL PLAN VAMOMR WA 98661 PHONE'.1-MUS 696 MnMTY SOLAR.COM PRODUCT LINE I �� P newswrs Item Product Name CK-FTM-35 CHIKO Fix Mid Clamp 35mm mnro.,m inn o0 CK-FTM-40 CHIKO Fix Mid Clamp 40mm CK-FTM-45 CHIKO Fix Mid Clamp 45mm CK-FTM-50 CHIKO Fix Mid Clamp 50mm PRODUCT LINE Main Material AL 6005-T5 Tighten torque 15N.m Safe torque 20N.m Fix Mid Clamp CHIKO mid clamps is designed base on 0 7R rail to fix module between two module, w 0 30mm to 55mm thickness module are U) available. O=35140/45150 a O C)azz 0 x Q w a w w n 2 z Cn ADVANTAGES COMPONENT LIST ;�. WARRANTY MATERIAL OTY • Easy installation Mid Clamp 01 • High class anodized \' SUS304 Bolt M8 01 Sh.1N— • Tilt-in nut 057 Alu Nut 01 MID CLAMP- DATA SHEET __.. n ;- - ANSI B ORDERING SPECIFICS 11"x17° Star:dard Packaging 100 PCS/BOY, 400PCS/CTN ShMNumba Dimensions 51X38X22CM DS 11 Weight 26.8/27.5/28/28.6KG HIK C Q Infinity sofa; Solar Mounting Solutions r"mNa�9a� 64 EAli PLA14 VANCCIMER WA 911661 PII0.IE.I-0ODb761L596 PRODUCT LINE PFMRY 60LIRC0M Item Product Name REVISONS . o.=a� CK-FTE-35 CHIKO Fix End Clamp 35mm o.h•iYoagn 7nn6 66 CK-FTE-40 CHIKO Fix End Clamp 40mm CK-FTE-45 CHIKO Fix End Clamp 45mm CK-FTE-50 CHIKO Fix End Clamp 50mm sue.."sd PRODUCT LINE Main Material AL 6005-T5 Tighten torque 15N.m Safe torque 20N.m Fix End Clamp P°Add- CHIKO end clamps is designed base on U 7R rail to fix module on the end of rail, Iw 30mm to 55mm thickness module are D=35140/45/50 Lu available, O 0 a z z U Z Z= =O O w a w z � ADVANTAGES COMPONENT LIST WARRANTY MATERIAL OT( • Easy installation End Clamp 01 , • High class anodized SUS304 Bolt M825 01 • Tilt-in nut SUS304 Washer M8 01 END CLAMP- 057 Alu Nut 01 DATA SHEET w.w••r.•�..' sh.l sa. ANSI B ORDERING SPECIFICS 11"X17" Standard Packagi g 100 PCS/BOX 400PCS/CTJ meal Numoe Dimensions 51X38X22CM DS 12 Weight 22/24.5/25.5/26KG 0 Infinity sciur tntertek AUTHORIZATION TO MARK Total �OwNty Assures INFw640 E MILsauNaNs 6105 E MILL PLAIN VANCO.NER WA 98661 PHONE 1b0081&0598 INFINITY SOUR COM This authorizes the apppication of the Certification Marks)shown below to the models described in the Productfs) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing REVISIONS Report.This authorization also applies to multiple isles model(s)identified on the correlation page of the Listing Report oe.coemI Iwi YIaelS. ai7/26 lot This document is the property of Intenek Testing Services and is not transferable.The certification marks)may be applied only at the location of the Party Authorized To Apply Mark. Applicant SHANGHAI CHIKO SOLAR Manufacturer: SHANGHAI CHIK O SOLAR sisatv.ms.d TECHNOLOGY CO..LTD TECHNOLOGY CO.,LTD NO.680 Xing Wen Rd.Jiadintg District, NO.680 Xing Wen Rd.Jiadwg District Address: .iladng Distract Shanghai 201811 Address: Jiading District Shanghai Country. Chita Country: China Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA,Inc_Lake Forest,CA Control Number: 5010190 Authorized by: .' Nana lot I Matthew Snyder,Cettlhcauon Manager m sa W Z US p Intertek 20 Z This document supersedes all previous Authorizations to Mark for the noted Report Number. O ¢?Z r9a.rum ss,n wnsam...rrwir.r"+wtsawrs u 0. ow.V0Wa0aA...rrnerrarrs. _U Z Z J trr e .0 w.� .naaarq�.a rrrr�"rre eer,rweewp rroee.er(arrrmrar.arge�e,rwaaeeye�reae'amr.ox _ 50 r1NY1Ya eerarlee•e'•/•+Barr.ra+er.wiwMr+rrrwar tiriumw ewr�ur+rm lafla* uat emr m.'aar� . 0= �Klerer reaeae rl g11n11r eNerl.•YrrY+rYWR.rrI M}�rrAdYr"Y"Y""v daW.ar "rMrMrtf.i"1r < Lu J a LULU MrYifa'rw4Mrl W +Yr"a*i s4V.e aal.a gs*1 MLlr"ri M`Y"IF�•�r00 ., f _ inlarWt Testvg Services NA Inc 545 East Algcnq in Road.ANngtan Heights,11 80006 LL Telephone 800.345.3851 or 847-439-5667 Fax 312-283-1672 Standard(s): Photovoltaic Hazard Control IANSUUL 37412020 Ed.11 sins Nine Photovoltaic Hazard Control System(PVHCS)using Chiko installation manual deleted by, CHIKO USA UL ChikoUSA Rackin Made Simple Model No:CK-AR Red Based Rooftop System LISTING Product: g P atton Ml Installation Ind CERTIFICATE UL 3741 Version No.:CHIKO.20230601-V.0I-January It.2024(UL 3741 PV Hazard Control Installation Addendum) I sheet s¢e Brand Name: Chiko USA LLC ANSI B Chiko Solar Asphalt Rod 11"X17 Models: Chko Solar Stand-Off I " Chiko Solar Tile Roof I sneer Naroer DS 13 ATM for Report 10536572?LAX-001 Page 1 d t ATM Issued.26-Jan-2024 'Customer Address: Site Specific Safety Map: Customers Name: INFINITY NONE SOLUTM 6105 E MILL PLAIN VANCOUVERWA9666I ' 18-0 Date: (\ "' 6 rsrxn solAR.caM // \ ` REVISIONS Prepared by: Red dashed lines:Roof edges(fall hazards). a, R. Blue arrows:Ladder/scaffold access points. / \ \ / Yellow zones:Material storage areas. \ Sgn....4h S W Lightning bolt icons:Electrical panels/PV arrays. Green star:Emergency assembly point(driveway). ♦ e / \ Add— / U Z W N W H Z > Q Q Nearest Hospital/urgent care: , 0 o Y W Manger contact: •♦ W o LL d Information: LL Signatures: Journeyman Electrician: ISITES QTY Apprentice: """P Roof Lead: IS"L ANSI B Roof Installer: 11'x17' Roof Installer: N . DS 14