HomeMy WebLinkAboutFIR2023-00029 COM2022-00074 - FIR Inspections - 5/5/2026 CERTIFICATE OF OCCUPANCY m, ,ceu,tty,, W L OWNERS NAME: GEDORA BUSINESS COMPANY CLARENCE J WILLIAMS - TRUSTEE OWNER'S ADDRESS: 50 W SENTRY DR SHELTON, WA 98584 TENANT: N/A SITE ADDRESS: 50 W SENTRY DR SHELTON, WA 98584 BUILDING PERMIT NUMBER: COM2022-00074 DESCRIPTION/SCOPE: NEW BUSINESS OFFICE USE OF STRUCTURE: BUSINESS OCCUPANCY: B/S1 OCCUPANT LOAD: 24 TYPE OF CONSTRUCTION: VB SPRINKLER SYSTEM REQUIRED: NO BUILDING OFFICIAL: Joshua Luck TELEPHONE NUMBER: (360) 427-9670 ext. 352 CODE/EDITION: 2018 IBC % This structure has been inspected for compliance with the requirements of this code for occupancy and the use for which the proposed occupancy is classified. CONDITIONS OR STIPULATIONS: All permit conditions and storm water elements must be maintained. INSPECTION CARD a4� Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# FIR2023-00029 PROJECT ADDRESS 101 W Sentry Dr Shelton,WA 98584 PARCEL# 420243100450 PROJECT DESCRIPTION NEW FIRE ALARM SYSTEM OWNER GEDORA BUSINESS COMPANY ADDRESS CLARENCE J WILLIAMS-TRUSTEE PHONE CONTRACTOR ADDRESS PHONE CONTRACTOR LICENSE LENDER INSPECTION INSP DATE Comments INSPECTION INSP DATE J Comments KNOX BOX VERIFICATION Z Printed From Mason County DMS Printed from Mason County DIMS Ip ' 4 ew I MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 COMMUNITY SERVICES SHELTON:360-427-9670,EXT 352 BELFAIR:360-275-4467, EXT 352 ©u,ldhq Plnnn,ng,tnvirunmentol Ilenith,Community Heelth ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bld-inspection.php Permit Number COM2022-00074 Date Issued 12/28/2022 Issued By Project NEW OFFICE BLDG Site Address 50 W SENTRY DR Applicant GEDORA ASSET MANAGEMENT CO Contractor Contractor Phone Primary Code UP2C IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW COMMERCIAL PERMIT Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. •*THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.** PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks •JT . Z-'f-23 Slab Footing Perimeter 2,-( - 1 3 J7Z_ Point load Footing tl Footing Interior Footing Decks/Porches Foundation Stem Walls 11-Z Other Rough-In Groundwork Plumbing -a, - J. Framing g-/ -Z3 — p Groundwork Mechanical Plumbing •Z E c- Groundwork Gas Pipe Mechanical -( -23 be c_ Gas Piping Shear Wall Nailing < Z3 Dt� Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls -2.\ tQ Vapor Barrier Other GEibl,)6 r7 1) D Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building 5Jt �GL Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other pD'�`Kfs lztc Z- -7- JTL 41 - , -c4.( 1-1 1(-(7-Z3 D&C �a+� a+carte & ( 2 (G-Z3 J Tom _ �Oo�\ h5 � \. Sh-wz 4:a( 7 6(-Z3 MASON COUNTY 360-427-9670 Shelton ext.352 .) COMMUNITY SERVICES 360-275-4467 Belfair ext.352 360-482-5269 Elma ext.352 Building,Planning, Environmental Health,Community Health • 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: C 0I 2'G zz- 00 V 1 H ADDRESS/LOCATION: SAO U 7>r ≤ L e NV ,I FINDING I ( 1 OS- --- as 6 ✓e S 5 j2,K4✓e l( 7l Yl . (Q C / / // /� NAY ( V✓ vt-1 il!(6( C$►^,1'i v P /S( j1) 2- i44 rS /yr /oa ( 0 ti -k ,( Q 44 C N 7(4 bff 744 S.Q cteGll��fs ( 'k2 c4 0 - .Iofi ,1 L , Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: 2.1-2S ❑ Please contact our office regarding possible Department: 5G-, structural damage incurred by recent Inspector: J?L "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 360-275-4467 Belfair ext.352 360-482-5269 Elma ext. 352 Building, Planning, Environmental Health,Community Health 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: COI vt 2-oz-_- O o 1 `I ADDRESS/LOCATION: S'D 1,J t -}v r FINDINGS: lvt, L1alei- do.-"i -11o.-s N'lysf 4 l`r •tl.� G7L /k-t c i M t' I s-i _ CG✓✓ c4- f + S,Z , Q -P 1i S GCGti,ev j /lam s eIvct, (r/ vi c t ) a,.t A 7Tlr_t✓al. U7» / s I44 v lv `C 4� L la ✓Y L �,s� L-e�..) 4 4 (+ IQ Wu /c - d/ 6 '+ pH ( e&.4 e d✓!. LvG� aso�t Coves�, wA �e v Items listed above must be corrected to gain compliance. [1 THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to Date: ,2-/(p-1.. Please contact our office regarding possible Department: 15L7 structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: rvt 2-2' 1 '4 ___________ ADDRESS/LOCATIONt5O jJ erA-r\) I) ✓ FINDINGS: e.r n0 3y f cLV r> o `p \ V __ C6_ 4 8 " dee WftSt- cc) V Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed ove are in VIOLATION of Mason County laws and/or ordinances. all for re-inspection when corrections are made before proceeding with any further work. ake corrections, items will be checked on the next inspection. ❑ OK to Date: "� ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: n rr S "natural/man made"disasters.This is NOT a ci) CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY SERVICES 360-482-5269Elmaext.352 Building, Planning,Environmental Health,Community Health 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: CoiZOZ2- 7 ADDRESS/LOCATION: EO e) Set17' b r- g /'644 FINDINGS: © ( Tc < Ve Loeser !Q o I-JA at.t64Ck S k ro + frou Ta oor- rc,k. `20? ory2c}�tl' ( _ es a ?,tee,Es .4 tel ,4 & ;e AU11Ji 9 er s pl &),4 C v/e C ar e k ok ?r-k3r fo Ccvf1L ,5K ail 7 f o? ?3 (O Items listed above must be corrected to gain compliance. [] THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Li Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: 7 il-- Z3 ❑ Please contact our office regarding possible Department: (31.P structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 • k` 360-427-9670 Shelton ext. 352 MASON COUNTY• 360-275-4467 Belfair ext.352 COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building, Planning, Environmental Health,Community Health • 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: Con ,ZOZZ- 7? ADDRESS/LOCATION: • -O i42 Spit& ll r Skl/ H FINDINGS: 1) rov'ie .. m i & Cob e C(Jo 'tS oh fly 1 r(l. per e 4( /S t ro v7ck t)U de i& fock do.�- �rvs o z4 sI e T 2 A>Ut or4 f eriiifl` re$5 Dn tuc&m,1s i6i t/ items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: c -2,3 ❑ Please contact our office regarding possible Department: L� structural damage incurred by recent Inspector: )i2c/ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC 14.12 MASON COUNTY 360-427-9670 Shelton ext.352 (_- .) COMMUNITY SERVICES 360-275-4467 Belfair ext.352 360-482-5269 Elma ext.352 Building, Planning, Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 7 f z©22 OO07Y ADDRESS/LOCATION: £o LJ 7r S//roes FINDINGS: Prow Prowek L a� /e k r o P Low LA'/ I T 44'€S obt E(f' eompiek / 4f ei %1itn/7 €,d/ q) rQ v; A , id i is o vl� Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OKto Date: 1//7 2$ ❑ Please contact our office regarding possible Department: 1-1 structural damage incurred by recent Inspector: "natural/man made" disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov COM2022-00074 NEW COMMERCIAL PERMIT PROJECT DESCRIPTION: NEW OFFICE BLDG ISSUED: 12/28/2022 SITE ADDRESS: 50 W SENTRY DR SHELTON EXPIRES: 06/26/2023 PARCEL: 420243100470 APPLICANT: GEDORA ASSET MANAGEMENT CO OWNER: GEDORA ASSET MANAGEMENT CO 121 W SENTRY CT 121 W SENTRY CT SHELTON, WA 98584 SHELTON, WA98584 1.360.239.1714 VALUATIONS: FEES: Paid Due B VB Business 2788.00 $456,256.20 IFC Plan Check Fee $80.00 $0.00 Covered Deck/Carport 568.00 $12,496.00 Planning Commercial Review $380.00 $0.00 Fee Technology Surcharge $117.66 $0.00 BLD-COM ENERGY REVIEW $80.00 $0.00 Plan Check Fee $2,184.00 $0.00 Building Permit Fee $3,360.00 $0.00 Geo-Tech/Stormwater Review $300.00 $0.00 State Fee-Commercial $25.00 $0.00 Pre-application meeting - Major $240.00 $0.00 EH Plan Review Mechanical Fees $81.00 $0.00 Plumbing Base Fee $25.00 $0.00 Mechanical Base Fee $30.00 $0.00 Plumbing Fees $203.00 $0.00 Total: $468,752.20 Totals : $7,105.66 $0.00 FIXTURES Q.ty Mechanical Fixtures -Oty Plumbing Fixtures 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers 1.0000 Ductless Heat Pump 1.0000 Number of Kitchen Sinks Printed by:Genie Mcfarland on:12/28/2022 11:46 AM Page 1 of 4 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW COMMERCIAL PERMIT COM2022-00074 City Mechanical Fixtures City Plumbing Fixtures 2.0000 For each ventilation fan connected to a single 1.0000 Number of Showers duct 1.0000 URINAL 2.0000 Air Handlers- Miscellaneous 1.0000 Number of Water Heaters and or Vent 2.0000 Number of Hose Bibs 2.0000 Bathroom Sink 2.0000 For each repair or alteration of drainage or vent piping, each fixture 2.0000 Number of Toilets 3.0000 FLOOR DRAIN 7.0000 For each plumbing fixture on one trap or a set of fixtures on one trap (including water, drainage piping and associated backflow protection) REQUIRED INSPECTIONS Setback Inspection Rough- Plumbing Inspection Footing Inspection Mechanical Inspection Foundation Wall-Pre-Pour Inspection Insulation Inspection Shearwall Inspection Connection has been verified by Health or Utilities Framing Inspection BLD-Final Inspection CONDITIONS CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. " All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. Printed by:Genie Mcfarland on:12/28/2022 11:46 AM Page 2 of 4 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW COMMERCIAL PERMIT COM2022-00074 * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * All property lines shall be clearly identified at the time of foundation inspection. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. Printed by:Genie Mcfarland on.12/28/2022 11:46 AM Page 3 of 4 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW COMMERCIAL PERMIT COM2022-00074 * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 10ft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/ Reserve area. * Landscaping must be installed prior to the final of the building. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: �-' Contractor or Authorized gent: Date: /Z "Z''"2Z Printed by:Genie Mcfarland on:12/28/2022 11:46 AM Page 4 of 4 5/6/26,7:14 AM TerraScan TaxSifter-Mason County Washington ♦ . iL . . . Parcels l) y 50 • GEDORA ASSET MANAGEMENT CO •• .• 65 -Services- Professional 50 W SENTRY DR TThiij Li1 SHELTON WA 1f 2 985848045 TR 47 OF NE SW&NW SE PCL 2 OF BLA #99-07 AF#684387 PCL 4 OF BLA #95-07 #602222 PCL 1 BLA #96-10 #621774 S 55/14-16 [ .i.,Iiit-1ii1 ■ ffl iii r . . Land: $0 Land: $0 District: Improvements: $0 Improvements: $0 Current Use/DFL: No Permanent Crop: $0 Permanent Crop: $0 Total $0 Total $0 Total Acres: Ownership GEDORA ASSET MANAGEMENT CO 100% Owner Sales History No Sales History Building Permits COM2022-00074 12/28/2022 A2/N1 NEW OFFICE BLDG 25% EZ 7/31/2023 $468,752.00 SWG2022-00213 5/5/2022 SEPTIC SYSTEM $8,500.00 Historical Valuation Info 2024 GEDORA ASSET MANAGEMENT CO $110,880 $36,000 $0 $146,880 $0 $146,880 2023 GEDORA ASSET MANAGEMENT CO $189,840 $0 $0 $189,840 $0 $189,840 2022 GEDORA ASSET MANAGEMENT CO $140,625 so $0 $140,625 $0 $140,625 Parcel Comments No Comments Available https://property.masoncountywa.gov/TaxSifter/Assessor.aspx?keyld=4328890&parcel Number=42024-31-00470&typeID=1 1/2 5/6/26,7:14 AM TerraScan TaxSifter-Mason County Washington Property Images Click on an image to enlarge it. 1.0.9607.39669 Data current as of:5/5/2026 4:26 PM TX_RollYear_Search:2026 hftps://property.masoncountywa.gov/TaxSifter/Assessor.aspx?keyld=4328890&parceIN umber=42024-31-00470&typelD=1 2/2 PRE-BOUNDARY UNE ADJUSTMENT CONFIGURATION ® coerrs RA aNs�a BLA NO. 2023-00042 S8926'S9'E THOSE PROPERTIES ENCUMBERED BY IrS HIGH VOLTAGE TRANSMISSION LNE RIGHT-OF-FAY. BPA DATE APPROVED: __ GOES NOT ALLOW STRUCTURES TO BE BUILT WITHIN NW NE I II THE RIGNT-OF-WAY•NOR DOES IT Aaow ACCESS TO \ / l•=100' 4019017T TO A 6 TO �FACL11566 THE J!� — I =-OF-WAY NETDS,.Th BE PERMITTED Br SPA DIRECTOR OF COMMUNITY SERVICES DEPARTMENT Jhaitll o• 50' 100• 200• PRgR To INSTALLATION OR CONSTRUCTION. INFORMATION RFGARDR81 1E E PETWMNG PROCESS FOR PROPOSED USES 0 THE 180141-OF-WAY MAY DECLARATION OF BOUNDARY UNE ADJUSTMENT SW SE ^Z BE ADDRESSED-T) BPA REAL PROPERTY FELD SERNCES AT 80O-282-37h3' RECORDED UNDER AUDITOR'S FILE NO.1__12 1 60 OWNER 3 I ^'NOTE ALL WELLS MS AlO PROPOSED WAVE A MN 42074-31-00450 "l0O PROTECTIVE RADIUS'AS`REOUIRED BY HEALTH NOTE BOUNDARY UNE ADJUSTMENT APPROVAL DOES NOT CONVEY TITLE. 3.74 ACRES CODES AND REGULATIONS. ' LEGEND 58926'59 E 407.87 x.584 59'E 373.94' Fa 4) UNE TABLE: 86.91' 50 270.61 27357' 61.80' L1x CODER OF LIVE • = SET 5/8'REBAR&YELLOW BECHrOLT CAP LS NO.28237 - - SECTION 24 O = FOUND PREVIOUSLY SET 5/6'RERAN&YELLOW BECHTOLT JR. I OD POWQ4 '' 3/4'NON PIPE Li 9093441E 30.00' CAP LS NO.28237 AV:12 96 I YIIII $4 I L2 SD4'41'OB� 40.87' Ad O =FOUND 1/2'NON PIPE-SWIFT LS NO.6122 '� / ® ,•� X. ,�,I L3 NBS48'53•E 50.00' 8 7 2 3 i -4 _-� OWNER 2 yAl O -FOUND 5/8'LENFERR REBAR&YELLOW PL STIC CAP LS NO.35977 I \ i = L! 3.10 ALYES 50fi1'07'E 50.02' 9 =CALCULATED POSITION K 1 I LV is 4657'35'E 10.00' (0'2P7) ll+ POB =POINT OF BEGNINNG _�ro ® 0(/Ff�ICf 8 0I L6 S47'OS'T9� 10.00' APN -MASON COUNTY TAI(PARCEL NUMBER ` I L7 S4S02'37T 10.00' NAP - NOT A PLATT — 1 — —_— — — _ W.SENTRY DR. y- _ LA 622.1D31'E 32.06' C (PRIVATE) RS4: = RECORD SURVEY NO. LA 66929 05E 70.47 7 SB9.26'59T 222.49' S8926'59T 115.15' CIO 58926'591 319.53'- - Ct O.L. - OLD LINE SURVEYOR'S NOTES e 50.0'ROAD&UTILITY ct Cl2 63.55' - 255.98'_ o 110 NO0'11121 20D0' EASEMENT© $ © APN 420 JII I .W LII 504'05'271 3320' N.C. = NEW UNE Q-LANDSLIDE 962480 4864 PER RS/5 '� 0.6 $ � S7 ,5 O0J70 r29•O ' S .� .� k/m� 112 SOT26'591 38.57' ' - 50.0'CASCADE _ (SEE S(JVEYOR'S NOTES) ®-50 VELETA6K"BUFFER PEN RSJ5 ` NATURAL CAS E o 71 EASEMENT APR 42024-31-00460 ^ O 724' a•'�' V L'$ ,� J" Lis 4429'21'5915317 AIION = 50' ROAD h UTIU1Y EASEMENT AS � ' INC WELL © � �, ` OMUAL:E 2 r 1 ON \ NILLCR GGE EST CONCAS "' I 114 442718'171 90.00' REFERENCE SURVEY #4., AF 440: —" 641966. \ OF JEHOVAH'S WITNESSESE55 ^; FOUND MONUMENT AS NOTED -ACIEEMENT FOR •EASEMENT. MANWIENANCE AND o \ �LQ (LAMP) - ® HOUSE CURVE TABLE: �'Uh1LTTIES ECONOED UNOOi W 440.2118915. tv ^ SO-SANTARY DRAWFIELD A1D AMENDMENT N0. I TO AGREEMENT FOR EASEMENT. MALL No. � . -�SEPTIC COMPONENT •, RMANTOMNCE ".AtD JFDUOES• AS ABOVE 20D9-00003 P 80NNEViLLE PWNER a OWNER 1 CURVE DELTA RIMS LENGTH DESCRIBED,RECORDED 160Ot Al NO.2185874 "' APN 42024-31-00390 ®-PROPOSED WELL <� : ., I R A00d WW 1l 126 ACRES L7 '5 Cl 29'2840' 100.00' 51.39' (SEE SURVEYOR'S NOTES) \ © NOTE:Poo ••V4 PARCEL V STRUCTURES LOCATED PER IMAGERY ON WEE 440. 5 ON Q71'OF h 02 2518'54' 315.00' 139.18' / ` ' MASON COUNTY CIS. A 96-00006 �" \ SHELTON WATER 'L"$�/ I 03 375420• 85.00 56.23' S8927'O 1• .87' 569.2102'E 538.54' SYSTEM. - SBY27'02'E S8727'02E ��' -�' i - 225.67E 267.15' 40.50. 124.84' 'L 138.10' C4 24'T338' 335.00' 142.63' _ 1_. b C5 21.17'22' 363.54' 735.06' - (sMaRr Pur NO.3o6s:AFN 1956465) u: $ ,�.. GxcuUTm ^/ �C, o SEE APPROVED SEE FOR ADDITIONAL DOSING VARIBLF m m o, n lllJll SWG2022-00520 WIDTH EASEMENT FOR THE BENEFIT OF `s / 1 ,r�, ^I 1/16 C6 11.3909' 739.D9' 150.37 Tv `I c n DATED 10/13/2022 LOTS 1-9 0 '1\ W.BERRY APN 42024-34-90049 L `� I C7 1Z47'07' 765.74' 17097 3 I ^4 ) EASEMFNr .I — — _ O s' C8 20'37 .51''34' 788 283.86' o EGRESS&UTILITIES PER 955) , -\ RIDGE RD. ' - / ) C9 160744' 778.51' 219.15' Q - 4z/g•F he 41'E 4 I I \ G i FOUND 015 2657'58' 125.00' 45.74' O ski Ci 84.39' � j S.1/4 CORNERSECTION OF124 25 C11 OT03'32' 175.00' 2156' qy � //, 1/2'NON PIPE U zsS //////////// ` — / OLV:12/96 c1z ir33'ss' 77s.ao' 3631' a N �• R)1 .0 LOT 9 OF SHORT PLAT NO.3055:Mil 1956465 13 / 013 094634' 120.00' 20.48' — — — —{ c5 C6 EP. c7 - REFERENCE SURVEYS SOT6 J _ AGATE LAND SURVEYING, PLLC \ W.SHELTON MATLOCK RD. 2660 E ACME RD.-P.O.BOx 146 _ _ 7 _ - �� 1) VOLUME I OF SURVEYS.PACE 0.SWIFT 9EI.TUN.M 98584-(360)426-4172 _ MASON COUNTY ROAD NO.90100 2) VOLUME 3 OF SURVEYS.PAGE 138 BY JOHN D.SWFT •i 3i (PUBLIC) 3) VOLUMIE 7 OF SURVEYS.PAGES 84 AND 84A BY ROGER D.LOV TT 9°t°U°n0.w" co'Wm 4) VOLUME 22 OF SURVEYS.PACES 80-81 BY SIDNEY C.BECHTOLT JR. DRAWN BY.. DATE SHEET .00 90 5) VOLUME 3 OF SHORT PLATS PACE 238 BY JEFFREY J.LENHERR w00 EEC .MME 2024 I OF J 4287 ('JO:- CJECICED BY SCAM£ FIE ND AUDITOR'S CERTIFICATE TAJIWDARY UNE ADJUSTMENT 1 SURVEYOR'S CERTIFICATE to FOR SCR F, r-too 4283—BUL09c FIID FOR RENRD TMS OAY OF JU I) 2E0024 1145 MAP CORRECOr REPRESENTS A 9.61(7 MADE 87 ME OR 1AVOER ASOW IAESTMENT5.LLC Ai 1a:a1.PM. N VOLUME OF 9Wt1(Y$AT PAGES Mr ONEciN1V N CONFOFAIANCL IWTH THE REOIJIR£YO4rs aF THE 0(0(094 ASSET URMACOWNI CO. aLwifER SECTION INDEX 9NYEY RECD'DI4G ACT AT TIE REQUEST OF ASCW NV(SIYENTS LLC, AT NNE REQUEST OF 90VEY G BEU1rOLT A. ....' CEDCWA ASSET MANAGEMENT CO.010064 BUSINESS CO) N THE N NOVEMEEtt 2023 NE 1/4 SW 1/4:SE 1/4 SW 1/4:SW 1/4 SW 1/4 NE 1/4 59 1/4 SECTION TONRIORP LpMTY AL0IDP —�•-.L+•�' Q-J) _ G. D_ L/-/i• L SECTION 24.TOWNSNP 20 NORTH. SE 1/4 SW 1/4 �•YJYL �QMM'1/L L� Drw'Yw �1. AAN(•.E 4 WEST.WYUAMERE IERDVN;AUDnWYS FILE NO BY SDNEY TAT F.; LAND SURAfl0R NO..28237 MA50N COUNTY.WASHINGTON SW 1/4 SW 1/4 24 20 NORTHiid 3D- O CQ 5/6/26,7:12 AM TerraScan TaxSifter-Mason County Washington J(' ,\1U11C111UII1 1I' rsc.ao.00.ca Parcel GEDORA BUSINESS COMPANY •• • 63 - Services- Business CLARENCE] WILLIAMS -TRUSTEE �� rr.rm 50 W SENTRY DR SHELTON WA 98584 • PCL 1 OF BLA# 23-42 AF# 2212780 S 55/14-16 Land: $355,450 Land: $355,450 District: 0134 -Tax District 0134 Improvements: $2,606,130 Improvements: $2,606,130 Current Use/DFL: No Permanent Crop: $0 Permanent Crop: $0 Total $2,961,580 Total $2,961,580 Total Acres: 6.63000 Ownership GEDORA BUSINESS COMPANY 100% Title Owner Sales History Ii - .. 09/24/25 2216214 1 24-62979 GEDORA BUSINESS COMPANY $0 12/23/19 2123176 2 19-42917 SENTRY MINI STORAGE LLC GEDORA BUSINESS COMPANY $0 07/26/04 1815895 1 200473217 GEODORA BUSINESS SENTRY MINI STORAGE L.L.C. $0 COMPANY 03/20/98 663688 1 199844257 MICHAEL E FOX GEDOR ASSET MANAGEMENT CO $0 03/20/98 663687 1 199844256 ANITA R FOX MICHAEL E FOX $0 03/20/98 663693 1 199844262 GEDORA ASSET GEDORA BUSINESS COMPANY $0 MANAGEMENT C 04/22/96 625701 1 199636297 CHRS-S KEALY;ANDR-M MICHAEL E&ANITA R FOX $590,004 SPEAR 12/15/95 618958 1 199534882 MICHAEL E &ANITA R FOX CHRIS-SHELLY KEALY;ANDREW-MARCY $20,000 SPEAR 07/12/95 610412 1 199532902 SHELTON MOOSE LOGE MICHAEL E&ANITA R FOX $22,000 #1684 08/24/94 593903 1 199429046 SETSUKO I EVANS(YOUNG) MICHAEL E &ANITA R FOX $7,500 Building Permits BP 2013-00964 12/13/2013 COVERED PORCH: @ 100%A] $518.00 hftps://property.masoncountywa.govlTaxSifter/Assessor.aspx?keyld=4383836&parcelNumber=42024-31-00450&typeID=1 1/2 5/6/26,7:12 AM TerraScan TaxSifter-Mason County Washington Historical Valuation Info irTr 2026 GEDORA BUSINESS COMPANY $355,450 $2,606,130 $0 $2,961,580 $0 $2,961,580 2025 GEDORA BUSINESS COMPANY $296,360 $2,297,010 $0 $2,593,370 $0 $2,593,370 2024 GEDORA BUSINESS COMPANY $202,405 $1,789,835 $0 $1,992,240 $0 $1,992,240 2023 GEDORA BUSINESS COMPANY $202,420 $1,510,360 $0 $1,712,780 $0 $1,712,780 2022 GEDORA BUSINESS COMPANY $149,940 $1,616,915 $0 $1,766,855 $0 $1,766,855 Parcel Comments No Comments Available Property Images No images found. 1.0.9607.39669 Data current as of:5/5/2026 4:26 PM TX RollYear Search:2026 https://property.masoncountywa.govrraxSifter/Assessor.aspx?keyld=4383836&parceINumber=42024-31-00450&typelD=1 2/2 Mason County Mason County - Division of Community Development 615 W. Alder St.8 Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FIR2023.00029 FIRE ALARM PROJECT DESCRIPTION: NEW FIRE ALARM SYSTEM ISSUED: 10/30/2023 SITE ADDRESS: 101 W SENTRY DR SHELTON EXPIRES: 04/27/2024 PARCEL: 420243100450 APPLICANT: GEDORA BUSINESS COMPANY OWNER: GEDORA BUSINESS COMPANY CLARENCE J WILLIAMS-TRUSTEE CLARENCE J WILLIAMS-TRUSTEE SHELTON,WA 98584 SHELTON, WA 98584 VALUATIONS: FEES: Paid Due Project Valuation (BID, 9780.00 $9,780.00 Fire Protection Permit Fee $183.97 $0.00 ESTIMATION..) Technology Surcharge $3.68 $0.00 Fire Protection Plan Check $119.58 $0.00 Total: $9,780.00 Totals : $307.23 $0.00 REQUIRED INSPECTIONS KNOX BOX VERIFICATION CONDITIONS OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. • Fire Marshal Comments Printed by:Annie W�leon on:10/30/2023 10:05 AM Page 1 of 2 Printed %-- rom Mason County DMS Printed from Mason County DMS Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FIRE ALARM FIR2023-00029 I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: \0 ? l3 Primed by.Amis Wilson 0n:1 W30 2023 1005 AM Paps 2 o12 Printed From Mason County DMS Printed from Mason County DMS Mason Co Fire Marshal Approved with Conditions 10/04/2023 12:30:16 CONDITIONS: LE ItC •Detectors shall be located at or within 36"og the ceiling peak. --w.,. ~ : Al the termination of the acceptance test,a print-out from the monitoring .r ...we.w 11.1. company showing receipt of all alarms and trouble signals shall be ...o1�c a provided -Prior to scheduling the acceptance test,a fire department key(Knox)box °" "^"" 0° shall be installed and provided with keys necessary to access the building 4a and fire protection systems RISER DIAGRAM Ylta.•11 .. ....._.._ _.__...,..ten.. N D �i) 'ww.w_ r,111■ � i; ��,W+.O Y. TI ' w'4' 'e ,.tom n t• ..�� r >> . W .►." Y b li h. 4 4 4 m,ro 0. li a+ w Rafsrence Stnlckni pten0 for Sp»iffc I romino Cntnr{a and "i ` r { { Detaaa O i. a U FIT011 FA1.0 Printed From Mason G ounty- C Printed from Mason County DMS Mason County Fire Marshal 615 W. Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 Fire Alarm Certification/Final Test FIR Z3 Location: /D/ :&)f'y Contractor: dG� 6� Sc!<•r.ri Phone#: z4' 3'i'7- ≤ Contact: ,4u4', Test Date: //-/-23 CHECKLIST ` Verify panel is in "Normal"condition and clear of any signals / Kill Power At Electrical panel & verify dedicated circuit, red breaker& lockout V AC Trouble/ No Power displayed? I Activate device(s),verify it activates the alarm and shows correctly on the panel ./ Check the Notification Alarm Circuit(NAC) for activation of devices. Walk building while alarm is activated under battery load. Check for all lights and sounds to be in-sync Silence Alarm V Activate a few other devices in different areas to verify alarm reactivates after being silenced Reset Alarm Does panel still show trouble (due to AC power)? Disconnect Signal Loop Circuit (SLC) to create/verify a trouble for each device on circuit L Reconnect SLC. System should reset& only AC trouble showing Disconnect the communication line&verify communication trouble / Do batteries AMP/HR match plans? 2 74// p ' S'- Z 7A « er. FACP Sign on Door(s) leading to panel location? Device Test Log Notification Device Time Comments Water flow Inspectors test Smoke detector at FACP /Z / Tamper switch 1 Tamper switch 2 ,' Manual pull at /Z4 Manual pull at Manual pull at Heat Detector S3 Heat Detector T Heat Detector Heat Detector Heat Detector Smoke Detector Smoke Detector n , , /a Smoke Detector Smoke Detector Punch List/Comments: D t �t��� iS , i I/'Z)2 , ��f -� Jl9n ) i ', // /I/Ia,< & ,0/1iv/ Ai s tiyh 4A Ccc S z- 4/4I 5.e-, tnr7;17 ishcc rt-4W6 t• i4C, 75' Printed From Mason Test? Yes ✓ No„ Printed from Mason County DMS RECEIVED MASON COUNTY FlR2oa3- 000 a-9 COMMUNITY SERVICES SEP t 2 2023 Bung,Planning,Environmental Healtk Community Health 615 W. Alder Street FIRE AAAD !J fv Mason County Fire Protection System Permit ApplicationIUndThtSystein Incomplete applications will not be accepted Owner: 5- IPhone#. f Mailing Address: /of S�14 �kv C�ty: .,≤ State Zip: Site Address: /''/ ` w I V> y c". City: State:L&Zip:__ T Parcel #: Legal Description: h ' Contractor:sO cht� 6�)a7O 1 r�- Phone#z :- 37 Address: / ? // / I� Z2 City: O )SState:uI<) Zip: 9( s2 Contractor Registration#: SOyt\cCrS 9`3`i8L' ' Expiration Date: J 20 7-y Building Square Footage(existing&proposed): 1 / 2°a / 3"� / 4 g �_ Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Aust✓t Sprinkler: New System: Wet Dry Modification: G M ,j Standpipe: Wet Dry Fire Underground Automatic Fire Alarm: _____ Fire Pump Hood& Duct: \ S° ' Dry Chem: gyp. 337- coi4 Wet Chem: } UL certified Monitoring company: Phone#: //j _ " �G Contractors Bid Price: 9 7 ) '° P rice I Printed from Mason County DMS Plan Submittal Requirements Your plan submittal shall include the following: 1. Plans shall be on standard 24"x 36"paper,drawn to scale with dimensions and north arrow. 2. Site and Floor plan with cross sectional and exterior elevations. 3. Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces, etc. 4. Cut sheets and/or references for all new devices. 5. Location/description of all new and existing devices. 6. Battery calculations. 7. Wiring diagrams per floor or zone overlaid on an accurate floor plan. 8. Electrical riser diagram showing all zones, circuits, devices,and end—of—line resistors. 9. Hydraulic calculations. 10. Copy of Contractors bid. 11. Underground Systems; a) NICET FPE Certification b) Underground Civil drawings c) Bedding detail d) Truss blocking/Mega Lugs detail e) Depth/Material for burial f) Pipe size and Type Fees The permit fee will be assessed based on the submitted contractor bid for the project. A plan review fee will be calculated at 65%of the permit fee. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No chan es will be m e without first obtaining approval from the Mason County Fire Marshal. By; Date• _ ___ Print F A Printed from Mason County DMS Honeywell IntelliKnight 6700 Battery Calculation ®la'v>,GHT Secondary Power Source Requirements 1.Control Panel 6700 Control Panel 1 x 0.165000 = 0.165000 1 x 0.310000 = 0.310000 2.Addressable SLC Devices SK-PHOTO(-T) 1 x 0.000300 = 0.000300 1 x 0.000300 = 0.000300 SK-PHOTO-W(-T) x 0.000200 = x 0.000450 = SK-HEAT(-HT)(-ROR) 10 x 0.000300 = 0.003000 10 x 0.000300 = 0.003000 SK-HEAT-W(HT)(ROR) x 0.000200 = x 0.000450 SK-BEAM x 0.002000 = x 0.002000 = SK-BEAM-T x 0.002000 = x 0.002000 = SK-DUCT x 0.000300 = x 0.000300 = SK-ACCLIMATE x 0.000300 = x 0.000300 = SK-CONTROL x 0.000375 - x 0.000375 SK-MONITOR x 0.000375 = x 0.000375 SK-MINIMON x 0.000375 = x 0.000375 = SK-PULL-SA 2 x 0.000375 = 0 000750 2 x 0.000375 = 0.000750 SK-PULL-DA x 0.000375 = x 0.000375 = SK-MONITOR-2 x 0.000750 = x 0.000750 SK-MON-10 x 0.003500 = x 0.003500 = SK-RELAY-6 x 0.001450 = x 0001450 SK-CONTROL-6 x 0.002260 = x 0.002250 SK-RELAY 1 x 0.000255 = 0000255 1 x 0.000255 = 0.000255 SK-RELAYMON-2 x 0.001300 = x 0.024000 = SK-ZONE x 0.000270 = x 0000270 SK-ZONE 6 x 0.002000 - x 0.002000 = SK-FIRE-CO x 0.000300 = x 0.007200 3.SLC Accessory Bases B200S x 0.000300 - x 0.000300 = B200S-LF x 0.000300 = x 0.000300 - B200SR x 0.000300 = x 0 000300 = B200SR-LF x 0.000300 = x 0.000300 B224RB x 0.000500 = x 0.000500 - RTS151 x 0.000000 = x 0.007500 = RTS151KEY x 0.000000 = x 0.007500 = RA100Z x 0.000000 = x 0010000 = 4.SLC Isolator Devices SK-ISO x 0.000450 = x 0.000450 = ISO-6 x 0.002700 = x 0.102000 = 822481 x 0.000500 f= 0.000500 ' tE RECEIVE . . SEP 1 2 2023 r`4C-. 1111 nlrtnr ra-n �i Printed From Mason County d19e0 8/23J2023 Printed from Mason County DMS ^ti _ � OD � � � � n "rNNNNN � (� nNNcnul nrnOicntn cnv+ m W W W W NNNNN ' ZN N U; N ! T7C7C7C7C NtnR17CX � oo Coco OVA W NNNNT7C7CT Q Nno $ 3T � � zz T � r � 9wocj c°nou`"+ Xrna m 88 $ $ rvrvhnc w d tv m m 3 —tr rC� C� {7KNA) w r NNthN0000x. cq cp c c c> = N O T C x 3 0 g �6 r6 O � C� pp Dx -UDgOO0 =01 N a =p a tT A W N ... t�/ . x (ry �, O O i O0 x x XXXX x x x x x x x x x x x x x x x x x x x x x XXXXXXXX �O OP 00000p O O O O O O 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 p0 O p 0 0 0 0 0 0 aOOOOO 000000 000 NCT vN NLINOOwOW00t OOO0CN0 O8 ! ! ! ! ! !! ! ! ! ! ! ! ! ! ! ! ! ! ! ! oo 0 � � o d II II II it U II I! Il II a 11 if II U it II Ii II II ❑ ❑ II II II II t1 it II II II U if II 11 11 II II V O of O cn of O �► XXXX x XX x x x x x x x x xxxxxxxx x x x x x x x x D OO 0 0 0 0 0 0 O O O O O O O O O O o o o O O O p o p o O OOOOOOOO 0 0 0 0 0 0 „w. 0 O O p O N O O O O O p W tV N -+ -+ p 0 0 O O O 0 O N O 0 OOOOOO W Ct1 V N N N A O O V+ Q�1 N N W A W V ttpppp N O OO O O p p Cn Vf (T C11 O fh Cn OO (7' oOO - OO 0 o 00 11O8M, � g $ � � oOQ O O OOOOOO O 0 0 0 O O O O O a n u II II II II II II II II II II II u n II n II II II II II II II II II II II II II II II II II II II it O W O N Honeywell IntelliKnight 6700 Battery Calculation K\ r Note 1:You are fully responsible for verifying these calculations. x�u;EiT Note 2:Use the dropdowns in the yellow cells to enter values. Calculation in Total Sheet 24 Hours Standby Load Current 0.16931 Amps x J 24 1=1 4.063 AH 5 Minutes Alarm Load Current(Amps) 0.31431 Amps x 0.084 = 0.026 AH Total Current Load 4.090 AH Multiply by the Derating Factor J 1.2 = x 1.20 Total Ampere Hours Required 4.91 AH Recommended Batteries: BAT-1270-7AH Batteries The batteries can be charged by the 6700 Charger. The batteries can be housed in the 6700 Cabinet Circuit#1 current is within the limitations of the circuit. Circuit#2 current is within the limitations of the circuit. 6700 Control Panel: The output current is within the panel's limitations. Printed From Mason County Oft8/23/2023 Printed from Mason County DMS Honeywell O }ll IntelliKnight 6700 Circuit Detail NAC 1 • _ • I x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.000000 NAC 2 0 • . . x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 x 0.000000 = x 0.000000 = x 0000000 x 0.000000 x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.000000 Printed From Mason County CA 8/23/2023 S Printed from Mason County DIMS Honeywell KNIGHT IntelliKnight 6700 EOL Voltage Drop Starting Voltage 20.4 Volts Minimum Voltage @ EOL 16 Volts Voltage Drop Warning% 10.00% Current Actual Percent Draw Wire Type Resistance Length Resistance Voltage @EOL Drop Feet Circuit Name Amps AWG Ohms/1000 ft (One Way) Ohms Volts Percent NAC 1 0.000 #12 Solid 1.93 0 0.00 20.40 0.00% NAC 2 0.000 #12 Solid 1.93 0 0.00 20.40 0.00% Resistance Table Wire Type Resitance AWG Ohms/1000 ft. #10 Solid 1.21 #10 Stranded 1.24 #12 Solid 1.93 #12 Stranded 1.98 #14 Solid 307 #14 Stranded 3.14 #16 Solid 4.89 #16 Stranded 4.99 #18 Solid 7.77 #18 Stranded 7.95 Note:All Resistance values are taken from Table 8 Conductor Properties of the NFPA 70 National Electrical Code.All values are for Direct Current Resistance at 75CC (167-F). Printed From Mason County G 8/23/2023 Printed from Mason County DMS