Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWG2026-00111 - SWG Application / Design - 4/16/2026
MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2026-00111 APPLICANT LOWNEY, BRIAN &CHRISTEL Phone: Address: 6820 76TH ST CT E PUYALLUP,WA 98371 OWNER LOWNEY, BRIAN &CHRISTEL Phone: Address: 6820 76TH ST CT E PUYALLUP,WA 98371 SEPTIC DESIGNER PAULA JOHNSON* Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 SEPTIC INSTALLER JOHN GILLILAND* Phone: 360-898-4388 Address: 1510 E MCREAVY RD UNION, WA 98592 Site Address: 4710 NE NORTH SHORE RD Primary Parcel Number: 222025200008 Permit Description: Table 10 repair 3bd OscarXO2 Permit Submitted Date: 04/16/2026 Permit Issued Date: 04/29/2026 Issued By: Rhonda Thompson Current Permit Fees Paid: $845.00 (additional fees may be required upon installation of system). Permit Expiration Date: 03/26/2027 (based on date of inspection) Permit Conditions: 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 7 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS.. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. 1 S OFFICIAL USE ONLY • • • MASON DATE RECEVED: p g/l(eCe)r� ^ C > AMOUNT RECEIVED:�-,r RECEIVED BY: W Cl) & Human Public Health Services (-Jr.✓� Environmental Health 360-427-9670,ext.400 or 360-275-4467,ext.400 Cl) ^ fI COO 415 N.6th Street-Shelton,WA 98584 S W G C7 SJ )I L ( Q z J Z (I) ON-SITE SEWAGE SYSTEM APPLICATION M n APPLICANT PHONE rn -o r Brian & Christel Lowney (253) 278-8796 W z c MAILING ADDRESS-STREET,CITY,STATE,ZIP CODE 7 wS 6820 76th St Ct E Puyallup WA 98371 M SITE ADDRESS-STREET,CITY.ZIP CODE tD 4710 NE North Shore Rd /%-,.r �o� elfair WA 98528 NAME OF DESIGNER CO PHONE SIN Arrow Septic Designs, Inc (360) 898-2255 a NAME OF INSTALLER PHONE D I N Arrow Excavating (360) 898-4388 PERMIT TYPE(select one) ��## rr�� N> DRINKING INy 0 WATER SOURCE U I O RESIDENTIAL OSS LCOMMUNITY OSS ECOM � SS C LS PRIVATE INDIVIDUAL WELL PRIVATE TWO-PARTY WELL z I N TYPE OF WORK(select one) Q PUBLIC WATER SYSTEM NEW CONSTRUCTION/UPGRADES REPAIR/REPLACEMENT OTHER DETAILS(select all that apply) ❑ TABLE X REPAIR I SUBMITTALS � ❑ SURFACING SEWAGE 19 EXISTING FAILURE QI SHORELINE RIDESIGN FORM(REQUIRED) {SEPTIC DESIGN(REQUIRED) BEDROOMS I LOTSIZE WAS LOT CREATED AFTER 4/12025? O I N DIWAIVER(S)(IF APPLICABLE) 3 BR .47 ac ❑ YES Q NO C) I O DIRECTIONS TO SITE AND SITE CONDITIONS:(ex.locked gate) Take Hwy 3 to Belfair and turn (L) onto Old Belfair Hwy. Turn (L) onto NE WA-300 which I o becomes NE Northshore Rd. House on (R), drainfield on (L). Address '4710' on tan house. o I o I ° SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. I 00 OFFICIAL USE ONLY BELOW THIS LINE UPGRADE!FAILURE SOURCE(for reporting purposes) ❑VOLUNTARY ❑MAINTENANCE/PUMPING ❑BUILDING PERMIT ❑HOME SALE ❑COMPLAINT ❑OTHER: INSPECTOR SOIL LOGS 1'O J 0 - COMMENTS/CONDITIONS ( , a 1W1 O—( 1 5L� 1 H -'f f 4 ro-P/1-t(pe- J �(tiini 3, O .5tf RECORD DRAWING AND INSTALLATION REPORT SOIL CODES: V=VERY G=GRAVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINALAPPROVAL. INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED/ISSUED BY DATE THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE Revised:4/14(2025 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 2 0 2 - 5 2 - 0 0 0 0 8 A design will be reviewed when 3 copies of each of the following are submitted: Completed design form that has been signed and dated. "Scaled layout sketch,including all applicable items on checklist. Scaled plot plan,including all applicable items on checklist. "Cross-section sketch,including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.Maximum paper size: 11 K 1" ( t Designer's Name: Arrow Septic Designs, Inc Permit Number: SWG Applicant's Name: Brian&Christel Lowney Designer's Phone Number: (360)898-2255 6820 76th St Ct E Designer's Address: 171 E Vuecrest Dr Mailing Address: __ Ci State Zi Union, WA 98592 Puyallup, WA 98371 n' p City State Zip Designer's Email paulaj@hctc.com : I3S)El�l P al( )6 `I LEIS a u cccom Treatment Device ❑Glendon ❑Sand Filter 0 Mound O Sand Lined Drainfield O Recirculating Filter ID ATU OSCAR XO2 U Other Treatment Level(check all that apply): ❑A p B 0 C El BLI 0 BI:2 l BL3 0 E UN Drainfield Type ❑Gravity 56 Pressure O Trench O Bed l 'Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of.Bedrooms 3 Schedule/Class Netafim .42 gph Daily Flow:Operating Capacity 270 gpd Length 5'dia-25'coil ft Daily Flow:Design Flow 360 gpd Diameter .66 in Septic Tank Capacity(working) XO2 1,000 2-comp gal Number 6 Receiving Soil Type(1-6) 1 Separation 9" (0.75') ft Receiving Soil Appl.Rate 1.0 gpd/ft2 Orifices Required Primary Area 360 ft2 Total Number of Orifices 50 x 6=300 Designed Primary Area 360 ft2 Diameter emitter in Designed Reserve Area 360 ft2 :Spacing 6 in Trench!Bed Width 10 ft Manifold Trench/Bed Length 36 ft Schedule/Class 40 Elevation Measurements Length 33 ft Original Drainfield Area Slope 0-2 % Diameter 1 in New Slope,If Altered 0-2 % Preferred manifold configuration used? l 'Yes O No Depth of Excavation Up-slope 15 in Transport Pipe from Original Grade Doun-slope 12 in Schedule/Class 40 Designed Vertical Separation 24+ in Length 130 ft Gravel-based Drainfield Required? ❑ Yes 56 No Diameter 1 in Pump Required? 2T Yes O No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 411 Duff,in Elevation Between Pump&Uppermost Orifice -2 ft Dose quantity .89 gal Drainfield Squirt Height/Selected Residual(head) — ft Chamber Capacity(flood) 1,000 2-comp gal. Uppermost Orifice❑Higher C 'Lower than Pump Shutoff Pump controls:Please check those required. Capacity @ Total Pressure Head 6.2 gpm Timer O F(apse Meter •' ❑4vent Counter Calculated Total Pressure Head 2.98 ft If Timer: Pump on 30 sec ,Pump off 3 min Comments APPROVED APR 292026 \e -\ MASON COUNTY ENVIRONMENTAL HEALTH Revised:4/14/2025 RET DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 2 0 2 - 52 -- 0 0 0 0L 8 Permit Number: SWG DESIGN ESI CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch it Test hole locations 66 Drainfield orientation and layout Reference depth from original grade: 1 Soil logs l6 Trench/bed dimensions and g Septic tank Property lines critical distances within layout Rf Drainfield cover box locationsl/V Box ave 69 Existing and proposed wells 0 D- Reference depth from original grade within 100 ft of property Rf Septic tank/pump chamber and restrictive strata: Measurements to cuts,banks,and locations [T Laterals,trench/bed,top and surface water and critical areas G6 Observation port location bottom ❑ Location and orientation of 16 Clean-out location 0 Curtain drain collector curtain drain and all absorption [d Manifold placement 0 Sand augmentation components 66 Orifice placement Other cross-section detail: E9 Location and dimension of 56 Lateral placement with distance 9 Observation ports/clean-outs primary system and reserve area to edge of bed Other Information xi Buildings 1f Audiblelvisual alarm referenced Yes No l6 Direction of slope indicator G6 Scale of drawing shown on scale l ' 0 Design staked out ❑ Waterlines bar 0 11 Recorded Notices attached Roads,easements,driveways, l Elevation benchmark and relative 0 9 Waiver(s)attached parking elevations of system components C6 0 Pump curve attached 56 North arrow and scale drawing 9 O Evaluation of failure shown on scale bar yr, Non-residential justification A }l 0 Rf Waste strength O d Flow The undersigned tia 3'' RvVAL designer must be notifie all 1 stallation Ed Yes 0 No AULA JOY JOHNSON �, Signat �,�.. Date EXPIRES 15I j. The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regulations: h x'11 �I? Environmental Health pecialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped 'Approved"by Mason County Public Health. JJi ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note'. The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Revised:4/14/2025 • 1 � Arrow Septic Designs 171 E.Vuecrest Dr. Union, WA 98592 April 13, 2026 Mason County Department of Health Services 415N 6th St Shelton,WA 98584 RE: Brian&Christel Lowney Property(Parcel#22202-52-00008) Septic Replacement/Upgrade Dear Inspector: 0 Attached is a replacement/ 4e septic design for a property located at 4710 NE North Shore Rd,Belfair,WA 98528. There is an existing home built in 1950,which according to historic assessor records is a 3-bedroom.The house has an existing gravity septic system of the same era,and includes a graywater drain that goes under the highway to a seepage pit on the water side of the road. At service visits in February and March-2026 it was found that the main drainfield was not taking water the way it should. Issues found include collapsed concrete tile pipe, separate repairs,root and soil intrusion. Because of the septic system's age and condition,a full igde is needed. "t7 Ce4T Q.fl - The existing tank is to be decommissioned or removed and the old drainfield is to be abandoned. The seepage pit is also to be decommissioned. There is an existing pipe under the highway that may be utilized by the installer, or a new bore may be needed depending on condition. All house plumbing is to be routed into the proposed new septic tank. An internal sewage ejection pump will be needed for the basement plumbing. The proposed 3-bedroom replacement system will be an OSCAR XO2 and will include a new 1,000-gallon 2- compartment treatment tank,followed by a 1,000-gallon minimum 2-compartment discharge tank. The proposed replacement drainfield is 360 s.f. of OSCAR at-grade drip drainfield, sized using an application rate of 1.0 in a Type 1 soil extremely gravelly coarse sand..The OSCAR mound is to be dug into the ground 12-15" and installed flush with the original grade. This will protect it from foot traffic,freezing and possible erosion from king tides as it is near the existing bulkhead. There will also be a new control panel with a timer, elapse meter and event counter to facilitate future operation and maintenance. This system meets Table X repair standards with the new proposed drainfield being less than 30' to the bulkhead in Type 1 soil,treatment level A and BL1 without disinfection,and 24"+vertical separation. We are also showing a reserve drainfield area meeting these same standards. The property is on an existing 2-party well with the neighbor. Wells are over 50' from the proposed tanks and over 100' from the proposed drainfield. The property owner's contact information is as follows: Brian&Christel Lowney 6820 76th St Ct E Puyallup,WA 371 (253)278-879 If you nee e. rmation,please contact my office at(360) 898-225 P ROVE 0 '� since0 APR 292026 MASON COUNTY ENVIRONMENTAL HEALTH P�ztT7; JOHNSON RET Lyrr �� atment System Designer 1' ' v0 ' 0 is 4S (9® APPROVED APR 2 9 2[26 ll� ±C LSrEL L®Wr%1 EV AA ENTAL HEALTH 2 o vj RET 4-it0 .N >Jox�t 5 R,E 9D °D HELP -L R 52.$ A r TE-5i sOL . w�11 • Y ? -�. o3la(z� l —i2 " GSL J I ' - c r•&Et rED a A�1 3 v Oe WA& :3. n i lc ___i "Ij �-f/' 5100349 d�.�PAULA JOY JOHNSON 7�t�lSl:ti �A� a RES p� /OO'>W- v-0 wS* V 1 Control Panel with Audio-Visual Alarm o -e.& riQs„J ,s or£ Hera - ' - '- O Cleanout 1,000 Gallon Septic/Aeration Tank S2o�!D too ' N D 'S �® 2-Compartment with air diffuser Pt S�t�t�>`iT O1,000 Gallon Clarifier/Pump Tank 2-Compartment g O Headworks rr 1 to° x36` O OSCAR XO2 Mound Drainfeld e �e� i� 61 d +-�•-k tf� �o`?G,�(o° �c�' cL�cowtiwoi5��rNmd or Q I Q • L `,.�,_, 8 C' 0 L ✓ atoms- '�- OSCAR-XO2 at-grade drip design calculationsNt, Friction Loss Calculations: :ae Was F=friction loss through pipe in feet of head t 5,oaJs ,, PAULA JOY JOHNSON 'y� L=length of supply line in feet Q= Flush GPM K=47.8(1"sch 40 PVC pipe) (Table 2) Hydraulic Layout*OS-50 coils* 240 4 4 •1 1.4 7.8 50' 300 5 5 1 1.75 9.75 50' 360 6 3 2 2.1 6.2 50' 450 8 4 2 2.8 9.2 50' 480 8 4 2 2.8 9.2 50' 600 10 5 2 3.5 11.5 50' Coils must be arranged in a single line F=130(6.2/47.8)185 F=2.98 Total Design GPM=Flush GPM=6.2(from chart) Total Head= Friction Loss+ Elevation from Pump Tank to OSCAR Coil Drainfield Total Head=2.98+0=2.98(2.98<50' excess TDH—OK) Factory Timer Settings: 1,440 minutes per day/411 doses per day=3.5 min per dose cycle (incl. on&off) From Factory: 30 seconds On&3 minutes Off APPROVED APR 292026 MASON COUNTY ENVIRONMENTAL HEALTH RET OSCAR at-grade drip drainfield design calculations Basal Area Calculations: �GJ,'tiS H •��� Base Design Criteria: 360 gpd design flow,soil type 1(1.0 gpd/ft2),flat site(0-2% r•�, � -0349 ••N���� Basal area required=daily design flow_soil loading rate ';'U.• PAULA JOY JOHNSON �� 360 gpd-1.0 gpd/ft2=360 sq.ft. Coil length=6 coils @ 5' diameter(6 x 5'=30')with 9" coil spacing 5 x 9" (.75')=3.75'=33.75'—use 34' Minimum shoulder width @ 6" (2 x 6" =1')= 1' Minimum side slopes at 1 : 1 slope @ 6" (2 x 6" =1')= 1' Minimum basal area length=coil length+shoulder widths+side slopes=34'+1'+ 1' =36' Basal area width=required basal area_minimum basal length=360 sq.ft.-36'= 10' Basal area dimensions=36'x 10' (360 s.f.) **Note to Installer** Dig OSCAR Drainfield into the ground 12-15"to make final grade similar to the original grade. This will protect the drainfield from washout during potential king tides on Hood Canal and protect transport lines and manifolds from freezing. Media: OSCAR drainfield:ASTM C-33 sand media: as per Washington Department of Health's Recommended Standards and Guidance for Intermittent Sand Filters. Supplies/Control Panel: • OSCAR XO2 Control Panel: The LF1P-RF-AR or ARA control panel shall be used to operate the timed dosing sequencing of the OSCAR-XO2. Timer settings for the OSCAR-XO2 are short and very frequent(3 minutes off and 30 seconds on). The supply line needs to drain between doses, so the"on time" may need to be increased to compensate for filling the supply line prior to each dose. APPROVE® APR 29 2026 MASON COUNTY ENVIRONMENTAL HEALTH RET Each OSCAR-XO2 unit will include: • LF1P-RF-ARA control panel • LOT-30, 1/2 hp, 120 volt pump • Hi-Blow Aerator, HB-80(80 liter/minute) • Hi-Blow diffusers e OS-50 or OS-100 Coils • PVC fittings and drip tubing adapters • HWN-.7-RF automatic headworks • Solid%inches poly tubing for connections • 2 float switches Headworks:HWN-.7-RF • %inches Arkal disc filter, mesh, 130 micron • %inches Arad flow meter • Three oil filled pressure gauges(0-100 psi) • 5 Netafim normally closed solenoid valves(Model 80) OSCAR Cover Options: There may be a desire to cover the OSCAR with something additional to the specified ASTM C-33 sand. The intent is not to have too much additional cover over the final C-33 sand layer. Placing too much cover will inhibit plant root growth. Because the C-33 sand is sub-surface irrigated,grass and other ground cover will grow rapidly,forming a firm protective cover over the OSCAR.At the end of the first growing season the C-33 sand layer will be as firm as native soil to walk on. Cover Options include: • Landscaping jute mat with grass seed or ground cover plantings • Thin layer of mineral soil low in organic content(<10%organics) • Thin layer of crushed or washed rock for wind erosion protection • Thin layer of bark or wood chips Do Not Cover C-33 Sand drainfield with: • Organic mix(manufactured top soil from compost) • Filter fabric A P P R O V E OSCAR authorized dealer supply kit contact info: APR 2 9 2026 • H.D. Fowler, (Tumwater) (360)459-7300 MASON COUNTY ENVIRONMENTAL HEALTH • Iconix Waterworks, (Tumwater) (360)539-7518 RET • Ferguson Waterworks, (Silverdale) (360) 697-1510 a - • � to 4, I^ I) Z < Z = c J W a � un : - 3 0 .L_ IZ F rW: ':V t i''�z:•�:;z t of i �' '• `7 C HJ IM 1VSV A f R 29 2026 �2.. MA30N COUNTY ENVIRONMENTAL HEALTH RET X02 Tanks Pre-cast Concrete Pre-cast Concrete Septic Tank Discharge Tank arn,taN 2/3 13 x. PLAN VIEW 201 VENTED LID � PV = v 2/3 1/3 — Li U LOATS Y i9 boo ,Y 2.4 1O°27" : ryR"PREFERRE01 5 .:0 CROSS SECTION LOWRIDGE ONSITE TECHNOLOGIES DRAWING ID: XO2 Tanks SCALE: NTS DRAWN BY: DBM CK BY: DAVE LOWE DATE: rv: 02.22.2023 : + S:. :ate:;• `¶ L.J.L::::::::............................:..:_ .< _____ LJfffM Treatment tank Discharge tank Introduction: The OSCAR-XO2 treatment system is comprised of two systems: the XO2(a septic chamber,aeration chamber,clarifier,and pump chamber) and the OSCAR: coils, C-33 sand, reverse flush headworks, and control equipment. Wastewater is collected in the septic chamber where gross solids are separated.The waste stream is aerated in the aeration chambers.Aerated effluent passes though the clarifier then into the pump chamber.The expected waste strength will be 30 mg/I CBOD5 and 5 mg/I TSS. Effluent is dosed through a 120 mesh disc filter to OSCAR coils, installed in ASTM C-33 sand. Effluent discharged from the coils is treated by the sand prior to infiltrating into the receiving soil. Final discharge is expected to reach 2 mg/I CBOD, 1 mg/I TSS,and 36 FC/100 ml of effluent, meeting Treatment Level A.The X02 tanks can only be used with OSCAR coils. APPROVED APR 292026 MASON COUNTY ENVIRONMENTAL HEALTH RET Design: The single family residence packages are designated as: OSXO2-240, OSXO2-300, OSXO2-360, OSXO2-450, OSXO2-480, and OSXO2-600 and have the corresponding design flows of 240, 300, 360, 450, 480, and 600 gallons per day. The OSXO2-240, 300, 360, 450, and 480, are standard packages. Design flows greater than 480 gallons per day are considered custom and will require design assistance from Lowridge Onsite Technologies, Inc. For the standard single family residence OSCAR-XO2 package parts list see the appendix. The XO2 can only be used with OSCAR coils. All tanks must be approved by Washington Department of Health. An OSCAR-XO2 is two technologies combined together as one. The system can be designed in increments of flow up to 3500 gallons per day. The OSCAR has different sizing criteria than the XO2. The XO2 is designed in increments ranging from 500, 750, 1125, 2250, 3,000, to 3,500 gallons per day (see Table 1-2). The OSCAR is designed in increments of 62.5 or 125 gallons per coil per day, depending on coil model (see Tables 2 and 3). Consequently, a design for a 7 bedroom system (840 gpd) would incorporate a 1125 gallon per day XO2 plus 14 OS-50 OSCAR coils (875 gpd). XO2: Treatment Tank: The partition wall between the first and second compartment of the treatment tank must have a 4 inch by-pass hole or the bottom of the tee baffle located between 40% to 60% of the liquid depth. Discharge Tank: The patrician between the first and second compartment of the discharge tank must have a 4 inch by-pass hole located at least 18 inches above the floor of the tank and no more than 27 inches between the bottom of the by-pass hole and floor of the tank. Recommended hight is 18 inches, if possible. Table 1-2 500- d 660-670 1 330-340 1 660-670 330-340 80 Vm RJx75gPd c ✓z a 1,000 # 500 1,000 I 500 120 Vm or more 1125 gpd { 1,500 1 750 ! 1 500 : 750 ! 180 Vm or more 2250 gpd 3.000 1! 500 3 000 1.500 360 Vm or more i 4,000 3,000 4,000 1 2,000 480 Vm or more 4,500 3,000 1 4,500 ; 3,000 560 Vm or more APPROVED APR 29 2026 MASON COUNTY ENVIRONMENTAL HEALTH ti� �� RET Thermoplastic Reinforced Thermoplastic motor bracket and discharge with built-in guide bearing.This 1/2 HP pump has a stainless steel top bearing and motor coupling.These are assembled with our A.Y.McDonald stainless steel motors.Two wire single phase models include pump, motor,and 10'lead. This four inch submersible is supplied with grounded leads meetingthe National Electrical Code(N.E.C.)specifications. The performance curve below will assist you in choosing the pump that meets your needs. A APPROVED MODELSI E-30 GPM APR 292026 MASON COUNTY ENVIRONMENTAL HEALTH E - 30 GPM RET B 300 ; ; r ...1_._....».....«._.._..._.. 200 .1_` ..1- .i I j too 11 HPe4 r -.. i Simplex 0 5 10 15 20 25 I —30 35 40 Duplex 0 10 20 30 40 50 60 70 80 Fourplex 0 20 40 60 80 1130 120 140 160 FLOW GPM Specifications JI LOT 30 1/2 Plastic j 115 j 1 j 10.94 9,53 23 EST.1556 SUBMITTAL INFORMATION - Stainless steel pump shell and pump shaft - Powered by A.Y.McDonald submersible motors 1/2 HP. - Reinforced Thermoplastic diffusers and impellers - 11/4"FNPT Discharge - Thermoplastic intake screen and cable guard NO-LEAD:The weighted average of the wetted surface of this no-lead product contacted by consumable water contains less than one quarter of one percent(0.25%)lead. Lowridge Onsi₹e Technologies,Inc. Toll Free:1-877-476-8823 dave@lowridgetech.com P.O.Box 1179 Fax:1-425-335-3622 oscaronsite.com Lake Stevens,WA 98258 A.Y.McDonald considers the information on this assembly drawing correct when published.Item and option availability,including specifications,are subject to change without notice. Submitted by: 1/2022 Ile tLQ Headworks 'HWN - .7-RF FROM PUMP 0 O[ 14a a° 3!4"Flllor 1 :iii cn O 3/4"avatar n lc r N 6 Yll C.l� N 0 O FROM COOL TO TANK TO COI L Panel Wiring Diagram =Factory Wire Model LF1 P�RF�ARA -'-' =Feld Wire Quote#013023DC3 From Main Power Panel 120VAC,10.60 Hz Main disconnect 1 1 provided by others. GND ...............1 SMC�1 PUMP 1.2 L1 ------ 1Lt 240VAC 10 CB 20A 3/4Hp 1.4 From Main Power Panel 120VAC,10,60 Hz Main disconnect provided by others. 1.5 GND ---------------- 1.6 L1 �l — t/ 1 B 120VAC 10 CB 0A 1/4Hp N .... NZ NB ....e...p............ 1.7 t �..............J 1 , BLOWER 1.8 -'• 2B 120VAC 10 1/4Hp 1.9 J y--•---.-.... ' BLOWER 1.10 ------- 3B 120VAC 10 •-- 1/4Hp 1.11 .t 1.12 GND ---------------1 L1 ----' Lt 1.13 N .......J CONTROLS 1.14 CB 10A -- LOGO BASE LOGO 1.15 L1 N iJ Li SIEMENS 6E01052-1 FBOB-OBA1 1.16 Hiaarm el Timer/ 1.17 Redundant Off 0 1.18 1.19 APPROVED 1.20 APR 292026 =� MASON COUNTY ENVIRONMENTAL HEJ LTH 1.21 Push to Silence i4 ` RET 1.22 HAND PUMPI 1'23 ; SEMICONDUCTOR OFF S1 SMC1 MOTOR CONTROLLER 01 SIEMENS 1.24 TO 3RF2150-1BA22 1.25 EDW-WO-OEM-121 1.26 Rev.1.0®02109/2023 Page 1 of 3 , 2.1 ; ; ¼ HAND 2.2 VALVE V1(S1,S2) RELAY IDEC O2L�, RJ2S-CL-A120 2.3 H AUTO + ¼ HAND 2.4 , VALVE V2(83,S4) ` CR2 RELAY Q3 ; °� IDEC RJ2S-CL-A120 2 5 AUTO HAND VALVE V3(S5) 2.6 RELAY OFF CR3 IDEC O4 I F- AUTO RJ2S-CL-A120 2.7 , 2.8 + 2.9 LOGO EXPANSION LOGO EXPANSION DM8 2.10 L1 N SIEMENS 6ED1055-1 FB00-0BA2 2.11 O1 (O5) ALARM LIGHT 2.12 All Er IDEC ` O2 HW SERIES (Q6) AUDIBLE ALARM 2.13 ; : A FLOYD BELL SP-1081 R'R OLe Al" REMOTE ALARM 2.14 ----- 4 --- Q ----------- 5 (AHW OR EQUIV. 120 VAC ALARM) Ught Atom 2.15 1,5 2+6 TRANSFORMER 2.16 Signal CL2-40-24 120V-24V 7 12 40VA 2.17 FUSECTI -- _ 2A F1 216 20mm CR1 N/C Common SOLENOID VALVE S1 219. 1 -t-------- ---------- 24VAC VALVE PROVIDED BY OTHERS 2.20 2.21 1 WC Common SOLENOID VALVE S2 •--------- ------------� 24VAC VALVE PROVIDED BY OTHERS 2.22 CR2 N/C Common 1 SOLENOID VALVE S3 2.23 1 2 -P-------- ------------i 24VAC VALVE PROVIDED BY OTHERS 2-24 APPROVED 2.25 APR 29 2026 tuc... Common.... 24OVLENJ C OVALVEVE S4 MASON COUNTY ENVIRONMENTAL HEALTH PROVIDED BY OTHERS 226 RET CR3 N/C Common SOLENOID VALVE S5 2.27 11 1114 3 _.__..___.. ........._..� 24VAC VALVE PROVIDED BY OTHERS 2.28 EDW.WD-OEM-121 Rw.1.0©02 3 Page 2 afof3 3.1 3.2 Control Panel Connections 3.3 V2 ei 0000® Pressure __ ... -- -- ....._ 3.5ti ' switch L-- ---o-- --�-- --d- ---� High Level 3.6 Alarm Timerl Redundant Off 3.7 3.8 NP T ° 4................................ I I 3.9 ° ° 7 I � B 1 000 3.10 1A 1 • I ; � I I ; 3.11 =--------------------------------i-------------- ---------------b--------...--------' Discharge 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 APPROVED 3.25 APR 2 9 2026 MASON COUNTY ENVIRONMENTAL HEALTH 3.26 RET 3.27 EDW-WD-OEN-121 D Rev.1.0©02/0912023 5 Page 3 of 3 • a w Septic Do%W OSCAR XO2 Pretreatment INSTALLATION&MAINTENANCE OSCAR At-Grade Drip Distribution Systems X49 Q'J O. PAULA JOY JOHNSON `�� 1 tC�Nti t5r=5_iC�tJi=�a 1. Installers must attend OSCAR XO2 training and be certified by Dave Technologies(www.lowridgetech.com)prior to installing this system. 2. Installer must review OSCAR XO2 installer manual prior to system installation. 3. OSCAR XO2 supply kits are available through LowRidge Technologies approved suppliers only. 4. The Treatment Tank and Discharge Tank must both be 2-compartment, State approved and sized per the OSCAR XO2 manual and the onsite wastewater treatment system designer. 5. OSCAR Sand media must meet or exceed ASTM C-33 standards. 6. Install drainfield level with contour of the ground. 7. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 8. Tanks must have risers to the surface as required by Mason County to ensure easy access for future operation and maintenance. 9. Headworks must be in boxes accessible from the surface for future operation and maintenance. 10. Ensure any trees and shrubs are removed,grass is cut short and then scarify surface of ground in drainfield area to prep for drainfield. 11. Ensure 6"minimum cover sand media over the drip irrigation tubing. 12. Install audio/visual high-water level alarm. 13. Flow inducer tube or block are not required for the pump,it can sit on bottom of tank. 14. Install return line from headworks back into the tee outside the inlet of the treatment tank. 15. Waterlines must be a minimum of 10'to any tank or drainfield(a reduction to 5' may be.obtained with a State waiver on lots that meet minimum lot size).Encase all water lines within 10' of septic transport lines and under any driveway/parking areas. 16. Divert all storm water runoff and house downspouts away from on-site sewage system. 17. No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 18. Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 19. All materials and workmanship must meet County and State regulations. 20. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 21. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 22. The tanks are to be protected from vehicle traffic or traffic-rated tanks may be used. 23. The drainfield is to be protected from all vehicle traffic or other damaging factors that could compact or disturb the soils. 24. The preferable cover planting for subsurface drip is turf or grass, or non-invasive groundcover plants. It is recommended to install an optional jute mat upon completion of the drainfield to prevent erosion and then seed with grass immediately. Other options include a thin layer of mineral soil low in organic content(<10% organics)and grass,a thin layer of crushed or washed rock for wind erosion protection,or a thin layer of bark or wood chips. 25. Do not cover the drainfield with organic mix(manufactured topsoil from compost)or filter fabric. 26. The homeowner should ensure no vehicle traffic,roto-tilling or digging in the area of the drip field to prevent damage to the drip tubing. Also, invasive plant species should not be allowed. 27. Home/property owner is responsible for all property lines, corners, surveys,encroachments,etc. 28. Owner Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation&Maintenance. APPROVED APR 29 2026 MASON COUNTY ENVIRONMENTAL HEALTH RET