Loading...
HomeMy WebLinkAboutSWG2026-00118 TANK ONLY - SWG Application / Design - 4/22/2026 MASON COUNTY 415 N 6TH STREET,SHELTON, ,WA 98584 • SHELTON:360-427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2026-00118 OWNER 1600 STAR LAKE LLC Phone: Address: 8035 GRAYSTONE WAY NW SILVERDALE,WA 98383 APPLICANT Graves,Wes Phone: 3604276110 Address: 2272 E Brockdale RD, Shelton, WA 98584 SEPTIC INSTALLER WES GRAVES* Phone: 360-490-9428 Address: PO BOX 1460 SHELTON, WA 98584 Site Address: 124 W BLAKELY DR Primary Parcel Number: 519085000099 Permit Description: Replace septic tank Permit Submitted Date: 04/22/2026 Permit Issued Date: 04/29/2026 Issued By: Rhonda Thompson Current Permit Fees Paid: $275.00 (additional fees may be required upon installation of system). Permit Expiration Date: 04/23/2027 (based on date of inspection) Type of Work OSS Repair Components being Replaced: Septic Tank Only Surfacing Sewage? No Existing Failure? Yes Shoreline? No Horizontal Setbacks Met? Yes Number of Bedrooms: 2 Drinking Water Source: Public Water System Additional Details: IM-1060 Permit Conditions: 2 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 5 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 4 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. I Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. 9Db- cO"oa0q q Qs cad - c` o RECORD DRAWING (continued) APR 28 2026 By I / / \ lk 1 ( i \ __ __ APPROVED APR 292026 I MASON COUNTY ENVIRONMENTAL HEALTH RET HORIZONTAL STRUCTURAL REINFORCING RIBS GAS (TOP)/ LIQUID (BOTTOM) TOP. (FULL CIRCUMFERENCE) PASS-THRU SLOT INSIDE TANK LIFTING HOLES (4 TYPICAL) THREADED m II ACCESS _ -OPENING ~ 24" I.D. DIA. (2 TYPICAL) O O 4.25"TYP. >_ 29 1/2" TYP. F- LENGTH = 133" WIDTH = 62" 8.66" çfl U) 11 H -. } c9 TANK SPECIFICATIONS -w DESIGN CAPACITY I TOTAL CAPACITY WEIGHT GALLONS I LITERS GALLONS I LITERS POUNDS 1060 4012 1337 5060 520J - ______________ ____ SID E IWG SCALE: 1:1 IROTH GLOBAL PLASTIC LOT SCALE: 1:2 ROTH M u I t!Ta n K® ® One General Motors Drip HEFT#: C 1 060 GALLON / MODEL RMT- 1060 Syracuse .Y.132 e8665 Call Toll Free 866.943.725 I nF I www.fralo.ni 74„ ELEVATION L. INLET PORT OUTLET PORT I I to II H w LENGTH = 133" THREADED ACCESS THREADED ACCESS INLET PORT OPENING OPENING OUTLET PORT 24" I.D. DIA. 24" I.D. DIA. 2-iINV IN. o -... - -..SZ...-...- -...-...-..._...-... - .-... INV OUT tl t = 40" LIQUID LEVEL = ® (SEE LOCAL REGS.) m n _ _ OPTIONAL N ® O PARTITION WALL SEE LOCAL REGS. FOR OPENING REQUIREMENT --t 2/3 TANK LENGTH I. 1/3 TANK LENGTH HORIZONTAL STRUCTURAL REINFORCING-' ' EINFORCING SECTION 4011 LIQUID LEVEL ® RIBS (FULL CIRCUMFERENCE) IWG SCALE: 1:1 I ROTH GLOBAL PLASTIC ROTH Multi Ta n K® One General Motors Drip LOT SCALE: 1:2 Syracuse N.Y.132C HEFT#: 1 060 GALLON / MODEL RMT- 1 060 Call Toll Free 866.943.725 'J (1FI www.fraln.ni HORIZONTAL STRUCTURAL REINFORCING RIBS ISOMETRIC (FULL CIRCUMFERENCE) GAS (TOP)/ LIQUID (BOTTOM) MULTI POR PASS-THRU SLOT INSIDE TANK OUTLETS (3 TYPICAL) THREADED ACCESS OPENING 24" I.D. DIA. (2 TYPICAL) LIFTING o HOLES o (4 TYPICAL) I : o MULTI PORT C INLETS z C (3 TYPICAL) rn if- a o WARNING TANK NOTES 1. Access at or above grade level must be secured against unauthorized access. 2. Tank is not rated for vehicular traffic loading. 3. All resin used is compliant with ASTM D 1248 as required by CSA B66 and IAPMO / ANSI Z1 000-2007. 4. Tank material of construction is HMW-HDPE. 5. Primary dimensions are in inches 6. Minimum tank wall thickness is 1/4". 7. Labeling will include: manufacturer name, liquid capacity, date, maximum burial depth, and model number. 8. Riser cover contains the following: 6" x 3" warning: "Danger - Do not enter - Poison Gas" - written in English, French & Spanish. 9. Maximum burial depth from manufacturer is 36" unless specifically instructed otherwise by the factory. 10. Models RMT-750, RMT-1060, RMT-1250 and RMT-1500 are all certified to CSA and IAPMO standards. NOTES 11. Models RMT-500, RMT-900 and RMT-1 000E are compliant with CSA and IAPMO standards. )WG SCALE: 1:1 . ROTH GLOBAL PLASTIC ROTH Mu1tITanK® One General Motors Drib LOT SCALE: 1:2 Syracuse N.Y.132C HEFT#: 1 060 GALLON / MODEL RMT- ■ 060 Ca11To11FreeA66.943.725 (1F VN 10 Gu.nenuYOY}�N. BLtlYlOC www.fralo.ni