HomeMy WebLinkAboutSWG2026-00086 TANK ONLY - SWG Application / Design - 3/26/2026 MASON COUNTY 415 N 6TH STREET,SHELTON, , 98584
• SHELTON:360-427-9670,EXT 400
BELFAIR:360-275-4467,EXT 400
Public Health & Human Services ELMA:360-482-5269,EXT 400
FAX:360-427-7787
On-Site Sewage System Tank Only Permit: SWG2026-00086
APPLICANT Hubbell, Laura&Hercules Phone: 3607799609
Address: PO Box 752 Keyport, WA 98345
OWNER PORT OF SHELTON Phone: (360)426-1151
Address: 21 W SANDERSON WAY SHELTON, WA 98584
SEPTIC INSTALLER LAURA HUBBELL* Phone: 360-779-9609
Address: PO BOX 752 KEYPORT, WA 98345
Site Address: 130 W Corporate Rd
Primary Parcel Number: 420020062000
Repair: Replace existing 1200 gal septic tank(2nd tank, before the
Permit Description: drainfield)with 1200 gal Infiltrator IM-1250 tank for system located on
the north side of 130 W Corporate Rd facility
Permit Submitted Date: 03/26/2026
Permit Issued Date: 04/01/2026
Issued By: David Anderson
Current Permit Fees Paid: $275.00 (additional fees may be required upon installation of system).
Permit Expiration Date: 03/26/2026 (based on date of inspection)
Type of Work OSS Repair
Components being Replaced: Septic Tank Only
Surfacing Sewage? No Existing Failure? Yes
Shoreline? No Horizontal Setbacks Met? Yes
Number of Bedrooms: 0 Drinking Water Source: Public Water System
Additional Details: Infiltrator IM-1250
Permit Conditions:
I Approval of this septic permit does not approve the building location. Building location is
subject to approval from all applicable departments and regulations.
2 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is
obtained
3 Permit must be installed by a Mason County Certified Installer unless prior written
authorization from Mason County is obtained.
5 Proposed development subject to zoning requirements and approval by the planning
department staff per Mason County Title 17.
4 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for
final installation approval.
THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS.
PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS.
THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN
APPROVED.
FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES.
For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call:
360-427-9670, extension 400.
IM �Tanks
IM-1250
yy�
*�R
"l�y� er
The Infiltrator IM-1 250 is a lightweight, strong and
durable septic tank. This watertight tank design is
offered with Infiltrator's line of custom-fit EZsnap
risers and heavy-duty lids. Infiltrator injection
molded tanks provide a revolutionary improvement IM-1250
in plastic tank design, offering exceptional long-term
strength and watertightness.
Benefits
Strong injection molded Lightweight plastic con- Integral heavy-duty green Structurally reinforced
polypropylene construc- struction and inboard lids that interconnect with access ports eliminate dis-
tion lifting lugs allow for easy EZsnap risers, Safety Star tortion during installation
delivery and handling secondary safety lid sys- and pump-outs
tern, and pipe riser
Reinforced structural Can be installed with 6"to Suitable for use as a septic No special water filling re-
ribbing and fiberglass 48"(152 to 1,219 mm)of tank, pump tank, or rain- quirements are necessary
bulkheads offer additional cover water(non-potable)tank The tank may be backfilled
strength with suitable native soil.
TANK CUTAWAY Partition baffle wall
Infiltrator
EZsnap Riser
System
` HEAVY DUTY LID CUTAWAY
l i
Reinforced 24"structural access port
a
i, Structural
bulkheads
CUT SEAM �nfiitrator
'��.___ `� � CUTAWAY
Reinforced Water Technologies
\ � water Part
tight
infiltratorwater.com•(800)221-4436
IM-1250 General Specifications and Illustrations
The IM-1250 is an injection molded two-piece mid-
LIFTIN STRAP(TYP.) LIFTING LUG(TYP.) RISER CONNECTION(TYP.)
seam polypropylene tank.The injection molded
design of theIM-1250 allows for a mid-seam joint that
has precise dimensions for accepting an engineered 61.7
EPDM gasket.The engineered mid-seam joint accepts ® EXTE IROR
a continuous loop EPDM gasket. Infiltrator's EPDM WIDTH
gasket design utilizes technology and materials from
the sanitary sewer pipe industry to deliver a reliable 152.3[3 868)___________
watertight seal. The two-piece design is permanently EXTERIOR LENGTH
fastened using a system of molded-in alignment
dowels and locking
TOP VIIEW
Must be backfilled and OUTLET PIPE
mP)
installed in accordance
�,�$ e ■ with the Infiltrator IM-
and CM-Series Septic Tank 54.6
f 6•. General
L'•" [1,387)
•.---y,1.I p• e.8
•:■.� INFILTRATOR"; EXTERIOR
L■�,•;■ ■■■; SEAM CLIP H IGHT
For shallow ground water
• •. "• °•":.�3 Installation Instructions. (TYR)
•• .•'mow N.
;„ ••;�;;"• aLIFTING STRAP
• Y" conditions reference the (TYP)
Infiltrator IM-and CM-Series
Tank Buoyancy Control SNIDE VIIEW
Guidance.
Please visit www.infiltratorwater.com or scan QR i5R
12024.0[610 ACCESS PORT
code for the latest information. ITH LOC LNG LID(2) 10.0[254]FREEBOARD PV [OR
PVC OR ABS
OR OUTLET TEE
6.3% / /_AIR SPACE O
i 0.2[5]WALL
THICKNESS
Working Capacity 1,278 GAL(4,839 L) 44.0[1,118] PER CODETotal Capacity 1,480 GAL(5,602 L) LIQUID DEPTHAirspace 16.30%
Length 154" (3,911 mm)
Width 61.7" (1,567 mm) END VIIEW
Length-to-Width Ratio 2.8:1 CONTINUOUS
TANK TOP ELASTOMERIC
Height 54.6" (1,387 mm) HALF GASKET
Liquid Level 44"(1,118 mm)
SEAM CLIP
Invert Drop 3"(76 mm) (72)
Fiberglass Supports 4
INTEGRAL ALIGNMEN
Compartments 1 or 2 DOWEL
TANK BOTTOM
Maximum Burial Depth 48"(1,219 mm) HALF
Minimum Burial Depth 6"(152 mm) MIIID-HE�IIGHT SiE/�M SECTIION
Maximum Pipe Diameter 4"(102 mm)
Weight 405 Ibs(184 kg)
Contact Infiltrator's Technical Services Department for assistance at
1-800-221-4436 or info@infiltratorwater.com infiltrator
Part
TRA)G nric
`MAS N COUNTY HEALTH DEPARTMENT 1 ,l zy;y
L �y 428 WEST BIRCH STREET`
SHELTON, WASHINGTON 98584
PHONE (206)426-5561 •. U TY
`" YRECORD OF FINAL INSPECTION OF YOUR SEWAGE DISPOSAL SYSTEM
OWNE ADDRESS ."d S'g
THIS RECORD IS NOT A GUARANTEE OF PERFOR NCE. DESCRIPTIO
A SEPTIC SYSTEM IS NOT A MUNICIPAL SEWER. HOWEVER
WITH PROPER MAINTENANCE AND CAREFUL USE OF ), ! .{f
WATER IT CAN GIVE MANY YEARS OF TROUBLE FREE SER-
VICE. MANY PROBLEMS WITH SEPTIC TANKS ARE CAUSED SOIL 1)
COMMENTS t
BY FLUSHING EXCESSIVE AMOUNTS-OF PAPER, CLOTH . FIELD
AND PLASTIC MATERIALS DOWN THE DRAIN, OR BY SITE SIZE X
LARGE' AMOUNTS OF WATER FROM'LEAKY FAUCETS OR NO.
FAULTY FIXTURES. DEPTH TO ,t MONTH
WATER TABLE � OF YEAR (,L/yLJ�.-�
THE SEPTIC'TANK ITSELF SHOULD BE CLEANED EVERY TALLER
TWO OR THREE YEARS DEPENDING ON THE HABITS OF THE
FAMILY, THE NUMBER OF FIXTURES IN THE HOUSE, AND SIZE
THE AMOUNT-THAT A.GARBAGE DISPOSAL IS USED.CLEAN- SEPTIC TANK (S) Ip?0
ING AT THE RIGHT TIME WILL.AVOID THE RISK OF INJUR- DRAINFIELD FEET
ING OR DESTROYING THE DRAINFIELD DUE TO SOLIDS LENGTH
CARRYING 'OVER INTO THE DRAINFIELD. CALL THE TRENCH AREA SQ. FT.
MASON COUNTY HEALTH DEPARTMENT FOR A LIST OF d
LICENSED SEPTIC TANK CLEANERS IN YOUR AREA. THE `
CLEANER CAN SERVE YOU BEST IF YOU SHOW HIM THIS DEPTH ! " ❑ CORRUGATED `,RIGID ❑ CEMENT
RECORD WHEN HE COMES. DEPTH
0 c
(Q 3�
HEAVY TRUCKS OR EQUIPMENT SHOULD NEVER BE ROCK / /� BELOW 5y/` D PTH
CU. YDS. PIPE
DRIVEN OVER THE TANK OR DRAINFIELD. CONSULT THIS SPACE RESERVED FOR
RECORD IN CASE OF ANY BUILDINGS, DRIVEWAYS, REPLACEMENT DISTRIBUTION FIELD: SQ. FT.
SWIMMING POOLS, OR EXTENSIVE GRADING OR FILLING NO Thi ` "
ARE LATER CONTEMPLATED.
SHRUBS OR TREES SHOULD NOT BE PLANTED CLOSE TO '. .. :..:. .; . ; .
THE SEPTIC TANK AS THEY WOULD INTERFERE WITH
CLEANING OF THE TANK. THEY CAN BE PLANTED IN THE
DRAINFIELD AREA PROVIDING WILLOWS ARE NOT USED. D
THE YARD GRADE IN THE DISPOSAL AREA SHOULD BE �r 2!
SUCH THAT SURFACE WATER IS NOT POCKETED ON THE 1
DRAINFIELD. ANY SETTLING OF THE GROUND OVER THE
TRENCHES SHOULD BE FILLED IN WITH SOIL. DO NOT EX- '
CESSIVELY WATER THE LAWN IN THE DRAINFIELD AREA. �,
WATER EVAPORATION FROM THE DRAINFIELD IS ABOUT 33
EQUAL TO ONE HALF INCH OF RAIN PER DAY.
FOOTING DRAINAGE, DOWNSPOUTS AND WATER
SOFTENER RECHARGE WATER SHOULD NOT BE CON-
NECTED
TO THE SEPTIC SYSTEM OR DISCHARGED INTO THE
DRAINFIELD AREA.
THE TYPES OF BACTERIA NEEDED IN A SEPTIC TANK ARE Pe ►nS(41(e'"oI\ y r 1(toz6: ran I Lx3d)99
AtWAYS FOUND IN SEWAGE. THERE IS NO NEED TO ADD ref(gced J5 fke sew one, befor- dC41eLt
YEAST OR OTHER STARTERS TO A SYSTEM. THE USE OF RE-
JUVENATORS OR CHEMICALS TO CLEAN A SEPTIC TANK
HAVE NOT BEEN PROVEN TO BE BENEFICIAL AND MAY BE
HARMFUL BY FLUSHING SOLIDS OUT OF THE TANK OR BY
CHANGING THE CHARACTERISTICS OF THE SOIL. THE
NORMAL USE OF BOWL CLEANERS OR CLEANING COM- SOUTH
POUNDS WILL NOT KILL THE BACTERIAL ACTION OR SLOW
DOWN THE OPERATION OF THE SEPTIC TANK.
THISCISfyAN IMPORTANT
^�DOCUMENT DATE c APPROVED BY
s �.,'�,.F;t'F .: •Y,r itiv'� 3.nIl4T`a� ;Wllii�lL"CK?a,�7i�C"•,i`'.ATf7 <i.g rxS?�x� o:<;y, l
1M 0 s} I L .:�n zSSNi4LC �' , � � bAT �# CERTIFIED BY