HomeMy WebLinkAboutBLD2026-00108 - BLD CD Environmental Health Review - 3/31/2026 survey to obtain a building permit. As a result site APPROVED Front Yard Setback. 25'. L p%
1 MASON COUNTY DCD PLANNING
plans may not reflect accurate data. It is the 5C07TRUEiDY,A10 Side& Rear Yard Setbacks. Residential dwelling
and accessory structures is 20'.
applicant's responsibility to comply with setback ^) OR 10%width of lot if not more than 100 wide
requirements. s,n,R.dy - = OR approved ADV
APPLICANT i TT17 1 7J The approval of this project is subject to the re mmendations
�— .
PIROE, FRANCIS&ROSEMARIE %�------- -- _ _ and specifications outlined in the attached geot chnical report.
SITE ADDRESS LEGEND . ,.-' I —� applicable recommendations and specifications shall be applie(
1 to the development on this site. Any deviation quires stampe
371 E GREEN WAY
cRAPEVIEW, W W �
A. 96546 ® \ 30FT EASEMENT
rn ' "•= _ ° 1 written approval from the registered design pro ssional
PROPOSED PROJECT G] t
SITE INFO \ i ® 1 responsible for the report and may require spe al inspection b�
TAX PARCEL NUMBER: 22113-56-06032 EKING HOUSE Z ...
--- r same. Structures and/or land modifications(gr ding,cuts,fills,etc.)required in the geotechnical report,may rquire a separate
LEGAL DESCRIPTION DESRNG DECK y 1 _permit.The geotechnical report shall remain attached to the
M STADIU 13PACH(UNRRCOROCo)71Ln / T a roved buildin lans.
OFTR517-IH&V67H INTTRI$7L CRISIING CONCRETE APRONc
/ , ~ _ _
JURISDIc71oN CR���A�-DRAY / - •// 1
MASON COUNTY FENCE \ / „ , 1-
----- PROPERTY UNE \\ ' EH Setbacks
PROPERTY INFO
CENTER OF ROADWAY '' ; , 1 A.) Drainfield/Reserve requires 10'setback from oting/foundations
�— CONTOUR LINES / / 1 B.)Septic tank(s)requires 5'setback from all foot i ig/foundations
SETBACK REQUIREMENTS 25FENRS 'C)No foundation/Perimeter Drains within 30ft,d ngradient of
FRONT 25FT— 25Fr REAR — SFi/SIDES BLDG. OUTLINE EXISTING / / / �r Drainfield/Reserve area
DISTURBED AREA DRAINAGE D. No Cut Banks (greater than 5ft and over 45 egrees)within
LOT =56,606 S.F.—/1.35 ACRES SEPTIC SYSTEM \I\ / 50ft,down gradient of Drainfield/Reserve area g )
DISTURBED AREA= 707195 S.F. 17.94% — — SETBACK LINES I\ , .I E.)Use approved mitigation from section C1-9 of he department of
UNDISTURBED AREA -51711 S.F. 0 67.947. .w.�.�..w..., SILT FENCE (IF REQUIRED) \ /
SAS.B FENCE (IF REQUIRED) I r / 1 ecology's"Criteria For Sewage Works Design,"wl en sewer
® LOT CORNER I 1 eepo t lines are within 10ft of water supply line .
OD BLDG CORNER / \\ //
WATER METER EXISTING j / �'' /\ 1
IMPERVIOUS SURFACE CALCULATION G POWER POLE EH APPROV D
0C0 CLEAN OUTS DRIVEWAY // \ I / (1
PlupmEa eesi a DOWN SPOUTS \ :�' • / Rhonda Thompson 03/ 1/2026
A n STRUCME 1054 S.F 10154 S.F —W WATER LINE i�r\ r I / ( 1
D SmON 0 SF• 3315 S.F. --LV3--&)--SEWER UNE O / \ I • \
c RYA ELECTRICAL METER \ I
0 sF. On� POWER OVERHEAD I 1 1 � \•�
_
D RrvLwA7 5340 S.F. 5 SF 340 . 9) GAS LINE / \
E P CUhR_PORCH,SHeD 4Rs SF. 355 st. B TYPE I C.B. W/CLEANOUi / y�\ '
F EXISTING HOUSE \
I
a IL(40+0+15+w EXISTING TREES E+F� 15.15015 sF 7,0a5 sF. % II 1
°
DT 11.71% 12015 CONNECT DOWNSPOUT r \\ ° ° ' • }
,q�
K 1 51515015,435150_,,, TO TIGHT LINES ° ) I
I /
L J m I(-WERIOUS SURFACE 7045 S,i 55055 S.F. - / 1 I
I (
INSTALL SILT FENCE ' / 1
{
NO TREE ARE BE REMOVED FROMTH
ADV2026-00015 SIDE SETBACK 5' MIN \ ' / /J
EXISTING TREES TO REMAIN 1
TO E SITE
70' \\� / ./ ) /
VICINITY MAP SITE AERIAL VIEW WELL HEAD 65 \;' / ii-4' "
FEMA\'FIRM 45-\-c .. /
11X17 FOR SCALE WATER Z1Nt , 30 \k
Walker} •
'
Ln7den0 f, r. V ,J '.
,. �... ( s SITE P IN -
Ti GRAPHIC SCALE: 1,'=40' \\\f! {1 it "74
-%
0 20' 40' 3jjJ \\/////��.