Loading...
HomeMy WebLinkAboutBLD2026-00260 - BLD CD Environmental Health Review - 4/7/2026 1 as - 3�k• c 0c c tc jj3caLc - 04/02/2026 a�'aCoO APPROVED EASEMENT/FRONT ADV202600031- FRONT 1 MIN FROM All setbacks are measured from the furthest MASON COUNTY DCD PLANNING EASEME SETBACK seorrPZu�yaiep u3 projection of the building. \ S EXISTING 4 BDRM RES Ni N\\ O EXISTING SHOP!GARAGE EH APPROVED L_. O3 WELL EXISTING DRIVE ,SCALE-1 1,=60 -0" �% ; \\ WELL O4 EXISTING SEPTIC TANK(PER 1976 PERMIT/INSTALLATION)FAILED(ABANDON PER CODE) Rhonda Thompson 04/07/2026 5O EXISTING D.F.(FAILED DUE TO AGE)-ABANDON \'I NOTES: \ \ O PROPOSED 3 BDRM ADU(ADU NOT INSTALLED YET-UNDER SEPARATE PERMIT) RESTRICTIVE LAYER BELOW 48' r \ O7 DRIVE -FIVE TIMES RULE MET \ -NO WELLS WITHIN 100'OF DRAINFIELD \\ ft 8 ADU CLEANOUT/SEPTIC TANK!PUMP CHAMBER -ELAPSE TIME METER AND EVENT COUNTER REQUIRED \ RISERS TO SURFACE REQUIRED OVER ALL TANK LIDS \ Og EXISTING STUBOUT/CLEANOUT FOR PRIMARY RES(IE.-88.0) Water NN\ 10 PROPOSED 1200GAL.SEPTIC TANK(IN.EL.-875/OUT EL.-87.2) SOIL LOGS RBM IS GROUND EL.@ SHOP C RNER(RBM=100. ) \\ 11 PROPOSED 1200GAL.PUMP CHAMBER(PUMP EL.-84.0) 1) LOAMY MED.SAND 0 26" 7 _ 12 900F2 DRIP DRAINFIELD(25FTX36FT)-4 LATERALS-15OFT EACH(IE.-107.5) VERY GRAVELLY LOAMY MED SAND 26-54" \N\ \\ � `, •1 2) SANDY LOAM 0-36" 13 900FT2 DRIP R/A \ j •, /� MEDIUM SAND WITH FAINT MOTTLING 36"+ 5 \ \ \ 3) SANDY LOAM 0-36" \ \ MEDIUM SAND WITH FAINT MOTTLING 36"+ N '•I \ � 2 . \ 4) SANDY LOAM 0-30" \ i cP o \ BLD2026-00260 VERY GRAVELLY MEDIUM SAND 30-48" u: � � li N 5) LOAMY MED SAND 0-30" i v \ \ VERY GRAVELLY MEDIUM SAND 30-48" O� I \\ EH Setbacks TANK DETAIL-NO SCALE 12 ADU DRIP DRAINFIELD D 1'' \ \ \.; \\ A.) Drainfield/Reserve requires 10 setback from footing/foundations \ \ B.)Septic tank(s)requires 5'setback from all footing/foundations \ C.)No foundation/Perimeter Drains within 30ft,downgradient of 115 120 \ Drainfield/Reserve area 125 D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area i' E.)Use approved mitigation from section C1-9 of the department of ecology's"Criteria For Sewage Works Design,"when sewer transport lines are within 1 Oft of water supply lines. II SEE DETAIL \ AA ;• \ \ u 1 0' 02/24/26 � Front Yard Setback. 25'. HEADWORKS(SEE DETAIL PG 2) �tio J J ' n" ADALI J.IIUNTCR _ Side & Rear Yard Setbacks. Residential dwell PUMP CHAMBER(�YPICAL� and accessory structures is 20'. ( / 9 // OR 10% width of lot if not more than 100' wide 11 THIS IS NOT A SURVEY: OR approved ADV SITE FEATURES,TOPOGRAPHY,ELEVATIONS AND BENCHMARKS ARE BASED ON ASSUMED DATUM / PROVIDED BY THE OWENER AND COUNTY PLANNING RECORDS AND ARE INTENDED ONLY FOR THE 2 REVIEW AND CONSTRUCTION OF THE PROPOSED SEPTIC SYSTEM DESIGN.JIM HUNTER&ASSOCIATES RECOMMENDS THAT A LICENSED PROFESSIONAL LAND SURVEYOR ALWAYS BE USED TO SET CORNER, ESTABLISH LOT LINES,DETERMINE ELEVATIONS AND TOPOGRAPHY AND/OR PROVIDE A LEGAL SITE PLAN. NAVD88 IS UNKNOWN 12 CONDUCTED TOPOGRAPHIC ANALYSIS OF SITE,DETERMINED TRENCH DEPTH IS SUITABLE GIVEN SITE CONDITIONS. A FEE MAY BE CHARGED AFTER INSTALLATION FOR FINAL INSPECTION&RECORD DRAWING \ HWY 302 TO A LEFT ON QUAIL HILL JIM HUNTER AND ASSOCIATES 220'-1"SCH40 SUPPLY/RETURN LI ES TO SITE ON THE RIGHT. P.O.BOX 162,OLY,WA 98507 753-1226 JH SOASSDCIATESQHDTMAILCDM F DESIGNER-ADAM HUNTER SEPTIC SYSTEM DESIGN FOR- 13 Disclaimer: Mason County does not re uire a , \,,\ ' ", q,�N MIKE YOUNG \ w I44 SITEADDR- survey to obtain a building permit. Asa `result, Site \ N 90EQUAILHILLRD(PRIMARYRES) 36' LEGAL- 1 OF 2 plans may not reflect accurate data. It i ''tk� 5 SCALE-1"=60'-0 TP# 122093490090 SITES applicant's responsibility to comply with setback requirements.