Loading...
HomeMy WebLinkAboutBLD2026-00126 - BLD CD Environmental Health Review - 4/8/2026 3 a,aa'4 - -1 5 - o o LCbo '� P - £G «.C-e v / ` PROPERTY ADDRESS: 480 NE HURD ROAD •* EH APPROVE® -_ SldeStreet- NEHURDRD. -- -_ _ — \ BELFAIR WA 98258 1 _ �zF_ - I \ JURISDICTION: MASON COUNTY Rhonda Thompson 04/8/2026 I ; 13•-7• ` 15'EASEMENT LINE PARCEL#: 32224-75-00100 �0 _...Ra ------------------ L m / _— — -"`•:.::�u� ---- ----- ------ I _—_ E%ISTING GATE— \ ----------------� w ( --- —1 / I I ----- -- --------- I---------1 DESCRIPTION: In 100FSURVEY4/136 I / I I' II I I II OWNER: MARK BUNTINS gw , / I I I I I I II mbunlons@gmail.com - --- \ J yv .' __ I I I I I I I I EXISTING, I W y l 4 I I ' ; WELL ZONE: RRS r�i w Y; ""'°"'�"• � - I I I i EXISTING ] HOUSE BUILDING FOOTPRINT: 476850 FT �" ! P,nwa .w., I I I WELL r r I I ( I lr C I PROPOSED DRIVEWAY: 758 SO FT ,,II \ I / I ¢w I _ -- \ I LOT SIZE: 217,800 SO FT/5 AC F ti / MIN FRONT: 25' T o ' / I MIN RIEAR: 20' -- I� _ ` I I / MAX HEIGHT 35' wsnr senw - I N 4/7 //' WATER: PRIVATE WELL.,� I - I I I I / SEWER/SEPTIC: SEPTIC I I ,,/ I ROADACCESS: PRIVATE 1 ice/ EXISTING qe°1NALr o?iz32D26 I II I I I I I BARN I I _ I ❑ --- --- I D ,gd. DESIGN CRITERIA ql 2 I II - .I I I I I I LOT COVERAGE CALCULATIONS I II I I I I I Z II I I I SEPTIC L LOTSIZE: 217,800 SF II PROPOSED SFR(ROOF): 6262 62622 SF III EXISnNG SYSTEM II ( ENTRY GATE II I I I I I p I I %LOT COVERED BY BUILDING=2.9% I I I EXISTING DRIVEWAY Z o-m' g ii c RESERVE W �i AREA I �, PROPOSED I LEGEND WATER PROPERTY LINE o i METER «I I« ® PROPERTY CORNER EH Setbacks I ; ; GRAVEL DRIVEWAY A.) Drainfield/Reserve requires 10'setback from footing/foundations B.) Septic tank(s)requires 5'setback from all footing/foundations PROPOSED SFR C.) No foundation/Perimeter Drains within 30ft, downgradient of I I Drainfield/Reserve area I 123-" I D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area E.) Use approved mitigation from section C1-9 of the department of I I m 3 x ecology's"Criteria For Sewage Works Design,"when sewer i i ¢z Z LL SQUARE FOOTAGE ¢ m transport lines are within 1 Oft of water supply lines. EXISTING MAIN FLOOR 3685 SF m DRIVEWAY I UPPER FLOOR 361 SF W-� TOTAL 4046 SF ':.I.'. CONCRETE GARAGE 895 SF ENTRY APPROVED _ b°. .'.'.'I.'.(.".'.'. _ ' I (........ PLANNING SETBACKS wo. 2062 m_. MASON COUNTY DCD PLANNING ...I_I....... AMG Setbacks measured from .I..I...'....'. PROPOSED SFR I i Y ovlazozs VERSION 1 SITE PLAN REQUIRED TO BE ON SITE I ; U I farthest projection of structure 03232026 CORR1 �' I I 10-7. E PATIO ,/ M I Front: 10' ADV2026-00030 CHANGES SUBJECT TO APPROVAL �,_� � � COVRED� ___� I I� W Rear: 20' By: Date: 03/24/2026 Approximate end of Y �_ *Subject to EH Setbacks road easement per l�- I **Must meet 25' slope setback Disclaimer: I - " survey. AFN 356847 I Mason County does not require a survey to obtain a I "-"col ,. I N building permit. As a result, site plans may not reflect Isidel SITE PLAN accurate data. It is the applicant's responsibility to I ; I 1" — 20' SP comply with setback requirements. ; ; ;Z