Loading...
HomeMy WebLinkAboutSWG Letters / Memos - 3/30/2026 Rhonda Thompson 4 a I v a - �4 -U C ZX)() From: James R. Moehring <jmoehring@bassettiarch.com> Sent: Monday, March 30, 2026 8:06 AM To: Rhonda Thompson Cc: Kristian Kicinski;Todd Sawin; Murray Longbotham Subject: RE: COM2026-00013 - HCSD Attachments: SWG2019-00188 - SWG As-Built- 5_28_2019.pdf Rhonda, Thank you for your comment responses back. I'd like to clarify our design population response: No significant increase to the current student and staff population of approximately 380 on site is anticipated.The total population will not exceed the 575 from the 2019 septic design.The proposed modifications to the school building provide the adequate space needed for student services and electives that are already staffed and provided in the school.Similarly,the Transportation Building users will relocate from the school building and the old bus building and the number of people will not change.The discrepancy in the occupant count shown in the plumbing calculations stems from the maximum occupant load calculations performed per the IBC, not the actual anticipated population.We can revise the plumbing count calculation to show 380 occupants, if that will improve the clarity of our submittal. James R. Moehring AIA, LEED AP BD+C Design Leader aOOL Li 100%Employee Owned architects a 7t7G"' D 206.504.7657 A Design St,,dlo ofHMCA,h#ct Download Architecture of Healing Bassetti Joins HMC Architects From: Rhonda Thompson<RThompson@masoncountywa.gov> Sent:Thursday, March 19, 2026 2:01 PM To:James R. Moehring<jmoehring@bassettiarch.com> Subject: RE: COM2026-00013-HCSD Thankyou for the update. I am going to comment further here in BLUE: 1) Please provide number of current students/staff who use the septic system and number of anticipated additional students/staff that may be added as a result of this permit approval.The existing septic system was upgraded in 2019 under septic permit SWG2019-00188, and it was designed to serve a maximum population (students+adults)of 575. If the proposed development will increase the population that is using the septic system to more than 575 people,or if there is any structural or use change that would result in an adverse impact on the existing septic system,you will need to contact a licensed Septic Designer to design one or more septic systems that address anticipated flows and waste strengths. -The total 575 design population is confirmed in the attached As-built plans.The increase in population can be found on G2.11 for the school(627 occupants). 1 It sounds like you will need to upgrade the septic system to accommodate those higher flows. Please contact a Licensed septic designer. 2) Part of the drainfield actually appears to be on a separate parcel 421 02-34-60030. Please provide documentation of an easement. -The drain field is indeed in the parcel 42102-34-60030,which is owned by the HCSD.We cannot find documentation on an easement. Please file a Declaration of Covenant.An example template is attached for your convenience,along with recommendations on how to get it recorded. Please provide us a recorded copy. 3)Will there be any increase in waste strengths as part of this proposal?Think additional wastes from art classes, labs,etc. If so,we will require a licensed septic designer ensure the existing septic system can handle the increased waste strength. -No.While the septic field does support a school, including art classes,tabs,etc, however this is not beyond the original design scope.The HCSD Modernization project does not modify or add to the list of potential discharges into the septic field,other than an increase in service load, due to the additional classrooms. Thank you for the clarification on waste strength. It still looks like you will need to upgrade the system to accommodate the added population. 4) Based on google satellite imagery, it appears the proposed transportation building may encroach on to the drainfield. Please see attached plans with markups. I can actually see the drainfield from satellite imagery because it's greener than the surrounding lawn area. I believe you are showing the drainfield area on your site plan farther south than it actually is. -The drain field is demarcated by the edge conditions-physically identified in field by the location of cleanouts. These cleanouts are outside the transportation building, and not within site improvement areas.See attached drain field exhibit.The width of the drain field if approximately 127'. Thank you for providing the site plan showing the 1 Oft setback from the proposed transportation building to drain₹ield. 5)We require a satisfactory Operations and Maintenance inspection on the septic system within the last year. Please let us know once complete. -Noted.See attached. It looks like AAA went back into their 2025 report to update/edit it.The report notes a deficiency. I am also unable to pull up this report myself,as they may still be working on it.You should be able to see it by searching: https://www.onlinerme.com/contractorsearchproperty.aspx 6) Lastly, regarding water adequacy, additions to existing buildings are exempt. However, any new detached structure with plumbing will require a signed water adequacy form.Are you permitting the transportation building at this time, or just the art/library/stem addition? -A signed water adequacy form will be provided for the new transportation maintenance building. I see the new Water Adequacy form you submitted. I am not able to verify the information on it.This water system "Skokomish Community Water System ID#IH738H" does not come up in the DOH database. I think your water 2 system is called "Hood Canal School District 404 ID#34035P"and the water system manager is John Hart who will need to be the one signing the form.Can you took further into this?I have attached the WE!form I found for the Hood Canal,School District 404. 7)Our food program staff may reach out with additional requirements,separate from the septic/water review. -Noted. Thank you, Rhonda Thompson, RS Senior Environmental Health Specialist Mason County Public Health 415 N 6th St.Shelton,WA 98584 360-427-9670 ext.581 Rthompson(5masoncountywa.gov From:James R. Moehring<imoehring@bassettiarch.com> Sent:Wednesday, March 18, 2026 4:13 PM To: Rhonda Thompson<RThompson@masoncountywa.gov> Cc: Kristian Kicinski<kkicinski@bassettiarch.com>;Amy Broska<abroska@bassettiarch.com>;Todd Sawin <tsawin@ahbl.com>; Murray Longbotham <mlongbotham@ahbl.com>; Genie McFarland <Gmm@masoncountywa.gov>; Igibbon<Igibbon@hoodcanalschool.org> Subject: RE: COM2026-00013-HCSD Rhonda, Thanks for your questions. Below in red are responses to your questions.Attached is the latest Operations and Maintenance inspection on the septic system as wells as a plan showing the drain field extents. Please let us know if there is anything else you need. 1) Please provide number of current students/staff who use the septic system and number of anticipated additional students/staff that may be added as a result of this permit approval.The existing septic system was upgraded in 2019 under septic permit SWG2019-00188, and it was designed to serve a maximum population (students+adults)of 575. If the proposed development will increase the population that is using the septic system to more than 575 people,or if there is any structural or use change that would result in an adverse impact on the existing septic system,you will need to contact a licensed Septic Designer to design one or more septic systems that address anticipated flows and waste strengths. -The total 575 design population is confirmed in the attached As-built plans.The increase in population can be found on G2.1 1 for the school(627 occupants). 2) Part of the drainfield actually appears to be on a separate parcel.42102-34-60030. Please provide documentation of an easement. 3 -The drain field is indeed in the parcel 421 02-34-60030,which is owned by the HCSD.We cannot find documentation on an easement. 3)Will there be any increase in waste strengths as part of this proposal?Think additional wastes from art classes, labs,etc. If so,we will require a licensed septic designer ensure the existing septic system can handle the increased waste strength. -No.While the septic field does support a school, including art classes, labs, etc, however this is not beyond the original design scope.The HCSD Modernization project does not modify or add to the list of potential discharges into the septic field,other than an increase in service load, due to the additional classrooms. 4) Based on google satellite imagery, it appears the proposed transportation building may encroach on to the drainfield. Please see attached plans with markups. I can actually see the drainfield from satellite imagery because it's greener than the surrounding lawn area. I believe you are showing the drainfield area on your site plan farther south than it actually is. -The drain field is demarcated by the edge conditions-physically identified in field by the location of cleanouts. These cleanouts are outside the transportation building, and not within site improvement areas.See attached drain field exhibit.The width of the drain field if approximately 127'. 5)We require a satisfactory Operations and Maintenance inspection on the septic system within the last year. Please let us know once complete. -Noted.See attached. 6) Lastly, regarding water adequacy, additions to existing buildings are exempt. However, any new detached structure with plumbing will require a signed water adequacy form.Are you permitting the transportation building at this time,or just the art/library/stem addition? -A signed water adequacy form will be provided for the new transportation maintenance building. 7) Our food program staff may reach out with additional requirements, separate from the septic/water review. -Noted. Thank you, Rhonda Thompson, RS Senior Environmental Health Specialist Mason County Public Health 415 N 6`h St.Shelton,WA 98584 360-427-9670 ext.581 Rthompson(cbmasoncountywa gov 4 James R. Moehring AIA, LEED AP BD+C Design Leader basseffi,pEeN p� 100%Employee Owned architects G?f? ? D 206.504.7657 A O fgn Smdia of MCArchirocts Download Architecture of Healing Bassetti Joins HMC Architects 5