HomeMy WebLinkAboutBLD2023-00354 Expired Retaining Wall Bulkhead - BLD Inspections - 4/20/2026 MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 COMMUNITY SERVICES SHELTON: 360-427-9670,EXT 352 BELFAIR:360-275-4467,EXT 352 BuJdmq Pl ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http:/twww.co.mason.wa.us/community-serviceslbld-inspection.php Permit Number BLD2023-00354 Date Issued 04/24/2023 Issued By L Project RETAINING WALL INSTALLED BEHIND EXISTING FAILING WALL Site Address 11831 E STATE ROUTE 106 �' t Applicant HILLS JASON ROBERT&KATE?CHRISTINE Contractor INTERGRATED NW CONSTRUCTION LLC Contractor Phone 253.888.5314 2018Primary Code UPC Type IBC,IRC,IFC,IEC,IMC,& Type Permit Type BULKHEAD OR DOCK- Occupancy RESIDENTIAL -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.** PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks S is Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls p. - ZAi f OtherE - Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other 44 3 D -"eft' -1?y2- M c\al SVecA'� J S -.-- kF I MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 3 360-482-5 69 Elma exit.352 Building,Planning,Environmental Health,Community Health 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: EL D 2o3 -Qo ADDRESS/LOCATION: f E rM6 gt�TE /06 FINDINGS: 4 r r^ 1¢ - t s . C cJ r tP n i. ra ie.Ss .._ rOyr C.- do)'/ tl¢! S 4f' 5hot)'t it Cr© S .S`�c rdntt. C roSS Sc� {•ter, � also/ APPeA 5 /e.S ; - . As5 o //► Jr.' L/ S Q I4c< (�4/ ; lsr 1n TI5// aJ6k '1V..2C - S yerc, I / 'i e l t,r& ç/( 54 /)e m ¢ neer -&�,' € S4..% teAc ft Mat/ itt.J 'I- V 7CC' )tou. a er e - 1 �vr. iCc�.Jr� t?'tdQ• R t h S il M l3n tC�t'�l r Cq 1 j ;n (L O M/SWCAJA T , 60V Items listed above must be corrected to gain compliance. [] THIS IS NOT A COMPLETE INSPECTION [] This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. r Make corrections, items will be checked on the next inspection. OK to P,o e.T AziioS G nc Q" °'t Date: [ii Please contact our office regarding possible Department: structural damage incurred by recent Inspector: j �j "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 INSPECTION RESULTS Pagel MASON COUNTY Department of Community Development COMMUNITY DEVELOPMEN'C 615 W Alder St, Shelton, WA 98584 Permit Msistance Center,Budding,Planning (360) 427-9670 ext. 352 Application# BLD2023-00354 Application Type BULKHEAD OR DOCK- HILLS JASON ROBERT& pp pp RESIDENTIAL Owner KATEY CHRISTINE Parcel# 222302190030 Site Address 11831 E STATE ROUTE 106 UNION, WA 98592 Inspector Inspection Type Date Status Comments 6-5-25-JQ Joshua BLD-FINAL INSPECTION 06/05/2025 FAIL 1. FOR LETTER DOES NOT HAVE A STAMP PLEASE CONTACT FOR AND HAVE Quarders HIM CORRECT THIS DEFFICIANCY BEFORE FINAL CAN BE ISSUED I�cc,+►�4 lshs June 2,2025 Page 1 of I MET Engineering, PLLC To: Mason County Building Department 615 W. Alder St. Shelton, WA 98584 (360)427-7262 cc: Integrated NW Construction,LLC 60 N Lake Cushman Rd, Suite 109 P.O. Box 1008 Hoodsport, WA 98548 Subject: ENGINEERING LETTER REGARDING the REBAR PLACEMENT FOR THE NEW EAST BULKHEAD as well as PLACEMENT OF THE REBAR IN THE RAISED 2' SECTION OF THE NORTH,I.E.,THE WATER SIDE BULKHEAD at 11831 E SR-106,Union,WA 98592 This engineer has verified that double #5 vertical rebar has been placed within the new east bulkhead wall as can be seen in photograph#1 on Sheet 1.0 per the approved engineering drawing dated April 10, 2023. The #5 vertical rebar has also been spaced 2.0' on-center as called out in the drawing. Also, an invoice has been attached that shows that thirteen 20-foot lengths of#5 rebar was sent to Integrated NW Construction on April 20,2023 that was used in the construction of the Jason Hill's new east bulkhead retaining wall. Also,this engineer has attached photos of the epoxied rebar for the 2' raised section of wall on the Hood Canal side of the property as indicated in photographs #2 through#5. An air compressor was used to blow out the concrete powder from the all the drilled-out holes at their proper depth and then a bottle brush was then used to further clean out the holes. Rebar can be seen in Photo #5 and the final 2' raised retaining wall can be seen in Photos#6 and#7. It is the conclusion of this engineer that the construction of both the east bulkhead as well as the north 2' x 104' raised retaining walls were constructed properly to match the existing concrete retaining wall. Any questions or comments can be addressed by e-mail at Smortth I.aol.com or by calling this engineer directly at(360)310-0270. Respectfully Submitted. �rl P.4. Steven P. Morta.P.E. Principal �'o (360)310-0270 �S�0NALL��` 2 ZoZ 800 E. Wishkah St., Aberdeen, WA 98520,(360)310-0270. SMortau:aol.com PHOTOS OF EAST BULKHEAD and 2-FT RAISED WALL ON WATER SIDE at 11831 E. SR-106, Union, WA 98592, Parcel#22230-21-90030 j 1ewA 4r #2 #3 A .f 1 #5 #6 #7 T' ? 1_itL NEW EAST BULKHEAD WALL 8 2 RAISED WALL Prepared by NET Engineering,PLLC,800 F Wshkah St.Aberdeen,WA 98520 (360)310-0270 cell.(360)289-0958 bus, SMorta@aol.com Prepared for:JASON HILLS June 2.2024 SHEET 1.0 IR5E_xw 'q.--W-" , '..3L` ..._,'.4 .R. ._- .. R:?: <. ,.,.� `,ti1-:a�:w. t.- ...a1dFS^ t: '•' ..9P-,e.. -^,""q"• ''4., ,.., { { - �;',3�,a• *�t a .y .,. .•;.+�wy:".. .. �,� ."�S•`*{y`'�Y _ _ f:'�" i y jy, .R �4yL{ -T�f v ,S i '�t+-','., rn. �?3Y3'' n...-:;ew.�l,y��.•I!`•f�!�^°�7F.'F 4. .r it wr'' r, ,1 !.,, } : 1 .S 7.. ;ii �L,y��"�T•-�"q�?i!a`R.4' .�'wr � 9.*�p.'6 _-..� �1�".. ' �. 9c� ; ,� 4F4 f: � . 4a!"asa• .1; �{�,�, ':[�' -4 ;q.- '� - i. � �'.1' fit, .. )I ,�� � �,R�N� +Y6+�7Fi" ��.t .A S4 '3 �'5• � L ., °3 ' � _' � - 4, — � � �. 5[Wua .. � �a`• f t. }} ! •; ..c vim' f i* "' -4.; k' _.'3y. .•0i:�w d:�: .i.- ...,.. ..: ';', k_ 4 _ «:,. ", "i: ^m. S, •".i[ - r 7�' f: 9-=s<:. '.+�a6ra•. - , ii" '''� Builders„ Please 0Remit FO BOX 35143 #1019 DATE INVOICE NO. . FirstSource SEATTLE WA 98124-5143 04-20-23 87143430 253-719-0516 INVOICE ***REPRINT*** **INVOICE** PG 1 0 872078 s 872078 L INTEGRATED NW CONST LLC H INTEGRATED NW CONST LLC OPO BOX 1008 P MISC ACCOUNT T T 60 N LAKE CUSGMAN RD STE 109 o HOODSPORT, WA 98548 o HOOESPORT, WA 98548 A35946024 t HERINAf T ER REFERRED TD AS CUSTOMER) JOB NO. COST.ORDER NO. COST CODE DATE SHIPPED SALES ORDER M TERMS MISCACCOUNT NK N10TH ORDERED SHIPPED Br0 ITEM NO DESCRIPTION UN UNIT PRICE EXTENSION 13 58REBAR60 5/8"X2C' REBAR #5 60G EA 21.19 275.47 N SHEL ON/MAS N/WA .80 WA23C1 SHELWAYD 275.47 .00 .00 002110W 275.47 TAX CODE SHIPPED FROM SALES AMOUNT SALES TAX SHIPPING CHARGE MISCELLANEOUS TOTAL TERMS&CONDITIONS u"be tounC at wvw bbf.comRe.ms P900297 SHELTON YARD HOUSE ACCOUNT DUE DATE 05-10-23 BUYER: ENT BY: Tina Bowers ***CPU*** iIlI lID 11111011101110111 1111101111111 VIII � T Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov BLD2023-00354 BULKHEAD OR DOCK- RESIDENTIAL PROJECT DESCRIPTION: RETAINING WALL INSTALLED BEHIND ISSUED: 04/24/2023 EXISTING FAILING WALL SITE ADDRESS: 11831 E STATE ROUTE 106 UNION EXPIRES: 10/2112023 PARCEL: 222302190030 APPLICANT: HILLS JASON ROBERT&KATEY CHRISTINE OWNER: HILLS JASON ROBERT&KATEY CHRISTINE 10814 NE 190TH PL 10814 NE 190TH PL BOTHELL,WA 98011 BOTHELL,WA 98011 1.206.963.0302 GENERAL CONTRACTOR'S LICENSE: INTERGRATED NW CONSTRUCTION LLC License: INTEGNC843J1 PO BOX 1008HOODSPORT,WA98548 Expires: 04/21/2024 253.888.5314 VALUATIONS: FEES: Paid Due Project Valuation (BID, 62000.00 $62,000.00 Planning Review Fee $240.00 $0.00 ESTIMATION..) Technology Surcharge $26.16 $0.00 State Fee-Residential $6.50 $0.00 Building Permit Fee $792.82 $0.00 Plan Check Fee $515.33 $0.00 Total: $62,000.00 Totals : $1,580.81 $0.00 REQUIRED INSPECTIONS Setback Inspection General Inspection Footing Inspection BLD-Final Inspection Foundation Wall-Pre-Pour Inspection CONDITIONS ' All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. Printed by:Genie Mcfariand on:04/24/2023 11:09 AM Page 1 of 3 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov BULKHEAD OR DOCK- RESIDENTIAL BLD2023-00354 * All other necessary permits from Mason County, Washington State and/or Federal Agencies that are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permitlapplication becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. Printed by:Genie Mcfarland on:04/24/2023 11:09 AM Page 2 of 3 4 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov BULKHEAD OR DOCK- RESIDENTIAL BLD2023-00354 * Review of wall only. * In addition to the inspections required in IBC, Section 110, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties& responsibilities shall be as specified in Chapter 17. Special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton WA98584 and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final occupancy inspections. *SPECIAL INSPECTION REQUIRED FOR PROPOSE EPDXIED DOWEL INTO EXISTING WALL. REPORTS MUST BE PROVIDED PRIOR TO CONCRETE PLACEMENT. * DRAIN PIPING MUST BE VERIFIED PRIOR TO COVER t hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. issued By: L, Contractor or Authorize gent: Date: Printed by:Genie Mcfarland on:04/24/2023 11:09 AM Page 3 of 3 r Special Inspection Requirements MA50A(Di3->TY C"OVWL'WTR 5EgVWFS BLD2023-00354 Hills-Retaining Wall Behind Bulkhead 11831 E SR 106,Union/22230-21-90030 Permit Number Project Title Project Address'Parcel Number Applicants of projects requiring Special Inspection or Testing per Chapter 1704 &1705 of the International Building Code,as amended by Washington State. Please acknowledge and return this form to the Mason County Permit Center. THESE INSPECTIONS ARE NOT PERFORMED BY THE BUILDING DEPARTMENT AND MUST BE PERFORMED BY QUALIFIED SPECIAL INSPECTORS, HIRED BY THE OWNER AND APPROVED BY THE COUNTY PERMIT CENTER. Individuals certified in a special inspection category by Washington Association of Building officials(WABO)or individuals employed by a recognized testing laboratory and under the direct supervision of a Registered Professional Engineer are typically considered qualified at the discretion of the local jurisdiction having authority for enforcement. BEFORE A PERMIT CAN BE ISSUED: The Owner or his/her representative, on the advice of the responsible Project Engineer or Architect, shall fill out completely. sign and submit two (2) copies of the attached"Structural Tests and Inspection Schedule"to this Department for review and approval including any requirements related to the Mason County Municipal Code. The Owner, General Contractor, and Inspection/Testing Agency, where applicable, shall also acknowledge the following conditions applicable to Special Inspection and/or Testing. 1. Inspection/Testing Agency shall submit names and qualifications of on-site Special Inspectors to the Building Inspection Permit Center for approval PRIOR TO PERMIT/S BEING ISSUED. 2. All Special Inspections shall be noted on the approved plans or attached approved documents. 3. All special inspections shall be approved by the County or as recommended by the Engineer of Record (EOR). 4. It is the responsibility of the General Contractor to review County approved plans for additional inspection or testing requirements that may be noted or required per IBC as noted on approved plans. 5. The General Contractor is responsible for proper notification to the Inspection/Testing Agency for items listed on this form. 6. Special Inspectors shall provide detailed reports on company letterhead to the Building Inspector of all required inspection activities. These may also be provided when the inspector visits the jobsite for the scheduled inspection but must be completed before the subject of inspection is approved by the building inspector. 7. Copies of all ongoing laboratory and testing reports shall be sent directly to the Building Inspector by the InspectioniTesting Agency or other responsible party within a reasonable time to test results. 8. BEFORE A CERTIFICATE OF OCCUPANCY APPROVAL CAN BE ISSUED: The Inspection/Testing Agency shall submit a F;NA. REPORT LETTER stating that all items requiring testing and inspection have been fulfilled and reported and a final inspection report shall be provided. A copy of the statement is to be maintained at the jobsite for the Building Inspectors review prior to final inspections. Page 1 of 4 ;SpecialInspection Requirements ACKNOWLEDGEMENTS Prior Co issuance of a building permit, the Owner, on the advice of the Project Engineer or Architect, shall complete.sign,and submit this form to the County Permit Center. Declaration of Owner 1.as the owner of the project,declare that the testing agency firm's or individual/s listed herein are hired by me to perform "Special Inspections" and/or"Structural Testing" in accordance with the provisions of the International Building code(IBC)Chapter 17. O Jason Hills � 4/20/2023 Owner(print) Owner(Signature) (date) Declaration of Registered Professional Architect/Engineer I, as the design professional in responsible charge of the project listed herein, declare that the special inspection listed herein are required for this project in accordance with the provisions of the International Building Code(IBC)Chapter 17. G/- /3-. 3 Steven P. Marta, P.E. Architect/Engineer(print) 1 Architect/Engineer Stamp/Signature(date) . ssjdlVALti�G Mona Engineering and Testing, PLLC Testing Agency Name/Contact j800 E. Wishkah St. info: lAberdeen, WA 98520, (360) 310-0270 e-mail: SMorta@aol.com The Special Inspection/Testing Agency listed above must have a current Portfolio of Qualifications on file with the County prior to performing work. Declaration of the General Contractor 1,as the General Contractor of the project_agree to comply with the"Contractor Responsibility" items noted herein. Caralyn Valdeman,General Manager �� t-�- Integrated NW Construction,LLC ► i 3 General Contractor(print) General Contractor rgnature (date) Page 2of4 Special Inspection Requirements Required Special Inspections International Building Code; Chapter 17: A completed and signed copy of pages 1 through 4 of this form shall be submitted to the "Permit Center" prior to building permit approval. Engineer shall check the applicable items: ❑ Special inspection of fabricated items 1704.2.5 D Submittals to the building official 1704.5 ❑Structures over 75' in height located in Seismic Design Category D. 1704.6.1 ❑ Structures classified as Risk Category 111 or IV located in Seismic Design Category D, 1704.6.1 ❑Steel construction &structural Steel 1705.2.1 ❑Cold form steel deck 1705.2.2 ❑Open-web steel joists&girders 1705.2.3 ❑Cold form steel trusses spanning 60 feet or greater 1705.2.4 " ..Concrete construction 1705.3 &Table 1705.3(t poxrF/ 4ut1 ) ❑ Shotcrete 1705.3 ❑Welding of reinforcing bars 1705.3.1 ❑Material Tests 1705.3.2 ❑Masonry Construction 1705.4 ❑Empirically designed masonry,glass unit&masonry in Risk Category IV 1705.4.1 ❑ Vertical masonry foundation elements 1705.4.2 ❑Wood construction 1705.5 ❑High Load Diaphragms 1705.5.1 ❑Metal-plate connected wood trusses spanning 60 feet or greater 1705.5.2 ❑Soils 1705.6 &Table 1705.6 ❑Driven deep foundations 1705.7&Table 1705.7 ❑Cast in-place deep foundations 1705.8&Table 1705.8 ❑Helical pile foundations 1705.9 ❑Fabricated items 1705.10 Page 3 of 4 Requirements Special Inspection C SRVCtS ❑Special inspections for wind resistance 1705.1.1. Q Structural wood 1705.11.1 ❑ Wind resisting components 1705.11.3 D Cold formed steel light frame 1705.11.2 ❑Special inspection for seismic resistance 1705.1.2 ❑Special inspection for structural steel per 1705.12.1 ❑Seismic force-resisting systems 1705.12.1.1 ❑Structural steel elements 1705.12.1.2 ❑Special.inspection for structural wood per 1705.12.2 O Special inspection for cold-formed steel per 1705.1 2.3 ❑Designated seismic systems 1705.12.4 ❑Architectural components 1705.12.5 ❑Plumbing,mechanical&electrical components 1705.12.6 ❑Storage racks 1705.12.7 ❑Seismic isolation systems 1705.12.8 ❑Cold-formed steel special bolted moment frames 1705.12.9 ❑Testing for seismic resistance 1705.13 ❑Structural steel 1705.13.1 ❑Seismic fore-resisting systems 1705.13.1.1 ❑Structural steel elements 1705.13.1.2 ❑Nonstructural components 1705.13.2 ❑ Designated seismic systems 1705.13.3 ❑ Seismic isolation systems 1705.1 3.4 ❑ Sprayed fire-resistance materials 1705.14 ❑Physical and visual tests 1705.14.1 ❑Structural member surface conditions 1705.14.2(1705.14.3 through 1705.14-6.3) o Mastic&intumescent fire-resistance costings 1705.15 ❑Exterior insulation&finish systems(EIFS) 1705.16 ❑Fire-resistance penetrations and joints 1705.17 ❑Penetration firestops'1705.17.1 ❑ Fire-resistant joint systems 1705.17.2 ❑Testing for smoke control 1705.18 ❑ Testing Scope 1705.18.1 Page 4 of 4