FIR2025-00039 - FIR Inspections - 4/7/2026
Mason County Fire Marshal 615 W. Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 Fire Alarm Certification/Final Test FIR: 2Z -o ? ' Location: / k9M;/dz lc- r.- Contractor: ,sr Phone #: oV /Z4i ` Contact: Air., /L1,/�G Test Date: 9/74( CHECKLIST 1 Verify panel is in "Normal" condition and clear of any signals L Kill power at main panel & verify dedicated circuit, clearly marked & lockout tab L A/C Power trouble showing? ✓ Activate device(s), verify it activates the alarm and shows correctly on the panel Walk the building while in alarm under battery load. Check for all stobes/sounds for sync '/ Silence Alarm ✓ Activate a few other devices in different areas to verify alarm reactivates after being silenced ✓ Reset Alarm L Does panel still show trouble (due to AC power)? V Disconnect Signal Loop Circuit (SLC) to create/verify a trouble for each device on circuit .1 Reconnect SLC. System should reset& only AC trouble showing Disconnect the communicate n line &verify communication trouble V Batteries on plans 4,7/A ,"Y/1?; match batteries in system 2 f wf////'? V FACP Sign on Door(s) leading to panel location? Notification Device Time Comments Smoke detector at FACP Waterflow Inspector's Test Tamper Switch Manual pull at r OZ Manual pull at Manual pull at lea D Heat Detector p D Heat Detector 911 Heat Detector Heat Detector g, Heat Detector v r Smoke Detector Smoke Detector 31'7t7_ u y1 c x Smoke Detector Punch List/Comments: Passed Final Test? Yes No _ Gamevu�ell 302 Series FIRE CONTROL INSTRUMENTS by Honeywell Description Rate-Compensation The Thermotech 302 Series Rate Compensation Heat Heat Detector Detectors are normally-open devices designed especially for fire detection and alarm systems. The 302 Series oper- ates within a controlled range of two to three degrees of their set points, regardless of the speed or rate of tempera- ture rise. These detectors are available in either 135° F or 194° F ratings. Principles of Operation The 302 Series rate-compensation heat detectors respond and activate the fire alarm immediately whenever the ambient temperature reaches the preset temperature set- ting. Under rapid heat rise conditions, the rate-compensa- tion feature enables the detector to respond one to three degrees ahead of the setting.At the same time,however, it does not respond to momentary temperature fluctuations Features below the selected protection level, thus eliminating false alarms. When temperature drops back down below the Initiates an immediate response.The 302 Series acti- protection level,the detector automatically resets itself. votes whenever ambient air temperature reaches a Application Information detector's setting, eliminating the thermal time lag inher- ent in conventional heat detectors The 302 Series detectors have a smooth-ceiling UL rating of 50' x 50' (15.24 x 15.24 meters) and they are the only Eliminates false alarms.The 302 Series do not respond type of heat detectors having such a rating on both fixed to momentary temperature fluctuations below the temperature and rate compensation. selected temperature Specifications • Supports universal application.The 302 Series can be used in all areas for any type of occupancy Dimensions: Total overall length: 4-1/8" Base diameter: 2" Self-restoring Electrical Ratings: Built with a hermetically sealed, shock resistant corro- Voltage: Current: sion resistant, and tamper-proof 6-125 VAC 5 amps 6-25 VDC 1 amp 125 VDC 0.5 amp SIGNALING LISTED APPROVED S539 7300-1703:0131 E35018A IS® GAMEWELL-FCI IIC■�;' . 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 -Fax:(203)484-7118 1111111 i111-S Specifications are for information only,are not intended for installation purposes and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved www.gamewell-fci.com CS-2519 Rev.B page 1 of 2 Product Line Information Part Number Description 302-135: 135°F Interior Vertical Mounting, FM and UL(See Note 1). 302-194: 194°F Interior Vertical Mounting, FM and UL(See Note 1). 302-AW-135: 135°F All-Weather Vertical Mounting, FM and UL(See Note 2). 302-AW-194: 194°F All-Weather Vertical Mounting, FM and UL(See Note 2). 302-ET-135: 135°F All-Weather Vertical Mounting, FM and UL(See Note 3). 302-ET-194: 194°F All-Weather Vertical Mounting, FM and UL(See Note 3). 302-EPM-135: 135°F Explosion-Proof Mounting, UL(See Note 4). 302-EPM-194: 194°F Explosion Proof Mounting, UL(See Note 4). AP-P: Decorative white plastic adaptor plate for mounting 302 and 302-AM to 4"outlet box. NOTES: Note 1: For interior mounting in any atmosphere that is compatible with terminal screw type connections. UL rating 50'x 50' (15.24 x 15.24 meters). Note 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather lead are properly spliced to'THW'or equivalent type wire. Note 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagons wrench grip bushing with 1/2"(1.27 cm)conduit threads for attachment to threaded hub cover, or any special outlet box. Note 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench grip bushing with 1/2" (1.27 cm) condui threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co.,or equal. CUT AWAY VIEW FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPENSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT COMPENSATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Figure 1 Thermotech 302 Series �GAEWELL-FCI2 Clintonville Roa�N.rthford, 64720 USA•Tel:(203)484-7161 •Fax:(203)484-7118CS 2519Rev.B page2 of 2 well-fci.com SYSTEM �$ SENSOR® L-Series and L-Series with LED Indoor Selectable E E Horns, Strobes and Horn Strobes System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits n with lower current draw and modern aesthetics. Features The System Sensor L-Series and L-Series with LED • LED technology provides lower current draw platform offers the most versatile and easy-to-use line of horns, • Digital Voltage Meter(DVM)diagnostic test points for Horn strobes,and horn strobes in the industry with lower current draw and Strobes and Strobes modern aesthetics.LED lighting technology offers significantly lower • Common aesthetics across the L-Series platform current draw compared to older Xenon bulbs across a full candela • Standard and compact sizes range.This improves design flexibility for notification appliance • Tamper-resistant construction circuits(NACs)while also reducing power supply requirements • Field-selectable candela settings on wall units: 15,30,75,95, allowing for simpler and lower cost installations. 110, 135,and 185 Flexible design options meet virtually any application requirement: • Field-selectable candela settings on ceiling units: 15,30,75,95, wall or ceiling mount,standard or compact sizes,red or white color 115, 150,and 177 choices,bezel kits for alternate markings and languages,and LED • Rotary switches for candela,tone and volume selections color lenses for distinctive visual signaling. In addition,installers can • Mounting plate provides plug-in design for easier installation and easily adapt devices using field selectable candela,tone and volume shorting springs to check wiring continuity settings using rotary switches. • Electrically compatible with legacy SpectrAlert,SpectrAlert Advance and L-series devices The L-Series and L-Series with LED line is developed to simplify Synchronization through use of UL approved power supplies that installation.All devices feature plug-in designs with minimal intrusion • support System Sensor Sync protocol or System Sensor MDL3 into the back box,making installations fast and foolproof while Sync Module virtually eliminating costly and time-consuming ground faults.The • universal mounting plate includes an onboard shorting spring,so Horns,Strobes and Horn Strobes listed for wall or ceiling use installers can test wiring continuity before the device is installed. In addition,the System Sensor L-Series with LED notification Agency Listings appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter(DVM)without SIGNALING SIGNALING removing the appliance from the wall or ceiling.The DVM test points cOU F M ® are discreetly located on the face of the notification appliance which t,s u� UDC .�:. LISTED LISTED LISTED APPROVED enable faster troubleshooting and end of line(EOL)voltage checks Horns. Horns. 3057072 7360.1e3D52s while greatly reducing the risk of misplacing or damaging appliances 04013 04011 FM23FPUS0195 7135-1653.0504 7135-16530526 during troubleshooting. AVDS916-01•10/03/20213•Page 1 L-Series and L-Series with LED Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage,LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage,Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range,LED Strobes and Horn Strobes 16 to 33 V(24 V nominal) Operating Voltage Range,Horns 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG UL/ULC Current Draw Data, Horn Tones,and Sound Output Data Candela 16-33 Volts 8-17.5 Volts 16-33 Volts Rating Wall Ceiling Sound Pattern dB DC DC FWR Candela 15 18 18 Temporal High 39 44 54 Range 30 22 22 Temporal Low 28 32 54 75 70 70 Non-Temporal High 43 47 54 75 75 Non-Temporal Low 29 32 54 110 85 — 3.1 KHz Temporal High 39 41 54 115 — 90 3.1 KHz Temporal Low 29 32 54 135 105 — 3.1 KHz Non-Temporal High 42 43 54 150 - 110 3.1 KHz Non-Temporal Low 28 29 54 177 115 Coded High 43 47 54 185 12U — 3.1 KHz Coded High 42 43 54 • .: Current Draw(mA RMS),Horn Strobe, Sound Candela Range(15-185 cd) Output (d BA) 16-33 Volts 16-33V Switch Volume 15cd 30cd 75cd -25cd 110cd 115cd 135cd 150cd 177cd 185cd DC Pos. Sound Pattern Setting WALL CEILING WALL CEILING CEILING WALL 1 Temporal3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 Ii U1 UI UU 115 155 155 165 165 86 6 3.1 KHz Temporal 3 Low 35 38 87 89 yln 115 128 130 135 135 80 7 3.1KHz Non-Temporal High 40 42 87 89 9 115 125 125 135 135 86 8 3.1 KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80 AVD$916-01•10/03/2023•Page 2