HomeMy WebLinkAboutAFTER THE FACT AS-BUILT - SWG As-Built Acme Septic Design and Maintenance P 0 Box 2954 380-898.8488 Silverdale,WA 98383 Fax;call first PROPERTY INFORMATION Location:51 NE SCHOONER PL Belfair Tax ID:123305200021 Man To: JUAN CRUZ PEDRO MATEO P O BOX 1272 Use: BELFAIR,WA 98528 • GENERAL SYSTEM TYPE:Conventional (Non-Pressurized) ON ID:123305200021 County Area: Hood Canal Fold a ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold Here Here inspected:01/08/2026 - Inspection Type:ROUTINE - Correction Status:No corrections needed Company: Work Performed By: Submitted 01/08/2026 by: Acme Septic Design and Maintenance Rod Left Mindy Loux COMMENTS&GENERAL INSPECTION NOTES No Deficiencies Noted The homeowner was not home at the time of the site visit.The system was completely inspected.No ponding was observed.Scum&sludge are within operational limits;pumping is not needed at this time.The system Is In good working order and functioning as designed. GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected Components accessible for service: YES All required service performed(if no-specify omitted inspection items in notes): YES Surfacing effluent from any component(Including mound seepage): NO Components appear to be watertight-no visual leaks: YES Improper encroachment(structuresfimpervious surfaces) ' NO All riser lids securely fastened upon departure:' N/A Electrical repairs needed. If YES describe in comments: N/A Inspected components appear to be in good physical condition: YES Root intrusion on any components. If YES describe In comments: NO Settling problems observed. If YES describe In comments: NO The house/structure was vacant or used infrequently,assessment of the drainfieid was not possible. NO ONSITE SEWAGE SYSTEM INSPECTION DETAIL Distribution:D-Box This component was: Fully Inspected D-Box in good condition: YES D-Box outlets set to allow e•ual effluent distribution: YES TANK:Septic Tank-2 Compartment This component was: Fully Inspected Effluent level within operational limits(if NO explain in comments): YES All required baffles in place(N/A=No baffles required): YES Compartment 1 Scum accumulation(Inches,if other specify): 3 Compartment 1 Sludge accumulation(Inches,if other specify): 8 Compartment 2 Scum accumulation(Inches,if other specify): o Compartment 2 Sludge accumulation(Inches,if other specify): 2 Purr'-I •recommended: NO •rainfield(disposal):Gravity This component was: Fully Inspected Component appears to be functioning as intended: YES Ponding present?If YES explain in comments: NO Drainfleld was vacuumed,flushed or hydro-jetted?(If YES,explain in comments) NO • This report Indicates certain chamcterisiles or the ensile sewage system et the time of visit.in no way Is Misreport a guarantee'generation erratum performance. ReportiD:1482879 View inspection reports online at www.onlinerme.com Page 1 of 1 PROPERTY OWNER NOTE: Carefully review ALL aspects of this septic design.ANY costs incurred due to changes to this design after submission to the County Health Department are the sole responsibility of the property owner. NOTE: PRESCRIPTIVE FLOW CONTROL MEASURES ARE TO BE DESIGNED BY LICENSED INDIVIDUALS IAW WITH APPLICABLE STATE AND COUNTY CODES. 110.12' D • sa p 42' `- A N -/ SL3 pr 100% 255 _ 5'_ _ i % RESERVE zit ' 15' �o / £ l_. itlig O W ♦ 0 235' t , rr ' •,� • , O 240' t� A , DESIGNER N a! ' N 2. O\ EXPIRES 1211516 VT m j \ e N • ,....‘0. ..o /,� ��• 'X TIN' • p- 'INFI' a III i OW R POLE I SOIL LOG#3: 250' �� ♦ - - S o SOIL TYPE: 3 V 0"-15": REDDISH BROWN MEDIUM SAND • ®." EwAY 67.85' 15"-48": GRAY MEDIUM SAND - , SOIL LOG#4: • • . --• . o. • -: e '. - 245� . . -• - . SOIL TYPE: 3 �. 0"-24": REDDISH BROWN MEDIUM SAND �_�a -• • 24"-48": GRAY MEDIUM SAND a: . • < . o - ' . •: :NE. SCIOON� R: P<L 0' 5'10' 20' 30' 50' • • • . o WATER LINE DISCLAIMER: • . : `" o IF WATER UNE RESIDES WITHIN PROPOSED DRAINFIELDS ANDIOR < - . . - . . _ %,!-I-1 - NEEDS TOBE RELOCATED FOR ANY REASON HOMEOWNER - - o • - . . d - - - CONSUMES ALL FINANCIAL RESPONSIBILITY - - - o BEEN DEMONSTRATED BY THE OWNERS) ANO/OR THEIR EN 71 a a : SCALE (FEET) - INSTALLER ivsus-r VERIFY THAT WATER LINE LOCATION AT TIME OF INSTALL MEETS ALL COCES/SETBACKS - . . -IT IS THE RESPONSIBILITY OF OWNER/REPRESENTING AGENT TO PROVIDE TO ACME IN WRITING ANY ANC ALL INFORMATION PERTINENT TO THE DEVELOPMENT OF SEPTIC FEASIBILITY AN0/OR LEGEND DESIGN C7 E S I G NJ IN C LU O I N G ALL GRAY/BLACK WATER STUB OUTS, UTILITY LOCATIONS. PRO P EIRTY MIME NI SIGNS GI M E N S I O Ni S. EASEMENTS. BUFFERS AN SETBACKS RE C)U I REO BY GOVERNING OR REGUATNENTITIES ,LIG - DRY WEATHER INSTALLATION AND SITE PREP R EQU IR EC. =SOIL LOG -PROTECT PRIMARY AND RESERVE O RAIN FIELD AREAS FROM ANY VEHICLE TRAFFIC. -- = NO BUILD ZONE - I -NiO FOUNDATION SPOILS OR BURNING ON ORAINFIELC AREAS. =1. =CLEARING LIMITS 7 JANUARY 2026 -DUE T O UNFORESEEN WAT R TABLE S, A CURTAIN GRAIN MAY BE R U MO I RE O. / DATE- P.O.-DEF.EIVDINCG UPON FINAL ELEVATIONS, A PUMP MAY BE KBOUIREO. t V1 =LOW AREAS P BOX 2954 -DIRECT ALL DOWNSPOUT/SURFACE WATER AWAY FROM GRAINFIELD AREAS. =TREES 12" CIA MIGUEL F GF LATERALS OR MODULES ARE DEPICTED, THEY ARE APPROXIMATE ANC MAY VARY. NAME- SILVERDALE, WA. - I P ROVI1EO THEY REMAIN IN THE D ELIN EATEC OF AREA. 1� --ALL W LL WITHN T O UIV HAV BEEN H WN 0' ' ES I 100 FEET PROP. BO0ARIES E SO (200' FOR CLASS-B WAIVER). 98383 -EXCEPT FOR THE DISPERSAL COMPONENT, ALL SEPTIC COMPONENTS MUST BE WATERTIGHT TO SUR _FACE. 0 - CLEAN OUT TAX ID- 12330-52-00021 -WATER LINE MUST BE A MINIMUM OF 10' FROM ANY SEPTIC COMPONENT. - MAINTAIN A MINIMUM 50' SETBACK GOWN SLO PE OF I-PITS- MINIMUM OF 10' SETBACK U PS LO PE OF I-PITS. 0 = EXISTING SEPTIC TANK STREET- 51 NE SCHOONER PL II. -SEED AN C) M U H N D NJ LC RMM LC FINIAL RAIPIE COVE IEDIATEL U P N M T Y O COPLEION TEL. r EL 360-698-8488 - DEPENDING ON THE TYPE OF ATU USED, A TRASH TRAP MAY BE REQUIRED. = EXISTING D-BOX 11. 1 - LATERALS MAY BE NO CLOSER THAN 5' ON CENTER. SCALE. 1"=20' SITE PLAN INFO@ACMESEPTIC,COM - IF WATER ANC SEWER LINES CROSS, THEY MUST BE CO NSTR UCTEC IAW STATE 8, COUNTY COC E.