HomeMy WebLinkAboutSWG2025-00458 - SWG Application / Design - 12/16/2025 MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 400 ir BELFAIR:360-275-4467,EXT 400 � Public Health & Human Services ELMA:360-482-5269,EXT 400 . am , FAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2025-00458 OWNER SOBERANIS ET VIR VANESSA Phone: KRISTINE Address: RYAN LEWIS EDBERG SHELTON, WA 98584 APPLICANT SOBERANIS ET VIR VANESSA Phone: KRISTINE Address: RYAN LEWIS EDBERG SHELTON, WA 98584 SEPTIC INSTALLER SHANE MAPLES* Phone: 360-463-8474 Address: 911 SE Arcadia Road SHELTON, WA 98584 SEPTIC DESIGNER PAULA JOHNSON* Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 Site Address: 1250 E CRESTVIEW DR Primary Parcel Number: 320154390020 New 2 comp. septic tank with pump in second comp. to serve as lift Permit Description: station Permit Submitted Date: 12/03/2025 Permit Issued Date: 12/16/2025 Issued By: Rhonda Thompson Current Permit Fees Paid: $270.00 (additional fees may be required upon installation of system). Permit Expiration Date: 12/1612028 (based on date of inspection) 0 Type of Work OSS New Construction Components being Replaced: Septic Tank Only Surfacing Sewage? No Existing Failure? No Shoreline? No Horizontal Setbacks Met? Yes Number of Bedrooms: 3 Drinking Water Source: Private Well/Spring Additional Details: New 2 comp. septic tank with pump in 2nd comp. Permit Conditions: 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 5 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.govlhealth/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY DATE RECEVED: I j� ,` 20a.. N D ., MASON COUNTY u I ✓ N '`'' COMMUNITY SERVICES AMOUNT RECEN D: RECEIVED BY: - �-�(� ��tcP oar Public Health(Community HcaRh Environmental Health) (A 360.427.967C.cat.000 or 36G 175«67.exl.4v1L /.�� ��J��/�(�r O -- 415 N.Ltf.Street-Snetron,WA 9255, SWG �0a / r`� 1J Z (n ON-SITE SEWAGE TANK ONLY APPLICATION D D g m n APPLICANT I PI-:On9 m Ryan Edberg I (818) 324-8706 [[�I�n zc MAILING ADDRESS-STREET.CITY.STATE.ZIP CODE \�/ '''---;:7 CO 1250 E Crestview Dr, Shelton, WA 98584 �0 �v m SITE ADDRESS-STREET.CITY,ZIP CODE L / \�/ O co same jJ 1 NAME OF DESIGNERFI-C E L�L/J O N Arrow Septic Designs (360)898-2255 PHCr.E a I O Maples Excavating (360)463-8474 Q4 < TYPE OF WOK,select oaf)) DRINKING WATER SOURCE O ® NEW CONSTRUCTION/UPGRADES 0 REPAIR/REPLACEMENT ❑O PRIVATE INDIVIDUAL WELL 0 PRIVATE TWO-PARTY WELL Z COMPONENT(S)TO BE REPLACED/INSTALLED 0 PUBLIC WATER SYSTEM I ® SEPTIC TANK 0 PUMP TANK 0 RV HOLDING TANK BEDROOMS LOT SIZE I RI OTHER OTHER lift pump in 2-compartment tank at new house 3 BR 16.77 acres OTHER DETAILS(select all(ha,apply,) TANK(S)SETBACK CHECKLIST 0 ❑ SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINE E 100FT+PUBLIC/COMMUNITY WELLS n 1 SUBMITTALS 0 50FT+PRIVATE WELLS.SURFACE WATERS.STREAMS.RIVERS ® PLOT PLAN(REQUIRED) M TANK CROSS SECTION(REQUIRED) 0 10FT+DRINKING WATER SUPPLY LINES O ® PUMP DETAILS(IF APPLICABLE) 0 WAIVER(S)(IF APPLICABLE) 1 SFT+PROPERTY/EASEMENT LINES,FOUNDATIONS.FOOTINGS PLOT PLAN CHECKLIST 0 IO ® PROPERTY LINES AND EASEMENTS ® EXISTING/PROPOSED STRUCTURES Si EXISTING/PROPOSED OSS COMPONENTS AND LINES —I ® WELLS WITHIN 100FT ® WATER SUPPLY LINES ® DRIVEWAYS/PARKING Iii SURFACE WATERS,STREAMS.RIVERS.ETC... I N ® DIRECTION OF SLOPE/CONTOURS ® PERIMETER/CURTAIN DRAINS ® NORTH ARROW ®SCALE BAR O DIRECTIONS TO SITE AND SITE CONDITIONS:tea locked pale) Go out Hwy 3 and turn (R) onto E Agate Rd. Turn (R) onto E Crestview Dr. Turn (R) onto gravel driveway just before "1250" mailbox. *Note: If site visit is needed, please arrange with owner because of gate and free range birds.* — OFFICIAL USE ONLY BELOW THIS LINE UPGRADE!FAILURE SOURCE(for reporting purposes) �,/ ❑VOLUNTARY 0 MAINTENANCE/PUMPING >76UILDING PERMIT CI HOME SALE ['COMPLAINT ['OTHER: COMMENTS/CONDITIONS 4Pla- 2-Uirlf • VLeTC-- -fa A (14// f"p .z-K0( curq • SEWAGE TANKS MUST BE LISTED UNDER DOH'LIST OF REGISTERED SEWAGE TANKS' TANKS MUST MEET CURRENT MINIMUM SIZE REQUIREMENTS.EQUIPPED WITH RISERS AND LIDS TO SURFACE.AND INCLUDE AN EFFLUENT FILTER(IF APPLICABLE). RECORD DRAWING AND INSTALLATION REPORT REQUIRED FOR FINAL APPROVAL. INSPECTOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATION APPROVED!ISSUED BY DATE -- 74 I L I rb---keiwticovi ( Lit(a1zc THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVISED?,92C15 Arrow Septic Designs 171 E. Vuecrest Dr. Union,WA 98592 November 6,2025 Mason County Department of Health Services 415 N 6th St Shelton,WA 98584 RE: Ryan Edberg Property(Parcel#32015-43-90020)tank permit& prove reserve drainfield Dear Inspector: Attached is a septic tank permit for a property located at 1250 E Crestview Dr., Shelton,WA 98584. The existing septic system has no original septic records. The site has a 1,200-gallon 2-compartment septic tank followed by a d-box with speed levelers and approx. 120 LF of drainfield trenches. Based on legacy sizing standards of 120 s.f. per bedroom with a total of 360 s.f. this calculates to a 3-bedroom drainfield. The property has plenty of potential reserve drainfield area. The existing septic system has been recently inspected. The pumper did a 20-minute flow test on the drainfield and it accepted all water and is working as intended. An effluent filter has been added at the tank outlet. The existing septic served a house that burned down before the current owners purchased the property. The owners are planning to build a new 3-bedroom house in a different location from the old house so it will require a lift pump. Proposed is a new 1,200-gallon 2-compartment septic tank with a pump in the second compartment to send the sewage to the inlet of the existing septic tank. This lift pump will be on- demand and will need a high-level alert. All septic components are over 100' from the existing well. The property owner's contact information is as follows: Ryan Edberg 1250 E Crestview Dr Shelton, WA 98584 Phone: (818) 324-8706 If you need furthe formation, please contact my office at(360) 898-2255. i Sincerely, yam- ` ' 7 • I` spa 025 5100249 ' EC 1 6 2 H 6,.:1:0,... J PAULA JOY JOHNSON •�, OOUNT{EtiV1ROh � seprippiONLE`EXP1RifMpSON R�� baTi'g r." t Paula J. Johnson Licensed Onsite Wastewater Treatment System Designer n S� S p Cfl v�-� �'S Nth cam-e 'Prof' Ni 4, i/i �Z A i' Caiv+AVG1•iY,— �Aillik Ly / 2,vuxe- \� too' ` P`Pc's es,<-4 "^'� / ci-ov.IA-S-ce-e 4.\ 4 .,© N cb- . -7---- 4, ags4-.06-9, • Key: -3"\ 02 0 Cleanout .9 1,200 Gallon Septic Tank CO 02 \. 2-Compartment 0:-JAAEffluent Filter ( D-Box with speed-levelers \ \ and cover to surface ��>, ® AFrRDX. cLp t1-ot9sE Lbcttna,J A.,,, . .fr, 5 aftk. 4e...,K_ v./1.4-AA .toi..44,40 PPROVED �� Q. . P. 1:0' r.Sv ���try �N •A=y` � j. 3 DEC 16 2025 ©���� ', • dir la$ ..r 1rF ��ON COUNTY ENVIRONMENTAL HEALTH �3) 3 Xsa �_ s,o, .,9. > RET "PAULA JOY JOH .SON ...liowatip EY. ar,' 4 i (.,iA..-Zs 2 I 0 1 1 . AIN ' b o qo do ID 30 Q=i�5T 1{BCe v� �>_oT PLAN *• 1: o—i 5 s' L eR-P`1<n SAtz V e D3 E g.G -t- Pt\)y RRCo-rs) 15- 34 ?ARC L 32olS-45'9ODZ-o Loft-t-:: .5ANDiD�r-iP #�2: D-2 4 LS-��T5 J 24-4z,� 125o L2 S-t-JtEu- Dz D LS,-pptM ��T-o N� w 9gse 4. # 3: D --3 h' G g LS->-{.orris It 4: D-33"& LS-I- Ra aT3 . , N NQ1 a ... y >- -1 1 .- g i74`g- i to1 ` � Q -, gii ' tit" ''— R 'ai QSi E' .-- S • 2W �?� O R Cs� 4r, I% CZ >- a tc c gg n C ,z -4 v-: ep�,°� ()O Lr IY a tY 23 , oat <p' • �..• U giy$ _. , G Li ���" "" >O _ }� S Q r Z ;2u <i� t . , � $ & '__J c and U `nF`t'al D+ m'.�6 -_�1�tt p O C�} n``:\1 i l'i� iP 53s-, AA .it it Err.) Tt kyZq ` oY ' %Z i t'ia %• n v)5 3.� �� Q ��V Yo bgfS °r5g § 1 z 4 Wa as - z - $ m 8 w Cw -- a < -Ii x45o alai 1 • }�s3 ...<J U..: $Iri I.`.SG�ifW <S O 4 < <„�.< U WW ¢¢ G*1 N<_A APPROVED R-Ra 'SYe"fi,carn�caT Y +1 i- 1. MASON COUNTY ENV1RON.Y TAL HEALTH It!: 1-. ii I Y REIN L gaton 88 x—x—x c. Ii x—x—x—ti--4® vto , • 1s— .s „ , ,, K Y lV . . I • L • � • r( _ i i Nti 1" 1 \^ 1 a9s7® •\� e! i�` ill 1 1 1 . • is -F / '�li ! 1 b / ♦ �, -tom" • -K� i h 1I 11 K70t 3.fYiDGWF .I.8 t 1 1 i fi �, 11 1l ei 1 aR ' V-- �i-..ma+ x—x�'r 'IV'Y- r.�-.—._• Y N NrCI4' A KIEL I to 1 I a[XI 7.PAK.CCM tr li 8 1 k i! . ! 1 ,r i sli] 1eza�- `.. ,_,. ��nni 8 F u ar,r i+t`t.lxur T? . — — — — 1^ - a 9 I;. 0 6 o `EI > E,s , &$z0 SIGN r a i 4 ' °� ym C r n e '� } c� oaQtiEY ec4C z 'at 6 c. U.c I a . � , a - t tO3rtM .- :vi $ c� idw -'s"r _--- - i W o'` <a: . . C"jg mm . x b ` , oa y� L hvl Q bm m • pY 2 ` a�JUt� cC3 V 8� oan`� o g& • , 1 2- e , ( = •• a 4.W 1.-'.. g, w^ c� ;y-cgci-e " os41 ,•i✓ 0 • o a. a ■ A ® -� � 1 yaNc Uro ' s Y -act $mob j, vo02 Lr,NL,I2 2Lga,.$off 05$a• ✓ ✓ - bl 1 gd -£ -ion t n_o s 8/#d v � II�n■n.� �>,1 .�.► :, w"1 S N t W4 4"ILiN/S .i✓, 2-Com artment Se tic Tank with Solids Pum in Second Chamber j\Yel\k3 \-'a, --- cas- '''PrQfo , 4-' 1A - SECURED LID WITH GAS TIGHT SEAL 24'DIAMETER A+CClii R3'iER 1 -- (NUDEFINISH --- - -ins ----7 . ---11 ____ . FLOATING MAT - •-Nil crix...r\`-NQ-A^- -40 nf -0 I . 1 1 SEDDIENTS I • .74 ------,:\I , .. .- sienciam APPROVED DEC 16 2025 MASON COUNTY ENVIRONMENTAL HEALTH RET SECTION: 2.30.015 Your Peace of Mind is Our Top Priority , PELLI! FM1495 0 J 0214 Product information presented Supersedes here reflects conditions at time PUM p COMPANY 0511 of publication.Consult factory regarding discrepancies or Zoeller Family of Water Solutions inconsistencies. MAIL TO: P.O. BOX 16347•Louisville,KY 40256-0347 visit our web site: SHIP TO: 3649 Cane Run Road •Louisville.KY 40211-1961 www.zoeller.com (502)778-2731•1(800)928-PUMP•FAX(502)774-3624 COMPARE THESE FEATURES 264 SERIES • Non-clogging vortex impeller design • Float operated,2-pole switch ''' AS1 E-m AT E" • Durable cast iron construction. Cast iron switch cap, motor, and pump housing. (For Pump Prefix Identification see News & Views 0052) SUBMERSIBLE • Engineered plastic base SEINAGEIEFFLUENT* �' '�_ • Stainless steel screws, bolts, handle, guard, arm and seal14)assembly OR DEWATERING PUMP o 2" NPT DISCHARGE a„,..- • Engineered,glass-filled,plastic impeller with metal insert s CSA b +06 • UL listed 3-wire cord and plug. 15 ft. cord standard for uI POWDE:. • S automatic&nonautomatic �® COATED TOUGH'" • Corrosion-resistant powder coated epoxy finish C US • Motor-.4 HP 115V&230V, 1 Ph,60 Hz, 1725 RPM,oil filled . PSC motor, hermetically sealed, automatic reset thermal overload protection `— , ry • Upper and lower sleeve bearings running in bath of oil - , ' • Carbon and ceramic shaft seal e • Passes 2"spherical solids, • 2"NPT Discharge .1, • On point-12-112" • Off point-4-1/2" Note: The sizing of effluent systems normally requires variable level float(s)controls and properly sized basins to achieve -: required pumping cycles or dosing timers with • >_; nonautomatic pumps. . i• SIMPLEX AND DUPLEX - SYSTEMS AVAILABLE . U-0— `- - 5�— APPROVED No-,CW\. MODELS AVAILABLE • Automatic DEC 16 2025 • Nonautomatic(for variable level systems) • BE&BN264 available packaged witAMASON COUNTY ENVIRONMENTAL HEALTH Piggyback variable level float switch. R FT •May be used in those states where codes do not restrict sdids size in effluent systems. ©Copyright 2014 Zoeller Co.All rights reserved. CC ,t•y1c' 621,&i' w w w TOTAL DYNAMIC HEADIFLCW ---';'22 m) �`(212 ar) LL PUMP PERFORMANCE CURVE SEWAGE DE'NATEWNG I 6613132' MODEL 264 (16.3c! I(iF MODEL I 264 Q- V a 131 6 20 1 ' ! (12.2 cm) O Feet Meters Gallons Liters q. )Y '� - mil i 5 1.5 90 341v e'" `A 15 l',.•• 10 3.0 60 227 6 35+6a' 4— �a r 06.6cm; z 15 4.6 23 87 ''k-'/ 0 10 oos°3 ._--- Shut-off Head: I 18 ft(5.5 m) o 2- 0 I APPROVED i. 20 40 60 80 100 DEC 1 6 2025 IC 31 3la ,,r GALLONS (37.ecm) J ;�-.- r UTERS 0 160 323 Ll �.�``1 2''\ 61:2 MASON COUNTY ENVIRONMENTAL HEALTH , _I `3C_ I 16.5cm) FLOW PER MINUTE RET -'—.. i;: �' t i' 1 SK1543 CONSULT FACTORY FOR SPECIAL APPLICATIONS • Electrical alternators for duplex systems available with variable level float switches • For''M"and D"models,the approximate gallons pumped • Minimum recommended basin size out per cycle are: Simplex-18"x30" Tank Diameter Gallons Pumped Duplex-30"x36" 18"Simplex 8 Gallons • Standard Automatic-Weight 35.5 Ibs..4 HP 24"Simplex 15 Gallons • High water alarms available 30"Duplex 22 Gallons • Mechanical alternators available for duplex systems 36"Duplex 33 Gallons ocAumoN Maximum temperature of sewage or dewatering must be limited to 48"Duplex 60 Gallons 130°F(54°C). For over 130°F(54°C)special quotation required. 264 MODELS CONTROL SELECTION Model Volts Ph Mode Amps Simplex Duplex M264 115 1 Auto 9.4 1 4 N264 116 1 Non 9.4 2 or 3 4 D264 230 1 Auto 4.7 1 4 E264 230 1 Non 4.7 2 or 3 4 SELECTION GUIDE 1. Integral float operated mechanical switch, no external control required. 2. For automatic use single piggyback variable level float switch or double piggyback variable level float switch. Refer to F M 0477. 3. See FM1228 for correct model of simplex control panel. 4. See FM0712 for correct model of duplex control panel or FM1663 for a residential alternator system. Ica CAUTION I For Unw.mwa,or.aa°wra zoaterprxvow refer co catalog on risgyo a:xvanade Lava FloatSwitcne s.FM0477: All installation of controls,protection devices and wiring should be done by a qualified Electrical Alemator.FM0486;Mechanical Al:ematcr.FM0495.Sump!Sewase 5as ns,FM0487 and Singe Phase licensed electrician.All electrical and safety codes should be followed including the most Simplex Pump Control,FM1596.Alanr System,FM0732. recent National Electric Code(NEC)and the Occupational Safety and Health Act(OSHA). RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. / 4 Zar.ZZER MAIL TO: P.O.BOX 16347•Louisville,KY 40256-0347 SHIP TO: 3649 Cane Run Road•Louisville,KY 40211-1961 u (502)778-2731•1(8001 928-PUMP•FAX(502)774-3624 visit our web site: www.zoeller.com PUMP COMPANY Your Peace of Mind is Our Top Priority,' 1 ©Copyright 2014 Zoeller Co.All rights reserved. I Clive w Septic De igvs, Jac. INSTALLATION & MAINTENANCE ��, r�- Z Gravity Distribution Systems — ?=xm 5-� 404 1. Install Laterals with contour of the ground. F 2. Install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the detailed drainfield layout. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue"T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Use distribution box with speed levelers and cover to surface. Divert incoming pipe down with 90-degree angle to prevent short-circuiting. 7. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 8. Waterlines must be a minimum of 10' to any tank or drainfield(a reduction to 5' may be obtained with a State waiver on lots that meet minimum lot size). Encase all water lines within 10' of septic transport lines and under any driveway/parking areas. 9. Divert all storm water runoff away from on-site sewage system. 10.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 11.No vehicular traffic over drainfield area or tanks. 12. Install Bio-Tube or equivalent effluent filter at outlet end of septic tank. 13. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 14. Inspect tank and clean filters every 6-12 months as needed. 15. Have the septic tank pumped or professionally inspected every 3 to 5 years. 16. All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. Homeowner is responsible for all property lines and easements. APPROVED DEC 16 2025 41401 MASON COUNTY ENVIRONMENTAL HEALT e- A . RET //1�,.a�°' •f• •4 . . :•e 1. 5100349 ilk PAULA JOY JOHNSON'T •of %A Ih�1 -S -RES I. 1 (—tto_LS Maples Excavating 3604638474 911 SE Arcadia Rd Shelton, WA 98584 PROPERTY INFORMATION Location:1250 E CRESTVIEW DR Shelton Tax ID:320154390020 Mai Tc: VANESSA KRISTINE SOBERANIS ET VIR 1250 E CRESTVIEW DR Use: SHELTON,WA 98584 GENERAL SYSTEM TYPE:Conventional (Non-Pressurized) ON ID: 320154390020 County Area: Oakland Bay MRA Foitl Fora ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Nero Here Inspected:11/06/2025 - Inspection Type:ROUTINE - Correction Status:No corrections needed Company: Work Performed By Submitted 11/06/2025 by: Maples Excavating Shane Maples Shane Maples COMMENTS&GENERAL INSPECTION NOTES No Deficiencies Noted -Installed biofilter. Flow tested the drainfield for 20 minutes.Drainfield accepted all water. Testing good at this time,no observed problems. GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected ------•------ ---------- — Components accessible for service: YES-- --_-- ._.._.._.- _-- ---------- - ----- —All required service performed(if no_specify omitted inspection items in notes): YES—_—Surfacing effluent from any component(including mound seepage): NO Components appear to be watertight-no visual leaks: YES Improper encroachment(structures/impervious surfaces) NO All riser lids securely fastened upon departure: YES Electrical repairs needed. If YES describe in comments: NO - Inspected components appear to be in good physical condition: YES Root intrusion on any components. If YES describe in comments: NO Settling problems observed. If YES describe in comments: NO The house/structure was vacant or used infrequently,assessment of the drainfield was not possible. NO ONSITE SEWAGE SYSTEM INSPECTION DETAIL •istribution:D-Box Full?Inspected This component was: D-Box in good condition: YES 1 D-Box outlets set to allow e•ual effluent distribution: YES TANK:Septic Tank-2 Compartment This component was: Fully Inspected Effluent level within operational limits(if NO explain in comments) YES All required baffles in place(N/A=No baffles required): YES Compartment 1 Scum accumulation(Inches,if other specify). Compartment 1 Sludge accumulation(Inches,if other specify): Compartment 2 Scum accumulation(Inches.if other specify): Compartment 2 Sludge accumulation(Inches.if other specify): No Pum•ine recommended: grainfield(disposal):Gravity Fully Inspected This component was: Component appears to be functioning as intended: YES NO Ponding present'?If YES explain in comments: NO Drainfield was vacuumed,flushed or hydro-jetted?(If YES.explain in comments) • This report indcates certain charac enwcs of the onste sewage system al the time of visit.In no nay is this report a guarantee or operation o-furore performance. Reportl0:1465651 View inspection reports online at www.onlinerme.com Page 1 of 1