Loading...
HomeMy WebLinkAboutBLD2025-01250 - BLD CD Environmental Health Review - 11/19/2025 m m ca = aiOC z5' z0) m v N v�a, aoa m CD_to O.�NOC) (D -0 CI) SDI CD 'a �� m z-- D 'p vf, no m W0 d 3 a O ED Qco 'cZ ° gym 'a = ma> va, � � v, co Cr N 0 0 g X � �c _ ;- < rt in M a m //CL N 0 EOr > CD v0 cr)(o (�DO ydo W N V1 • -^fD WX -( Q "" = cp . co a ? ° m CU V • — iov x _, PCrn N m < o (III ao3 0 O 0 ~C i m ,A N � m �, O' 3 co * O O sic �j, ,` co j (D (Q CQ O rill. G ^^ " A\ o lii HI EU ,V"Ii X ~may �, r � 0 — n e 0. cs 0 y r _. 3 m O. 4 n 3 - L 0 3. /y ea �D 0) 0� d n • ^ �_ �o�v1, / io' �\• y 11) ID ii q �oi 33- W 13 a�O se'cAi, w� CT o ain O .03c,. k.• o► 4 /.e' ** 1- / , 14114011) sa 5 C30•\• \ /\ . , , r rt14 , 3 \ `� % •� MIME \ r \ co a 8 co tC N —1 \ •. \ O, s. as o in C N N ,� in O a ) ► x -s o N a) O ao��o�` 0N m o 13 O O o (D -s �� O \ N 3 1 n o <. S ao\ o� �a Ss a tin c1 a t0 i0 ,p 2 �6 +p r E • o'� v! �' sa. �o Q• w O. pis. a 3 ems'ID CD c{o . at = o 11 n 'SD (to 7r rt CP S -T .gyp d ���°A X imp- 0 A 0 CT ? 3 co -h cD 0 l—i r o01 tr 13 to o �J g N0IC8 ` N 1� z rt,,, YI ITO" �� o 9) C G EH Setbacks A.) Drainfield/Reserve requires 10'setback from footing/foundations B.)Septic tank(s)requires 5'setback from all footing/foundations EH APPROVED C.)No foundation/Perimeter Drains within 30ft,downgradient of Drainfield/Reserve area Rhonda Thompson 11/19/2025 D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area E.)Use approved mitigation from section C1-9 of the department of ecology's"Criteria For Sewage Works Design,"when sewer . transport lines are within 10ft of water supply lines. / / \ / / \ / / \ / �r— R1p0, / NEIGHBORING �\ � / WELL I -- R75' I I I I I I 1 / \ / oQ— \ / G� \\ DESIGNATED RESERVE // 4(./ Q' \\ \ (20X35, 700SF, TYPE 5 SOILS) // \ / / Q / N— \ / . / / �-' I1 ,.,. EXISTING SEPTIC TANK '/ // O I 111110.,. I► \,\ ` ,,, I - - - / — 411 • PROPOSED ADDITION T H 1 ►� 3;5s',)>,> / . • EXISTING DF \ — • - - (AS PER WORK BY AAA; 10/1/25) l• • EXISTING HOME /. W/ DECK TO BE ", \ REMODELED • • 7,1 APPROXIMATE \ ("0, SHORELINE • PROJECT SUMMARY: SITE EVALUATION FOR PROPOSED ADDITION. EXISTING SEPTIC WAS INSPECTED AND LOCATED BY AAA SEPTIC, SEE FILED REPORT. MOST PROBABLE OSS REPAIR IS SHOWN AS A DESIGNATED • r'+', RESERVE. REPAIR WOULD LIKELY • ,,. t� REQUIRE PRE-TREATMENT, MEETING �.,61 TABLE 10 REPAIR CONDITIONS IF WELL "cN o� w.� '. SETBACK COULD NOT BE MAINTAINED. �;, • III%i .. . t CAUTIONED CUSTOMER OF VEHICULAR A,,,,. ? c�o�zs TRAFFIC IN DRAINFIELD AREAS. "`I IL01IS`�' 1 `yY. 5 CUSTOMER: ERIC CAMPBELL TEST HOLE 1 TEST HOLE 2 TEST HOLE 3 N 440., 0-15" SI LOAM NA NA ril PARCEL: 2 2 1 2 7 - 5 0 - 0 1 0 1 4 TH @ 15" ALPINE SEPTIC SITE: 210 ORCHARD BEACH DR —DESIGN— ALEX L PAYSSE,DESIGNER SHEET: SITE PLAN SCALE: 1" = 30' DISCLAIMER: THIS IS NOT A SURVEY. REFERENCES INCLUDE:APPLICANT/COUNTY PROVIDED PLATS OR 3089 E MASON BENSON RD SURVEYS. FIELD MEASUREMENTS AND COUNTY GIS. DESIGN INTENDED FOR SEPTIC PURPOSES ONLY. GRAPEVIEW WA 98546 PROPOSED DEVELOPMENT MAY BE SUBJECT TO OTHER DEPARTMENT/AGENCY REVIEW. DESIGNER NOT 360-507-1546 0 0.5 11 12 RESPONSIBLE FOR SETBACKS UNRELATED TO SEPTIC COMPONENTS. S L'EL, Pi 2 ,