Loading...
HomeMy WebLinkAboutSWG2025-00459 - SWG Application / Design - 12/4/2025 a , MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670, EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2025-00459 OWNER ERICSON ET UX JEFFREY K Phone: 360-930-1746 Address: KIRSTEN LYNN MURRAY PORT LUDLOW, WA 98365 APPLICANT Maples, Shane Phone: 3604638474 Address: 911 SE Arcadia Rd. SHELTON, WA 98584 SEPTIC INSTALLER SHANE MAPLES* Phone: 360-463-8474 Address: 911 SE Arcadia Road SHELTON, WA 98584 Site Address: 5793 N LAKE CUSHMAN RD Primary Parcel Number: 423325100008 Installing a 500-gallon infiltrator tank with solids handling pump in it, Permit Description: to lift up to existing septic since the new cabin got put in and existing elevations did not work. Permit Submitted Date: 12/04/2025 Permit Issued Date: 12/05/2025 Issued By: Rhonda Thompson Current Permit Fees Paid: $270.00 (additional fees may be required upon installation of system). Permit Expiration Date: 12/05/2028 (based on date of inspection) Type of Work OSS New Construction Components being Replaced: Pump Tank Only Surfacing Sewage? No Existing Failure? No Shoreline? No Horizontal Setbacks Met? Yes Number of Bedrooms: 2 Drinking Water Source: Public Water System Additional Details: 500g lift station Permit Conditions: 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 2 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained 4 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 5 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. ALINE Nk ()MU/ SW ( aO!5 - oo , 1 e0.(14‘ cabin �-' 10` > n f _AL DEC „VEAL � MASON COUNPryR DECE 5 2025 'yROENT HEALTH RET 4 t_aXe ► rina,n Rd, )01 -e i = Z33Z-SI -00008 a/4L/ry PUMPS L./iNCE sy 1- 1 004 Supersedes Product information presented `0 0394 here reflects conditions at time > of publication.Consult factory / PUMP ED_ regarding discrepancies or inconsistencies. visit our web site: MAIL TO:P.O.BOX 15347•Louisville.KY 40256-0347 SHIP TO: 3649 Cane Run Road •Louisville.KY 40211-1961 www zoe/ler.com (502)778-2731.1(800)928-PUMP•FAX(502)774-3624 PMA ENGINEERING SPECIFICATIONS SHEET ., °. MEMBER L SUBMERSIBLE SEWAGE*/EFFLUENT PUMP .� 3 AND on c. 267 SERIES PULP Vats A<Vf MATERIAL SPECIFICATIONS: .4 t34 85n6 613r32 - • Durable cast iron switch case,and pump housing. • Engineered plastic impeller with metal inserts.Available with cast iron impeller option. (Cast iron impeller standard on 3 PH models). • Cast Iron Base 4 4 3f4 • Motor-'/2 HP,60 cycle, 1725 RPM, 1 or 3 PH oil filled,hermetically sealed,automatic rAt ----( reset,thermal overload protected(1 PH). ,` ' 61542 • Cord-UL listed 3-wire neoprene cord and plug. L-^ j�j i h 'i + • 10'cord standard for automaticl15'cord standard for non-automatic. ,, • Shaft seal-Stainless steel;carbon&ceramic rotary. i ---- 2NPT a . • Stainless steel screws,bolts,handle,guard,and arm and seal assembl Pp/1 — � • Square Ring&Gasket-Neoprene. /�° l "" • Bearings-Upper&lower oil fed cast iron. • Corrosion resistant powder coated epoxy finish. M o 0E6, Q S 1� SUN ?OAS',32 ENGINEERING FEATURES: ryE*ROti;�F�,r ) Li., L I 6arsz i • Passes 2-inch spherical solids. Fr yE4kby1 ii • Not effected by materials normally found in drainage and sewage sumps. —' • Temperature to 130°F(54°C.). • 2"NPT female vertical discharge. SKITS • Non-Clogging Vortex Impeller Design. el.• Variable level control systems available. •May be used in those states where codes do not restrict solids size in effluent systems. cvrredtoCSA Tailed L.,lL See below for UL&CSA listings. 5i.n'_.,-d C22.240.IC8 S'ndwr Li/ 267 MODELS Control Selection Listings Model Volts Phase Mode Amps Simplex Duplex CSA UL PUMP PERFORMANCE CURVE M267 115 Auto 10,4 1 4 Y Y 267 MODELS BN267" '15 Auto 10.4 •• 4 Y Y _ N287 '15 Non 10.4 2cr3 2or4 Y Y 0267 230 Auto 5.5 1 — r Y E267 230 Non ,5.5 2 or 3 4 Y Y BE267" 230 Auto 5.5 — Y Y y_ ;.-3HY6r 200-208 .Auto 6.2 1 — N N - 1267 200.208 Non 6.2 3 4 N N i J267 200.208 3 Non 2.6 3 4 N Y F267 230 3 Non 2.6 3 4 N Y 8 '- G261 460 3 Non 1.5 3 4 N N ••Single piggyback switch included. SELECTION GUIDE 1. Integral float operated mechanical switch,no external control required. 2. For automatic use single piggyback varable level float switch or double piggyback variable level float switch.Refer to FM0477. ! 1 i.-1E tat :m s4c 3. See FM1228 for correct model of simplex control panel. %.cu r., 4. See FM0712 for correct model of duplex control panel or FM1663 for a residential alternator -t^~= c 52 tut 2 r e ;isNZ rou system. ;tow PER W VIE Dims„ u Copyright 2004 Zoeller Co.All rights reserved. IM-Tanks IM-540 The Infiltrator IM-540 is a lightweight strong and durable septic/pump tank.This watertight tank design is offered with Infiltrator's line of custom-fit risers and heavy- duty lids. Infiltrator injection molded tanks provide a revolutionary improvement in plastic tank design, offering iM-540 long-term exceptional strength and watertightness. Benefits Strong injection molded Lightweight plastic con- Integral heavy-duty green Structurally reinforced polypropylene construc- struction and inboard lids that interconnect with access ports eliminate tion lifting lugs allow for easy the EZsnap riser and pipe distortion during delivery and handling riser solutions installation and pump- outs Reinforced structural Can be installed with 6"to Can be pumped dry Suitable for use as a pump ribbing offers additional 48"of cover during pump-outs tankor rainwater(non- strength potable)tank OS Ike No special installation, No special water filling The tank may be backfilled backfill or water filling pro- requirements are with suitable native soil. A cedures are required necessary p,•, %� oEC O VE' AsoNCoo 05 2 0 117 74 040 N}�,t,1 4 25 TANK CUTAWAY l`rl4RON D f � HEAVY DUTY LID CUTAWAY Re.^Urced 24*suu ural a<ces, MID-SEAM CUTAWAY - r•„, aeinrorced water Goat mid-seam gasketed tir connection • 4ifiltrator Water Technologies Part c ADS S M. infiltratorwater.com•(800)221-4436 omme, IM-540 General Specifications and Illustrations The IM-540 is an injection molded two piece mid- � ■ ■ ■ ■ �, A 4» ■) I■f 1■I I■ 0t, A' seam plastic tank. The IM-540 injection molded plastic c=�i ``t�:— t PINti+ design allows for a mid-seam joint that has precise 1.i;`i r,o ..1 t�,,l dimensions for accepting an engineered EPDM gasket. ► _ _ Infiltrator's gasket design utilizes technology from the 'i>✓ a e�j I+ � l:. �l `\ 1 !;, I EXiER1CJR water industry to deliver proven means of maintaining hi' fib-mil i j; TH ;01i �;.? a watertight seal. tw ■1 ■ �r The two-piece design is permanently fastened using a '11w w=� IAIiA ` series of non-corrosive plastic alignment dowels and locking seam clips.The IM-540 is assembled and sold 6151+,64a:rxTrRIOR 1 rNOTl.�.- JIII\t,SIHAI' through a network of certified Infiltrator distributors. CDhNFQ,ON f'YP.; Must be backfilled and installed in accordance with mercoata"l"' Inn Infiltrator Water Technologies,Infiltrator IM-Series t a Septic Tank General Installation Instructions and ' I!1I 1' 1 i for shallow ground water conditions reference �` the Infiltrator IM-Series Tank Buoyancy Control �a Guidance. t+ �1 0- „_„_._ _ EXTERIOR •o o n11111 11r. re Please visit www.infiltratorwater.com for the latest HEIGHT information. 1f IM-540 --.----- ru IS,T,SaIr.ACCESS 0P• NY/fTH LOCKING LID Total Capacity 552 gal(2090 L) !((/ Length 64.9"(1648 mm) -_-- INLET Width 1 61.7"(1567 mm) Height I 54.6"(1387 mm) I Maximum Burial Depth J 48'(1219 mm) Minimum Burial Depth 6"(152 mm) Maximum Pipe Diameter 4"(100 mm) 1 Weight 169 lbs(77 kg) :014111UOtt5 ;ASKET TASK TOP HALF SUM CI RI I ANK INT ERIOR AP A ®` _ED AIIGNAlNI V DO11E1 i.t`.t D'1i 1011 .14I r DEC 0 5 2025 MASON COUNTY ENVIRONMENTAL HEAIIIIIIIIIIIIIIIIIIIIIIIIIIM RET Contact Infiltrator's Technical Services Department for assistance at 1-800-221-4436 or info@infiltratorwater.com rill..111.11111111.11...— Infiltrator Fa-:of//ADS ;Litt:675 4