Loading...
HomeMy WebLinkAboutswg2025-00426 - SWG Design al ': MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT400 FAX:360-427-7787 On-Site Sewage System Tank Only Permit: SWG2025-00426 APPLICANT MAIER TRUST COREY & KATINA Phone: Address: 26076 SE 156TH ST ISSAQUAH, WA 98027 SEPTIC INSTALLER Schoening Excavating LLC Phone: 3607422982 Address: 121 W Grizdale Dr Shelton, WA 98584 SEPTIC INSTALLER BRAYDEN SCHOENING* Phone: 360-742-2982 Address: 121 W GRIZDALE DRIVE SHELTON, WA 98584 Site Address: 651 E BEACH DR Primary Parcel Number: 321045300020 Permit Description: Septic and pump tank replacement Permit Submitted Date: 10/23/2025 Permit Issued Date: 10/27/2025 Issued By: Rhonda Thompson Current Permit Fees Paid: $270.00 (additional fees may be required upon installation of system). Permit Expiration Date: 10/27/2026 (based on date of inspection) Type of Work OSS Repair Components being Replaced: Septic and Pump Tanks Surfacing Sewage? No Existing Failure? Yes Shoreline? No Horizontal Setbacks Met? Yes Number of Bedrooms: 3 Drinking Water Source: Public Water System Additional Details: IM-1530 for septic and IM-1060 for pump Permit Conditions: 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 4 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 5 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360-427-9670, extension 400. IM -Tanks ... IM-1530 The Infiltrator IM-1530 is a lightweight strong and durable septic tank. This watertight tank design is • offered with Infiltrator's line of custom-fit risers and heavy-duty lids. Infiltrator injection molded tanks provide a revolutionary improvement in plastic septic IM 1530 tank design, offering long-term exceptional strength and watertightness. Benefits lig SO bilk Oil Strong injection molded Lightweight plastic con- Integral heavy-duty green Structurally reinforced polypropylene construc- struction and inboard lids that interconnect with access ports eliminate dic- tion lifting lugs allow for easy TW'm risers and pipe riser torsion during installation delivery and handling solutions and pump-outs OS ilia Sill iliiii Reinforced structural Can be installed with 6"to Suitable for use as a septic No special water filling ribbing and fiberglass 48"of cover tank, pump tank, or rain- requirements are bulkheads offer additional water(non-potable) tank necessary strength TANK CUTAWAY Infiltrator �-- t - • .—Inlet Side EZsnap Riser ----,, HEAVY DUTY System ' , LID CUTAWAY Reinforced 24"structural Partition access port baffle wall - N ' o • z T � <J 0 C � z n —t Xi rri .13 • { -+ a n, 411111111, Structural rtn bulkheads r F a N`+ Infiltrator' Water Technologies MID-SEAM CUTAWAY Part of HADS Reinforced water tight mid-seam gasketed connection infiltratorwater.com•(800)221-4436 Il 1-1530 General Specifications and Illustrations LIFTING LUG(TVP.) RISER CONNECTION(TYP.) The IM-1530 is an injection molded two piece LIFTING STRAP(TYR) mid-seam plastic tank. The IM-1530 injection „—_"_._".,."... ,. _, molded plastic design allows for a mid-seam 1111411111111111111111.1111111101r111i `'g1►111 :,joint that has precise dimensions for accepting ; jr- y�l 111111ir AEI 11 PP 1—*,an engineered EPDM gasket. Infiltrator's gasket firi d\1 11 11 11.' ° �'.11 of 817 �:.r d o o j P a +0-11, , rs67 design utilizes technology from the water 0I�i ! A 1111 Ir kl Sill ilk I EXTERNIp�.:+� OO ' O :�► WIDTI industry to deliver proven means of maintaining 116 uil 11 1p1 II hhT___i' II 11 a'] a watertight seal. 1tr' I' I I I I I M I I I I ,I � W a�.�11all.,,:,'ll.���.h,111 II-.1��.,��1:11�•:��'/.11:1 The two-piece design is permanently fastened using a series of non-corrosive plastic alignment 175.6[4.4601 EXTERIOR LENGTH - dowels and locking seam clips. The IM-1530 is assembled and sold through a network of certified Infiltrator distributors. OUTLET TEE- Must be backfilled and AI - tiVr El L NI.- 0installed in accordance 54 I with the Infiltrator IM- _ _ _ _ _ (12841 EXTERIOR and CM-Series Septic Tank • �.ir,U HEIGHT r r! h'CL General SEAM CLIP I I.:•�� � Installation Instructions. "FT'NG STRAP i r I ElFor shallow ground water �� � conditions reference the Infiltrator IM-and CM-Series SCAN ME Tank Buoyancy Control 024.0[610]ACCESS PORT Guidance. 04[102]PVC OR ABS WITH LOCKING LID(3) INLET TEE 10.1[257]FREEBOARD 04[102] PVC OR ABS Please visit www.infiltratorwater.com or scan QR OUTLET TEE ''''�lN l IWI i code for the latest information. +6.9xAIRSPA 3.0, I [76] , : PER COLE 02[S]WALL 44.0 THICKNESS IM-1530 i L PER CODE LIQUID 2[51]X 2(51J J DEPTH FIBERGLASS Working Capacity 1537 gal(5818 L) SUPPORT(4) Total Capacity 1787 gal(6765 L) --- Airspace 16.9% Length 176"(4460 mm) Width 62"(1567 mm) CONTINUOUS Length-to-Width Ratio 2.8 to 1 TANK TOP HALF ELASTOMERIC GASKET Height 55"(1384 mm) TANK Liquid Level 44"(1118 mm) INTERIOR I q' SEAM CLIP Invert Drop 3"(76 mm) ALIGNMENT Fiberglass Supports 4 DOWEL TANK BOTTOM HALF Compartment 1 or 2 Maximum Burial Depth 48"(1219 mm) Minimum Burial Depth 6"(152 mm) OCT 27 2025 Maximum Pipe Diameter 4"(100 mm) MASON COUNTY ENVIRONMENTAL hEALTh Weight 501 lbs(228 kg) RET Contact Infiltrator's Technical Services Department for assistance at 1-800-221-4436 or info@infiltratorwater.com Infiltrator- Part of//AM I M -Tan ks IM-1060 The Infiltrator IM-1060 is a lightweight strong and durable septic tank. This watertight tank design is offered with Infiltrator's line of custom-fit risers and heavy-duty lids. Infiltrator injection molded tanks provide a revolutionary improvement in plastic septic tank design, offering long-term exceptional strength IM 1o60 and watertightness. . - Benefits Oil ilia 1111 Ilill Strong injection molded Lightweight plastic con- Integral heavy-duty green Structurally reinforced polypropylene construc- struction and inboard lids that interconnect with access ports eliminate dis- tion lifting lugs allow for easy TWT"" risers and pipe riser tortion during installation delivery and handling solutions and pump-outs all la la ilik Reinforced structural Can be installed with 6"to Suitable for use as a septic No special water filling ribbing and fiberglass 48"of cover tank, pump tank, or rain- requirements are bulkheads offer additional water(non-potable)tank necessary strength TANK CUTAWAY Inlet Side Infiltrator HEAVY DUTY EZsnap Riser - System LID CUTAWAY Reinforced 24"structural .1,r access port Partition baffle wall 4111 • .Y1 , i AP r-.'� Structural D bulkheads 2025 MID-SEAM MASON NV, NMI HEALTH R CUTAWAY Infiltrator i Reinforced water Water Technologies . tight mid-seam gasketed Part of i/ADS connection infiltratorwater.com •(800)221-4436 IM-1060 General Specifications and Illustrations LIFTING STRAP LIFTING LUG RISER CON NEC TON The IM-1060 is an injection molded two piece TYPICAL, (4 TOTAU RYPICALI mid-seam plastic tank. The IM-1060 injection , �, molded plastic design allows for a mid seam =+n�_-& joint that has precise dimensions for accepting A s • • r' A an engineered EPDM gasket. Infiltrator's gasket t :\n,iii:.:11:11::-.7.71:elitelli4:- 1 �o y.'g. _;� o .11 �2 design utilizes technology from the watero °o Irak':' ns»o� EXTERIOR industry to deliver proven means of maintaining `_ ��11j� ? �+++ a watertight seal. h' � fi I ^ ik%, {4rJ/Psd/r ♦4 14.1+~y4i�-�k The two-piece design is permanently fastened using a series of non-corrosive plastic alignment 127.013226j EXTERIOR LENGTH dowels and locking seam clips. The IM-1060 is assembled and sold through a network of certified Infiltrator distributors. OUTLET Must be backfilled and L ' '� installed in accordance I� _11_ Ili 5a , L.o +� - - (1389) with the Infiltrator IM- `I'�IY o� 111)" , EXTERIOR ■ ■ Y ■'a and CM-Series Septic Tank SEAM CLIP I HEwHr ! �( ll• _! General (TYPICAL) i■ •oa • 1.4 -■ LIFTING STRAP `,, it ...... t■v■ ■o,■■ q Installation Instructions. (TYPICAL) ■= - For shallow ground water �� conditions reference the Infiltrator IM- and CM-Series SCAN M E Tank Buoyancy Control 0 4(1021 0 24[6101 ACCESS OPENNGS WITH LOCKING UOS(2) Guidance. PVC OR ARS 04[102)PVC OR INLET TEE 10.2(2601 FREEBOARD ABS OUTLET TEE Please visit www.infiltratorwater.com or scan QR �.r .■.. code for the latest information.- OUTLET . l ' CPER ' (7360)J 1 1 PER °. I CODE IM-1060 I 44.0 i I FIBERGLASS (11181 FIBERGLASS SUPPORT LIQUID SUPPORT Working Capacity 1094 gal(4141 L) PICALI DEPTH )WITHBAFFLE WALL WHERE Total Capacity 1287 gal(4872 L) REQUIRED Airspace 16.5% Length 127"(3226 mm) Width 62.2"(1580 mm) y TANK TOP I CONTINUOUS Length-to-Width Ratio 2.3 to 1 HALF GASKET Height 54.7"(1389 mm) -r TANK 4 , i SEAM CLIP Liquid Level 44"(1118 mm) INTERIOR litLA ,. Invert Drop 3"(76 mm) ALIGNMENT I DOWEL Fiberglass Supports 2 \ TANK BOTTOM HALF 1 Compartments 1 or 2 Maximum Burial Depth 48"(1219 mm) 11111111101111111RP".1.11111 Minimum Burial Depth 6"(152 mm) Maximum Pipe Diameter 6"(152 mm) OCT 27 2025 Weight 320 lbs(145 kg) MASON COUNTY ENVIRON, g T'- RF' Contact Infiltrator's Technical Services Department for assistance at 1-800-221-4436 or info@infiltratorwater.com Infiltrator Part of// DS w_ a r N r�� c� V O Lrt V , Z o -0 z . rin --I m 1.--- '------.._ 3 .73 r N 4 m73 0 � O-r ,4 _ N 3 N C O ITT Lri "V a4 el ch (� (o e f 13 0 c t, _ 6 /0-- , ...46, LI,. \ e. . \ .., e• ,,, ,_, ----t.., w • 'per V\ < W J\ V 1 4 V V ;N.‘ G. R 1 . - - / , • 1-,, 1 / / / 5 7 11 0 0 C) , :::) 4.... 0 e z . s c ... c s d 0 G co, s ° i s � F��- c► 6- X, "b { O C .a '; •" ' r /- i P .4- 0 4, A-7 ea roc:9$ 1.1:-c,, 6 "/ --- , U 0 N `o