Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
swg2025-00378 - SWG Application / Design - 9/17/2025
M . MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 400 BELFAIR:360-275-4467,EXT 400 Public Health & Human Services ELMA:360-482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2025-00378 APPLICANT EMPIRE HOME CONSTRUCTION LLC Phone: 360-751-8062 Address: PO BOX 241 KELSO, WA 98628 SEPTIC DESIGNER PAULA JOHNSON* Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 Site Address: 191 E Alderney St Primary Parcel Number: 322325209015 Permit Description: 3BR Nuwater w/ local waiver to foundation Permit Submitted Date: 09/17/2025 Permit Issued Date: 11/04/2025 Issued By: Jeff Wilmoth Current Permit Fees Paid: $825.00 (additional fees may be required upon installation of system). Permit Expiration Date: 09/23/2028 (based on date of inspection) Permit Conditions: 1 Approval of this septic permit does not approve the building location. Building location is subject to approval from all applicable departments and regulations. 2 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 3 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 4 Drain field installation not to exceed designed upslope and downslope depth specified on design form. 5 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 6 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 7 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call: 360-427-9670, extension 400. OFFICIAL USE ONLY MASON COUNTY DATE RECEIVED: /�^ - 11 - / enit. C Up AMOUNT RECEIVED: I RECEIVED BY: CO W CO f Public Health & Human Services go25 I DNuNEt�1lJ� ° C/) Cl, Environmental Health W-9670,ext.400 or 360 275 4467,ext.400 S W G A Q3,6. _ D 6 34(f (p 70 0 415 N.6th Street- Shelton,WA 98584 �,) o Z C/) ON-SITE SEWAGE SYSTEM APPLICATION D m n I APPLIcAt.T ?r.I:.'A;= C I Empire Home Construction (360)751-8062 — C MAILING ADDRESS-STREET.CITY STATE ZIP CODE P.O. Box 241 o Kelso WA 98626 = co SITE ADDRESS•STREET.CITY.ZIP CODE ` 191 E Alderney St /....ii _� Union WA 98592 g CA) 9. NAME OF DESIGNER �5 i 0 PHONE C I N Arrow Septic Designs, In \/ (360) 898-2255NAME OF INSTALLER PHONE 0 Cr) 73 I N Mason County Excavatin j (360)490-3144 I w PERMIT TYPE(select or.e) `."---.. 143DRINKING WATER SOURCE O it RESIDENTIAL OSS rl COMMUNITY CSS 11 I C COMMERCIAL OSS 6 PRIVATE INDIVIDUAL WELL 5"PRIVATE TWO-PARTY WELL Z I N TYPE OF WORK(select one) 7 PUBLIC WATER SYSTEM , ff,NEW CONSTRUCTION/UPGRADES ff REPAIR/REPLACEMENT OTHER DETAILS(seleC all mat apply) 0 TABLE X REPAIR I Ut SUBMITTALS 0 SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINECO I'g DESIGN FORM(REQUIRED) liif SEPTIC DESIGN(REQUIRED) BEDROOMS LOT SIZE WAS LOT CREATED AFTER 4/12025? O I N7 WAIVER(S)(IF APPLICABLE) 3 BR .25 ac p YES El NO 1 — S` I O DIRECTIONS TO SITE AND SITE CONDITIONS;er rocked gate; co Head east on W Alder St toward N 6th St. At the traffic circle, take the 3rd exit. Go up the I CO hill then take slight (R) onto E McReavy Rd. Turn (L) onto E 5th St. Turn (L) onto E Port b I o Townsend St. Turn (R) onto E Alderney St. Destination on (L). Yellow sign: "Empire Homes o 191" 01 I SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. 01 OFFICIAL USE ONLY BELOW THIS LINE UPGRADE FAILURE SOURCE(Icr reporting purposes) ❑VOLUNTARY ❑MAINTENANCE/PUMPING ❑BUILDING PERMIT ❑HOME SALE ❑COMPLAINT ❑OTHER. INSPECTOR SOIL LOGS COMMENTS'CONDITIONS ;, L A-8 3 RECORD DRAWING AND INSTALLATION REPORT SOIL CODES: V=VERY G=GRAVELLY S=SAND L=LOAM SI=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINAL APPROVAL I ECTOR SIG'ATURE DATE APPLICATION EXPIRATION DATE A- .ATION • APPROVED:ISSUED BY DATE FORM ►LA� q'232s 9- 23'Z ' �lMj (l'3.,25 T S MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE Revised:4/14/2025 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 3 2 2 3 2 — 5 2 — 0 9 0 1 5 A design will be reviewed when 3 copies of each of the following are submitted: Completed design form that has been signed and dated. '" Scaled layout sketch. including all applicable items on checklist. Scaled plot plan. including all applicable items on checklist. ''Cross-section sketch, including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.Maximum paper size: 11"X 17" PARCEL IDENTIFICATION Permit Number: SWG_ 2 ` C—)o310 Designer's Name: Arrow Septic Designs, Inc _ Empire Home Construction Designer's Phone Number: (360)898-2255 Applicant's Name: 171 E Vuecrest Dr Mailing Address: P.O. Box 241 Designer's Address: Kelso WA 98626 City State Zip Union, WA 98592 City State Zip Designer's Email paulaj@hctc.com DESIGN PARAMETERS Treatment Device 't ❑ Glendon 0 Sand Filter 0 Mound 0 Sand Lined Drainfield 0 Recirculating Filter 'ATU r%1 L Other Treatment Level(check all that apply): ]A El B ❑C El BL1 7 BL2 ❑BL3 ❑E PI N Drainfield Type ❑Gravity Fie Pressure C'Trench ❑ Bed 0 Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 Schedule/Class 40 Daily Flow:Operating Capacity 270 gpd Length 50 ft Daily Flow: Design Flow 360 gpd Diameter 1.25 in Septic Tank Capacity(working) NuWater BNR-500 gal Number 4 Receiving Soil Type(1-6) 4 Separation 5 ft Receiving Soil Appl. Rate 0.6 gpd/ft2 Orifices Required Primary Area 600 ft2 Total Number of Orifices 40 Designed Primary Area 600 ft2 Diameter 3/16 in Designed Reserve Area 600 ft2 Spacing 60 in Trench/Bed Width 3 ft Manifold Trench/Bed Length 200 ft Schedule/Class 40 Elevation Measurements Length header ft Original Drainfield Area Slope 4 % Diameter 1.25 in New Slope. If Altered 4 % Preferred manifold configuration used? giYes 0 No Depth of Excavation Up-slope 10 in Transport Pipe from Original Grade Down-slope 8 in Schedule/Class 40 Designed Vertical Separation 12+ in Length 20 ft Gravel-based Drainfield Required? ❑ Yes 1E6 No Diameter 2 in Pump Required? EZ Yes ❑No Dosing and Pump Chamber Pump/Siphon Specifications Number of doses/day 4 Diff. in Elevation Between Pump& Uppermost Orifice 5 ft Dose quantity 90 gal Drainfield Squirt Height/Selected Residual(head) 2 ft Chamber Capacity(flood) 1,000 gal Uppermost Orifice g Higher 0 Lower than Pump Shutoff Pump controls: Please check those required. Capacity @ Total Pressure Head 23.6 gpm Eif Timer 0 Apse Meter ❑VEvent Counter u m Calculated Total Pressure Head 8.51 ft If Timer: P on 2 minutes p off 6 hours Comments APPROVE NOV 0 3 2025 MASON COUNTY ENVIRONMENTAL HEALTH Revised:4/14/2025 JBW -eZ) L ©-c-Gi DESIGN FORM—PAGE TWO Assessor's Parcel Number: 3 2 2 3 2 — 5 2 -- 0 9 0 1 5 Permit Number: SWG a02.5.'«O 34,7 DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch Ed Test hole locations 60 Drainfield orientation and layout Reference depth from original grade: Soil logs ft Trench/bed dimensions and 10 Septic tank 10 Property lines critical distances within layout 12fDrainfield cover ❑ Existing and proposed wells D Box/Valve box locations Reference depth from original grade within 100 ft of property QJ Septic tank/pump chamber and restrictive strata: ❑ Measurements to cuts, banks, and locations r2i Laterals,trench/bed,top and surface water and critical areas 66 Observation port location bottom ❑ Location and orientation of 60 Clean-out location 0 Curtain drain collector curtain drain and all absorption 66 Manifold placement 0 Sand augmentation components 10 Orifice placement Other cross-section detail: O Location and dimension of 10 Lateral placement with distance Observation ports/clean-outs primary system and reserve area to edge of bed Other Information O Buildings 10 Audible/visual alarm referenced Yes No gil Direction of slope indicator Q1 Scale of drawing shown on scale El 0 Design staked out 10 Waterlines bar 0 56 Recorded Notices attached 66 Roads,easements, driveways, O Elevation ben _s ark and relative 0 Waiver(s)attached parking elevations o E em components 10 0 Pump curve attached ❑ G1 Evaluation of failure � North arrow and scale drawing .9 , ,� shown on scale bar .�'' Non-residential justification Z.• 4)1/4r Ellif Waste strength t_491 . 04, .t. .1 0 121Flow .i IG O'er, The undersigned designer must be notified .,.0 � . n E0 Yes 0 No Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public 1-lealth and determined it to be in compliance with state and local on- ' e regulations: c L..)cLv (t- 3 tZ5 En iro{Mental Health Specialist Date CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: Gj'2.3 "a'8 ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must he installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is require This form may be scanned and available ,pubic,itleyv-on the Mason County Web site. Revised:4/14/2025 41AsoN ' V �� 3 P.025 VIRpN41E��TAL '";; EXHIBIT "A" (MAP) DPC 2S -1S 0 )1 ' N - - Alderne i Y St. - vacate y oper ; n of law-_ - .. T" - T . .� .. I Pairoc ef� .�C 11 I12 er; ; I Pag!rocoe l B j i[ lp 151617 ! 18 QI I I 60' 32232-52-09011 --1-___ F_00NM: I S.l I I 1 ; ; ; L tZ� . Itey-vacated by operation of law A U CLAR ION OF PARCEL COMBINATION FOR Parcel A mpire Home Contruction LLC portion of 32232-52-09011 Box 241 (Lots 11-14,inclusive,Block 9, (------,\\ . WA 98626 Grays Harbor&Union City Railroad Addition to Union City.boos 2,page 1) N.,. ..c-------)-// k No e'. 7-or Plfrcel 13, S tZ b?c# 2S-26, R'FN 2.22.6691 DECLARATION OF PARCEL COMBINATION OF PARCEL 32232-52-09011 SEE EXHIBIT B \ DAT jeE OV INN j V/1S1202 ' -r.( Director of Community Services 2226692 Page 4 of 5 06/13/2025 09:35:00 AM Mason County, WA \DO '® i � I • 101 v�A,1c� 35 e PC ;ic:\ � /Sol' � OC LA-to 1 . __- 4 --c T .E5 ® 6 " .e-"F' 1 171 : ZZf 24' GSL .V v v S (p w �Pf� gZC '� `TO g-ACTIVAI G/ '. 9cPE X t 5 rL-riatJ f2: 22P GSI.. -t-g \ \ \ ' -fie t-1 e7c'J cc r-'P am \ 12-L' \'r/ \ \ \ .... 4 S., '2.'2-4 5 L. -I- e_cresS • " b' 1 fey: \ \ Po R�rt 't'G wl U P1 �91,0 /..)- \____ i� !. 7 3 Audio-Visual Alan 1 O2 Clea,:out -,— 1 CO Z'r,n�n�4424I N.Ax".% \ 0 NuWater BNR-500 ATli r2\\C e-vD k`-;\ i 4 O 1,000 Galion Pump Ch2. J I Q Valve Control Box I 5N ems c* 0 1 6 5 1 p .G . w !i H ��p 13.s tx 45 ' cscA- . F Low�2 ST �'�'` S a: .\3 r s(. L.F_ : Ce _ z0 I 0 'a ZT, ' 4-0 Lo T P l.-At, I Afr Wt-12.c-V- -- 5 2232- 2,-CA 0 VS. .0';• "44)) i K;otiffi-•-..-.4v-,.1, oi . upi . ; u3,4,-,-- -/)1 /.5, 72. 1.,,,..111, ' iqr. y,, ---... ‘,. . F (5-''e, Sto 34B �•• PAUL.A JOY JOHNSON ��i r •" SJti-k4\41t4fr. , Jpt N oh�`�`;�ote to installer"" p p �������� �} Sleeve waterline when within 10' R0i ' . of septic transport line. Maintain NO �$ 10' minimum between water *SON V n 4 3 2025 ., ,;. line and septic tanks/drainfield. UNTYEA;�/RoNrvi .„ ,f Jew ENT AL HEALTF 2" vt ,off LN4- r (•L �r S 17 3; T UaoX cAraltI `r q.Si 0 mtru t8 vks..,k% Fe...e Les 71Z=Let Lam- — ,, .--} oro- elsse Ir 3o IA I . 25 Feet'L.�.S� . f • °'i-- 1"cs . 3 S C¢SZ-R. : ( 'e l a n a` s' !a r 151 ioTurui_ 3b c�.�n, 1 f 1sn41 Grade Zti r 5 "2- 17 f4-5°' j______ --------irj—X'( 31 Lk'f,2I2( Qk-- ti.zs v. 4-4-4- . 3•6x.k-q‘..._. to " •I';..'t . i, . . � /� ,A•, ••�,.� f/l.•jai ��'• � K 3h�, ;� . y�� s yJ • b1��JsD ;�`Ci I2rrfi '",i PAULA JOY JOHNSON •Y'.r > Ct AEsaii4G�'` $vrtA-\\Aesd Cass--stc,-f•ruet. 9-9 - Zs SL,ii.a. : 1"_ 1 r SCREW ON CAP 1 .r -' NOTE Err 1 ' (V r 2 ' . 4 O=OBSERVATION PORTS--TO BE 4 " 45 DEGREE ELBOW OR • PVC PIPE FROM BOTTOM OF TRENCH LATERALSWEEPING 90 • TO FINISHED GRADE. REMOVABLE • END OF CAP SHALL BE INSTALLED ON DITC OBSERVATION PORT PIPE. GLUED ON DETAIL TEE AT BOTTOM. CLEAN OUT MINIMUM OF ' 4 IN SYSTEM. • • NOTE, CLEANOUT TO BE FROM 0 TO 6 LATERALS ARE TO BE CENTERED INCHES BELOW FINISHED GRADE. IN TRENCHES MARK ENDS WITH REBAR. CLEAN OUT REQUIRED AT END OF EACH LATERAL. 50 ' TRENCH END MANIFOLD ( 600" ) PPROvE ORIFICES 4,0'" OC ( IO ORIFICES Se FROM MANIFOLD 3o"FROM ELBOW V SON coo,r FINISH: 3 2025 .i:', Ja�� NTAL!EA;TL, Length Length Orifice # Distance from Distance from Lateral # (In.) (Ft.) Spacing Orifices Feeder Line(In.) Cleanout(In.) 1 600 50 60 10 30 30 2 600 50 60 10 30 30 3 600 50 60 10 30 30 4 600 50 60 10 30 30 Total Lateral Length 200 Total#Orifices 40 GPM = 23.6 Dynamic Head Calculations Selected residual pressure: 2 ft. Length (Ft.) #Orifices Transport Pipe 20 40 0.20 ft. Feeder Total Lateral Line Length • Lateral#1 50 2 52 10 0.29 ft. Lateral#2 50 7 57 10 0.31 ft. Lateral#3 50 12 62 10 0.34 ft. Lateral#4 50 17 67 10 0.37 ft. Total Elevation Lift AP p R . . 5.00 ft. Total Dynamic Head V E '` ? 8.51 ft. NOV 0 n!ASQN COU 3 2325 .' II T yEivvipmEN t, . J8yb TA(HEi.Tr, SECURED UD WITH GAS TIGHT SEAL THREADED UNION • 24•DIAMETER • ACCESS RISER SERVICE l` ) VALVE� FINISH GRADE r_...ii h _ -- 1 :i ' -Ts-- 1-- 'TO GRAINFIELD PI 11 FROM SEPTIC J • TANK — 1 ■ li EMERGENCY STORAGE • - ANTI SIPHON VALVE" HIGH WATER ALARM LEVEL ----► .INOEPEHD€IT ��OFF LEVEL WORKING VOLUME I , — FLO FLOAM t FOR FLOAT szonse i:" "♦' MOUNTMK3 1C �� � ilij_..1...... CHECKVALVE•/- ..`.4 \1()iaea�tErrrs - l1 I1 suB iBi E `' I .�,� r • • r_ cEru C' PAULA JOY JOHNSON '•- \ PUMP CHAMBER GAL PUMP 4'ti+✓ S� 15tG1�C�z " -W i/i 571 � L, AS NEEDED Septic Tanks must meet standards require- d by eA 2tanks andFIGURE. 2 manufacturer must be on Dept of Health list o re6. gistered sewage, • 7 WA n(H Publication#337-022 Page 35 of 65 137 •1 Bronze construction available(139 series) .!i • High head version available(145 series) • Double shaft seal versions available for added protection on models 140l145. Flow-Mate For more information,see Technical Data Sheets FM2782,FM2783. In high head dewatering or effluent applications where pumping _ _ 7J11?PERFORMANCE CURVE performance is critical, this robust �= „ 1400EL 13117404145 family of pumps is known for reliability, y durability and performance. These „� - r' „ '11111111111111■■■■ pumps are especially suited for harsh ' ,IIIIMMIIIINIIMII environments. Zoeller's cool run design Ell and corrosion-resistant,powder coated ■,.��� 3 + epoxy finish add up to a long-lasting, 1 Y n„■����� 13 trouble free product. ,"■■■.■■11 m APPLICATIONS: g • STEP or onsite applications g , ..�`����� 'C • Water transfer ''°- . 111111111w,, ��� in • Light commercial dewatering ..■■'�■■111111 SPECIFICATIONS: r� x ■■..'�"'■■ • 1-1/2"NPT discharge © u .■■■.,,,`■■ • 1/2 HP through 1 HP MADE IN THE USA , .■�■,,."■ • Available in automatic or nonautomatic NigA UAW Of III WEE • Model 137,139,140:1/2"(12 mm)spherical solids •■■■■®■■111111 m Sr, .- ID r ,m capacity with vortex impeller GALLS . • Model 145:3/4"(19 mm)spherical solids capacity with u , >o >,,,,,. vortex impeller y 1 � �g `., g LL PUMP PERFORMANCE CURVE �ro�t�i�tf ( MODEL 151/152/153 Dose-Mate 50 , - . - I This is our fastest growing line of effluent 14— es 153 i pumps.The 150 series is truly a workhorse designed for reliability under extreme 12- 4° 1 conditions in an effluent environment. 150 series pump curves cover a wide range = 10_ 35 152 of applications. They are well suited to 30 applications with low pressure pipe(LPP) 6_ 25 151 and enhanced flow STEP systems.Zoeller's cool run design and corrosion-resistant, 0 6_ 20 powder coated epoxy finish, in addition to the hermetically sealed, oil-filled motor 1s , and non-clogging vortex impeller add up to 4— _ a long-lasting,trouble-free product. 10 ('� �- 2 APPLICATIONS: �� 5 • STEP or onsite applications �'��� 0 1 MBED IN�TIHEp�A 10 do 50 60 70 8C 90 too • Light commercial dewatering GALLONS LITERS SPECIFICATIONS: u +� + vio nao 3;0 aso FLOW PER ' . ".. • 1 1/2"NPT discharge `; 9A,� r' • 3/10 HP through 1/2 HP '41COO �y n '''///I/p • Available in nonautomatic or with a variable level 4/i C'3 s„"t. piggyback mechanical switch F4, tii(` )' • 1/2"(12 mm)spherical solids capacity with vortex �O/I/ ✓ " -ft thermoplastic impeller �l ,4, �F1,, r t, For more information,see Technical Data Sheet FM2784. /94• r,. ©All rights reserved. ZOELLER PUMP CO. 1502-778.2731 1800.928-7867 I zoelterpumps.com `�0"/„. 9 9 2" WATERTIGHT LID VENT(typ) DUAL PORT AERATOR-, RISERS t YPi t 4) f�-1 • 1 5 i 36,MAX 1 PVC(TYP) \ ° 1/2'PVC 1 /2—,,, ti — ,. AIRLINE r MASTIC \ 4' ' --- i '---'t-- - 2'COUPLING I : I 58 REDUCER 1---- 6" Y TEE 1"1'PVC SLUDGE;__..\-. t,__..---.--,------ -----------------* -C-4-' 1: I ir { ( 12" RETURN LINE I i I i 2'PVC �I I j I TRASH CHAMBER --1_,,--iDIGESTER CHAMBER ( CLARIFIER OPERATING CAPACITY:417 GALLONS OPERATING CAPACITY:421 GALLONS I CHAMBER i FLOOD CAPACITY:490 GALLONS FLOOD CAPACITY:49L GALLONS 160 GALLONS FLOOD:191 GAL. I 65' Sg• { . , �• r 50' . 54ist i53. . .4 p R A o 0 0 38' o . 0 < 1•X 1 t2' o TEE .hr,• ` tie; kte N4f °• . ° 0 l Q ^� E H A • DIFFUSER BARS(2) .h T � PARALEL TO TANK WALL 4" 3- SLUDGE RETURN J --,-- , � j / 1.5'TAPER XI. hEw STONE-FREE NATIVE SOIL OR COMPACTED SAND i INSTALLATION INSTRUCTIONS OVER STONY SOIL 1)Excavate tank hole with vertical walls tc 1 foot larger than tank on ail sides. 2)If bottom of hole is stony,install 3"of compact sand&level A' 9"-2' 4' i out with screed. __ _ _ _ _ _ _ _ _ _ __ _ ', 3)Install tank in center of hole,keeping 1 ft.void space on I 1 all sides. I 24•BLOWER I 24'RISERS P) 4)As tank is filling with water,fill in void space with compact ! ()USING CAST I 1 granular(sandy)soil free of large clumps of clay. I 1 N TOP OFt r 1 5)Install rest of system,&affix risers to acapters with ' waterproof adhesive. 2 1 I • i ` 4•$. 6)Perform watertightness test in field as required by local I i I urisdiction. I 1 7)Upon approval to backfill,carefully backfill with native I ;I 1Y RISER 1 • soils over top of tank. I TRASH CHAMBER I I DIGESTER I i CIABI IERI , 8)Final grade the surface to avoid chanelling surface I i _ J water toward tank. - - -- ` - _\_ TOP VIEW 1'=28 It AEROBIC TREATMENT TANK DETAIL FOR 4� �' :� " ... Nu WA TER BNR-500 TREATMENT UNIT 4kijpv . 1 ` ENVIRO—FLO, INC. REVISED: Wastewater Treatment Technologies 3/01/12 ''a z': `^w T,e►!: . P.O.BOX 321161, Flowood, MS 39232 SCALE, (877)836-8476 (601)845-4716 fax - www.enviro-Ro.net 7 rr = 7.4 ' 1 O1\- iIkVY8 V Envlro-Flo.lnc • i rii.,1 111 1 '•,._ -4Ir-rigt .. .41;e0*< '..:i I _ -,"'''' dlr 4)?jr4 0111111-'-'-' - --- :/ 0 Ai -13,,,Q1dv- . -10-...... e__/ - . ../..-1/4.® ., loy 1 alb 0 V46©, Ift-s 0 C' l Ca re* I 4000.0,-. �l� � ita I VS 1,-8ri. Lii .� f PARTS LIST NuWater NR Assembly Diagram I A.DUAL FORT AERATOR M.POLY DIFFUSER BAR(2'. 'K 47 B.318"RUBBER 90°'At/CLAMPS(2) N.r'PVC(3 12"SECTION) C.318"BARBED ADAPTOR X 112"NPT(2; O.1"SLIP CAP D. 117'SLIP X 1/2"NPT ADAPTOR P :/8"CLEAR PVC HOSE(OPTONAL 5.; E v.STREET X 1/2"NPT BUSHING(3) 0 1/2 PVC PIPE(BY INSTALLER) i 0 1 i2"90°ELBOW(3) R. 1"PVC PIPE(BY iNSTALLEP,) G.1"X 1"X 1/2'TEE S.T PVC PIPE(BY INSTALLER) N > CtI4iry 1"90°ELBOW(3) T.1/8'BARBED ADAPTOR TO (2 � �" 2"X 1-BUSHING U.1/2"STREET X'V3'NPT Bp� 2) - J 2"SANITARY TEE V 1/2 PVC COUPLER(2) 4f s1/� /1/l? 0 k 17 1"PVC CROSS W 2"COUPLER(BY INSTALLERY�CQ {J/Y n _ 1"COUPLER(BY INSTALLER) U1VA't / si'.j� �C 4A1*ibil1Fti f Revised 2/25/12 l Clu uu Septic Deisigivs, Sac. ;�'' • fi r NuWater BNR Pretreatment "' •0 INSTALLATION & MAINTENANCE l ;r 5t03e9 Pressure Distribution Systems '^Q� PAULA JOY JOHNSON � Lid '1� 51 1. Install Laterals with contour of the ground. q 9 IS" 2. Install trench bottoms level. 3. Install locator tape or rebar ndicat d on each end theplot plan drainfield t 4. Install observation portsOne required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock, (do not glue), after pressure test and Environmental Health Dept. approval, turn orifices down (6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade, run the filter fabric at least 2 inches down the trench wall. 11. Waterlines must be a minimum of 10' to any tank or drainfield (a reduction to 5' may be obtained with a State waiver on lots that meet minimum lot size). Encase all water lines within 10' of septic transport lines and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system. 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14. No vehicular traffic over drainfield area or tanks. 15. Inspect floats, clean filters, and test high water level alarm every 6-12 months as needed. 16. All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19. All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8" hole drilled in the discharge pipe above the pump to prevent siphoning. Ensure anti-siphon hole sprays down/away from tank opening. 20. All transport lines under driveways or parking areas must be encased to prevent crushing. 21. Homeowner is responsible for all property lines and easements. 22. Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation & Maintenance on your NuWater pretreatment system.