Loading...
HomeMy WebLinkAboutFIR2023-00027 - FIR Plot / Site Plans - 11/5/20241 ELEVATION EN-TAltia DK& ;>OIZESEB510 StE oes*Rncrio^ 162 LESS THAN 1• - 0' f304.8mmj r'-o" (304.8, TO LESS TlNN r'-r (r57.2mmj 1 =b' (4572m.* 70 LESS N AN 2`-0" (609,6 j 1'-0" (609.6mm TO LESS TRAM 2`-0 [76ZOmmj 2'-6" 176201n.T1 TO LESS TMN J'-0' r9N.Omrr,J 3'-0- s!s.Om, i TO LESS TN2N 3'-E^ (1016.0mmj 3'-E" (T016.Ommj TO LESS N.4 <'_0" ('2 92mm; (12f9.O.mmj TO LESS ?MN f-6- (1371.6mmi C-s" ft37Lbmmj TO LESS TAN 5`-0' (1514.0 J 5`-0- (7524.0mmJ TO LESS TON, 5'-6' (IE7B.rmrj f1676.4mmj TO [EIS ION 6'-0" (T8288m17-j 6`-5' (1828.8mmj TO LESS OIM4 6'-r f 98T2nvn7 6'-6' ('9812rTmj TO LOOS THAN 7'-O' [2133. »mj r-o (2133.6nrnJ M61 ;,,,TER. Mama* dLLQf6SF ➢5idtlf 00 oErc= dirt& 13Q1TOM SE !ate to e' o' 28mmJ :_8.6mmj • 6mm' i<OTTZTA 140F002 OBSTRUCTION A 2 (D-8")+B A 2 (D-203mm)+B A D S 30" D 5 762mm TO SYSTEM 99 DRAIN WATERFLOW INFO STATIC: 60 PSI RESIDUAL: 55 PSI FLOW: 35 GPM ELEVATION: - RISER DETAIL i'J 1" SUPPLY BY OTHERS 1" ADAPTER 0 1" CONTROL VALVE 1" RESIDENTIAL RISER O SPARE HEAD BOX fl £fit tcs - s,i71/ ///F� 271 .1 GI/7 c- t�ul� G� /�� ��r=-� '`,s/'"f X/ e.ietyy DESIGN NOTES: 1. CASCADIA FIRE PROTECTION TO DESIGN AND INSTALLA NEW MULTI -PURPOSE FIRE SPRINKLER SYSTEM BASED ON NFPA#13D - 2016 EDITION, MASON COUNTY, AND THE FIRE SPRINKLER MANUFACTURER'S REQUIREMENTS. DESIGN DENSITY IS .05 GPM WITH TWO FIRE SPRINKLERS FLOWINGANDA MAXIMUM SPACING OF 14' x 14' WITH A MAXIMUM DISTANCE OF 7'-0" FROM WALLS PER MANUFACTURER'S REQUIREMENTS. 2. FIRE SPRINKLERS ARE NOT REQUIRED IN BATHROOMS 55 SQ FTAND LESS. 3. FIRE SPRINKLERS ARE NOT REQUIRED IN CLOSETS WHERE NFPA 13D REQUIREMENTS ARE MET. 4. ALL FIRE SPRINKLER PIPE AND FITTINGS SHALL BE LISTED CPVC. 5. BUCKETTESTAND HYDROSTATIC INSPECTION TO BE PERFORMED AFTER PIPE INSTALLATION. 6. PIPE HANGERS AND SEISMIC BRACING TO BE INSTALLED PER NFPA 13D. 7. AUXILIARY DRAINS TO BE INSTALLED AT LOW POINTS. 8. CASCADIA FIRE PROTECTION IS NOT RESPONSIBLE FOR PAINTING OR WIRING. 9. OWNER IS RESPONSIBLE FOR MAINTAINING TEMPERATURES ABOVE 40 DEGREES TO AVOID FREEZING. 10. NEW RESIDENCE IS CONSTRUCTED WITH COMBUSTIBLE MATERIALS. 1 F£R-BIG MOOED TRIES • 24' CC. BEE FL_N ROOF 54 TG - SEE NCTES R--49 EhTT. 'NB& I 0 G B. I f.. FIN'5N SECTION VIEW MAIN FLOOR PLAN 1/4" = 1-0" 1" CPVC PIPE - SEE INSULATION DETAIL FP-01 1/4" = 1'-0" e-- 0 tV /1 1'-6 Caution: For areas having temperature of 0°F (-18C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used. If this is not done, freeze -ups can occur in the sprinkler piping. INSULATION DETAIL SITTING Benson Residence Remote Area: Kitchen / Living CALCULATION DESIGN CRITERIA: STANDARD NFPA #13D-2016 OCCUPANCY CLASS Residential MAX. COVERAGE per HEAD 196 Ft' DENSITY .05 GPM / Ft' for 2 Sprinklers Ft' SPRINKLER Reliable Model RFC30 ORIFICE 1/2" K= 3.0 AW(ATER FLOW INFORMATION': YtlELLSTATIC 60 PSI RESIDUAL 55 PSI FLOW 35 GPM AT BASE OF RISER. SYSTEM REQUIRES: 20.08 GPM@ 48.44 PSI *At time of Design SITE PLAN NTS Cascadia FIRE PROTECTION PO BOX 206 PUYALLUP, WA98371 PHONE: (253) 202-3909 WA LICENSE NUMBER #CASCAFP833L2 www.cascadiafirepro.com a MODEL I RELIABLE RFC30 CONCEALER RELIABLE RFC49 CONCEALER SHEET TOTAL z Z LL I WHITE u.i - Z - ID cc (O (7, re W I- CD N- N Y o M rn .41: W IV F� - N - N (SYMBOL • 1 APPROVALS MASON COUNTY: OWNER: ARCHITECT: GENERAL CONTRACTOR: OTHER: REVISIONS trWNER: 4/0224 -5O-- 0/0/e J r NORTH SCALE: 1/4" = 1 2 4 8 NICET SEAL WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Michael Paul Agner II 43440218-C Level 3 Cascadia Fire Protection, LLC CASCAFP833L2 Signature 1 /ROJECT. PLAN: BENSON RESIDENCE 24520 N HWY 101 HOODS PORT, WA 98548 FIRE PROTECTION PLAN DRAWN BY: MA l DATE: 8-22-23 1 J JOB NO. CASCA23-1180 rSHEET 1 OF 1 FP-01