HomeMy WebLinkAboutBLD2025-00983 - BLD CD Environmental Health Review - 9/22/2025 ....._ 61, 100,26--")67c5 3
PLN Approved RR5 STANDARD SETBACKS*
09/22/2025 \C-CV
Front Yard Setback: 25'
Communityt
Mason County Development �``'' ! Side& Rear Yard Setbacks: Residential
</(. J(44 -+6
All Changes Subject to Approval ��\ _ ....
dwellings)/accessory structure(s) is 20'
.� OR 10%width of lot if not more than 100'wide
Disclaimer / OR approved ADV
Mason County does not require surveys for /
building.As a result,site plans may not reflect 10' /.- I ADV2025-00100 Reduced
accurate data. It is the applicant's responsibility I to 1 0'
to comply with setback requirements. 3G
`SETBACKS ARE MEASURED FROM THE Ili
FURTHEST PROJECTION OF THE r(\\
STRUCTURE. N_ J —
SEPTIC TANK & FLOUT
PROPOSED HOME I ,� j ?0 ►.
I --'---, ry ,,. „-,. \\I
BUILDING SETBACKS ' '' �
FROM SEPTIC <��,/ % - -� '` EXISTING WALL
COMPONENTS ��
i ii i% zy i
i /i i.% -i .--- - ,
EXISTING TANK <� -•-, ;��!/: 7 1
FOR LOT 70 <,�!-i,�'-%' Per geo report, proposed
`-i i%%'i y SFR needs to be at least
Li%,i I 5' away from existing wall
EXISTING 3 BEDROOM I L I
DRAINFIELD FOR LOT 70 INSTALLED
e-
d 2 BEDROOM
Piji
DRAINFIELD
(1.--A I
1
of , ,
,of
I
N
- � EHSetbacks
A.) Drainfield/Reserve requires 10'setback from footing/foundations
B.)Septic tank(s)requires 5'setback from all footing/foundations
C.)No foundation/Perimeter Drains within 30ft,downgradient of
I1 Drainfield/Reserve area
J — — — — — — D.)No Cut Bank(s).(gteater than 5ft and over 45 degrees)within
_ _ 5 ft,down gradient of Drainfield/Reserve area
— — — — — — — — ` 1 E.)Use approved mitigation from section C1-9 of the department of
ecology's"Criteria For Sewage Works Design,"when sewer
RECORD transport lines are within 10ft of water supply lines.
u1L C 1J ORD DRAWING�`�V I V
I
I 0 1 ".3-:t,,,-
„..7::I 0
I
if,..,.44-1/0-,w.i,4�Y ,I ' ff `.
.>
APPROX. OHWM Y c F.OP.Et7rN MY5S[ :1/
,'
HAMMERSLY INLET I 1 tt^ r'c` ,fi'c IY�`3
E XPIfiES
I I
_ EH APPROVED
_ _ _ — — — — — , — Rhonda Thompson 09/22/2025
CUSTOMER: MITCH SHIRAZI SCALE I:30 I '
PIONEER DIGGING, INC. PARCEL#: 32021-41-00060 TEST HOLE I: TEST HOLE 2:
SEPTIC DESIGNS ADDRESS: XXX E PARKWAY BLVD 0-40 GLS 0-38 GLS
40+LMS 38+LMS
3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER: ROBERT I-I. PAYSSE ROOTS-40 ROOTS-38
OFFICE-360-426-1803 FAX-360-427-2353 DESIGN PAGE: ASBUILT
CA{c- - # 3 2-0 - 2 I -- 4 I -
4 / et-flae -our 5
\ ‘ Y•C-V\ -=-. 10
e•N
. ,
I .. ._, _..-.- •• -
..,
1.1.. \
___-----9'
\ ---
------
3 L\ ..
---" )..,c2,j,)'
..-- c ‘)
9 c
. • "ce..._-
S %
\
\
1 e--
I .
›.'("-iki6^?:/ ii---- .1-- ..' k\s \ ' '. '•
--_--- 1
...---
1 .... ._. .
-- ---- ---
i -43r--c•••
, _____c_77.,\. .,... •• _.__..-,
...:; • . • •
•••.....‘..... •
k D • "•••••-
. •
2._.0), ,....0„... \‘‘. .... 111 ---(-2-- --. ''''' • ...0.----- 1.41"' "'I- ..i.e . ;
. ‘,. . .00 14., ......
•
. ___—•,--ies- ho' 4
---
_ 4,--"--0---------...___ ------ 2 :
i\
KG-- _------4%-c •°`
- .00
-------
107*\:.... \
. : • ----COO .to,
--''''-'--- -..* -----.- ..!ii -••• .-. . •E
1 •
---------------0506,4,1"---
___,....--------- GO*---- , 'I./ • /'-''''-'
.........." .......--••- -...-----. 001*Illge--•w• •• ..................
..,..------""-' evielft,_..-----"-•-• 1 .
WON' .11.•r--• i
--'---------104. -.--------------- :
i ------ -":40_
'-7--'-.:---*C ----6.6'47;;
---..---------- 1111#
‘ .
i
. --- .....------ir
......... ..___
. ,
. . ,
......_
_•_---
.. .
..........--
. : . .
'i •
. 11
. . .
• .
1 .
, .
.•
.,
.. ,.: ..,
..._.... \ l I