HomeMy WebLinkAboutSWG2025-00201 - SWG Application / Design - 5/29/2025�rlr■Ir■r■r _ ..�� i
MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584
SHELTON:360-427-9670,EXT 400
1. BELFAIR:360-275-4467,EXT 400
Public Health & Human Services ELMA:360-482-5269,EXT400
FAX:360-427-7787
On-Site Sewage System Permit: SWG2025-00201
APPLICANT GRUBER JEFFREY L&JEANNIE Phone: 360-490-2408
Address: 2032 EXCELSIOR DR SE OLYMPIA. WA 98501
OWNER GRUBER JEFFREY L&JEANNIE Phone: 360-490-2408
Address: 2032 EXCELSIOR DR SE OLYMPIA, WA 98501
SEPTIC DESIGNER Paysse, Alex L Phone:
Address: 3083 E Mason Benson Rd GRAPEVIEW, WA 98546
SEPTIC INSTALLER TBD Phone:
Address: 123 XXX XX, XX. 00000
Site Address: 561 E Country Club Dr E
Primary Parcel Number: 321046000008
Upgrade: 3-bedroom NuWater BNR500 ATU pressure system with
Permit Description: subsurface drip drainfield
Permit Submitted Date: 05/29/2025
Permit Issued Date: 07/02/2025
Issued By: David Anderson
Current Permit Fees Paid: $555.00 (additional fees may be required upon installation of system).
Permit Expiration Date: 06/30/2028 (based on date of inspection)
Permit Conditions:
1 Proposed development subject to zoning requirements and approval by the planning
department staff per Mason County Title 17.
2 Permit must be installed by a Mason County Certified Installer unless prior written
authorization from Mason County is obtained.
3 Drain field installation not to exceed designed upslope and downslope depth specified on
design form.
4 Installer is responsible for obtaining Mason County installation approval prior to backfill of
system components.
5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to
backfill of system components.
6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for
final installation approval.
THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS.
PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS.
THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED.
FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES.
For Final Inspection visit: masoncountywa.gov/health/environmental/onsite/oss-inspection-request.php or call:
360-427-9670, extension 400.
OFFICIAL USE ONLY
A •‘' MASON COUNTY DATE RECEIVED 0. _ - 2q- 2 )t
c Cl)
)k (,) ›
f1 AMOUNT RECENED;,66� RECEIVED RY. CO CA
m
1 Public Health & Human Services 11(■� Cl,
Environmental Health 360-427-9670,ext.400 or 360-275-4467,ext.400 C 0
415 N.6th Street •Shelton,WA 98584 S W G 20Z/ — CO2.O I O xi
Z Cl)
ON-SITE SE '► SYSTEM APPLICATION D >
c---__ m n
APPLICANT PHONE m
JEFFREY GRUBER 360-490-2408 z
c
MAILING ADDRESS-STREET.CITY.STATE,ZIP CODE 0 g
C:Z2032 EXCELSIOR DR SE OLYMPIA WA 98501 m
73
SITE ADDRESS-STREET.CITY,ZIP CODE C/ '.
%-I 581 COUNTRY CLUB DR e�('/ !Q UNION WA 98592 �"'
NAME OF DESIGNER `/ •C • PHONE IN)
ALEX L. PAYSSE cJ 360-507-1546
NAME OF INSTALLER WO PHONE I
v
TBD
PERMIT MIT TYPE(select one) DRINKING WATER SOURCE to I O
IVt RESIDENTIAL OSS COMMUNITY OSS i(1 COMMERCIAL OSS I5 PRIVATE INDIVIDUAL WELL S PRIVATE TWO-PARTY WELL Z I -r.
TYPE
pu OF WORK(select one) yp PUBLIC WATER SYSTEM ALDERBROOK
NEW CONSTRUCTION/UPGRADES 1=1 REPAIR/REPLACEMENT OTHER DETAILS(select all that apply) 0 TABLE X REPAIR 16)
:s'
TTALS 0 SURFACING SEWAGE 0 EXISTING FAILURE 0 SHORELINE
pMI'
SUB
I§DESIGN FORM(REQUIRED) SEPTIC DESIGN(REQUIRED) BEDROOMS LOT SIZE WAS LOT CREATED AFTER 411/20257 0
5WAIVER(S)(IFAPPLICABLE) 3 0.32 0I
❑ YES 0 NO X I O
DIRECTIONS TO SITE AND SITE CONDITIONS (ex locked gate)
NORTH OUT BROCDALE AND ONTO MCCREAVY RD. FOLLOW TO ALDERBROOK, I O
RIGHT ON MANZANITA. TRAVEL THRU ALDERBROOK AND TURN LEFT ON FAIRWAY 1- I o
LANE. AT STOP SIGN TURN RIGHT ONTO COUNTRY CLUB DR. SITE IS ON LEFT, PDI o
SIGN POSTED. I o
SITE MUST BE FLAGGED FROM MAIN ROAD AND TEST HOLES MUST BE FLAGGED WITH TEST HOLE NUMBERS. I
OFFICIAL USE ONLY BELOW THIS LINE ---
UPGRADE/FAILURE SOURCE(for reporting purposes)
1 ❑VOLUNTARY 0 MAINTENANCE/PUMPING ❑BUILDING PERMIT ❑HOME SALE CI COMPLAINT ❑OTHER:
INSPECTOR SOIL LOGS 5 S 4 T J y;9 1611 1 ,r I PVC
fv�tmj COMMENTS/CONDITIONS
. Tffp,e-L.,�t Vc�uterrrpe 31 17 o VL C� �a> ^ 1
IV ut 73 mot ei l
-, N Z: d-vf" vci t Vh irij i I1,s.--:0- r T t 1 vtl t-i''cit S b ►a-
nit a f- t qr' -i l 1
Ttt3:o- 10 V6tYltac
14st a i Iv- Li frl
RECORD DRAWING AND INSTALLATION REPORT
SOIL CODES:
V=VERY G=GRAVELLY S=SAND L=LOAM Si=SILT C=CLAY E=EXTREMELY R=ROOTS REQUIRED FOR FINAL APPROVAL.
INSP TOR SIGNATURE DATE APPLICATION EXPIRATION DATE APPLICATI A PROVED/ISSUED BY DATE
67 V 201 f (750 ZS-
71oz ? 7(?(70
THIS FORM MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE Revised:4/14/2025
e
DESIGN FORM—PAGE ONE Assessor's Parcel Number: 3 2 1 0 4 — 6 0 — 0 0 0 0 8
A design will be reviewed when 3 copies of each of the following are submitted:
''Completed design form that has been signed and dated. '"Scaled layout sketch,including all applicable items on checklist.
"Scaled plot plan,including all applicable items on checklist. '"Cross-section sketch, including all applicable items on checklist.
This form may be scanned and available for .ublic view on the Mason Coun Web site.Maximum lager size: 11"X 17"
Permit Number: SWG 2o25 - 002 01 Designer's Name: ALEX PAYSSE
JEFFREY GRUBER Designer's Phone Number: 360-507-1546
Applicant's Name:
Mailing Address: 2032 EXCELSIOR DR SE Designer's Address: 3083 E MASON BENSON RD
OLYMPIA WA 98501 City State Zip GRAPEVIEW WA 98546
City State Zip Designer's Email ap4pioneer@yahoo.com
DESIGN PARAMETERS
Treatment Device
❑Glendon 0 Sand Filter 0 Mound 0 Sand Lined Drainfield 0 Recirculating Filter 0 ATU NUWATER LJ Other
�
Treatment Level(check all that apply): ❑A 0 B 0 C 0 BLI l►7�BLr2 ❑BL3 O E D N
Drainfield Type
❑Gravity 0 Pressure 0 Trench 0 Bed 11 Sub Surface Drip
i Septic Tank/Drainfield Specifications Laterals
Number of Bedrooms 360 . Schedule/Class NETAFIM
1 Daily Flow: Operating Capacity 270 gpd Length 90 ft
Daily Flow: Design Flow 360 - gpd Diameter 1/2 in
Septic Tank Capacity(working) BNR 500 • gal Number 5
Receiving Soil Type(1-6) 3 . Separation 1.5 OC ft
Receiving Soil Appl.Rate 0.8 gpd/ft2 Orifices
Required Primary Area 450 ft2 Total Number of Orifices 450 EMITTERS
Designed Primary Area 675 ft2 Diameter .42 GPH in
Designed Reserve Area 675 ft2 Spacing 12 in
Trench/Bed Width 15 ft , Manifold
Trench/Bed Length 45 ft , Schedule/Class SCH.40
Elevation Measurements Length 15 ft
Original Drainfield Area Slope 2 % . Diameter 1 in
New Slope,If Altered 2 % Preferred manifold configuration used? 0 Yes 0 No
Depth of Excavation Up-slope 6-7 in Transport Pipe z
from Original Grade Down-slope 6-7 in Schedule/Class SCH.40
Designed Vertical Separation 12+ in Length <20 ft
Gravel-based Drainfield Required? 0 Yes 0 No ✓ - Diameter 1 in
Pump Required? g Yes 0 No Dosing and Pump Chamber
Pump/Siphon Specifications Number of doses/day 12 /
Diff. in Elevation Between Pump&Uppermost Orifice 7 ft Dose quantity 30 gal
Drainfield Squirt Height/Selected Residual(head) NA ft Chamber Capacity(flood) 1500 gal
Uppermost Orifice el Higher 0 Lower than Pump Shutoff Pump controls: Please check those required.
Capacity @ Total Pressure Head 11.2 gpm. Di Timer g Elapse Meter Ig Event Counter
' Calculated Total Pressure Head 89.9 ft If Timer: Pump on 10 MIN ,Pump off 1.8 HRS
Comments
Revised:4/14/2025
3
I
DESIGN FORM—PAGE TWO Assessor's Parcel Number:3 2 1 0 4 — 6 0 -- 0 0 0 0 8
Permit Number: SWG
DESIGN CHECKLISTS
Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch
10 Test hole locations Gd Drainfield orientation and layout Reference depth from original grade:
I Soil logs g Trench/bed dimensions and g Septic tank
Pi Property lines critical distances within layout g Drainfield cover
6I Existing and proposed wells g D-Box/Valve box locations Reference depth from original grade
within 100 ft of property [id Septic tank/pump chamber and restrictive strata:
0 Measurements to cuts,banks,and locations
gf Laterals,trench bed,top and
surface water and critical areas [21 Observation port location bottom
611 Location and orientation of 621 Clean-out location 0 Curtain drain collector
curtain drain and all absorption g Manifold placement 0 Sand augmentation
components g Orifice placement Other cross-section detail:
g Location and dimension of g Lateral placement with distance l Observation ports/clean-outs
primary system and reserve area to edge of bed
g Other Information
1 Buildings Audible/visual alarm referenced Yes No
6Zi Direction of slope indicator l Scale of drawing shown on scale g 0 Design staked out
g Waterlines bar 0 M Recorded Notices attached
61 Roads,easements,driveways, Cl Elevation benchmark and relative 0 g Waiver(s)attached
parking elevations of system components 121 0 Pump curve attached
61 North arrow and scale drawing 0 Il'Evaluation of failure
shown on scale bar Non-residential justification
❑ iI Waste strength
❑ l Flow
DESIGN APPROVAL
The undersigned designer must e otifi installer at time of installation g Yes 0 No
s_A,
z,_
Signat re of Designer ate
The undersigned has reviewed this design on behalf of Mason County Public Health and determined e ll ,,r,m,,,,
compliance with state and local on-site gulations:
7(2 70ef ,fAS JUL 0 2 ^5
En i onme al Health Specialist Date N�°AtryEh,
/fi, ,''''VITAL 1;?-
CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDQ IEbN:
✓ The design is stamped"Approved" by Mason County Public Health.✓ ��ie 7z0 ?�
The Onsite Sewage Permit has not expired,the Permit Expiration Date is:
✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval.
Please Note: The system must be installed by a certified installer,
unless prior authorization is obtained from Mason County Public Health.
An Installation Fee is required.
This form may be scanned and available for public view on the Mason County Web site. Revised:4/14/2025
7 LARGE FIR TREE
100% RESERVE AREA
(675 SOFT)
L......
NUWATER & PUMP I CO 0 0 1
TANK LOCATION -- --_ 00 I
N_..
_________.
�1;ii . ,_ .. , 1
PROPOSED 3 BEDROOM
r.
OPTIONAL I • - DRAIN FIELD (675 SOFT)
RECONFIGURED PATIO I SUB-SURFACE DRIPFIELD
OUTLET OF HOME
4"3034 SEWER LINE EXISTING HOME
I
I L. I
EXISTING TANK & I INSTALL 4"SWEEPING
DRAINFIELD: PUMPED & I /
CLEANOUT BETWEEN
ABANDONED PER CODE TANKS & HOME OUTLET
II
I ' I
1 ote 7, I
PRESUMED WATERLINE
LOCATION. IF CROSSED
W/ SEWER LINE, SLEEVE I
& INSTALL PER PIPELINE I 1
SEPARATION GUIDELINES 411 >
L
i ff
__.... .... _______. .... • .+f
APpRovED
►� '0S
E COUNTRY �� ..: +Ito
JUL O 2 CLUB DRIVE E
2025 ,y�' ,
f
`j'��"+�IyCt3UIVi'YENvIr �_ E.ULOI.Prs •5E +1
G.r,r�ChlAL HEALTH 1•' 'I 1 N `„
DJA
1 Yy,..
N AN ASBUILT/INSTALL SIGNOFF FEE WILL
BE CHARGED AT TIME OF INSTALLATION
.l1 I��I\1LIZ: �(�� TEST HOLE I: TE T HOLE 2 TEST HOLE 3: TL.�I HOLE 4&5:
PIONEER DIGGING, INC. PARCEL#:3 04' 8 20+11I.1;R-20 22+TILL/R-22 •}fir;1/R-9 0-18+1DU( H.I1
SEPTIC DESIGNS ADDREss: 581 COL[NTRY CLUB DR •�,T till-NKr)
DESIGNER: ALEX L PAYSSE OISCWMER:THIS IS NOT A SURVEY. REFERENCES INCLUDE APP{ICANTMAUNTY PROVIDED
3083 E.MASON BENSON RD. GRAI'EVIEW,WA 98596 PLATS OR SURVEYS.FIELD MEASUREMENTS ANDCOLAV Y GIS DESIGN INTENDED FOR SEPTIC
OFFICE-361.}4261803 FAX-360-427-2353ry vEPAH ME ONLY PROPOSED DEVELOPMENT MAY 6E SU&IECT ROE
o OTHER
�I I I f.T: SITE PLAN SCALE r=�V SEPTIC COMPONENCY RENEW DES GNER NOT RESPONSIDLE FOR SETFw VS UNREIATEO TO
SEPTIC CgMPONENf$
.[
(.,„:
100% RESERVE AREA
(675 SQFT)
I --i-,
O
1 j__
1
A
67'-6" I
NUWATER & 1500 GAL. PROPOSED 3 BEDROOM
I PUMP TANK DRAINFIELD (675 SOFT)
I SUBSURFACE DRIPFIELD:
H EADWORKS 450 LN FT/ 450 EMITTERS
1" SCH. 40 (TYP) 1.5 ON CENTER/ 5 LATS
I 0 wv
I 0 fil 0 '- n_S\,
5 — rearaiiiii
I O p UiiTh , 111
AMU
I 0 45 0
AIR/VAC
I RELIEF (X2) 0
TOP OF t--
' PATIO 6
I OPTIONAL
RECONFIGURED REMOVE PLANTINGS AS
OUTLET OF HOME NEEDED, BE CONSCIOUS ..
OF FUTURE ROOT •; : 'r
Y' �!�
INSTALL 4"SWEEPING GROWTH % 2
I CLEANOVT BETWEEN APpR , .�' ►,,►,
, lt
i TANKS & HOME OUTLET °; i i .� ►
acme •
►
ALIEN LOUIS MIME
MASON p pN JUL �2 Zd25 f• •7 Apar sm_N . ►1
4"3034 SEWER LINE Nn'ENVlRpNm °� IIII
1 DJA ENTqL HEALTH AN ASBUILT/INSTALL SIGNOFF FEE WILL
I I I BE CHARGED AT TIME OF INSTALLATION
Lust J:ti1ER: JEFFREY GRLBER 1 I`I 1.-• I: 22 -: z: i I>i 1101.1 3: i I i i�011 �t 5:
PIONEER, DIGGING, INC. PARCEL silo�a0000s (1_ (l 1)11(;1101
6t1711/R20 22+I111/R?2 9+Ti[1/R9 l}I8+<1
SEP I lC DESIGNS ADDRESS: 581 COIAITRY CLUB DR (NOT urr�[s[.r;
I
3083 E MASON BENSON RD. GRAPEVIEVv',WA 98596 DESIGNER: AM(L PAYSSE MUMMER THIS. NOT A SURVEY.REFERENCES INCLUDE APPLICDESIGN
INTENDED FOR SEPTIC
PURPOSES ONLY PROPOSED DEVELOPMENT MAY BE SUBJECT TO OTHER
P
OFFICE-36l}426-1803 FAX-360-427-2353 SHEET: DF DETAIL SCALE =10f DEPARTMENTIAGENCY RENEW.DESIGNER NOT RESPONSIBLE FOR SETBACKS UNRELATED TO
SEPTIC COMPONENTS
PRIPLINE —\
6"-8" INSTALL
DEPTH
0 0
��!\�!\�!\�!\�1��!\�!\�!\�!\�!V j\\!\\'\\'\\!\�!\\!��!\�!\�!V
\��\\���\���\��Q���\���\���\���\��\\���\���4 \\��\\����\\��\\��\\�����\�����Q��\
�����\��\��\��> .j4�j�\�����\����\���•���j� �\\.\- ••••• / FLEX TUBING
(r.,==. 0 0
0 0
DRIPLINE
\--
1 SCH. 40
6" ICV BOX TO AIR/VAC
FIN. GRADE ---\ RELIEF VALVE OH D Fowler Company
Continuous Flush Headwork
Quality Performance, Long-Life and
Reliable Onsite Effluent Control
Applications: 3. .;
leMIMIEMEM . • Onsite wastewater drip dispersal systems F„h'
Reuse applications including municipally
treated effluent designated for Irrigation and `/
br�• rlin' P • other disinfected and non-disinfected water
��4,4001� ����{..�.�� , sources ,i..
*S -{iyr{�:�* • • In a treatment system such as an ',Jr'.,4444�+./r{<:��0� ���I�+ nterm ttent sand fi11er or mound system ED' 1.1 'rJw.
,. {� ��{ ��I�:I�{•i..: Rainwater harvesting systems
� •.
t�:���{0iI�M{ tip./�Z�: • Greywater systems
i�.{��� {ti{.;��{� .:�M{��.�.: • Wherever effective removal of debris is
�� required
t :�L� �����•iy�I•{!�i�/ ▪ Typically installed downstream of treatment ,yam
process when used with onsite effluent
• Can be used with domestic strength septic ....
tank effluent with proper design and ar
operation The PUHEADWORKS4 Comes
, Standard in a 24"Riser
/arT
',�
i
/n S_1
r�� ` ` • •,�•�',+�� JUL 0 2 2025 TM
�_�: _ NETAFIM
•
•,. i NMENT ��"
y sumo e MAsocl c0U!:n ENviJP GROW MORE WITH LESS
•
ALE II LOU P*V5 C,!A
AN ASBUILT/INSTALL SIGNOFF FEE WILL
BE CHARGED AT TIME OF INSTALLATION
CUSTOMER: 04-60-JEFFREY GRUBER I'FST IIOIF.k TEST HOLE 2 TEST I TOLE 3: TEST HOLE 4&5:
PARCEL# 32104-60-00008 o-zo<l: 22+as u, 'I i1 vD DUG 1101.1
PIONEER DIGGING, INC _0+T111,R-20 22+Mt/R� „wR� I ��:
SEPTIC DESIGNS _Il ADDRESS: 581 COUNTRY CLUB DR (NOT SUITABl E)
3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGN-R: ALEX L PAYSSE DISC Liu/AM THIS IS NOT A SURVEY.REFERENCES INCLUDE APPLICANT/COUNTY PROVIDED
PATS OR SURVEYS,FIELD MEASUREMENTS AND COUNTY GIS.DESIGN INTENDED FOR SEPTIC
OFFICE 36(}4261803 FAX 360 427 2353 PURPOSES ONLY PROPOSED OEVELOPMENT MAY BE SUBJECT TO OTHER
DEPARTMENT/AGENCY MENT/AGENCY REVIEW DESIGNER NOT RESPONSIE E FOR SETBACKS UNRELATED TO
HEFT: DRIP DETAILS SCALE NA SEPTIC COMPONENTS
DUAL PORT AERATOR
4'CLEANOUT3 FT• /S LID VENT �D�Ip WTIHNNER CARTFICIALOMMENDS I ROCK LOR NOVSINLING AIR C ERABOVEGRA"vE
FROM FOVNOAT: 2.'CAST IN RISER W/ /
WATERTIGHT LID AND SCREWS
-IttP)1 _ Q- 1/41v1/2'PVC AIRLINE
45.
SANITARY TEL TT— '�T7 •� "T- �MATTIC
' COVPLIKfNG 1 t 1
• R� �F I \ ■ - 2'kREDI • 1 l
I N.E L:� - 1 ::?LET TO DRAINFIELD
r U.
WATER TIGHT— •
•/ (--, \
FLE(IBLEFITNG TEE , `WATERTIGHT
'. �� FLEXIBLE FITNG
1
DIGESTER C^.ti•19:c
?VC OPERATIN..
FLOODC A.. .
TANKS MUST BE TRASH CHAMBER
y. OPERATING CAPACITY 463 GA.
FIOODCAPACITY SOSCALLONs
ON STATE DOH ;
.i
APPROVED LIST NUWATER MR 500 `•' -
OF SEWAGE
TANKS • o •o • 9 ...,
•• DI}FUSER BARS a) •
.. O PARALLEL TO TANK WALL
PUMP TANKS OVER 0 SwccERE .I•
1000 GAL. REQUIRES • o 4 • USE RUBBER
TWO ACCESS RISERS GROMETS FOR
%•'•• • • *• • TRANSPORT LINE
TO GRADE • .. .
�• . • • ' AND ELECTRICAL
ON RISERS. MAKE
PUMP TANKS SURE ALL HOLES
LOCATED AT HIGHER ARE WATER-TIGHT
ELEVATION THAN NUWATER CONTROL PANEL
DRAINFIELD MUST I 24"RIBBED RISERS
HAVE ANTI-SIPHON l r IN/WATER TIGHT LIDS
DEVICE INSTALLED. i
T l , i FINISHED GRADE
ELF:'Ps':'AL WORK DONE 6
� F. �`1,ED ELECTntOAN TRANSPORT LINE
-a— Tm
-":------ RUN DRIP RETURN
'• rIl
LINE INTO PUMP
•I. TANK RISER
INLET
APPitfc V
UNION & BALL VALVE
_ ' d'
LLONWATERT/GHT CHECK VALVE
WATER-TIGHT 1500 GA
)OI NTS CONCRL/.PUMP TANK
JUL 0 . 2.025 (28.5 GAL. /IN.)
MASON COUNTY ENV', y MENTAL HE;LThH IGH WATER FLOAT FLO-I N DUCER
II DJ
'• �' ON/OFF FLOAT a t USE TANKS FITTED
in IL :' W/CAST IN WATER
���•�!" ,� J _/ /� ^ TIGHT FITTINGS FOR
• f� • PUMP: ORENCO PF_2010
'i ` i �# '� (OR — INLET/OUTLESAND
�1�'. CAST IN RISER
:Ea i,aexs �' t. .;: _ _ '•`•:%.'.:•. . : : - _ .. _ .., .. . ADAPTERS TO
yr AIEI Roue PJ1rssE f ENSURE WATER
fw' ' 1 N TIGHTNESS
CUSTOMER: JEFFREY GRUBER SCALE:NA
PIONEER DIGGING, INC. PARCEL#:32104-60-00008 INSTALL TANKS ON ORIGINAL OR
SEP I IC DESIGNS ADDRESS: 581 COUNTRY CLUB DR COMPACTED LEVEL SOILS. RUN CROSS
3083 E MASON BENSON RD. GRAPEVIEW,WA 98540 DESIGNER: ALEX L.PAYSSE CONNECTIONS INTO ORIGINAL SOILS TO
OFTICF-360-426-I803 FAX-360-427-2353 DESIGN PAGE TANKS DETAIL AVOID SETTLING.
400 1 i t ( 1 1 Orenco Technical Data Sheet
PF20 series,60 Hz.0.5-1.5 hp PF-Series Submersible Effluent Pumps:
350 IP S _ - ._ _ _ ---- T. _• 1-Phase,60-Hz,4-inch (100-mm)
win 7 4,pHcations Features/Specifications
,tit t ; roue Sores a rot Orb emu:Amon*lOcal P.nos en• -........ ........ s,,... .:.vrMmbnop
,` a�ie7 m Minotdamn fmT en RS muta In •Mrnun 2+tiu,nn dryy toes ern wet ra On..J
Y Isli t coot tans a mvq tans Pete nose are cawul,a d e. a Ron Mt a peA am•
[ .. _.- .I. re ki tmoeali tCma,worn.
neyt rbn am mpU.t petals.aM •le H 3 esrO trans atavism. rarmtu:a:N raw
C • Pfaiti I a rr nus a6•emmm.n s l� om,k,
Sla U.cenbm al US all Uukw:swan sew.,kr M. Wb;Meta,WO
lour. ee�m as relate n tide. 1mn cost el newt*
r� •1e sue..-Aola node often m 1020.a1300;e 06.13
�- •n .. II Na.. I f'Srna;mis a,>�b a rarity a atpuitrm araary arna aN e 9 t.vro rmMs soanN shad.6eaT m Saw 15 min r3.a
ca aaAObe taade0 no taws crumb amen tits.Meerr m
co
awn to.o ary OW*sewer,wearM:pcou aN inure These :d t7 rota nmw
�� IIIIIILII1II1
• eon.abanornaaaa.x..43 eari4rr remra tn. b0014*WWI 300 V
•ilia S70W It001 order cable Int.l M 25f St2 uses Ia AY.1:
SJOOY4 700 Y cad
-Owc`erp.Tn..�,
■ 111111111111
, �. Standard Mode'
▪E 150
et
--- .a a s�wr4 wtcs k."� 1111111111n111
II
+ ProductC' ,1+
kn.amr PF !iT• • .11
az• '°° u T�'r5Zio . �-r
1 • n 1 . •yr�r50 �
` i;,fit, ' Ioi
I I i `? Name A..�1 y
0 5 1'0 15 20 25 30 35 40 ""` f" f I ours v�rssF 1,
•
Flow in gallons per minute (gpm) I-;yenta,.
System Data Input Calculation Outputs
Galons Per Day 360 Total System Information
Application Area Requred(square Peer) 675
Sod Loading Rale(Gallons!Sq.Ft./Per Day Pep; 0.533 Total Amount of Bwkne°Required(feel) 450
Total Number of Emitters in the Ddpfiek 450
Select Emitter Flow Rate(GPI-6' 0.42
Zone Information
Select Emitter Spacing(inches) 12 Number of Zones 1
Amount of&cline°Per Zone(feet 450
Flush Vebcily(fps). 2 Number of Emitters Per Zone 450
MI tmun Number of Laterals Per Zone 2
Assum•tiOnS Maximum Number of Laterals Per Zone 6 �Q
Estimated Pump Flow Rating(GPM) 12.1 Number of Laterals That WO be Used it, 6 aA
Maximum Length of Biotin°Laterals Based on hlet Pressure 221
hlet Pressaae(psi) 26 Flow Rate Per Zone(GPM): 3.2
Holding Capacity of Dnppenme Per Zone(Gallons) 6.0
Intel Pressure(Feet of Head) 57.8 Additional Flow Requirement to Accommodate Flushing Velocity 8.0
Row Spacing Between Dnpkrres(lee; 15 Holding Capacity of Piping
Holding Capacity(Gallons)of Supply Line&Supply&Flush Manifolds 1.3
Number of Zones 1 Holding Capacity(Gallons per Zone)of Blaine. 6.0
Holding Capacity(Gallons)of Supply Line Manifolds and Dnpperine 7.3
Hoes Per Day to Use for Dosing.. 24
Head Loss Data-Dosing&Flushing Cycle
Elevation Change horn Pump to Dose Tank Outlet(feet) 5 Friction Loss per 100(psi)in Supply Line&Manifolds 2.9
•
Velocity dy 4.1
Elevation Change from Dose Tank to Dnp Field(fee; 2 Friction Loss in Sappy Line&Supply Manifolds(psi) 0.9
Friction Loss in Suppy Line&Supply Manifolds(Feet of Headj 2.0
Length of Supply Line&Supply&Flush Manfolds(lent) 30 Additional Pressure Required for Return Marifokf and Piping to Tank(psi) .=10.0 1
Additional Pressure Required for Return Manfold and Piping to Tank(Feet of Head) 23.1
TDH(Total Dyrankc Head)in Feet of Head 69.9
Type of Pipe-Suppy Line&Manifolds PVC Sch40 Control Settings Information
Total System Runtime Per Day(Mimes? 114
Size of Supply&Manifold Pipe(indresj 1 Total Runtime Per Zone Per Day(Mimes) 114
/. . - _ _ Total System Dosing Everts Per Day, 12
Pipe Roughness Constant t 160_ J, r'e'b 7Th Runtime For Each Dose(Mimes) 10
``jr a t) }7 pp i Oft Time Between Doses m the Same Zone(Hours to nearest O t j 1.8
Inside Diameter of Pipe(inches) 1.049 `lull- 1s ���000
Miscellaneous Information
Number of Daily Dosing Ewes Per Zone l2 �II/A1rY1 ��1jOv Dosing Volume Per Emitter Per Dose(galbns: 0.07
J L 0 2 / '25 Inches Per Week of Dosing• 5.99
Volume of a Single Dose(gallons) 31.6
MASONCO.:. Pump Selection
-. -AL HEALTH Pump Flow Ratirg(GPM) 11.2
Save to File TDH(Total Dyran9C Head in Feet ofHeadj 99.9
LJ Pump Manufacture
niii
Pump Mode
PIONEER DIGGINC, INC. CUSTOMER: �G8UBEREL1
SEPTIC DESIGNS ADDRESS: 581 COUNTRY CLUB DR
3083 E MASON BENSON RD. GRAPEVIEW,WA 9)5* DESIGNER: ALEX L PAYSSE
OFFICE-360426-I803 FAX-360-427-2353 SI IFf r: CALCS SCALE NA
Installation & System Notes
1. Installer must contact designer for final inspection of the installation prior to cover. All components, including tanks, lids,
transport line, drainfield, and water lines must be open for inspection. A$350.00 fee will be charged for time involved with the
inspection of the installation and creation of the record drawing. The designer reserves the right to charge additional fees if
multiple visits are needed due to installation errors or inaccessible components.
2. This septic design must be installed by a certified installer with the local health department. All components shall be installed
according to state, county,and manufacturer requirements. For Homeowner Installs,the owner must get approval from the
designer and local health department prior to attempting installation.
3. Designer is not a surveyor. Installer must familiarize themselves with property line locations prior to installation. Any
confusion or conflicts with line locations should be reported to the property owner. A licensed surveyor may be necessary prior
to installation to confirm all line locations. Any discrepancies found must be reported to the designer immediately.
4. Drainfield area may only be cleared by a licensed installer familiar with sensitive drainfield area preservation. The builder, lot
developer,or property owner shall not clear the drainfield area. Any clearing required for drainfield installation shall not
remove or disturb any top soil in Primary and Reserve areas. Removal or disturbance to drainfield soils could render design
void.
5. The property owner and installer are responsible for locating all underground utilities (ex. water,gas, electric) prior to
installation. Any utility locations shown within design drawings are likely approximate and may not be exact.
6.All proposed tanks must be installed on original soils or compacted gravels. Extend all tank connection lines out onto original
soil to avoid settling issues. Risers and lids must be brought to finished grade and left accessible for future operations and
maintenance. Component manufacturers (ex. ATU, Glendons,) may have other requirements not listed within this design.
7.All electrical wiring shall be done by a licensed electrician or homeowner(if allowed)and must be permitted through Labor
and Industries. Designer not responsible for electrical permitting or other electrical specific code requirements.
8. The proposed septic system should be installed in dry weather conditions. Any failed attempts at installation during wet
weather conditions may render this design void.
9. Maintain loft to waterlines with all septic components. If less than 10ft is required, sleeving in sch. 40 pvc is required. If
sewage transport lines and waterlines must cross, waterline must be 18" above sewage line with one of the lines sleeved in sch.
40 pvc 10ft in each direction of crossing.
10. This design may include waiver applications with specific mitigation measures pertaining to installation,operation and
maintenance of the proposed components.
11. Stormwater runoff,footing drains, roof drains must be diverted away from any septic system components. No curtain,
foundation, perimeter drains shall be installed 30ft downslope and loft upslope of drainfield areas.
12. This design is site specific and intended to meet state and county requirements that are related to the system components
being proposed. Any placement of proposed buildings, proposed wells or other non-related items on these drawings may or
may not meet other requirements.
13. All onsite septic systems require regular maintenance to verify satisfactory operation. The system owner/operator is
responsible for the continuous operation and maintenance of the system per WAC 246-272A. For operation and maintenance
information, refer to Mason County Public Health Homeowner's Manual,which should be received after installation approval.
14. System owner should be cautious of landscaping around septic components. Root intrusion JUL 0 2 z025
can cause premature failure of the drainfield area. In addition, bushes and trees should b�`¢i31J'COUNTYENVIRO ';�
away from lids and other septic maintenance points. ."11
ENTAL HEALTH
15. Changes made at time of installation may impact designer calculations, pump sizing,and
•
compliance w/county and state requirements. Contact designer prior to install w/any �� ,
proposed variations from design. Changes may result in additional fees and permitting. 40 : •
gal:I O�`1LR: JEFFREY GR.UBER ,4�S' � +
PIONEER DICING, INC. '• �
PARCEL#:32104-60-00008 - •• V+
SEPTIC DESIGNS ADDRESS 581 COUNTRY CLUB DR , imam
t" ALEX LOUR NOW
3083 E MASON BENSON RD. GRAPEVIEW,WA 98546 DESIGNER: ALEX L PAYSSE
OFFICE-360 426-1803 FAX-360-427-2353 SHEET: NOTES SCALE NA