HomeMy WebLinkAboutSWG2025-00229 TANK ONLY - SWG Application / Design - 6/17/2025 MASON COUNTY 415 N 6TH STREET,SHELTON,WA 98584
J` SHELTON:360-427-9670,EXT 400
BELFAIR:360-275-4467,EXT 400
Public Health & Human Services ELMA:360-482-5269,EXT 400
FAX:360-427-7787
On-Site Sewage System Tank Only Permit: SWG2025-00229
OWNER ATKINSON RICHARD & MONICA Phone: 253-297-1342
Address: 300 NE HAVEN LAKE DR TAHUYA, WA 98588
APPLICANT ATKINSON, RICHARD Phone: 2532971342
Address: 300 NE Haven Lake Dr TAHUYA, WA 98588
SEPTIC INSTALLER JACK JOHNSON* Phone: 1.360.277.5400
Address: P O BOX 1119 BELFAIR, WA 98528
Site Address: 300 NE HAVEN LAKE DR
Primary Parcel Number: 223305000307
Permit Description: Add ejector pump and basin to pump 240' up to established gravity
system.
Permit Submitted Date: 06/17/2025
Permit Issued Date: 06/17/2025
Issued By: Rhonda Thompson
Current Permit Fees Paid: $270.00 (additional fees may be required upon installation of system).
Permit Expiration Date: 06/17/2028 (based on date of inspection)
Type of Work OSS New Construction
Components being Replaced: Pump Tank Only
Surfacing Sewage? No Existing Failure? No
Shoreline? No Horizontal Setbacks Met? Yes
Number of Bedrooms: 3 Drinking Water Source: Public Water System
Additional Details: Have existing gravity system, installing pump to reach that.
Permit Conditions:
1 Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is
obtained
3 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for
final installation approval.
4 Proposed development subject to zoning requirements and approval by the planning
department staff per Mason County Title 17.
2 Permit must be installed by a Mason County Certified Installer unless prior written
authorization from Mason County is obtained.
THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS.
PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS.
THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND/OR DESIGN
APPROVED.
FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES.
For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call:
360-427-9670, extension 400.
i
CV
\w
N/ ;ell
N
Q. a
cl
Q f? 3.5)' r1 1
d w o
s�
NI
' % 7 •
1
; o d4
\
. T , der
\F~-- ,5L/ `sr
10 .Y
5�
/ • L7Alef ar I JA---- e-‘r:():,
Ss... , g r ,�,'
<//,/
\ . Ai 1 .. . 4 C4.--3,s
\ \ , c) % - .:0.1
\ \,,
• •h\-31, I
�� 12 .
}r \ \
0.1`' 0( * . Pv '- \ • a
�°6�
wu.1 _30k,e ii /' Y il\ \ 744
\)
- i. ....N1
Ver. ,� S
"V--- \ ' ' J 1 '
\ \c\ 14 . ..
� .
- Al 1
Wiz- \ S\ �
M
Orenco Technical Data Sheet
W A T E F3
PVC Pump B asins EH APPROVED
Rhonda Thompson 06/17/2025
Applications Standard Models
Orenco PVC Pump Basins are designed to house effluent pumps, PB1854,PB2454
sewage pumps,or grinder pumps in wastewater pumping applications. (Custom basins are available for specific configurations.)
They are not IAPMO listed.
General Materials of Construction
Orenco PVC Pump Basins come in 18 and 24in (450 and 600mm) Ribbed pipe PVC
nominal diameters. Bases are fiberglass-reinforced polymer(FRP), Base FRP
attached with epoxy.EPDM grommets seal all piping penetrations.A Grommets EPDM
4in(100mm) inlet elbow and holes to accommodate splice boxes and
discharge piping are located and sized to specific need.Fiberglass
access lids and stainless steel fasteners are sold separately. Specifications
Optional equipment is available.
Model O.D.,including rib I.D. Liquid capacity
in(mm) in(mm) gal/in(Umm)
t PB18XX 19.44(494) 17.50(445) 1.06(0.16)
PB24XX 25.63(651) 23.50(597) 1.88(0.28)
• _ Product Code Diagram
- PB + + +
I Discharge assembly or grommet option:
HD = Pre-trilled for HDA125
• 1102 = Pre-Pilled la HDA200
- 10 = 1 in(25mm)grommet
_ 12 = 1 yin(32mm)grommet
15 = 114in(38mm)grommet
• 20 = 2in(51mm)grommet
Connector/splice box option:
_— CLK = Pre-trilled fa ClichTightr
S = tin(25mm)grommet installed
---_ -- L = lyin(32mm)grommet installed
S1 = SBt attached
_ S2 = S82attached
S3 = SB3 attached
---- S4 = 534 attached
L5 = SB5 attached
'F: - L6 = 586 attached
."
ice_
SX = Pre-installed hub for external splice box'
XS = Explosion-poet splice box for simplex pumpst
--------. XD = Explosion-pool splice box for duplex pumps'
f X1 = Explosion-proof splice box for triplex pumps'
Cleanout vent option:
Blank = No cleanout
COV - Cleanout vent inc.eded
.. ____—.--- Flow inducer option:
Blank = No flow inducer
Fl = Flow inducer included
Basin height:
_�' 54= 54in(1372mm)
L ------- 60= 60in(1524mm)
66= 66in(1676mm)
72= 72in(1829mm)
� - Basin dameter,nominal:
18= 18in(450mm)
24= 24in(600mm)
Pump basin,PVC
•Requires minimum 18in(457mm)riser height
24in(600mm)PB24XX PVC Pump Basin tFor Class I Division 1 environments
(Shown with optional cleanout and vent)
Orenco Systemsm•800-348-9843•+1 541-459-4449•www.orenco.com NTD-PB-PB-1
Rev.5 C 09/21
Page 1 of 1
EH APPROVED iF
Rhonda Thompson 06/17/2025 /illpk
• ® ,00,
llyLJber Pum s pV �
Pump Specifications ,,,
`�;;
I
LE50 Series
1/2 HP Submersible Sewage Pump
UTERS PER MINUTE
0 100 200 300 400 500 600
1 1 F 4 1 1
- 8
25
- 7
20 - 6
co
- 5i
w
1-
1- w
w
LL 15 - z
z o
o Q
w -- 4 =
Q
J <
Q Q
O ~
10 . . - - 3
- 2
5 '
- 1
0 0
0 20 40 60 80 100 120 140 160
GALLONS PER MINUTE
LESO_PI RI1/4/2011 UCopyrtght 2011 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. Iillgii
LE50-Series Dimensional Data
EH APPROVED
10.7" Rhonda Thompson 06/17/2025
8.4" [271mm
[213mm1 -'.ati,F- • IF 0 /
4101/ 444p
(4".:1°0 4\it Ai- //
0
v. N
r a E*
-t
Lv� \
2" NPT
CORDS -230V, OR 1 15V PIGGY BACK - AUTOMATIC VERSION
II- I _-
ii
E.1 C!
iIIIII►
13.25"
[337mm],A-1 Mk i �� i rfrilriM _____MMEM
�i
iiiiii
MNA
.W
M 11 [149.9] imp_ni a1J.j
lt
�i� t�Ir��il
'III
II
CWO ,,o
PROPMITMY ANDcoNnoENnM LE50 SERIES DIMENSIONAL
REE FIEORMATION CCHTAPEED N 016
DRAWING 61HE SOLE FROPERTY Of
<ISERTCONPANY NAVE HERE,.Ar1Y
REPRODUCTION N PART OR AS A WNO.E 3Vf NOVEMBER 14/2006 '
W ITHDUi ME WRITTEN PERr.YS ION Or A
<ESERiTED. N
INANE FERE>6
HBRE APPUCAIION DO 01 SCALE DRAWING
>ROO. SCAIEIS 1WE04:UllS ISMFR icy
LE5O_P2 RI 1/4/2011 OCopyright 2011 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 1thill
EH APPROVED
Rhonda Thompson 06/17/2025
LE50-Series Electrical Data
FULL LOCKED THERMAL STATOR CORD
MODEL HP VOLTAGE PHASE SF LOAD ROTOR OVERLOAD WINDING LENGTH DISCHARGE AUTOMATIC
AMPS AMPS TEMP CLASS FT
105'C
LE51A 1/2 115 1 1.00 12 22.5 221,E B 10 2" YES
105'C B 25 2" YES
LE51A-2 1/2 115 1 1.00 12 22.5 221°F
105'C 10 2" NO
LE51M 1/2 115 1 1.00 12 22.5 221°F B
105°C B 25 2^ NO
LE51M-2 1/2 115 1 1.00 12 22.5 221°F
105°C B 10 2^ YES
LE52A 1/2 208-230 1 1.00 6.8 12 221°F
105'C B 25 2^ YES
LE52A-2 1/2 208-230 1 1.00 6.8 12 221°F
105`C
LE52M 1/2 208-230 1 1.00 6.8 12 221°F B 10 2" NO
105'C
LE52M-2 1/2 208-230 1 1.00 6.8 12 221°F B 25 2" NO
LE50-Series Technical Data
il
2 VANE ENGINEERED
THERMOPLASTIC
ELASTOMER
IMPELLER 2"SOLIDS HANDLING
SOLIDS HANDLING SIZE 2'
PAINT POWDER COAT
MAX LIQUID TEMP 60•C 140'F
MAX STATOR TEMP 130'C 266'F
THERMAL OVERLOAD 105'C 221°F
POWER CORD TYPE SJTW
MOTOR HOUSING CLASS 25 CAST IRON
VOLUTE CLASS 25 CAST IRON
SHAFT STAINLESS
HARDWARE STAINLESS
ORINGS BUNA N
MECHANICAL SEAL UNITIZED CERAMIC CARBON
WEIGHT 43 LBS
LE50 P3 RI I/4/2011 CCopynght 2011 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice
EH APPROVED
Rhonda Thompson 06/17/2025
LE50-Series Specifications
1.01 GENERAL:
The contractor shall provide labor,material,equipment,and incidentals required to provide (QTY)centrifugal pumps as specified
herein.The pump models covered in this specification are Series LE50 single phase pumps.The pump furnished for this application shall
be model as manufactured by Liberty pumps.
2.01 OPERATING CONDITIONS:
Each submersible pump shall be rated at 1/2 hp volts,single phase,60 Hz. 1725 RPM.The unit shall produce G.P.M.at
feet of total dynamic head.
The submersible pump shall be capable of handling residential sewage with 2"solid handling capability.The submersible pump shall have
a shut-off head of 24 feet and a maximum flow of 141 GPM @ 5 feet of total dynamic head.
The pump shall be controlled with:
A piggy back style on/off float switch.
A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm.
A NEMA 1 indoor simplex control panel with three float switches and a high water alarm.
A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm.
A NEMA 1 indoor duplex control panel with three float switches and a high water alarm.
A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm.
A NEMA 1 indoor duplex control panel with four float switches and a high water alarm.
3.01 CONSTRUCTION:
Each centrifugal sewage pump shall be equal to the c us certified Series LE50 SERIES pumps as manufactured by Liberty Pumps,
Bergen NY.The castings shall be constructed of class 25 cast iron.The motor housing shall be oil filled to dissipate heat.Air filled motors
shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be rrachined and sealed
with a Buna-N o-ring.All fasteners exposed to the liquid shall be stainless steel.The motor shall be protected on the top side with sealed
cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord.The motor shall
be protected on the lower side with a unitized ceramic/carbon seal with stainless steel housings and spring.The pump shall be furnished
with stainless steel handle.
4.01 ELECTRICAL POWER CORD
The submersible pump shall be supplied with 10 or 25 feet of multiconductor power cord.It shall be cord type SJTW,capable of continued
exposure to the pumped liquid.The power cord shall be sized for the rated full load amps of the pump in accordance with the National
Electric Code.The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight
compression fitting cord plate assembly,with molded pins to conduct electricity.This will eliminate the ability of water to enter internally
through the cord,by means of a damaged or wicking cord.
LE5O_I'4 RI I'4,2011 °Copyright 2011 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. ithetfi
EH APPROVED
Rhonda Thompson 06/17/2025
5.01 MOTORS
Single phase motors shall be oil filled,permanent split capacitor,class B insulated NEMA B design,rated for contiruous duty. At
maximum load the winding temperature shall not exceed 130 degrees C unsubmerged.Since air filled motors are not capable of
dissipating heat they shall not be considered equal.The pump motor shall have an integral thermal overload switch in the windings for
protecting the motor.The capacitor circuit shall be mounted intemally in the pump.
6.01 BEARINGS AND SHAFT
An upper and lower ball bearing are required. Both bearings shall be permanently lubricated by the oil,which fills the motor housing.The
motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.50".
7.01 SEALS
The pump shall have a unitized carbon/ceramic seal with stainless steel housings and spring equal to Crane Type 6A.The motor plate/
housing interface shall be sealed with a Buna-N o-ring.
8.01 IMPELLER
The impeller shall be engineered thermoplastic elastomer,with pump out vanes on the back shroud to keep debris away from the seal
area. It shall be threaded to the motor shaft.
9.01 CONTROLS
All units can be supplied with CSA and UL approved automatic wide angle tilt float switches.The switches shall be equipped with piggy
back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes
inoperable. Manual Pumps are operable by means of a pump control panel.
10.01 PAINT
The exterior of the casting shall be protected with Powder Coat paint.
11.01 SUPPORT
The pump shall have cast iron support legs,enabling it to be a free standing unit.The legs will be high enough to allow 2"solids to enter
the volute.
12.01 SERVICEABILTY
Components required for the repair of the pump shall be shipped within a period of 24 hours.
LE50_P5 RI 1/4/2011 cCopy right 2011 Liberty Pumps Inc. All rights reserved Specifications subject to change without notice
13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE
Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile
grommets or o-rings. The Discharge piping shall be schedule 80 PVC and furnished with a check valve and PVC shut-off ball valve.The
Tank shall be wound fiberglass or roto-molded plastic.An inlet hub shall be provided with the fiberglass systems.
Stainless steel Guide Rail
Zinc plated steel Guide Rail
"diameter of basin size
"height of basin size
"distance from top of tank to discharge pipe outlet EH APPROVED
Fiberglass cover Rhonda Thompson 06/17/2025
Structural foam polymer cover
Steel cover
Simplex System with Outdoor panel and alarm
Duplex System with Outdoor panel and alarm
Simplex System with Indoor panel and alarm
Duplex System with Indoor panel and alarm
Separate Outdoor Alarm
Remote Outdoor Alarm
14.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity,moisture content
and insulation defects.The motor and volute housing shall be pressurized,and an air leak decay test is performed to ensure integrity of
the motor housing.The pump shall be run,voltage current monitored,and the tester checks for noise or other mal`unction.
15.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified Facility.
16.01 WARRANTY
Standard limited warranty shall be 3 years.
LE5O_P6 RI 1/4/2011 OCopynght 2011 Liberty Pumps Inc All rights reserved Specifications subject to change without notice. I