Loading...
HomeMy WebLinkAboutSWG2024-00474 - SWG As-Built - 5/7/2025 Mason County OSS Installation Report pg. 1 MASON COUNTY PUBLIC HEALTH APPLICANT! PERMIT INFORMATION Permit Number SWG 2024-00474 Parcel# 32227-22-00140 Applicant Name Tomas Webb Subdivision (Name/Div/Block/Lot) 4. Applicant Address PO Box 509 4Zt. 9` City, State, Zip Tahuya, Wa 98588 Installer Name Spear Const �'�-e `sf Site Address 14891 NE North Shore Rd. Designer Name Bob Paysse • p INSTALLATION CHECKLIST J Full System Installation ❑Tank(s)Only ❑ Drainfield Only 0 Repair ❑Other System Type ATU - Pressure Pretreatment Type NuWater BNR 500 >5 ft.from foundation? - - 0 N/A YES ❑ NO >50 ft.from wells? - - 0 ® 0 Z >50 ft.from surface water? - - 0 ® El H Cleanout between building and tank? - - 0 Elf ✓ Tank baffles present? - - 0 ® 0 d24"access risers over each compartment?- - 0 tl 0 tW Effluent filter installed?- - NI ] — o Septic tank capacity (working) NUWater qal Manufacturer Sound Placement 0 D-box water level and speed levelers used? - - alN/A ❑ YES ❑ NO oO Manifold/D-box accessible from surface?- - 0 ❑ DQ Check valves installed? - El v 2 Transport Line Size 2" Schedule/Class 40 'i Bedrooms installed (check one) D 2 0 3 0 4 0 5 ❑6 ❑CommerciaLOther >10 ft.from foundation? nj N/A YES ❑ NO G >100 ft.from wells?- - ❑ ,, ❑ W >10o ft.from surface water? - - 0 Li 0 Er_ >10 ft.from potable water lines?- - ❑ __A 0 _ > 5 ft.from property lines and easements?- - 0 0 ii >30 ft.from downgradient curtain/foundation drains? - - 0 i ❑ CI Drainfield level and observation ports present - - 0 00 i❑ 0 Graveless chambers or p Clean gravel used? (check one) Proper cover installed over drainfield?- - 0 „I !! Pump tank setbacks consistent with septic tank? - - [ N/A 1_ . YES 1: NO • Pump tank capacity(flood) 1500 gal Manufacturer Sound PIE 3ment Q 24"access riser(s)and accessi:;a from surface?- - 0 '7 LL H — O. Alarm or Control Panel Installed? ❑ 2 Control Panel equipped with Timer! ETM/Counter- - ❑ D a_ Pump installed in D Bucket cr ® On Block or 0 Other a. 2 Pump Make/Model Liberty 290 ® Floats or D Transducer d Tank draw down 2.5 in/min Pump capacity 75 qpm Squirt Height 36" ft Pump on time 50 seconds Pump off time 4 hrs Daily flow set at 36C gpd Updated 2/21/2018 Mason County OSS Installation Report pg. 2 Parcel# 32227-22-00140 ABANDONMENT RECORD Were existing septic components aband ned as part of this project? - • If yes, please describe: 0 YES NO Were all components pumped out and properly abandoned per WAC24&272A0- 300? - - ® YES 0 NO RECORD DRAWING This Is a Permanent record and must be accurate and descriptive enough to relocate In the need of maintenance activities and future development Typical Record I Drawings contain: Draintleld&manifold orientation&layout,Septirlpump tank location,North arrow,reserve drainneld,existing end proposed buildings.location of wells,waterlines webs,observation Pons,cieanouls,are other maintenance access points. Incomplete Record Drawings may create additional delays in final instsilation approval and related parmhs. it Record Drawing Attached CERTIFICATION OF INSTALLATION INSTALLER DESIGNER/ENGINEER !certify that 1 installed the system in accordance with'APPROVED'oy Mason 1 certify that the system ha; aeon installed i,; 3ccur the septic design stamped dance with the septic design stamped'APPIA VELD by County Public Health and that any devik. kids shown. Mason County Public Health and that any deviations here have been cleared/approved by both the designer shown here have been cleared/approved and Mason County Public Health and meet all State lthby both • myself and and Mason County Codes. Mason County Public Health and meet all I further certify that all information contained on this State and Mason County Codes 1 further certify that all information contained on this : ;: :RoTd Drat,rirg;s acule, form and attached Record Drawing is accu;aie. 2 ate Logan Spear r Printed Name of Signee — ec(io'w, • MASON COUNTY PUBLIC E ,AL-1 1-1 • e !_r • 70,ao irospRT The undersigned approves this Installation Report and Pokt.> Record Drawing on behalf of Mason County Public Health: c»>`es ILS Signature of Environmente r7ecu4•; Spoviar'ist Jac ...4116111111111 (stamp, signature and date) THIS FORM MAY BE SCANNED AND AVAILABLE FOF.PUBLIC VIEW ON THE MASON COUNTY WEB SITE updated 8/21l2o18 ° PUMP OUT&ABANDON ALL I NORTH SHORE RD EXISTING COMPONENTS. I ° o MAINTAIN 101+ FROM EXISTING I EXISTING WATERLINES TO NEW 055 WELL COMPONENTS I ;� 'T `/ SHOP/ GARAGE /.%..-%. " N CW/NO FOUNDATION) / , f/ EXISTING 055 / `\ /! Ef PUMP OUT N. \ / & ABANDON ♦Its_: ti REMOVE �.� `y� SPRUCE TREE I \� `` NI / illik \,../ DBL SLEEVE r';��� � \� / NEW2 SCH. 40 :\ \��,� / I _____TRNSPT. LINE I �`��\ \\�� PROPOSED / _ � (10+ EA. DIRECTION) I \\` DRAINFIELD / / \ • i —_ ,41---ik NEW 1 ; `e SHED TANKS . .. ° J ---7 APPROXIMATE E •'STING ABANDON in WATERLINE LOCATION EXIST. T/LINE `Rr / APPROVED EXISTING PUMP BASIN 1 PUMP OUT& i EXISTING / MAY 0 7 2025 ABANDON HOME MASON COUNTY ENVIRONMENTAL HEALTh RET / i SHORELINE/ / BULKHEAD 0. / .....r- : ,ut,;,f *� i HOOD CANAL 'C.'ar 4; EX�. LL5 / \ AN ASBUILT!INSTALL SIGNOFF FEE WILL ' BE CHARGED AT TIME OF INSTALLATION PIONEER DIGGING, INC. CUSTOMER: THO,Mr��'VEBB TEST HOLE I: TEST HOLE 2 PARC Fl # 37227 a2-00140 0-12 LOAM 0-16 LCAM(SEMI COMP.) 12.35 GLS 16-31 GMS SEPTIC DESIGNS ADDRESS: 14891 NORTH SHORE RD ROOTS @ 35 ROOTS @ 31 3083E MASON BENSON RD. CRAPEVIEW,WA 98546 DESIGNER: ROBERT H.PAYSSE DISCLAIMISIE 7$NOTA SURVEY."EF�CESINCi,,3E'APPL'GNT000NT'PROVIDED PLATS P OR SURVEYS,FIELD MEASUREMENTS AND COUNTY:•s.DESIGN INTENDED FOR SEPTIC PURPOSES OFFICE-360-F26-1803 FAX•360-427-2353 SI 1EET: SITE PLAN SCALE 1"=30' CY NEvEW DESDESKOON NOT REYDAS,L.FOR 6ETSACK$UMiE:ATED TO SEPTIC COM ONENT&