HomeMy WebLinkAboutBLD29236 Final SFR - BLD Permit / Conditions - 12/24/1991 L6rtsrvD AAA of
Shorelines: Plumbing: /l- Y-y'i
Setback: Mechanica • + . . - ,)
Special Interior:
Conditions: $'FINALS/,�1y�gj
Mobile Hcme:
Smoke Detector*-,E;-
.3:5v^ Remarks: G'9.3 Awl
wing Z54'45 eAd IsFAZZ JEaiT A4711 AWZ15
Setback:
Foundation e9w
Walls:
Framingr
Fireplace: -- ���.� >/ 57- 117 �4 ;�-412
Wood Stove:
TYPE RESIDENCE
Permit No.29236 No. Floors 1 Sq Ftg 1344
Owner Kira. Orcutt Te1272-2480 Date 10 '8 91
Address PO Box 1332 Belfair 98528 Zip
Contractor Ste hen Johnson Inc.
Address Zip
Legal Description 31 23 2 Collins Lake Div 4 Tr 4
Direction to project site rjAp ATTACHED
Plumbing Mechanical X Sewer Wood Stove
Fireplace Deck Tarage Z rport
Basement soft Other
BUILDING PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
426 W. CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584
427-9670 DATE ISSUED '
PERMIT NO.
NAME MAILADDRESS CITY&STATE ZIP PHONE
OWNER irk Kum'
DIRECTIONS
TO JOB SITE
PARCEL EGAL
NUMBER Z3�J/ SJ ���DER. �Ol1j,"5 4,4� y ll�A'�*
NAME MAIL ADDRESS _ CITY&STATE ZIP HONE LICENSE NO.
CONTRACTOR S-Te 4ef?j ��hSoh lVC- /(fit`" �'11lUia� Cl-- ��'¢�K Z S-6�3S�
USE OF / .
BUILDING � t`c+�Qk ce J✓ e/u� ! �-
CLASS OF NEW x ADDITION ALTERATION REPAIR MOVE REMOVE
WORK ✓ ,-
DESCRIBE
WORK �!$ 7'J^l.I C Gl e c<J de L.+C e
AREA: NUMBER OF: PLEASE INDICATE: NOTICE
RESIDENCE
SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR
�3 qFt STORIES SHORELINE❑ CONDITIONING.
BASEMENT SgFt BEDROOMS _ PRIMARY RES.❑ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT
DECKS S Ft BATHROOMS Z- SEASONAL RES.❑ COMMENCED WITHIN 180 JAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
g ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED.
CARPORT SgFt FIREPLACE IS CARPORT/GARAGE
GARAGE SgFt ATTACHED❑DETACHED❑
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT 1 AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF
REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE
REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN
IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH. NGES SHALL BE MADE WITHOUT FIRST OBTAINING
OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILD'
UILD G DEP ITMENT.
X OWNER DATE X BY _ _DATE
FOR OFFICE USE ONLY
DEPARTMENT APPROVED DEPARTMENT APPROVED BUILDING VALUATION
YES NO YES NO
HEALTH PUBLIC WORKS FEE
PLANNING FIRE MARSHAL BUILDING PERMIT
D.O.T. BUILDING PLAN CHECK J
SPECIAL CONDITIONS BUILDING GROUP PRE-INSPECTION
SHORELINE
WOODSTOVE
z
PLUMBING
MECHANICAL
STATE BUILDING FEE 1 v
PPLICATION ACCEPTED BY [PLANSCHECKBY APPR D F09 ISSUANCE PERMIT VALIDATION y eQ
,' 'Cl BYlb-li] CASH CK MO TOTAL
PLUMBING & MECHANICAL PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
426 W.CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584 1
427-9670 DATE ISSUED
PERMIT NO.
OWNER N E /MAIL ADDRESS �� CITYdSTATE j PHONE
DIRECTIONS
TO JOB SITE
LEGAL
74E
CONTRACTOR N MAILADDRESS CITY&STATE LICENSE NO. Z PHONE
-Q _
USE OF
BUILDING
PLUMBING FIXTURES MECHANICAL FIXTURES
NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE
L- WATER CLOSETS FORCED-AIR/GRAVITY TYPE FURNACE 6.00
BASINS 1 FLOOR/SUSPENDED FURNACE 6.00
BATHTUBS BOILER/COMPRESSOR 6.00
SHOWERS q REPAIR/ALTERATION 6.00
WATER HEATERS REFRIGERATION COMPRESSOR SYSTEM 6.00
AUTO.WASHER AIR HANDLING UNITS 7.50
SINKS HEAT-PUMPS 6.00
FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET
DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT
LAUNDRY TRAYS FIRE SUPPRESSION 5.00
CONNECT TO CITY SEWER WOOD FURNACE 5.00
DISHWASHER
DISPOSAL
URINALS
PERMIT BASIC FEE 3.00 (j PERMIT BASIC FEE 10.00
TOTAL TOTAL
SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS
SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED.
OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED
THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR iN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE
COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL
WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE
WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT.
X OWNER DATE X BY DATE
FOR OFFICE USE ONLY
APPLICATION ACCEPTED BY PLANS CHECK BY� BUILDING GROUP APPROV OR UANCE PERMIT VALIDATION
BY 7 tl I CASH CK MO
SUN 5 . 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 08/06/91
PI'--.E: B:SGC1190 .WS HOUSE ID: SGC1190
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Site: COLLINS LAKE Analyst: BELLY BUECHEL
Jurisdiction:
Utility: MASON COUNTY PUD #3
Homeowner: KIRK ORCUTT
Mail : Floor Area: 1344 ft2
Builder: STEVE JOHNSON Weather Data: Olympia, WA
Address: NE 701 MISSION CREEK RD Climate Zone: 1
------------------------------------------------------------------------------
------------------------------------------------------------------------------
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code.
REFERENCE PROPOSED
COMPONENT PERFORMANCE 267 266 Btu/hr-F
ENERGY BUDGET 3. 96 4 . 23 kWh/ft2-yr
REFERENCE DESIGN
Reference
Component Value X Area = UA
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
On Grade Slab F-0 . 540 152ft 82 ..1
Glazing @15% U-0.400 201 . 6 80.6
Doors U-0. 200 42 .0 8 .4
AG Wall U-0.058 934 54 .2
Ceiling U-0.031 1344 41 . 7
Infiltration - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
Reference UA 267
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
On Grade Slab RO Uninsulated F-0. 730 152ft 111 .0
Glazing @11 % **VINYL W/AR XO U-0.370 101 . 0 37 .4
**MILGARD VINYL PATIO W/AR U-0.480 42 .0 20. 2
Doors Metal 1 -3/4" urethane flush U-0. 140 42 . 0 5.9
AG Wall R21 INT T1 - 11 U-0.056 993 55 .6
Ceiling R49 blown A is STD baffled U-0.027 1344 36 . 3
Infiltration Standard Air Sealing ACH-0.350 10416ft3 ( 66 . 7)
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
Proposed UA 266
Struc Mass Slab w/carpet w/pad, Sheetrock wall M-5 .000 1063 5315 . 0
Slab w/No cover, Sheetrock walls M- 10 .000 281 2810.0
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Items in parentheses not included in COMPONENT PERFORMANCE totals.
** Denotes non-standard values - check calculation of thermal value.
Page 1
WATTSUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 08/06/91
. a
FILE: B:SGC1190.WS HOUSE ID: SGC1190
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Electric: Zoned
Make:
Model .
System Efficiency: 100 %
Modified Efficiency: 100 %
Heating Load(at 53F dt) : 20174 Btu/hr
System Size: 5. 9 kW
Maximum Size @150% : 8.9 kW
Average Annual Heat: 8242 kwh -
Annual Cost: $ _4W = �—
Ventilation Type: Non-Heat Recovery
Option: Option 1
Cooling Load(at 5F dt) : 19624 Btu/hr
Recommended Size @125% : 2 .3 tons
Solar Access: Partially Shaded -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
GLAZING ORIENTATION
PROPOSED PROPOSED
South: 0.0 ft2 North: 0.0 ft2
Southeast: 0.0 Northwest: 0 .0
East: 60.0 West: 83 .0
Northeast: 0 .0 Southwest: 0 .0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Economic and energy consumption estimates are designed for comparative
purposes only. Actual cost for heating will vary depending on weather
conditions, occupant lifestyle and other factors.
Page 2