Loading...
HomeMy WebLinkAboutBLD2000-00119 Final Garage - BLD Permit / Conditions - 5/17/2000 Inspection Line(360)427-7262 MASON COUNTY PERMIT ASSISTANCE CENTER Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 �'--�7�"� Shelton, WA 98584 ����F_� _7 RESIDENTIAL BUILDING PERMIT 1119 OWNER: PHILLIP ZETTY 360-275-4681 CONTRACTOR: RECEIVED: 02/10/2000 SITE ADDRESS: 191 NE COLLINS LAKE DR TAHUYA ISSUED: 09/08/2000 PARCEL NUMBER: 223315200057 EXPIRES: 0 /08/2000 LEGAL DESCRIPTION: COLLINS LAKE#3 BLK: LOT: 57 PROJECT DESCRIPTION: DIRECTIONS TO SITE: GARAGE NORTHSHORE TO BELFAIR TAHUYA RIGHT AT FIRE STATION ON COLLINS LAKE DRIVE, ON THE LEFT JUST PAST 2ND OR 3RD PLACE, AFTER MOUNTAIN VIEW PLACE General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: 5N Type of Use: SF Insp. Area: 2 No. of Bathrooms: Occ. Group: U1 Lot Size: Deck: Type of Work: ACC Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Garage-Detached 864 Valuation: $16,347 Building Height: 14 Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline & Planning Information Make Length: Ft. Front: E 113.0 Ft. Shoreline: Ft. Water Body: Rear: W 24.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: N 54.0 Ft. Shoreline Desig.: Year: Serial No.: Side 2: S 17.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KLW 02/10/200 $42.00 52631 Building State Fee MJB 02/22/200 $4.50 52846 Building Permit Fee MJB 02/22/200 $249.75 52846 Environ.Health Plan CEB 02/24/200 $25.00 52846 REtWte AHB 03/07/200 $70.00 52846 Total $391.25 BLD2000-00119 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD2000-00119 CONDITIONS FOR BLD2000-00119 1) Approved per dimensions and setbacks on submitted site plan. X A16- 2) All upland areas disturbed or new d by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 0 3) All construction and demolition debris must be removed from the property after project completion. Pr isposal of construction debris must be on land in such a manner that debris cannot cause water quality degredation of State waters. X 4) This application is su v Ito Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X �) 5) The use, handling and storage of hazar�aterials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 6) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is propose to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may t your project. X 7) Proposed structure or any portion thereof greater than 30" in height fro�ine, must maintain a minimum of 5'setback from all property lines, easements and 10'from all County and State Road right of ways. X 8) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X i �CJ 9) All approved plans are required to be on-site for inspection purposes. If inspection is ca ed for and plans are not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(mi i our) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X BLD2000-00119 Please refer to the following pages for conditions of this permit. 2 of 3 10) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS, A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TOP T ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. X -1/6 11) THIS STRUCTURE IS CONSIDERED UNHEATED SPACE. AT SUCH TIME THIS CONDITION CHAL91fA CHANGE OF USE PERMIT AND A MECHANICAL PERMIT SHALL BE APPLIED FOR AND APPROVED PRIOR TO THE CHANGE. X 12) The approved plot plan is required to be on-site for inspection purposes. If inspect is called for and plot plan is not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(� 1 hour)will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X 13) No Occupancy. This structure is limited to U-1 use only (private garages, carports, sheds, and agricultural buildings.) use will be in violation of the Uniform Building Code and Mason County Regulations unless a "Change of Use" permit is approved. X 14) Any changes in constructio all be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction.X 15) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC EQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF U CCUPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x 16) Changes to approved building plans that effect compliance to the 1991 Washington State Energy Code, 1991 Ventilation and In Air Quality Code, the Uniform Building Code and/or Mason County Regulations must be approved by Mason County prior to constructionX 17) CONSTRUCTION PROCESS TQ JeLD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE.x /� 18) Proposed structure or portions thereof with an project er 30" in height from grade line, must maintain a 5' separation distance between adjacent structures and their furthest projections. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before buil g can roc pied OWNER OR AGENT: DATE: BLD2000-00119 Please refer to the following pages for conditions of this permit. 3 of 3 CONCRETE_ MECHANICAL MOBILE HOME F?otin,ys-Setback date by Ribbons date : by _ Gas Piping date b Fouvlation Walls date by Set Up date - by INSULATION date by BG/S�AB Insulation Floors Final date FRAMING by date by date by Walls FIRE DEPT. date by date by date by I PLUMBING OTHER Groundwork Attic date by date by � D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date / _�X� by TA date by /242 V L i� / Site Plan �+ Suite e•16521 Highway 99•Lynnwood,WA 98037-3199 PI ass Check After Doing Site Plan: �I Septic and drainfield E"]Lot size Draw North Arrow in 'cle TOVVIl&C011ll Everett: (425)259-4171 Puyallup: (253)840-9552 Property dimensions ❑Sewer lines eElevation of property iiiiiiiiiiiiiiF POST FRAME BUILDINGS Administrative Headquarters: (425)743-1555 XlStln buildings NJ/ proposed?3<Setbacks Of d existing buildings FAX: (425)742-4378 Toll Free: 1-800-824-9552 g g P P 9 ❑Bodies of water Contredoes Llc.t:TOWNCPF099LT Proposed building Main road with name ❑Floorplan CCelr: 129311 ❑Easements hO Access to proposed building ❑Slopes&Contours(5'increments) Qua!!ty:Our Future Depends On/t'" Job Name:T14 ILL VP r--rT x Job Site Address:- COkkINS 1AITS, R0+1 oef� Legal Description: olht NS LAKV 41 3 L-OT 5 7 TA HuyA t WA Tax Account 0' +� 331 S2 000 7 I Q� 0ro. I , 10 r 11 � , i_ , l I ' i ( _ i � r i ................ I_ R>`slue C E N ; O o i ! I t i......_... ._. 7-- G ARAG>F -`fIS-T 0, CORAYF-L DR%VF-WAY C� i , 24. 113 i I Suite a•16521 Highway 99•Lynnwood.WA 98037.3199 -MMEMMMOMiiiiiiiiiiiiiia OWn &COUn&V Everett: (425)258-4171 Puyallup: (253)840.9652 POST FRAME BUILDINGS Admirmtrative Headquarters' (425)743.15% Cont(425) sic.0:78 Toll Free: 1-80o-824A552 Building Design Contractor's Lic.N:TOWNCPF099LT CCB#: 129311 Qrablq: Ow Future Depenh On h PLEASE CHECK: FLOOR PLAN Draw North Arrow in Circle oll-up doors fit in Bays -.QWind MPH. Roll up doors will not hit Truss _Wind Exposure 12Roof Pitch Eave Height Snow Load _Minimum Clearance .... f 18,; Q V e�RHAN Ca t-- i 'CA L7� N ' 1CQaF _ _..... _........ 6 xAS ; �S a.L' . f • f i L iOrx cNB 51t-0 lo' 19 PoAtfile Ck � SRU _._:._.. ...�.;_.__.:_Y.....__�«--�F+'—�--t••—.i—-�Y.�......:....—�w�....—i.—+.jam.•--:...... _fir.+_—:._�i.�._�—�_..i.--�:i�►••—.i—�1��—i.�--�� i---^-+---•-•-••i ....._._........—.....«_....... »._..._ _ . f i p i ; ; t i i i i i i j I ' f .i. ._i.........._.ti__ —..-' _.. --_. ._. « ._ .._.._—i....._.........._........ .. ........ ........... . ......... ........ .................... ......_ .........:..._.._..........»._'_.__... _...' ' _ .... ...... .. _ — —.—_ I t7 e e ; f .... .........i_.._.._i........... 1_._.L.........._'_..-.... .__ _... .. ..._ _. _..... .._.. ..... — .__ .... «... _ . i : t , i --. .. ..... i 3 I 1 I ; i : i BUILDING ELEVATION Customer has verified and approved the orientation of the building to the North and verifies that all items specified in Paragraph B of the contract are shown on this drawing and vice versa. Customer Name: 74 I G,t I AErry, j,tad# i'�07.Z5 Customer Signiture: White-Customer Copy Canary-Office Copy Pink-Accounting Goldenrod' uetion 1995 Perrna-Bi8 Industries FR-85 "It Site Plan i- c- -I . suite B•16521 Highway 99•Lynnwood.WA 98037-3199 PI ase Check After Doing Site Plan: Septic and drainfield eLot size Draw North Arrow in le TOVV11&COMM Everett: (425)25874171 Puyallup: (253)840-9552 Pro a dimensions ❑Sewer lines I POST FRAME BUILDINGS Administrative Headquarters: (425)743-1555 p rJ Bodies Of property FAX: (425)742-4378 Toll Free: 1-800-824.9552 xisting buildings Setbacks of proposed&existing buildings ❑Bodies of water Contractor's Lic.N:TOWNCPF099LT Proposed building Main road with name ❑Floorplan CCBO: 129311 ❑Easements 9 Access to proposed building ❑Slopes&Contours(5'increments) Qudlty: Our Furore Depends On It.' Job Name:THOLL11 W . Z:E'TTY Job Site Address: CO U I N S LA K 6. R0610 e�Tax Account': ����� Legal Description: yl t f N S LA Kr- 3 41 1-0'T 5 7 TA N U`A t WA �2331 S2 i 1._ 0• 0.0 E ; ;. I ( I 4-__ I i 64 I I ExIST1K6 q slv� N c E LL i i ; I ATE a I 3 �'o4li S CIL " i -_ ... PROPosVa , , t I _ ++ riARAG>� IS (bl�WL DR 1 I I�EWIIY ...__._ _..J.-.. : ?4 113 I _. s 17� - -_ j _.— ... 1 ..._ ! 040i I ID j ` 1 t.I I PERMIT NO.: BLD MASON COUNTY BUILDING PERMIT APPLICATION 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 APPLICANT INFORMATION CONTRACTOR INFORMATION Owner 11ILLtp Zt.-r-trV Contractor Name -majj � tea gy YET FRIG isul"Has Mailing Address �', o , �� 69;s: Mailing Address_ lk<21 N 1614AY 49 City fiilrA I f_ State JAAA Zip Code_q$Sa8 City LYNN W on> Stag Zip Code Phone(360 )ZrS-A4&81 Other Ph.( w ) Ph.( 8©a ) 621'L LTS20ther Ph.( 42S);ISS-y171 Lien/Title Holder (j'A Contractor Reg. #'TbIny C2Fo941 LT Address V1 1A Expiration w l 30 .l DO SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic_tLQ__Existing Septic_&_Q __Connect to Sewer SystemJJ_tQName of Sewer System( A Well_ LtL_Water System ✓ Name of Water System ANY PARCEL INFORMATION- t Tax Parcel No. / / I 12 digit S� On n5 T Fire District Legal Description Site Address(Please include street name, streef number and city) Directions to site oil TN y 11940 710cer Will timber be cut Jnd sold in parcel preparation? (Yes/No) bi 0 Is your property within 200' of the following: Body of Water(Name) tt O Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs TYPE OF JOB New Add Alt Repair Other Use of Building Describe Work FgaCa 1I J�1G1I Lomg3j ' j*1Uh53 1k & No. of Bedrooms No. of Bathrooms SQUARE FOOTAGE-1st Floor 2nd Floor 3rd Floor Loft Basement Deck Other sq. ft. Garage At,,Lf Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make N 1A Model Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. ` PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in co ormance they with. No changes shall be made without approval. first obtaining a F5val. I X Date X Date.2 h FOR OFFIC L USE BEYOND THI POINT I Accepted by I r Dubmittal Amount Due Receipt No J .............DEPARTMENTAL F�t*VI tl1� A>?PRovl=^p pNti»D CoiNr�IT�oN coD t7 tS Building Department 14G 00ftl3 Occ Group 01 Type Constr. A) a1 00 Planning Department Environmental Health Department Public Works Department i Fire Marshal Valuation $ I( , 3y(� _. FEES ... Building Permit Fee 2 Site Inspection Plan Review Fee S or v LA., L UFC Plan Review Fee Plumbing & Base Fee Public Works Review Fee Mechanical & Base Fee Other W.50 Wood/Gas/Pellet Stove Fee Other CN D6 Violation Fee Pre-Paid at Submittal 1 00 ) TOTAL FEES n ��l