Loading...
HomeMy WebLinkAboutBLD2006-01150 Garage DDR2006-00229 - BLD Permit / Conditions - 8/4/2006 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 r IrP4 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2006-01150 OWNER: ROBERT HINCHCLIFFE CONTRACTOR: LICENSE: EXP: RECEIVED: 6/28/2006 SITE ADDRESS: 111 NE COLLINS PL TAHUYA ISSUED: 8/4/2006 PARCEL NUMBER: 223315200050 EXPIRES: 2/4/2007 LEGAL DESCRIPTION: COLLINS LAKE#3 TR 50 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Garage Belfair Tahuya Rd. to Collins Dr. , right to Collins PI. , left to 4th property on left. General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: Type of Constr.: V-B Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck: Type of Work: ACC Fire Dist.: 2 No.of Stories: 1 Occ. Load: Building: Garage-Detached 576 Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: N 75.0 Ft. Shoreline: Ft. Water Body: Collins Lake Rear: Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: W 5.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: E 65.0 Ft. Comp. Plan Desig.: Inholdin Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KKK 6/28/2006 $154.21 S22006000 EH Plan Review TW 7/10/2006 $35.00 S12bb6bbb Building State Fee RTB 8/1/2006 $4.50 S12006000 Building Permit Fee RTB 8/1/2006 $237.25 512006000 Total $430.96 BLD2006-01150 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD20 0 6-01 1 50 CONDITIONS FOR BLD2006-01150 1) This parcel is located in a smoke management zone. Please contact a fire warden at (360)427-9670 ext. 459 for further information. X /7W /-V 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X n ko * 3) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X nm14, 4) A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360)427-9670, ext. 450. The building permit will not be"finaled" until the permit holder can show proof that the access permit from Public Works has been "finaled" and approved. x �m >i 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 6) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X S n, k 7) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project. x R m k 8) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X E,47 9) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X P� I� BLD2006-01150 Please referto the following pages for conditions of this permit. 2 of 4 10) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the aetbac�<conditions listed. X 11) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X o lam, At- 12) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X a ha k-4 13) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X m l� 14) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X e !n 4e 15) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be applied for, reviewed and approved prior to the change. X eirf - 16) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X Plyr 17) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 18 Concrete used for basement e t walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X_ rvl BLD2006-01150 Please referto the followingpages for p g conditionsofthis permit. 30f 4 f9) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. X 44- 20) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. x f�" la 21) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X_ P h, N' 23) All property lines shall be clearly identified at the time of foundation inspection. X 24) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X If bn ld, 25) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 2M W 26) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWN ER OR AGENT: „_ `67 �! _ ��/�//, DATE: _ F BLD2006-01150 Please referto the following pages for conditions of this permit. 4 of 4 k W o CONCRETE - MECHANICAL - MANUFACTURED HOMECD Z not$ By J-� 0Footings 1 SetbacksGas Piping _ C� Interior Date B interior-Date B n Y y bate �d—�-�,6 By r oExterxx Date By Exterior-Date By Set-up � - INSULATION�y TI Point Load 1 isolated Footings Date By m BG/SLAB INSULATION Date By Data By FIRE DEPARTMENT Foundation Walls Floors Date By W - Date By Data By rn DECKS � FRAMING Wants Date By -t Date By Data By PROPANE,TANKS PLUMBING Vault Data By Date By OTHER Groundwork Attic Date By Type, Data By Date 8y o.W.V DRYWALL Type. Int Brace Well Gate By W Date By pate By FINAL INSPECTION' Water Line Fire S+epsration O m Date By Data By Date By O m to Pass or Request Inspect. o 0 Type of Insp. Fail Date Date Done By Comments - - Jam- o 0 CD 8 a 0 0 CD m 0 CNN n Z ry Iz O p o n 2 4 Q S E%I STI NO DRIVEWA �[C". °Q, 4V ` 67 / W \ h ti 4 ti O b \ �^ ID O O Q p Z OUl \ d d fi n Z b + 01 U F - -� p J } rn ��O O+t4 (3'W- 1V Q� O �a ��� ONIG11n 31H140 NO' Oa�Oad o 1S3Hla(13 3 1 � o38fISd3W 38V SNOd813S old O N I N N�!d_ ----- APPROVED MASON COUNTY DCD PLANNING' SITE LAN R7QUIRED TO BE ON SITE CF NGES SU' ECT TO AP PRO AL Date tl 66 TOPOGRAPHY PROFILE: _ ------ I I C, fI> Building Permit number. Direction: Scale: r Approval:foroA9ce use _ Building: Owner/Applicant: �<.��..� w ,�- - �� chc%',�,�� Date of Planning: Parcel Number: application: Env. Health: �ir7 h - ._ 1 ■� r■ r' it 11 � 1 � ■�■■ ■f� lfflflfflill ,..A..��1�REr�l�l1!!�� tax. • �.� � fr �ljfOfff ���� aaaa�rl irrarlfffe�� _ NO. �IIwa1P I rr�.. + �—...r..- �'�,� +� Z—•��s����Rif{v l ` _ ■■■��: � '� it I •• • . - l 1p s i . y 1 Exterior custom construction 1476 S. Scheuber Rd. Centralia, WA 98531 Phone Number: (360)736-2753 Fax Number:(360)330-1335 Email: com *Note emails only checked twice weekly. Fax Transmittal Form To: m«o,� �s��-� tU l ���� From: Rhonda/Fred Name: Date Sent: `1 3(-0�v Cc Phone: . Number of Pages: Fax; L4,2-2- —11`r g Message: TfvLA 13 L-b ;1-000 - Cy S�0 COPY I V(t THESE PL.AN� MUST BE ON THE JOB SITE FOR INSPECTION. MUST MEET ALL CURRENT WASHINGTON STATE CODES CHANCES SUBMIT CHANGES FOR APPROVAL Documents attac ed to Appf0i@d p1m: PRIOR TO PERFORMING WORK lift-f4an A_C-,p 'cl-I - Plan revid checkl YEngineering: tel ag6h�1 Num / pesos pae e S S �r� c . C� �� Full truss engineering must be available on site at framing inspection. VENT UNHEATEDAT 1 Sq Ft Per 150 Sq Ft ST U BTU E A continuous foundation is required Found the entire Periruet., of the structure. APPN MASON BUILDING INSPECTOR CHANGES SUBJECT TO APPROVAL ��DATE I 1t105.7 placemcnt of perenil.The building perrnit or copy thereof shall be kept Exception:Scaring studs not supporting floors and non bearing$tUdg rm the$ite of the work Until the completion of the project, may be utility grade lumber, provided the studs are spaced in it1063.1 Approval of construction documents.. One set of Construction accordance with Table R602.3(5), , docunxnts shall be kept at the site of work and shall be open to inspection by 8,ROOF-CEILING CONSTRUC ON the building official or his or bet authori=d reprrsentative. "02,10.5 Truss to wall connection.Trusses shalt be connected to wall plates R1093 Inspection requests, 11 shall be the duty of the pertnit holder or their by the use of acnirrWed connectors having a resistance to uplift anot leas than agent to notify the building official that such work is ready for inspection.11 290 pounds (79,45 kg-) and shall be installed in accop1m= with the Shall be the duty of the person requesting any.inspcetions required by this n-anufActurer's specificationx- eode to provide access to and means for inspection of such work. 9.ROOF ASSENMI..IES 6 WALL CONSTRUCnON m R903.2 Flashing. Flaslrings Shall be installed in such a matmer so as to Jdan l c id n. Load beating ditxtensien lumber for studs, plates and prevent rnoisttrm entering the wall and robf, hesdda shalll be identified by a grade mark. Grade-Studs shall be a rnWi utm No.3,standard or stud glade]urrrbe r_ Locations.Flasbinp shall be installed aatmall and roof intersections;wherever there is a change in roof slope or direction;and around roof opertiagg, REl ADFR CEL4R ' Thi Spat of$ �4 6 18 . 20 2224 26 2 81 ' #.3- 0 z' 322 ' /aX34 .L$ 3 612 A 4 2)2x6' )2x6' )2x6' (2)2x6' )2 x 6 (2)2x6 ) x6l 2r6' )2 x 6 (2)2x6' 2 x 6 (2)2x6r )2x6 D6 x6t z x6t x6' x61 x62 x6a x8 x$2 x8z x82 x82. x8E $ x8t x,8,a Y x8 z8r x82 10zx10z x10 l0 x10 xldz x10 /Ix7.5 3/ax7,5 /ax7.5 3ax7.5 /ex9 /ax910 x8' x102 x102 x102 x}Q ktOz „ L82 3f`x9G rL .. B ' IB2 l_B2 LP x 2 9 9x7`5 / x9. /'x9 /ax4 / z /ax fax9 / 74 /az] S / x105 /ax1o.512 x102 x10z ax LEs �sLl3s. GILB LDa O = 1g2 LB2 !ax9. / x 2 3 A. . 1 . ..1 . 3/ax19_5 rx12 sx12 /rx1214 T lgN I 1 lD a 1:15 s3 /ax1Q5 3/r2]0 z ..GLB 13.5 /ax1350.5 . sO 2 /ax.13_S6 LB= 1�a s 'Vdl Co;rlpasidon Roofing and Tlvo Foot Overhangs/H F.#V Glue L..9egtlts 24F-V4 Foot _Number of cripple studs (1) 2(,2) 3(3) VENT AT 1 Sep Pt Per 150 Sq Ft xab)e 602.3(1) aMpgL§cbedWe DESCRIMON OF B><l"ING»NTS NU7►MER AND TYPE SPACIIVG OIL OF FASTENERS FAMNERS Tm or sole Plate to stud.and nail 2. 6d- , . ' . ' Stud to sole eite.toe nail 3 Sd or2-16d noubic a fact nail l0d Double to lazes,face nail l0d 24• ]c late to" . or blocleyia at btacod wait 3-16d 16"o-c. rDrninimmn 24-4wli offset of end face nail in am 8-16d Blocking etwom fists or raltm to late, nar7 3 Sd at ram and' itux trail 2-1 odeader two with /2" 16d. lb"n c sl eaClt he2&r,two iexas. 16ds hmdc to s to6 rAilaser studs '1od 24"Nail each layer As followv irders seat'!be3 us,2-inch lumber layers l od 32"ox.at top mid bottom and staggered.Two nails at ends rmd at cW,splioe, Wood struanasl mls,wbfloor mofand wall st*Ain to and le wd wall siteathi to Yrmns' /16"-it" 6d cotnanan nail aztbtloor,wall .8d comntton nar7 L"JY 2 1/`-t/� 1' .cotniitott tsarI oa 8d efarmeed nail 6 lz THESE PLANS MUST BE ' ON -TH,E J06 SITE FOR INSPE�TION, r r d tr KJ�Ct U� Generic Garage an dca� I( ' Z) sR I6F-VVV-J �� aK YX . MAW OPENINGS ON MAN POV �� x INCLUDE ALL DOORS a WINDOWS Q t I eCRi INKS 16 17 3 ''j]J I MANUFACTURED TRUSSE / INDICA ALL OPE 1NG5 d-i W 2xt� STUDS AT 2L•O.C. a s r- o. 10'MAX WALL-HEIGHT 5"' PLYWOOD OR aSB SHEATHING APA PANEL SIDING T BE i, • 900 S.F. MAX WITHOUT ONI THE JOB SITE IN'TEMOR BRACED WALLS ' Rjffi&*JLWT O N• '•��.. INDICATE ALL OPENINGS DIMEI`PssOJ`i " a 36'-0- Max -- THESE PLAN' F,�•-6'O.C. j� ENT az• MINa ON. THE � w°N� c sF ON O 'I Zx TOP PLATE FQ OF FLAT I 4 K,ATt:WASHER y :• pirTERNA ` o HE R }I I I I MUST Q, 1 I I I i (1)ROW> GALy.Box e-o.c. MEET •s c_ qu a� ti I I f . EDGES AND Ir O.c. FIELD I)#4 � o IN STEM WALL I i .� 1r I 2 ull r s1 eng�ineerj g must II " - a Ojlabl� on C e at GRADE #4 BAR AT f r l o n g lj it e f t �� APA RATED SHEATHING t$-D.C. w/ F7 11 I i J 3ia-MIN 2410 EXP 1, SHEATH STD HOOK 'MIN. BOTH SIDES OF WALL IN TWO b I I I I J STORY APPLICATlot1S Q NORIZ. 0 'o A c'Oat,=IOUs�req •! � I I J mound the eat' perimeter of I I ao 0 J_ dw stru re. I2• I/Z-A-B..w/ 7'EMBEDMENT c ' (2)AT u3 POINTS FOR ONE STORY- CIS to (3)AT 1/5 POINTS FOR TWO STORY I A C APPROVED HOOK,-END HOLDOWNS c wit8D0#CAPACITY, FILL ALL HOLES SFt A d� t6k d 4E w Ct)Zx MA �b� 4 fJ�'j PLY SHEAT4f AN 4+i ES R 4 Ski 111100W 0�4,ANGES FOR APPROVAL L v�— MIf TO PERFORMING WO,,RJC (2)$4 RE8AR (1)AT TOP.(1)AT BOTTOM cONT, F"DAT10N, TYP /� t1I, ql . L�. r0,vet r V(0 S F " old S ",t C,r$�. y6- try_ 4 r Y5. AT 1 �Q n Per 150 Sq Ft Exterior Braced Wall Panel,4'0"min. (R602.10.3) Alternate Braced Wall Panel 2'8"minimum(R602.10.6) _ Interior Braced Wall Panel,4'0"minimum(R602.10.3C7V Exterior Corner Framing,two 24"panels (R602.10.5) Lateral Restraint Panel,24"single story garage return wall See attached details for additional information Roof Beam[2003 International Residential Code(01 NDS)1 Ver: 7.01.01 By: rich balderston , mason county dcd on:08-01-2006 : 09:31:34 AM Project: Hinchcliffe garage-Location:9'OH door hdrs. Summary: 3.5 IN x 9.25 IN x 9.0 FT /#2-Hem-Fir-Dry Use Section Adequate By:227.2% Controlling Factor:Section Modulus/Depth Required 5.11 In Deflections: Dead Load: DLD= 0.02 IN Live Load: LLD= 0.05 IN = U2196 Total Load: TLD= 0.07 IN= U1491 Reactions (Each End): Live Load: LL-Rxn= 450 LB Dead Load: DL-Rxn= 213 LB Total Load: TL-Rxn= 663 LB Bearing Length Required (Beam only,support capacity not checked): BL= 0.47 IN Beam Data: Span: L= 9.0 FT Maximum Unbraced Span: Lu= 0.0 FT Pitch Of Roof: RP= 3 : 12 Live Load Deflect. Criteria: U 360 Total Load Deflect.Criteria: U 240 Roof Loadinq: Roof Live Load-Side One: LL1= 25.0 PSF Roof Dead Load-Side One: DL1= 10.0 PSF Tributary Width-Side One: TW1= 2.0 FT Roof Live Load-Side Two: LL2= 25.0 PSF Roof Dead Load-Side Two: DL2= 10.0 PSF Tributary Width-Side Two: TW2= 2.0 FT Roof Duration Factor: Cd= 1.15 Beam Self Weiqht: BSW= 6 PLF Slope/Pitch Adjusted Lenqths and Loads: Adjusted Beam Lenqth: Ladj= 9.0 FT Beam Uniform Live Load: wL= 100 PLF Beam Uniform Dead Load: wD_adj= 47 PLF Total Uniform Load: wT= 147 PLF Properties For:#2- Hem-Fir Bendinq Stress: Fb= 850 PSI Shear Stress: Fv= 150 PSI Modulus of Elasticity: E= 1300000 PSI Stress Perpendicular to Grain: Fc_perp= 405 PSI Adjusted Properties Fb'(Tension): Fb'= 1173 PSI Adjustment Factors: Cd=1.15 CF=1.20 Fv': Fv'= 173 PSI Adjustment Factors: Cd=1.15 Design Requirements: Controllinq Moment: M= 1491 FT-LB 4.5 ft from left support Critical moment created by combining all dead and live loads. Controllinq Shear: V= 557 LB At a distance d from support. Critical shear created by combining all dead and live loads. Comparisons With Required Sections: Section Modulus (Moment): Sreq= 15.25 IN3 S= 49.91 IN3 Area(Shear): Areq= 4.84 IN2 A= 32.38 IN2 Moment of Inertia(Deflection): Ireq= 37.85 IN4 1= 230.84 IN4 THESE PLAN-; MUST BE ON THE JOB SITE FOR INSPECTION. Roof Beam[2003 International Residential Code(01 NDS)1 Ver: 7.01.01 By: rich balderston , mason county dcd on:08-01-2006 :09:29:19 AM Project:Hinchcliffe garage-Location:9'OH door hdrs. Summary: 3.125 IN x 6.0 IN x 9.0 FT /16F-V1 -Visually Graded Western Species-Dry Use Section Adequate By:60.1% Controlling Factor: Moment of Inertia/Depth Required 5.13 In Deflections: Dead Load: DLD= 0.08 IN Live Load: LLD= 0.19 IN=U576 Total Load: TLD= 0.27 IN= U397 Reactions(Each End): Live Load: LL-Rxn= 450 LB Dead Load: DL-Rxn= 204 LB Total Load: TL-Rxn= 654 LB Bearing Length Required(Beam only,support capacity not checked): BL= 0.37 IN Camber Reqd.: C= 0.13 IN Beam Data: Span: L= 9.0 FT Maximum Unbraced Span: Lu= 0.0 FT Pitch Of Roof: RP= 3 : 12 Live Load Deflect.Criteria: U 360 Total Load Deflect. Criteria: U 240 Camber Adjustment Factor: CAF= 1.5 X DLD Roof Loading: Roof Live Load-Side One: LL1= 25.0 PSF Roof Dead Load-Side One: DL1= 10.0 PSF Tributary Width-Side One: TW1= 2.0 FT Roof Live Load-Side Two: LL2= 25.0 PSF Roof Dead Load-Side Two: DL2= 10.0 PSF Tributary Width-Side Two: TW2= 2.0 FT Roof Duration Factor: Cd= 1.15 Beam Self Weight: BSW= 4 PLF Slope/Pitch Adjusted Lengths and Loads: Adjusted Beam Length: Ladj= 9.0 FT Beam Uniform Live Load: wL= 100 PLF Beam Uniform Dead Load: wD_adj= 45 PLF Total Uniform Load: wT= 145 PLF Properties For: 16F-V1-Visually Graded Western Species Bending Stress: Fb= 1600 PSI Shear Stress: Fv= 175 PSI Modulus of Elasticity: Ex= 1400000 PSI Ev= 1100000 PSI Stress Perpendicular to Grain: Fc perp= 560 PSI Bending Stress of Comp. Face in Tension: Fb_cpr= 1050 PSI Adjusted Properties Fb'(Tension): Fb'= 1840 PSI Adjustment Factors: Cd=1.15 Fv': Fv'= 201 PSI Adjustment Factors: Cd=1.15 Design Requirements: Controlling Moment: M= 1471 FT-LB 4.5 ft from left support Critical moment created by combining all dead and live loads. Controlling Shear: V= 588 LB At a distance d from support. Critical shear created by combining all dead and live loads. Comparisons With Required Sections: Section Modulus(Moment): Sreq= 9.59 IN3 S= 18.75 IN3 Area(Shear): Areq= 4.39 IN2 A= 18.75 IN2 Moment of Inertia(Deflection): Ireq= 35.14 IN4 1= 56.25 IN4 THESE PLAN._ 1VaU5T I3F ON THE J0.13 SITE FG ['ION. go pan !■ P1■ W ■ ■ ■■■■■■ ■■■�■�■■�► ■ ■■■■ ■ ■_, ■■■■■■ ■ ■■■■ ■■■■■■ �ME ■ ■IN m ■al mmmmm I 'm ■■■ ■ ■■ ■■n■■■■'�. ■ TA di3 ■ r I • •• • r • .. .. .. �c�--.e.-.—ww•--�,�Er-.•..ram.,—.... .— .,;,. ....,..,. ..�. . ... MASON COUNTY PERMIT NO._ � BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 I On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner Re F,Ai1"e /�' hG �c �' �r Company Name Mailing Address •c'- /3-x 6� Mailing Address City *y p.r f state (,11A Zip Code 7�3 City State Zip Code Phone]60 '471 ��� Other Ph. Phone Other Ph. Lien/Title Holder 1v 4 Contractor Reg. # Exp. E mail address u." E Mail Address Drivers Lic.# N'AI c14 I?w 66*7 J13 DOB 2 Z.35/ , ,g Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. 22 33 u z voosv Fire District �-- Legal Description 1-vt ° C_4,/,//ef Li k e 3 Sac 31, T23 M, R 1 Woo. M<.f•h caom gl/ (,U'f_yi Site Address (Please include street name, street number and city) Directions to site 13` f + " /74 Na Y" Rd 71 E./fir^s or R 44T 7a 6,1 1" f Lf,r LW� Cj1H f"'rfr4- on A. e7 Will timber be cut and sold in parcel preparation?Yes No Is property within 200' of Saltwater AL Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes No TYPE OF JOB - New ). Add Alt Repair Other PRIMARY RESIDENCE [aSEASONAL ❑ Use of Building Describe Work `'�_' d'" '� ''"` h Y jG`r't c No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq. ft. Garage�_ti7i!�Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No.- No,-ef'8edrooms No. of—Batt rooms Type of Heat -PGrchase Price$ / Replacement Unit,? Yes-r_o Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFA PROGRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X Date: Ja c 2 Sfl z ao 6 j wn /Owners epresentative/Contractor (indicate which one) I FOR OFFICIAL USE BEYOND THIS POINT Accepted by: - �. - Date (4� ULln DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Departmentf&9 2kZ 196 Planning Department l' Environmental Health Department 4 Fire Marshal FEES I Building Permit Fee Site Inspection Plan Review Fee S1�/ EH Review Fee Plumbinq & Base Fee �— Planninq Review Fee Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee State Fee s� Violation Fee C' - /'0 6 Pre-Paid at Submittal Valuation $ TOTAL FEES MASON COUNTY . DEPARTMENT OF COMMUNITY DEVELOPMENT 411 No. Fifth Street//P.O. Box 186, Shelton WA. 98584 360.427.9670 ext. 352 - Request for Administrative reduction in the Required Setbacks ($90.00) For administrative review, the minimum variance on a yard setback request is 5 feet from the side lot lines and 10 feet front and rear lot lines or right of way. Request for further reduction requires standard variance. Setbacks are measured from the furthest proiection of the structure. Applicant/Owners: ,(?eberJ- w end Pe411 ;e M. 14 /ttc�lCc Mailing Address: PC /3 3 City: Pam State: 64".vs h Zip: Site Address: Telephone No.: 6 2- Parcel Number(s): 2 Z 3 3 Zoning In h,n ldt Yam( Requested Variance: Front / Rear • (Side Yard (please circle all that apply) U Requested setback variance: FT. An illustrated site plan is required: Your site plan must show the following: north arrow,abutting street or easements,set backs to all property lines and existing buildings, slopes,surface water,wetlands,critical area,septic, well and driveway. Show all proposed new development. The following circumstances must apply. Front and or Rear Yard requirements: 1) Existing lots of record as of March 5, 2002; You must meet one of the following. (Please circle all that apply) 2) One of the following exists on the lot: a) steep slopes, wetlands, or streams present; b) soils that restrict building or septic development; c) lot width at the front yard line of no more than 50 feet; d) lot size of no more than one-fourth acre; e) existing improvements of buildings, septic systems, and well areas. Side yard requirements: 1) Existing lots of record as of March 5, 2002; You must meet one of the following. (Please circle all that apply) 2) One of the following exists on the lot: a) steep slopes, wetlands, or streams present; b) soils that restrict building or septic development; c). lot width at the front yard line of no more than 50 feet; (.d),-,Jot size of no more than one-half acre; existing improvements of buildings,jseptic systems', and well areas HAadministativevariance.doc (tw) February 05 Explain how these circumstances preclude a reasonable development proposal from meeting the setback standard for Rural Residential 2.5, 5, 10, or 20 zones. Owner/ gent (please indicate) i nature and date 9 Official Use Onl y Approved Date ! lib Denied Date Reason for denial: HAadministativevariance.doc (tw) February 05