Loading...
HomeMy WebLinkAboutBLD2005-01209 Final Detached Garage - BLD Permit / Conditions - 6/8/2006 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 ,o RESIDENTIAL BUILDING PERMIT BLD2005-01209 OWNER: CINDY COLSON RECEIVED: 7/19/2005 CONTRACTOR: LICENSE: EXP: ISSUED: 8/2/2005 SITE ADDRESS: 211 NE COLLINS PL TAHUYA EXPIRES: 2/2/2006 PARCEL NUMBER: 223315200044 LEGAL DESCRIPTION: COLLINS LAKE#3 TR 44 PROJECT DESCRIPTION: DIRECTIONS TO SITE: Garage/Detached North Shore Rd. to Belfair Tahuya Rd, to Collins Lake. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: No.of Stories: 1 Occ. Load: Building: Garage-Detached 864 Valuation: Building Height: 16 Occ. Status: Unknown Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: N 158.0 Ft. Shoreline: Ft. Water Body: Rear: S 60.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: W 36.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: E 12.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures FEES Mechanical Fixtures Type Qty. Type a By Date Amount Receipt Plan Check Fee KKK 7/19/2005 $217.91 S22005 Planning Review Fee KKK 7/19/2005 $155.00 S22005 EH Plan Review TW 7/21/2005 $35.00 S22005 Building State Fee ARC 7/25/2005 $4.50 S22005 Building Permit Fee ARC 7/25/2005 $335.25 S22005 Total $747.66 BLD2005-01209 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2005-01209 CONDITIONS FOR BLD2005-01209 1) Approved p ensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0 The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) The internatioanl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads t with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 4) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X (X� 5) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department nrinr to any further inspections being performed or approvals granted. X 6) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 7) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal oved documents will result in failure of required building inspections. X � . BLD2005-01209 Please referto the following pages for conditions of this permit. 2 of 4 8). This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be for, reviewed and approved prior to the change. X 9) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 10) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building De t prior to any further inspections being performed or approvals granted. 11) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete WQrk exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X M 12) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the internatio des and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. X 13) International Building Code. In addition to the inspections required by Chapter 1 of the International Building Code, the owner or the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under , section 1704. The special inspectors' duties & responsibilities shall be as specified in Chapter 17. X 14) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged a Ike collected by the Building Department prior to any further inspections being performed or approvals granted. X 15) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revoc X 16) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X dzs BLD2005-01209 Please referto the following pages for conditions of this permit. 3 of 4 17) All changes to"approved"building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or re n, must be reviewed and approved by Mason County prior to construction. X �) 18) )CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall e prior to requesting additional inspections. X 19) All property lines shall be clearly identified at the time of foundation inspection. X 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Count V�nces and building regulations. X 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit j holder have prevention from being taken. No more than one extension may be granted. 22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, a shing. Install metal connectors approved for contact with the new types of pressure treated material. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and str It`ure for review inspection. OWNER OR AGENT: DATE: BLD2005-01209 Please referto the following pages for conditions of this permit. 4 of 4 W o CONCRETE MECHANICAL MANUFACTURED HOME Footings 1 Setbacks Date By Ribbons ' o Date By ' Gas piping Date By N CD Foundation Walls Date By set-up Date By INSULATION Dale By BG I Slab Insulation Floors FINAL I NSPECTION Date By Date By Date By FRAMING Walls FIRE DEPARTMENT Date By Date By Date By PLUMBING Attic OTHER Groundwork sate By Date By WALLBOARD NAILING Date By DON Date By - Water Line FINAL INSPECTION Date By Date 4 —,7tf>GBy Date By m s Type of Insp. Pass/Fail Request Date Inspect. date Done By Comments CD CD ss J&6 o v r 8 N to a - c O :n CD El 0 L ■ r. sawiiii I. IS M ■■ M■■0 Emil No 0 IS ■M Nor 101 ■E■NMERA■ ■ ■■I ■111S.' N ■■■■it ►� ■■.■il 001■ ■■■■■■■ _. ■■■■�■■■■■■■■ ■I■®�■■■■■■■■■' ■■■■�■ ■■■■■ ■1■M�`■,� ■ ■ � ■■ ■■■■M■AL!■■■■■ ■■I■■ml ►�■■MINIZIPT ! ■■ MIME■IM■■■■■■■■ ■■�. ■�: ■ ■ ■ ■■M !■■■■ ■ilk �■ ■ ■ MIEN ■■I■■E■ii1■ ■■ ■■ IM■■■■■■■■■■■ NMI MMEMO i1■ IF l■■■■■ lom■ ■ ■Iw,■■�■■ EE■■I�E ■■ ■ ■■E■NONE■■■�■ ll;�■I '` ■■_�■� CONCRETE It is beyond the scope of this manual to give adequate instructions on all aspects of pouring and finishing a concrete slab. If you choose to pour and finish the slab yourself we urge you to obtain professional guidance. This is not a project on which to become self-taught. FOUNDATION DETAILS are found on Sheet C_'. The information presented on this sheet should be followed to the letter, all details satisfied. The concrete should cure for a minimum of 5-7 days, depending on climate conditions, prior to erection of the building. Curing in cool or wet weather requires more time. Always verify all form measurements prior to pourmLy. We urge you or your contractor to call us with any questions you may have regarding the foundation or placement of anchor bolts. CONCRETE SLAB ANCHOR BOLT GRADE e e n e WELDED WIRE MESH @ \ SLAB CENTER \ e0 \\ e I UNDISTRUBED w NATIVE SOIL -141 REINFORCING BARS BACK FILL AS REQUIRED Monolithic Slab Foundation Virtually all foundations for WEB STEEL Buildings are monolithic slabs. The information shown in this section is geared toward that likelihood. Accurate anchor bolt placement is critical for proper placement of the structural steel and to ensure a plumb and square building. Thesans will not tit correctly if the legs are either too close together or too far apart. Take the time to P Y .. ., P make certain the dimensions are exact rather than discover the problem when two heavy spans are waving overhead. Remember that all dimensions are measured from the inside of the forms. Corner to corner(diagonal) measurements must be equal in order to assure the foundation slab is perfectly square. Verifv all form dimensions prior to pouring concrete. MEASUREMENTS MUST BE EQUAL Anchor Bolt Placement To accurately place anchor bolts templates must be used. The templates should be made out of 3/4" plywood to hold each anchor bolt securely in the vertical position. Dimensions for making templates will be found on sheets l and Cl. The FOUNDATION PLAN (sheet 1) has a square box located near each anchor bolt location. In the box there is a number above the line and a letter and number below the line. These are the sheet number and detail number where the dimensions and orientation of that particular anchor bolt will be found. The dimensions for a frame base is 1/CI and is located on sheet Cl, detail 1. The detailed dimension for an end column is ?/C 1 and is located on the same sheet number, detail `?. The corner columns are also on the same sheet, detail(s) 3 and/or 4, depending on the type of material (angle or tube) from which the column is manufactured. Additional details will be included when sheds or other attachments are designed for a building. PLYWOOD TEMPLATE SEE PLANS CONCRETE FORM FOR EXACT D OUTSIDE OF DIMENSION SLAB PLYWOOD TEMPLATE SEE PLANS i DUPLEX NAIL FOR EXACT ° CONCRETE DIMENSION i FORM---\ SEE PLANS EMBEDMENT FOR EXACT DIMENSION PER PLANS CONCRETE FORM - OUTSIDE OF SLAB RENEFORCEMENT PER SHEET C2 y SEE PLANS � ,� i ' FOR EXACT ; DIMENSION /O'����✓ice sI SEE PLANS FOR EXACT :IMENSION MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair(360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICA�T INFOR"/�► I�N CONTRACTOR INFORMATION Owner Ci J� Company Name Mailin Address /n5 Mailing Address City A) Zip Code City State Zip Code Phone 3 � Other Ph. i7' 0(03 Phone Other Ph. Lien/Title Holder $ Contractor Reg. # Exp. E mail address e hm,eno E Mail Address Drivers Lic. # CSd0a&2$'I DOB // 4y /g 7 Z Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. Fire District Legal Description Site Address (Please include street n e, st eet umber nd city iAS w Directions to site �r oA-t ��' INS Q Will timber be cut and sold in parcel preparation?Yes/ X Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt Repair— &ther / PRIMARY RESIDENCE ❑ SEASONALUse of Building Describe Work � Yoz No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq. ft. e Garag _ Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANSOFAPR GRE S SECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X Date: 91 A% Owner/Own s Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department- �G I-KA" Planning Department Environmental Health Department Fire Marshal FEES Buildinq Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee " Violation Fee U Qe>�C- Pre-Paid at Submittal Valuation $ ao Z TOTAL FEES