HomeMy WebLinkAboutBLD2000-01263 Cancelled Propane - BLD Permit / Conditions - 9/26/2000 MASON COUNTY PERMIT ASSISTANCE CENTER Plhonpec(360)427(96704ext. 352
Mason County Bldg. 3 426 W. Cedar P.O Box 186
Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT BLD2000-01263
OWNER- MICHAEL OLSON
CONTRACTOR: RECEIVED: 09/26/2000
SITE ADDRESS: 1141 NE COLLINS LAKE DR TAHUYA ISSUED: 09/26/2000
PARCEL NUMBER: 223315100002 03/26/2001
LEGAL DESCRIPTION: COLLINS LAKE#2 TRACT 2 ..�.
PROJECT DESCRIPTION: DIRECTIONS TO SITE: VAX e? 61
PROPANE TANK BELFAIR TAHUYA RD TO LW
INS LAKE DR. TAHUYA RIGHT AT
FIRE STATION (COLLIOL`A'K ). RIGHT AROUND LAKE
General Information Construction & Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.:
Type of Use: Insp. Area: No. of Bathrooms: Occ. Group: Lot Size: Deck:
Type of Work: Fire Dist.: No. of Stories: Occ. Load: Building:
Valuation: Building Height: Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline & Planning Information
Make Length: Ft. Front-. Ft. Shoreline: Ft Water Body:
Rear: Ft. Slope: Ft, SEPA?:
Side 1:
Model: Width: Ft. Ft. Shoreline Desig.:
Year: Serial No.: Side 2: Ft. Comp. Plan Desi .:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Gas Outlets 1 Mechanical Fee KS 09/26/200 $21.30 54683
Propane Tank 1 Mechanical Base Fee KS 09/26/200 $23 50 54683
Total $44.80
BLD2000-01263 Please refer to the following pages for conditions of this permit. 1 of 2
CASE NOTES FOR
BLD2000-01263
f
CONDITIONS FOR
BLD2000-01263
1) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING
DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED
ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR
FAILS
,�TOO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
X 4�"l5
2) If the tank size is between 125 and 500 gallons you must follow these guidelines: 1. Tank is to be 10 feet from any buidling, public way or property line.
2. If the tank is exposed to probable vehicular damage, provide prote tive bo lards. 3. A weeds, grass, brush, trash and other combustible material
shall be kept a minimum of 10 feet away from LP containers. X /VIA cP0CA
3) Fuel piping shall be inspected after the installation of gas piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At
the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances attached to the piping shall not be used
until the final inspection has been approved by the building inspector.
4) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to
Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams,
wetlands, slopes, etc.) If you think such fe '
.9.1_4res_exi§Lo.p or nearby your property, please contact the Planning Department so that exact setback
requirements can be determined.
This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period
of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection
must be approved before building can be occupied.
OWNER OR AGENT: LfG M DATE:
BLD2000-01263 Please refer to the following pages for conditions of this permit. 2 of 2
i
CONCRETE MECHANICAL MOBILE HOME
Footings-Setback date by Ribbons
date by Gas Piping date b _
( Foundation Walls date by Set Up
date by INSULATION date by
BG/SLAB Insulation Floors Final
date by date by date by
FRAMING Walls FIRE DEPT.
date by date by date by
PLUMBING Attic OTHER
Groundwork
date by date by
D.W.V. WALLBOARD NAILING
date by
date by
Water Line FINAL INSPECTION
date by date by date by
I
c
I!
FORM MUST BE COMPLETED IN INK PERMIT NO.:
PLEASE PRESS HARD MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W.Cedar/P.O.Box 186,Shelton,WA 98584
Shelton(360)427-9670 Belfair(360)275-4467 Elma 360 482-5269 Seattle 206 464-6968
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner X4:C-ktt'-- eX:5cDAJ Contractor Name
Mailina Address r. 0 - ' Mailing Address
City State VA Zip Code City State Zip Code
Phone( )�?�=83f�Other Ph.( Ph.( Other Ph.(
Lien/Title Holder Contractor Reg. #
Address Expiration
SEPTIC INFORMATION-Connect to New Septic Existing Septic k Connect to Sewer System Name of
Sewer System
PARCEL INFORMATION-12 digit Tax Parcel No. 3.z / /_L/ �r�c�7�'2 Fire District Z_
Legal Description LOT- 0-
Site Address(Please include street parne, street number and city)
Directions to site &>AQ TO L A'T 6CElg '-'A SZY �tJ 70
p 1Z /FT A-?' �� -57Ar=/U a0c -cszi s cf+4:�E WP ) !� FED'Ae—bok; 4 44 F-
IE your property within 200' of the following: Body of Water(Name) CUB te-Y7 !� e-Ah;�E Saltwater
Lake X River/Creek Pond Wetland Seasonal Runoff Stream Slopes or
Bluffs
TYPE OF JOB New Add Alt Repair Other Use of Building
Location of Fixtures/Units 1st Floor 2nd Floor Basement Garage Closet
PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Fuel Type: Electric
Type of Fixture No. of Fixtures Fees LPG 7, Natural Gas Heatpump
Toilets Type of Unit No. of Units Fees
Bath Basins Furna
Bath Tubs Heatpumps
Showers Vent Fans
Water Heater Propane Tank Z
Laundry Wsher Gas Outlets ► so _
Sinks Wood/Gas/Pellet giove
Dishwasher Direct Vent?
Other Other
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTURE/UNIT.
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and
inspection of this project. Acknowledgment of such is by signature below:
OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a
Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance
requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work
conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without
approval. first obtaining approval.
Date X Date
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by Date Submittal Amount Due Receipt No.
DEPAf.U. M VTRLRE11fEW:' APPROVED CJENI�i3. �M1IDiTIQN CU[JES'..
Building Department 1�-a —D d M �se�C( �
Occ Group Type Constr.
Planning Department
Other
Other
E
Permit Fee Site Inspection
Plan Review Fee UFC Plan Review Fee
Plumbing&Base Fee Other
Mechanical&Base Fee Other
Wood/Gas/Pellet Stove Fee Pre-Paid at Submittal ( )
Violation Fee TOTAL FEES