HomeMy WebLinkAboutBLD2007-00241 Addition and Remodel - BLD Permit / Conditions - 3/30/2007 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Irflo Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2007-00241 OWNER: TOM LITAKER RECEIVED: 2/9/2007 CONTRACTOR: LICENSE: EXP: ISSUED: 3/30/2007 SITE ADDRESS: 11681 E STATE ROUTE 106 UNION EXPIRES: /30/2007 PARCEL NUMBER: 222305100006 LEGAL DESCRIPTION: KOHL'S COVE TR. 6 & 5-A PROJECT DESCRIPTION: DIRECTIONS TO SITE: ADD SECOND STORY MASTER BATH 182 SQ FT AND REMODEL FIRST HWY 101 N TO HWY 106 TO ADDRESS ON WATER SIDE. FLOO General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: Occ. Group: R-3 Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No.of Stories: 2 Occ. Load: Building:326 Valuation: Building Height: 22 Occ. Status: Seasonal Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: Hood Canal Rear: Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: W 5.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Lavatories 2 Ventilation Fan 2 Plan Check Fee KS 2/9/2007 $245.21 S12007000 Showers 1 Planning Review Fee KS 2/9/2007 $170.00 S12007000 Water Closets (Toilets) 1 Building State Fee ARC 2/14/2007 $4.50 S12007000 Bath Tubs 1 Building Permit Fee ARC 2/14/2007 $377.25 S12007000 Mechanical Fee ARC 2/14/2007 $16.00 S12007000 Mechanical Base Fee ARC 2/14/2007 $25.30 S12007000 Plumbing Fee ARC 2/14/2007 $38.50 S12007000 Plumbing Base Fee ARC 2/14/2007 $22.00 S12007000 EH Plan Review TW 2/14/2007 $75.00 S12007000 Total $973.76 BLD2007-00241 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2007-00241 CONDITIONS FOR BLD2007-00241 1) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads co ;ect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X ,, 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X `✓ 3) Per engineered stamped plans , indicates option for useing existing foundation or remove and construct new foundation footing and stem wall. if existing is to be used engineer field report is to be on site at time of framing inspection. If installing new foundation all required inspections will need to be done by Mason Cou51y,Building Dept. X '' 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department p job to any further inspections being performed or approvals granted. X s 5) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approyl documents will result in failure of required building inspections. X BLD2007-00241 Please referto the following pages for oonditions of this permit. 2 of 5 7) All exterior wall cavities exposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and inspected prior to covering. X �' 8) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department?oQr to any further inspections being performed or approvals granted. X I 9) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight(Max U-Factor):0.58, Doors (Type/Max Uactor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X 10) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (.3-SECOND GUST)the wind speed for Mason County is 85 MPH. X 11) Per 2003 IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X "zl 12) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X '� 13) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall e.collected by the Building Department prior to any further inspections being performed or approvals granted. X a >` 14) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. x ��" 15) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regular must be reviewed and approved by Mason County prior to construction. X i L " BLD2007-00241 Please referto the following pages for conditions of this permit. 3 of 5 16) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X �Z:% 17) All property lines shall be clearly identified at the time of foundation inspection. X 18) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinanc,�s and building regulations. X �� Y 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have preveV ction from being taken. No more than one extension may be granted. X 20) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flasging. Install metal connectors approved for contact with the new types of pressure treated material. X ,t , 21) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 22) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plpo;tg ensure these structures are shown and meet the setback conditions listed. X r' 23) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 24) Approved per d1lnensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X [" BLD2007-00241 Please referto the following pages for conditions of this permit. 4 of 5 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and.stgjcture fo�eview and inspection. OWNER OR AGENT: G2�r,'�1�� cGt DATE: '"��� L� 7 BLD2007-00241 Please refer to the following pages for conditions of this permit. 5 of 5 � 7o H r/ Bet oo A L S c A L-E / I/ NujLt l v� C>N ary A- D D►T-i DI) 0� 1 P�2-� rs TZ2,94r N v jf/;?, S r- PLANNING r'•�7", 90 ' APPROVED ------ M SON COUNTY DCD PLANNING D F SITE PLAN REQUIRED TO BE ON SITE CHANGES SUBJECT TO APPROVAL �� -- —�•- r____�.�_.,.�-/..d B Date 21 f(0� _ ' I zo y < p W osDo fQ)I � J - � cL LL - L r SEPn f AcIJ I � ri 7 R+DD�.3 o� 14, aoR- J I I tad °` i - S r -t� X IST G Cooca-FtE (3 h At, 7A- MASON COUNTY PERMIT NO�`-�V ! U D�`� BUILDING PERMIT APPLICATION I'Se ll 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 C IJqtY60) 427-9670 - Belfair (360) 275-4467- Elma (360) 482-5269 MASON vu On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner /0 ;i�4?961VZW L 7'R/C�C_ Company Name Mailing Address /11o46 sAtk iDG,c 40 Mailing Address City&- iVi'e4(t4' State i'J'} Zip Code 982 7f4 City State Zip Code Phone 34.6 --71-' -97fr3 Other Ph. 3�oU-�L�-1S�a Phone Other Ph. Lien/Title Holder ZZJAE&IN6 trAl H07z1_ L_ Contractor Reg. # Exp. E mail address yE Mail Address Drivers Lic.# ytr.ajt. DOB 9-4 Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System _" es B'q✓Name of Water System_ oozes 1UArrJ� 0'o. Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No LL 3cs1 t),3cj Fire District Legal Description S-cxf)q77-/}cffr� /)b1 .A . (tdyEi •Site Address (Please include street name, street number and city) 116,81 /p L Directions to site Will timber be cut and sold in parcel preparation? Yes 16) Is property within 200' of SaltwategS_Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action? Yes o TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE D ern Use of Building SyHh,�2 94ti Describe Work .4.0o S'-lGO.W sr42Y /I4_Yr �3�r'N /FZ No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor oDe. 3rd Floor Basement Deck Covered Deck Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTU ED ME INFORMATION -T. ake Model Year Length Wi Serial No. No. of Bedrooms o. of Bathrooms Type of Heat Purchase Price $ Replacement Un' . Yes `& Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROO`Q TINU TIO F WORK IS BY MEANS OF A PROGRESS INSPECTION. X Date: Owner f(5_wrkrs Representative/Contractor (indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by Lt_ Date44 DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department Public Works Department Fire Marshal mZ- FEES ri Building Permit Fee - Site Ins ectio Plan Review Fee EH Review Fee Plumbinq & Base Fee - Planning Review Fee Mechanical & Base fee 3a Other Wood/Gas/ Pellet Stove Fee State Fee ' TT Violation Fee A/D C,c1 Pre-Paid at Submittal Valuation $ Z — TOTAL FEES �li I<er 9k: j+j p�T�4 v�q _ ct, 7 7 6 5' 7 8 a PERMIT NO. ?00 DO a- MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670•Belfair(360)275-4467•Elma(360)482-5269 On the web www.co.mason.wa.us APPLICANT jVFORMATION CONTRACTOR INFORMATION Owner /4 Company Name MailingAddress, lg4o 9fv SKY (D 6E 0 Mailing Address City IJ Z � State N Zip Code Rk � City State Zip Code Phone 360 - '776-$783 Other Ph.3tod-y:z-4-25°.r Phone Other Ph. Lien/Title Holder /DASH-/\ 17A/ Hu rurh— Contractor Reg. # Exp. Email address jf/i 1/-Akera] E Mail Address Drivers Lic.# 4,Y1Ak f c.S/47.� DOB -5 —"'FTY Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic 2M: Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No as D Fire District Legal Description 56f r C Site Address(Please include street name,street number and city) L l Directions to site Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building ON Location of Fixtures/Units- 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UIgITS Type of Fixture No.of Fixtures Fees Fuel Type:Electrie7 LPG—Natural Gas_Heat Pump_ Toilets / Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs _�_ Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other _ Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THI POINT Accepted byC4auPlanning Pd Ck# Date .O Bld Pd Receipt No. DEPART NTAL REVIEW APPROVED DENIED NOTES Building D rtment Occ Group—Type Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES