Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2006-01600 Replacement MFG Home - BLD Permit / Conditions - 9/28/2006
r Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2006-01600 OWNER: JOHN COMERFORD RECEIVED: 9/7/2006 CONTRACTOR: LICENSE: EXP-. ISSUED: 9/28/2006 SITE ADDRESS: 920 NE COLLINS LAKE DR TAHUYA EXPIRES: 3/28/2007 PARCEL NUMBER: 223315000058 LEGAL DESCRIPTION: COLLINS LAKE#1 TR 58 PROJECT DESCRIPTION: DIRECTIONS TO SITE: manufactured home replacement to Fleetwood (1981) 920 NE COLLINS LAKE DRIVE. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: Type of Use: MH Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Valuation: Building Height: 14 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make:FLEETWOC Length: 66 Ft. Front: S 110.0 Ft. Shoreline: Ft. Water Body: Rear: N 20.0 Ft. Slope: Ft. SEPA?: No Model: Width: 28 Ft. Side 1: E 20.0 Ft. Shoreline Desig.: Not Applicable Year:1981 Serial No.: Side 2: W 20.0 Ft. Comp. Plan Desig.: Inholdln Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Mobile Home Submittal Fee CMH 9/7/2006 $214.50 B12006000 Planning Review Fee CMH 9/7/2006 $155.00 61200600o Mobile Home Issuance Fee ARC 9/15/2006 $214.50 612006000 EH Plan Review CEW 9/21/2006 $75.00 B12006000 Total $659.00 BLD2006-01600 Please refer to the following pages for conditions of this permit. 1 of 6 CASE NOTES FOR BLD20 0 6-01 6 00 CONDITIONS FOR BLD2006-01600 1) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depart�t prior to any further inspections being performed or approvals granted. X (� 2) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the juri diction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspect X TC_ A 3) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal oVapproved documents will result in failure of required building inspections. X Q') 4) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 5) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will n -of be granted. In addition, a re inspection fee refer to current fee schedule, minimum 1 hour will be charged and shall be collected b the ( ) 9 Y Buil epartment prior to any further inspections being performed or approvals granted. X 6) Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site wi in three of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed o Iled. certification number and signature of the certified installer responsible for each major part of the installation. WAC365-210 X BLD2006-01600 Please referto the following pages for conditions of this permit. 2 of 6 1 7) If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (ANSI). To order the ANSI instructions you may either get an order form from the Mason County Building Department or you can contact the Offfice of Manufacturing Housing (360) 725-2800. 8) Per 2003 IRC - SECTION 1609-WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC t D SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. Xi f 9) Per 2003 IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordarO vyI the applicable provisions of this section and the manufacturer's installation instructions. X � - 10) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical con cr to work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 11) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such It onnect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 12) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in per r vocation. X 13) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my origin permit fees to resolve any questionable practices or problems that have been discovered. I further understand that this investigation will be sched led as time allows. Until res lution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWNER/CONTRACTOR(indicate which) Signatur 14) Lake Cushman area is designated with a 551b snow load rating. The owner/agent of this pe it acknowledges that if the unit permitted under this permit doe eet the recommended snow load rating, there is a potential for failure due to weight accumulation beyond that of the design criteria. X tc Z - 15) This permit is for t ment and installation of the manufactured home only and does not imply approval or review for any other items indidcated on the plot plan. X BLD2006-01600 Please referto the following pages for conditions of this permit. 3 of 6 16) Permanent Address must be posted and visible from the road Deck must be safe and meet code for year building permit was issued. Rebuilt decks are required to meet current code. All guardrails and handrails must be in good condition and meet code for year built or current code if replaced. Skirting must be vented 1:150 and backfill sloped away from unit 2% for a minimum of 5' around the perimeter of the unit Gutters and downspouts must be installed with splash blocks provided All exterior penetrations must be sealed HWT Pressure relief line and dryer vent must exit skirting a minimum of 6"with a maximum of 24" above grade. The unit shall have a minimum of 16"x24" crawl space access provided HOWEVER, if the unit has not received a set up inspection and is skirted, 4 panels centrally located (one on each side of unit) shall be removed by the owner/applicant prior to requesting the inspection. All conditions on the original or issued permit must be met If the unit was installed by a WAINS certified installer/contractor since July 1, 2003, CTED Installer Tags must be available It shall be the responsibility of the person requesting the inspection to provide the manufacturer specifications, ANSI Standards or approved engineered design for the installation of the unit and have them available on site for inspection. Each inspection required will be assessed a fee as adopted under Mason County current fee schedule. Re-Inspection fees will be assessed each time an inspection is requested and required items are not completed prior to the inspection being performed ENFORCEMENT PROVISION: Any manufactured/mobile home and/or appurtenant structures found non-compliant with any county or state regulation are subject to enforcement action and subsequent violation and penalties pursuant to the Mason County Code. X u 1 17) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your pro' X 18) All charlges to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordin or egulation, must be reviewed and approved by Mason County prior to construction. X BLD2006-01600 Please referto the following pages for conditions of this permit. 4 of 6 19) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspecto a made prior to requesting additional inspections. X 20) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be clearly marked in the installation instructions. 21) All property lines shall be clearly identified at the time of foundation inspection. X ,� i 22) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason o my ordinances and building regulations. X 23) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holde evented action from being taken. No more than one extension may be granted. X 24) Pressu a treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, conn o , d flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 25) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these str c(t�uress meet the setback conditions listed. X 26) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "ApprQye Site Plan"to ensure these structures are shown and meet the setback conditions listed. 27) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 28) Water q It? not to be degraded to the detriment of the aquatic environment as a result of this project. X BLD2006-01600 Please referto the following pages for conditions of this permit. 5 of 6 29) Prior to final approval, all upland areas disturbed or nTly Tated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). XU 30) Appro er dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progreq inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property/and structure for review and inspect' n. OWNER OR AGENT DATE: BLD2006-01600 Please refer to the following pages for conditions of this permit. 6 of 6 120 — • ' AlC X,5�- tip, f ya �_,__�..�.,�._.� _� 1. � . ,, • � { >; � t , t j ! w� ♦ f j A i.� 1 i E I } Toll j! i i- W�.6�- .J TOPOGRAPHY PROFILE: ' y-x t -- J 7 7 Building Permit number: - Direction: Scale: Approval: for office use " / I _ �p Building: Cwner/Applicant: �oV r- C(O Vy, c Vo �U Planning: Date of pplication: Env. Health: Parcel Number: v2a- 33 (500Cp S a , 91 D Zoo(o - o16e0 27 33/ - 5o - 000s8 n Cow ev Fcw� NT i ( f MUST MEET ALL CURRENT / WASHINGTON STATE CODES . �3 y7ao r� MAs Tc -j2 z i i Kr4 ca � I FILE- COPY l THESE PLANS MUST BE 2ow`r ON THE JOB SITE � FOR INSPECTION 0 �•`�;, 'a n � � EG , ES q� 11.�idJG 1NS :�L PRpV P / GA Sp Pe i Of' �;.ir�mtT CHANGES=()R APpROVAL Gtl�lap�S S�'pPZ� h �R�Q rG PERFORMING WORK _ MASON COUNTY PERMIT N0000 t, a BUILDING PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFOR TION CONTRACTOR INFORMATION Owner J_ ^� ovr+t r�o e Company Name Mailin Ad�ress 9 k �l C R Mailing Address Citya Stat 0- Zip Code 011 13 5'9 City State Zip Code Phone Zy 3 - 8'S'8'- t Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address "' E Mail Address Drivers Lic.# rt-s2 u1 DOB s-I $ S7 Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Col( I W S Lc.k t: Well Sewer System Name of Sewer System PARCEL INFORVATION - 12 Digit Parcel No. -4 Fire Distri t Legal Description Z_o T 5 9 Co I r 114 X Site Address (Please include street name, street number and city) 9 Z O Directions to site SO icx►ft '-T GI^ rtJ ^, M*% . ( -'' r'= ..-. N C"d r KS Cwk 02 ao u..v Uc.i -in AddscSs ©iv CLA 920 f4c Co 1rNs Will timber be cut and sold in parcel preparation?Yes Is property within 200'of Saltwater N Zm,_Lake IU o River/Creek 14 a Pond_ Wetland k o Seasonal Runoff No Stream N o Slopes or Bluffs N Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Ye TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDEN E SEASONAL ❑ Use of Building �LicSi c�c.:NCB Describe Work sT %, W D F. 'z" No. of Bedrooms..3_—No. of Bathrooms '•2. Square Footage- 1st Floor 2nd Floor 3rd Floor Basement Deck�S `1 6overed Deck Other Sq. ft. Garage Attached Detached Carport Attached Detached 9-4 MANUF URED H��E INFORMATION - Make fit+ Model Year I Length Width.% Serial NoO?_VLLBAS2S bN$(o_7 No. of Bedrooms No. of Bathrooms .— Type of Heat I«- CWC4A rchase Price Replacement Unit? es No Installer Name ; � � T Certification No. Q Z OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have-obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OFA PRAG SS INSPEC ION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X .�-G� O o- Date: ' 6 R E C E I V E D Ckvner/Owners Repre ntative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: SEPW 7nn6 DEPARTMENTAL REVIEW APP OVED DENIED NOTES Building Department Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee / Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee IVO EA F, Pre-Paid at Submittal Valuation $ TOTAL FEES