HomeMy WebLinkAboutBLD2024-01082 Slope Stabilization - BLD Inspections - 2/7/2025 GeoStabilization International 00, P: 855.579.0536 1 F: 970.245.7737 www.geostabiIization.com fieo5ta6111za .International® February 611, 2025 E�E,v Ea Mr. David Anderson FEB p� 2025 10 North Sundown Drive Street Hoodsport, Washington 98548 615 w Adder Project No. 244118WAON SUBJECT: AS-CONSTRUCTED ENGINEERING DOCUMENTS FOR 10 N. SUNDOWN DR. [PARCEL 423185000011] SLOPE STABILIZATION, LAKE CUSHAMAN, WA Construction Compliance Access Limited Construction "ALC" completed the installation of the north bluff stabilization system as shown in the project plans. The construction was performed with acceptable compliance to the design intent and specified project Special Inspections. Minor variations from the design are noted in the As- Constructed plans and will not affect the performance of the stabilization system. The variations are primarily geometric in nature, except for the removal of the severely deteriorated timber retaining structure and small amount of aggregate fill behind the system to restore the final grade of the backyard. Please find the As-Constructed plans attached to this letter. Thank you, GeoStabilization International, LLC Derrick Hayes", PE, GE Principal Engineer Licensed in OR GeoStabilization International,PO Box 4709,Grand Junction,CO 81502 Phone:855.579.0536 Fax:970.245.7737 Main Office Address: 543 31 Road,Grand Junction,CO 81504 WALL REPAIR PLANS 10 NSUNDOWNDRIVE LAKE CUSHMAN, HOODSPORT, WA CLIENT SHEET INDEX DA VID E. ANDERSON NO. DESCRIPTION rJY G01 COVER SHEET APPROXIMATE C-02 GENERALNOTES 2? PROJECT LOCATION „z LAT: 47.49 C-03 SITE PLAN LONG:-123.241 C-04 PROFILE VIEW tv £ tpgv C-05 SECTION VIEW C-06 SECTION VIEW C-07 SOIL NAIL DETAILS N GOB NAIL SCHEDULE W. E + v Ir 5 VICINITY MAP (NOT TO SCALE) AS-CONSTRUCTED REDLINES j 100%DESIGN SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO IONSUNDOWNDRIVE O8116124 ISSUED FOR REVIEW IFR O11=4 ISSUED FOR PERMIT 0 1 12/16/24 AS-CONSTRUCTED 1 1 FF N. SEc SHEET TITLE: 1�C'�pF a4Sy2�c,P COVER SHEET e T fien5ta6illzatlon Intematianaia y i 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA °p er 22024774 xoaummacun s�mso�.rrn�ue�aa�wnec anrm„n.s 0536 579, rwFct un.�vaavwenwr usasunou ena��wnnar ro eE DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET Phone:855. 1 Fax:970.245.7737 ��E`�yRAi.ENp�1�� o, n«nwrw,wnvmnanar�oFc.+,.rowrw,wner www.goostabilization.com DRH DRH 8116/24 171374296 244118WAON G-01 �S�ONALti�G CONSTRUCTION SEQUENCE/WORK SCHEDULE: OF TOP OF SHOTCRETE. f BARS SHALL NOT BE FORCED INTO THE DRILL HOLE.IN HOLES WHERE RESISTANCE THE CONTRACTOR WILL PROVIDE AND INSTALL THE SPECIFIED SOIL NAILS AND SLOPE IS ENCOUNTERED DURING BAR INSTALLATION,THE HOLES SHALL BE CLEAND AND SURFACE TREATMENT PER THE CONSTRUCTION DOCUMENTS.THE ANTICIPATED REINFORCING STEEL PLACEMENT: INSPECTED PRIOR TO REPLACING THE TENDON. CONSTRUCTION SEQUENCE IS AS FOLLOWS: !; REINFORCING SHALL BE PLACED SUCH THAT THE MINIMUM CONCRETE COVER IS E GROUT INSTALLATION METHODS MAY BE ADJUSTED UPON GSI ENGINEER APPROVAL PROVIDED AS SHOWN. BASED ON SITE CONDITIONS DURING INSTALLATION. 1. DELINEATE LIMITS OF STABILIZATION.NOTIFY LOCAL UTILITIES PROVIDERS TO ✓; REBAR WILL BE TIED TO THE WIRE MESH IN THE SHOTCRETE PORTION OF THE DRILL HOLES SHOULD BE VISUALLY INSPECTED FOR GROUT LOSS.SOIL NAILS LOCATE AND MARK POTENTIAL UNDERGROUND FACILITIES.DAYLIGHTING OF STABILIZATION SYSTEM.VERTICAL AND HORIZONTAL BARS WILL BE PLACED AS SHOWING SIGNS OF GROUT LOSS MAY BE FILLED BY PLACING A TREMIE GROUT PIPE UTILITIES IN POTENTIAL CONFLICT,AS NECESSARY. SHOWN IN THE CONSTRUCTION PLANS. INTO THE DRILL HOLE UNTIL IT REACHES THE GROUT COLUMN.GROUT WILL BE 2. PREPARE THE WORK AREA FOR STABILIZATION CONSTRUCTION. { NON-CONTACT SPLICES OF THE REBAR WILL NOT BE REQUIRED. PLACED UNDER GRAVITY PRESSURE UNTIL GROUT RETURN IS OBSERVED AT THE 2.1. PREPARE SITE ACCESS. SURFACE.DRILL HOLES SHOWING SIGNS OF MINOR GROUT LOSS MAY BE TOP 2.1 INSTALL TEMPORARY EQUIPMENT ANCHORS AS REQUIRED. BEARING PLATE PLACEMENT: FILLED. 2.3. PREPARE WORKING FACE BY INSPECTING AND REMOVING DELETERIOUS { 8-X 8-X 3/8'STEEL BEARING PLATES WILL BE PLACED OVER THE NAILS AND MATERIAL ATTACHED WITH A HEX NUT TO SECURE THE MESH AND REBAR DURING SHOTCRETE 2.4. PROTECT EXISTING HOME WITH PLASTIC SHEETING AND PLYWOOD AS NEEDED. PLACEMENT.IF THE SOIL NAILS EXTEND BEYOND THE HEX NUTS OR WELDED 3. MARK THE LOCATIONS OF THE PROPOSED SOIL NAILS WITH SURVEY MARKING PAINT. PLATES,THEY WILL BE TRIMMED. 4. INSTALLATION OF SOIL NAILS. 5. PLACEMENT OF GEOCOMPOSITE DRAIN STRIP. SHOTCRETE: 6. PLACEMENT OF BEARING PLATES,HEX NUTS,REINFORCING STEEL,AND ANY f SHOTCRETE MIX DESIGN SHALL COMPLY WITH THE REQUIREMENTS OF ACI 506.2. REQUIRED FORMWORK 'SPECIFICATIONS FOR MATERIALS,PROPORTIONING AND APPLICATION OF 7. GSI TO PERFORM SITE RESTORATION. SHOTCRETE',UNLESS OTHERWISE APPROVED BY GSI ENGINEER 7.1. REMOVE CONSTRUCTION DEBRIS F SET TIME CONTROLLING ADDITIVES(I.E.HYDRATION STABILIZERS,RETARDERS)MAY 7.2 EXPOSE AND REMOVE ANY TEMPORARY EQUIPMENT ANCHORS AT LEAST 24' BE USED PER THE MANUFACTURER SPECIFICATIONS AND UNDER THE DIRECTION OF BELOW FINAL GRADE. A GSI ENGINEER. HOUSE KEEPING: 4 SHOTCRETE MIX DESIGN MAY BE ADJUSTED BASED ON LOCAL SUPPLIERS, f THE SITE WILL BE ORGANIZED AND CLEAR OF ANY TRASH OR DEBRIS.ALL TRASH AVAILABILITY,AND SITEIWEATHER CONDITIONS. WILL BE PLACED IN A PROPER CONTAINER AND REMOVED AT THE END OF EACH WORK DAY. SHOTCRETE MIX DESIGN: F MINIMUM 28 DAY COMPRESSIVE STRENGTH:3000 PSI SAFETY: F TARGET WATER TO CEMENT RATIO:0.4 TO 0.5 F ALL SAFETY PLANS FOR LIFTING,HEARING,DUST CONTROL,PPE ETC.WILL BE IN TARGET SLUMP:3 TO 41NCHES PLACE AND FOLLOWED ACCORDINGLY.PPE INCLUDES SAFETY VEST,STEEL TOED TARGET GRADATION:ACI NO.2 OR AS APPROVED BY GSI ENGINEER SHOES,HARD HAT,SAFETY GLASSES,RESPIRATOR DURING DUST PRODUCING ACTIVITIES,AND GLOVES. SHOTCRETE APPLICATION: t; ALL FIELD PERSONNEL SHALL ATTEND SITE SPECIFIC ORIENTATION PRIOR TO BEING ON SITE,AS REQUIRED. ✓; SHOTCRETE WILL BE PLACED FROM THE LOWER PART OF THE AREA UPWARDS TO F, DAILY PRE/POST JOB BRIEFINGS WILL BE HELD AND DOCUMENTED;ALL ON SITE PREVENT ACCUMULATION OF REBOUND.THE NOZZLE WILL BE ORIENTED A PROPER PERSONNEL WILL BE REQUIRED TO REVIEW AND SIGN DISTANCE FROM AND APPROXIMATELY PERPENDICULAR TO THE WORKING FACE SO THAT REBOUND WILL BE MINIMAL AND COMPACTION WILL BE MAXIMIZED.CARE WILL QUAMY CONTROL SCHEDULE EMPLOYEE CERTIFICATIONS: BE TAKEN WHILE ENCASING REINFORCING STEEL AND MESH TO KEEP THE FRONT !•; ACI SHOTCRETE 14OZZLEMEN CERTIFICATION FACE OF THE REINFORCEMENT CLEAN DURING PLACEMENT OPERATIONS,SO THAT DESCRIPTION FREQUENCY REFERENCE/CRITERIA f; 10-HOUR OCCUPATIONAL SAFETY AND HEALTH TRAINING COURSE IN CONSTRUCTION SHOTCRETE BUILDS UP FROM BEHIND,TO ENCASE THE REINFORCEMENT AND DRH LOGS EVERY SOIL NAIL RECORD DATA PER SHEET o-oe SAFETY&HEALTH PREVENT VOIDS OR POCKETS FROM FORMING. 1; AMERICAN RED CROSS STANDARD FIRST AID TRAINING PROOF NAIL TEST 2 PRODUCTION NAILS,TEST FHWA 14-007,2015 f; AMERICAN RED CROSS BLOODBORNE PATHOGENS TRAINING:PDT GROUT MIX DESIGN: AFTER 48 HRS f; WATER(CEMENT RATIO=0.5 TO 0.6 MUD BALANCE READINGS ONCE EACH DAY OF SEE SHEET C-02&GOB FOR MIX SIZE AND TYPE OF NAILS: F, DENSITY RANGE:112.2-108.6 PCF (SPECIFIC GRAVITY) GROUTING DESIGN AND DATA LOG !; THE SOIL NAILS SHALL BE AS SHOWN IN THE CONSTRUCTION PLANS.INSTALL OF NO. PORTIAND CEMENT:TYPE LAW OR EQUIVALENT 6 SOLID THREADBAR TENDONS AS SHOWN UNLESS UNSTABLE HOLE CONDITIONS ARE ENCOUNTERED.T40/18 HOLLOW BAR SOIL NAILS ARE ACCEPTABLE AS ALTERNATIVE ANCHORS,IF UNSTABLE HOLE CONDITIONS ARE ENCOUNTERED. (PER 94#BAG OF CEMENT) 2; ALL ASSOCIATED ANCHOR HARDWARE SHALL HAVE A CAPACITY NOT BE LESS THAN MATERIAL WEIGHT VOLUME MIX RATIO THE FULL ULTIMATE CAPACITY OF THE BAR TENDONS USED. CEMENT 94 LBS 0.47 FT' i BAG(94#) ! WATER 47 TO 56.4 LBS 0.75 FT'TO 0.09 FT` 5.12 GALLONS TO 5.47 GALLONS ' FACING AND DRAINAGE SYSTEM: i { DRAIN STRIPS WILL BE PROVIDED AND INSTALLED BETWEEN THE SOIL NAILS PER NAIL INSTALLATION AND GROUTING: THE CONSTRUCTION DOCUMENTS,DRAIN STRIPS WILL BE CONTINUOUS AND ANY AS-CONS O UCTED REDLINES ALL NAILS SHALL BE TREMIE GROUTED CONCURRENTLY WITH PLACEMENT OF BARS SPLICES SHALL BE MADE WITH AONE-FOOT MINIMUM OVERLAP SUCH THAT THE 100%DESIGN FLOW OF WATER IS NOT IMPEDED. NO DRAIN STRIPS WILL BE LOCATED WITHIN 18' INTO THE DRILLED HOLES. SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 08/16/24 ISSUED FOR REVIEW IFR 10 N SUNDOWN DRIVE 08122124 ISSUED FOR PERMIT 0 12/16/24 AS-CONSTRUCTED I `�� 31AWASA,�9P f SHEET TITLE: I GENERAL NOTES y Gen5tablllzatlo Intematinnal� 'A 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA G(�2,2�024774 m ru�cr�cum s�sou=Lrv°n me use°F a+r c°rw.ecrron rnrr ms DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHE�:j Phone:855.579.05ta l Fax:970.245.7737 �'�FAL GG1�44 www, eostabilizaGon.com f 9 fONAL�I, cousnucre°wo su�rmeFn�rrn°�rrew°E. °Noeaw`ca„:..c as JAG DRH DRH 8/16/24 171374296 244118WAON % -,y PROPOSED SHOTCRETE WALL STA 0+00 TO STA 0+55t S�� .i OF r 5 :1 119towards IQ 4p;t t 10 €€1 �sE uli3�.�t `ry 9 BUILD-OUT AREA ! ESTIMATED QUANTITIES PAY ITEM QTY QTY UNIT js�9. Cb� d, . kSE enhal uarozv SOIL NAILS zs 19 EA �► -ti ,� �k� i STEEL PLATES 25 19 EA FURNISH 6 INSTALL 550 440 SF SHOTCRETE t' `"^^•�„ STRIP DRAIN 83 80 LF t i } Lot 0 1a zo r 1 1, *► _ _m AS-CONSTRUCTED REDLINES ` : trt c:tt ` 100%DESIGN 1 . SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 10 N SUNDOWN DRIVE 08/16/24 ISSUED FOR REVIEW IFR 08/22/24 ISSUED FOR PERMIT 0 12/16/24 AS-CONSTRUCTED 1 A. SEC SHEET TITLE: ,Q pF aASH�9.p SITE PLAN 6eo5ta6iiizatl�intematlonal� � c7 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA TMv `vmcrrN w car�crnn wm—To�s DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET Phone:855.579.0536 1 Fax:970.245.7737 ���.�URALF-N�'`��{w n ..... :� wWW.geostabilization.com �S�ONAVt rman�oa�ecoKnucraa JAG DRH DRH 8/16/24 171374296 244118WAON C-03 EXISTING STRUCTURE NOTES: PROTECT FROM DAMAGE THERE WAS NO PRACTICAL WAY LEAVE EXISTING TIMBER STRUCTURE ESPECIALLY OVERSPRAY TO STABILIZE THE EXISITNG�IN-PLACE AS PRACTICAL TIMBER WALL IN-PLACE VARIES MIN.5' EXISTING TO BE REMOVED BY OWNER REPLACE MATERIAL LOST WHEN TIMBER WALL IS REMOVED WITH A AGGREGATE EXIST I FILL BE I REM ED 6"NOMINAL REINFORCED SHOTCRETE ( o PLACE AGAINST SOIL NAIL IfXPOSED SOIL 9 b FACE Q A EXISTING TIMBER WALL C-07 15"15* Up TYP 1BEDAgENTLFNGThI TyP 15' Encountered very dense material;revised anchor lengths based on global stability modeling indicating shorter anchors are appropriate. TYPICAL SECTION ~ SCALE:1"=5' AS-CONSTRUCTED REDLINES 100%DESIGN SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 10 N SUNDOWN DPJVE OB11624 ISSUED FOR REVIEW IFR 0822f24 ISSUED FOR PERMIT 0 1211624 AS-CONSTRUCTED 1 4F A. SEC SHEET TITLE: '�4'�O4 NpSyl q� IIIIII SECTION VIEWS c� 6en5tabilizaiion imernational� he y 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA 'p�22024n4 Phone:855,579.0536 1 Fax:970.245.7737 o rT G 0 snoxc vovnanxr,u�.wsasu,wu yaw"�.�oua.+or to eE DRAWN BY: TDRH IGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET �Of t/RALfiN�G`� .m rou r onc"ono�wu w.vnn wr srcarcwMonr�nw or www.goostabilization.com BjON AL B� �«re no �'rn`"Rs"� oua JAG DRH 8/16/24 171374296 24411BWAON C-05 ALL DRIILING ENCOUTERED NOTES: VERY DENSE GRAVELLY ALL DISTANCES ARE SLOPE DISTANCE SILTY SAND TO SANDY UNLESS NOTED OTHERWISE. GRAVELLY SILT NOTIFY ENGINEERING IF COMPETENT SOIL IS NOT ENCOUNTERED WHILE APPROXIMATE DRILLING. APP XJhQAQ6kTi LOCATION OF !; PROTECT EXISTING STAIRWAY. O EXISTING TIMBER EXISTING STAIRWAY MODIFICATION OF SOIL NAIL LOCATION AND ORIENTATION ACCEPTABLE PER REMOVED DIRECTION FROM GSI ENGINEERING. REPLACE MATERIAL LOS T WHEN TIMBER WALL IS REMOVED WITH A AGGREGATE TEST NAIL INFORMATION: J FILL BONDED LENGTH:18(FT) <o -N UNBONDED LENGTH:3(FT) Z a o a HOLE DIAMETER:4(IN) all �- 1 SHOTCRETE 1,�. ❑¢ BOND STRENGTH:1,000(LBIFT) m u~i 6'-0" FACING PROTECT EXISTING w CORRUGATED DRAIN r ❑ ❑ 7 a 18 'V 9 ,! 1❑0 4 io o z` 1 l OJT ❑ ❑16 7 Cl ❑ IR 13 14 1 u' A ❑ ❑ ❑ G-07 23 24 25 SOIL NAIL EXTENDED GEOCOMPOSITE STRIP DRAIN BELOW SHOTCRETE WALL,TYP QLEGEND NOT REQUIRED DUE ElUP TO 20'-0-SOIL NAIL TO ACTUAL SLOPE GEOMETRY j TYPICAL PROFILE SCALE:V=5' AS-CONSTRUCTED REDLINES 100%DESIGN SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 10 N SUNDOWN DRIVE 08/1624 ISSUED FOR REVIEW IFR O8/=4 ISSUED FOR PERMIT 0 I 12116/24 AS-CONSTRUCTED 1 4 A SEC iSHEET TITLE: INS, pF WAS 1I! PROFILE VIEWS y T 6eo5tabilizatim�I�Kemationai� y 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA '��zzozana co�cm�TMn r� p�t�w DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT Phone:855.579.0536 Fax:970. NUMBER: PROJECT NUMBER: SHEET 245.7737 2 RALFN www.goostabilization.com �S70NALE�G mw°E0�°c�,uo.sm" ie® aa'm �wm`ai JAG DRH DRH 8/16124 171374296 244118WAON C-04 NOTES: WORKING FACE(SCARP)PREPARATION: CLEAR WORKING FACE OF EXCESSIVELY LOOSE MATERIALS AND TRIM ALL VEGETATION FLUSH. THE WORKING FACE SHALL HAVE A RELATIVELY UNIFORM AND PLANAR SURFACE ALLOWING FINAL FACING TO BE HAVE A POSITIVE BATTER. 6"NOMINAL REINFORCED SHOTCRETE SOIL NAIL SLOPED BENCH FOR POSITIVE DRAINAGE Z� A Up 20 C-07 BED&z/vTCENGTH �p 15°15° 15, TYP Encountered very dense material;revised anchor lengths based on global stability modeling indicating shorter anchors are appropnate. a TYPICAL SECTION I A SCALE:1'=5' AS-CONSTRUCTED REDLINES 100%DESIGN SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 10 NSUNDOWNDRIVE 08116124 ISSUED FOR REVIEW IFR 08/22/24 ISSUED FOR PERMIT 0 ' 12/16/24 AS-CONSTRUCTED 1 A Sb' arm SHEET TITLE: WASH SECTION VIEWS h 6Ho5[atrilizaiion InCernatinnal�' 2 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA �9 22024774 n roT soev Fa+ use or oa in ca+r.Ecrior_T0 $ DRAWN BY: DESIGNEDBY: CHECKEDBY: DATE: PURSUIT NUMBER: PROJECTNUMBER. SHEET Phone:855.579.0536 Fax:970.245.7737 �'r�`GCTURAL60G���,�cV na„ www.geostabilization.com �SIONAIL a.,=T« v JAG DRH DRH 8/16/24 171374296 244118WAON C-06 NOTES: (SEE NOTE 4) 1. ALL SOIL NAIL HEAD HARDWARE SHALL BE EPDXY COATED. 2. LAP SPLICE LENGTH 2.1. NO.4 REBAR-24"MINIMUM WALERS(REBAR) DRAIN STRIP 3. WELDED WIRE MESH TO HAVE A MINIMUM OF 8"OVERLAP(2 SQUARES OVERLAP FOR 4 x 4 MESH). STEEL PLATE TO BE WET SET 4 x 4-W2.9 x W2.9 WELDED 4. REBAR CHAIRS OR EQUIVALENT TO WIRE MESH(ASTM A185) ® BE USED TO ENSURE SUFFICIENT WELDED WIRE MESH (2)36"LONG N0.4 GRADE 60 BARS CONCRETE COVER BETWEEN VERTICAL EACH SIDE OF NAIL GROUND SURFACE AND REINFORCEMENT.2 TO 3 DOBIES PER (2)CONTINUOUS N0.4 5'x 10'SHEET OF MESH,TYPICAL. GRADE 60 BARS HORIZONTAL 5. HORIZONTAL WALERS ARE BIRDS BEAK 8"x 8"x 3/8"A36 STEEL PLATE CONTINUOUS (SHOTCRETE OR GROUT BACKFILL) 6. INSTALL CENTRALIZERS ALONG THE ct LENGTH OF THE SOIL NAIL AT TYPICAL NAIL HEAD INTERVALS NOT GREATER THAN 8' PERPL FROM EACH OTHER.THE �ENG�N HEX NUT CENTRALIZERS ON THE ENDS OF THE NAIL SHALL BE INSTALLED 1.5'FROM PER PLAN THE COLLAR OF THE HOLE AND THE BEVELED WASHER BOTTOM OF THE HOLE. 1" MIN 6"NOM.3,000 PSI SHOTCRETE UNDISTURBED GUN FINISH 75 KSI-NO.6 EPDXY COATED THREADED BAR(ASTM A615) REBAR CHAIRS OR SIMILAR 3,000 PSI NEAT CEMENT GROUT (SEE NOTE 3) CENTRALIZERS 4"H DRILLHOLE MIN. MIN i STANDARD DETAIL ~ SCALE:1"=1' AS-CONSTRUCTED REDLINES 100%DESIGN SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 10 N SUNDOWN DRIVE 08/16/24 ISSUED FOR REVIEW IFR 08/22/24 ISSUED FOR PERMIT 0 dV ! 12/16/24 AS-CONSTRUCTED i j SHEET TITLE: OF WAS 9� !t SOIL NAIL DETAILSAA424774 �cT 6eo5ia6ilization internationai�' y 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USAF TMeowmwnrw.e�sa�wn EusEaronncw4rnwrmm ns Phone:855.579.0536 Fax:970.245.7737 rAu cr woawvwenwrxsaiw,nw a"ow �wunor row DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET ! OAF�7'f/RALE bey�F www.geostabilizaGon.com rS�ONALti�G w a wc�o woa of na.ma re� �o�cw�cran JAG DRH DRH 8/16124 171374296 244118WAON C-07 DATE EMBEDMENTLENGTH(ft) NAIL ID MUD BALANCE TESTING-SPECIFIC GRAVITY(ASTM D4380) DRILLED GROUTED SOIL ROCK 1 9/18/2024 9/19/2024 15 0 2 9/18/2024 9119/2024 15 0 DATE NAIL ID' READING-SP.GR.(1.75-1.84,TYP GSI)" 3 9/18/2024 9/19/2024 15 0 919 YES 4 9/23/2024 9/24/2024 15 0 9 24 YES 5 9/23/2024 9/24/2024 15 0 9/26 YES 6 9/23/2024 9/24/2024 15 0 9l27 YES 7 9/23/2024 9/2412024 15 0 1011 YES e 9/25/2024 9/2612024 15 O 9 9125/2024 9/26/2024 15 0 'APPROXIMATE NAIL NUMBER GROUTED WITH SAMPLED BATCH. 10 9/25/2024 9126/2024 15 0 SAMPLE SHALL BE TAKEN FROM END OF GROUT HOSE. 11 9/25/2024 9/26/2024 15 0 12 9/26/2024 9/27/2024 15 0 13 1 9126/2024 9/2712024 15 0 14 9/27/2024 9/27/2024 15 0 15 9127/2024 9/27/2024 15 0 16 9/27/2024 9/27/2024 15 0 17 9/30/2024 10/1/2024 15 0 19 /3012 24 10/1/2024 15 0 19 913012024 1011/2024 15 0 20 NOT INSTALL zt IN — — — z2 1 T D — 23 IN - - 24 1 NOT INSTALL D — 25 1 NOT N TALL D — i i AS-CONSTRUCTED REDLINES 100%DESIGN SHEET REVISIONS PROJECT NAME: DATE DESCRIPTION NO 10 N SUNDOWN DRIVE 0811624 ISSUED FOR REVIEW IFR 082224 ISSUED FOR PERMIT 0 104 1211624 AS-CONSTRUCTED 1 A. S F EC SHEET TITLE: 1 of WAS P NAIL SCHED ULE y fien5taW11zaLim�I�ematlonal� '`e y 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA o zz'ozana »o,` Er8O1F'.a.� To�"�iv�nwivarorarTe�' DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSURNUMBER: PROJECT NUMBER: SHEET Pine: www.gosta l FBx:970.245.7737 ���.�bgA�ENo��t�w www.geostabilization.com �SrONALE�G JAG DRH DRH 8/16/24 1 171374296 244118WAON C-08 Mason County Permit Document Reviewed for Code Compliance BLD2024-01082 Mason County Building Department v' special Inspection Requirements MASON COUNTY l COMMUNITY SERVICES BLD2024-01082 Anderson Slope 10 N. Sundown Drive, 423185000011 Permit Number Project Title Project Address/Parcel Number Applicants of projects requiring Special Inspection or Testing per Chapter 1704&1705 of the International Building Code, as amended by Washington State. Please acknowledge and return this form to the Mason County Permit Center. THESE INSPECTIONS ARE NOT PERFORMED BY THE BUILDING DEPARTMENT AND MUST BE PERFORMED BY QUALIFIED SPECIAL INSPECTORS, HIRED BY THE OWNER AND APPROVED BY THE COUNTY PERMIT CENTER. Individuals certified in a special inspection category by Washington Association of Building officials(WABO)or individuals employed by a recognized testing laboratory and under the direct supervision of a Registered Professional Engineer are typically considered qualified at the discretion of the local jurisdiction having authority for enforcement. BEFORE A PERMIT CAN BE ISSUED: The Owner or his/her representative, on the advice of the responsible Project Engineer or Architect, shall fill out completely, sign and submit two (2) copies of the attached "Structural Tests and Inspection Schedule"to this Department for review and approval including any requirements related to the Mason County Municipal Code. The Owner, General Contractor, and Inspection/Testing Agency, where applicable, shall also acknowledge the following conditions applicable to Special Inspection and/or Testing. 1. Inspection/Testing Agency shall submit names and qualifications of on-site Special Inspectors to the Building Inspection Permit Center for approval PRIOR TO PERMIT/S BEING ISSUED. 2. All Special Inspections shall be noted on the approved plans or attached approved documents. 3. All special inspections shall be approved by the County or as recommended by the Engineer of Record (EOR). 4. It is the responsibility of the General Contractor to review County approved plans for additional inspection or testing requirements that may be noted or required per IBC as noted on approved plans. 5. The General Contractor is responsible for proper notification to the Inspection/Testing Agency for items listed on this form. 6. Special Inspectors shall provide detailed reports on company letterhead to the Building Inspector of all required inspection activities. These may also be provided when the inspector visits the jobsite for the scheduled inspection but must be completed before the subject of inspection is approved by the building inspector. 7. Copies of all ongoing laboratory and testing reports shall be sent directly to the Building Inspector by the Inspection/Testing Agency or other responsible party within a reasonable time to test results. 8. BEFORE A CERTIFICATE OF OCCUPANCY APPROVAL CAN BE ISSUED: The Inspection/Testing Agency shall submit a FINAL REPORT LETTER stating that all items requiring testing and inspection have been fulfilled and reported and a final inspection report shall be provided. A copy of the statement is to be maintained at the jobsite for the Building Inspectors review prior to final inspections. Page 1 of 4 r Special Inspection Requirements MASONCOUN'IY COMMUNM SIRVICrs Am ACKNOWLEDGEMENTS Prior to issuance of a building permit, the Owner, on the advice of the Project Engineer or Architect, shall complete,sign,and submit this form to the County Permit Center. Declaration of Owner I, as the owner of the project,declare that the testing agency firm/s or individual/s listed herein are hired by me to perform "Special Inspections" and/or"Structural Testing" in accordance with the provisions of the International Building code(IBC)Chapter 17. Owner(print) Owner(Signature) (date) Declaration of Registered Professional Architect/Engineer I, as the design professional in responsible charge of the project listed herein, declare that the special inspection listed herein are required for this project in accordance with the provisions of the International Building Code (IBC) Chapter 17. Jeff A. Segar, PE, SE A' SEC N A Sys Architect/Engineer(print) �e o Architect/Engineer Stamp/Signature(date) ` Digitally signed by Jeff Segar �?G 22024774 IQ DN:C=US,E=Jeff.Segar@gsi.us, �� cTURALE�V�� O=GeoStabilization International, f CN=Jeff Segar [late:2024.09.09 13:18:18-05'00' Testing Agency Name/Contact Building Department spoke with owner on 9/10/24. info: Owner stated FOR to conduct special inspection. See attached special inspection schedule attached The Special Inspection/Testing Agency listed above must have a current Portfolio of Qualifications on file with the County prior to performing work. Declaration of the General Contractor I, as the General Contractor of the project, agree to comply with the"Contractor Responsibility"items noted herein. General Contractor(print) General Contractor Signature (date) Page 2 of 4 Special Inspection Requirements r MASON COUNiY .: - COMMUNM SCRVICFs See attached Special Inspection Table Required Special Inspections International Building Code; Chapter 17: A completed and signed copy of pages 1 through 4 of this form shall be submitted to the "Permit Center" prior to building permit approval. Engineer shall check the applicable items: ❑ Special inspection of fabricated items 1704.2.5 ❑ Submittals to the building official 1704.5 ❑ Structures over 75' in height located in Seismic Design Category D, 1704.6.1 ❑ Structures classified as Risk Category III or IV located in Seismic Design Category D, 1704.6.1 ❑ Steel construction&structural Steel 1705.2.1 ❑ Cold form steel deck 1705.2.2 ❑ Open-web steel joists&girders 1705.2.3 ❑ Cold form steel trusses spanning 60 feet or greater 1705.2.4 ® Concrete construction 1705.3 &Table 1705.3 Q Shotcrete 1705.3 ❑ Welding of reinforcing bars 1705.3.1 ❑Material Tests 1705.3.2 ❑Masonry Construction 1705.4 ❑Empirically designed masonry,glass unit&masonry in Risk Category IV 1705.4.1 ❑Vertical masonry foundation elements 1705.4.2 ❑Wood construction 1705.5 ❑High Load Diaphragms 1705.5.1 ❑Metal-plate connected wood trusses spanning 60 feet or greater 1705.5.2 ❑ Soils 1705.6 &Table 1705.6 ❑Driven deep foundations 1705.7&Table 1705.7 ❑ Cast in-place deep foundations 1705.8 &Table 1705.8 ❑Helical pile foundations 1705.9 ❑Fabricated items 1705.10 Page 3 of 4 Special Inspection Requirements MASON COUNTY COMMUNM SGRV]C1:5 " See attached Special Inspection Table ❑ Special inspections for wind resistance 1705.11 ❑ Structural wood 1705.11.1 ❑Wind resisting components 1705.11.3 ❑ Cold formed steel light frame 1705.11.2 ❑ Special inspection for seismic resistance 1705.12 ❑ Special inspection for structural steel per 1705.12.1 ❑ Seismic force-resisting systems 1705.12.1.1 ❑ Structural steel elements 1705.12.1.2 ❑ Special inspection for structural wood per 1705.12.2 ❑ Special inspection for cold-formed steel per 1705.12.3 ❑Designated seismic systems 1705.12.4 ❑Architectural components 1705.12.5 ❑ Plumbing,mechanical&electrical components 1705.12.6 ❑ Storage racks 1705.12.7 ❑ Seismic isolation systems 1705.12.8 ❑ Cold-formed steel special bolted moment frames 1705.12.9 ❑ Testing for seismic resistance 1705.13 ❑ Structural steel 1705.13.1 ❑ Seismic fore-resisting systems 1705.13.1.1 ❑ Structural steel elements 1705.13.1.2 ❑Nonstructural components 1705.13.2 ❑ Designated seismic systems 1705.13.3 ❑ Seismic isolation systems 1705.13.4 ❑ Sprayed fire-resistance materials 1705.14 ❑Physical and visual tests 1705.14.1 ❑ Structural member surface conditions 1705.14.2(1705.14.3 through 1705.14.6.3) ❑ Mastic&intumescent fire-resistance costings 1705.15 ❑Exterior insulation&finish systems (EIFS) 1705.16 ❑Fire-resistance penetrations and joints 1705.17 ❑Penetration firestops 1705.17.1 ❑ Fire-resistant joint systems 1705.17.2 ❑ Testing for smoke control 1705.18 ❑ Testing Scope 1705.18.1 Page 4 of 4 dIn Project Quality Inspection and Testing Anderson Slope: 10 N. Sundown Drive Parcel: 423185000011 244118WAON To whom it may concern, The following table shall be used during construction for the above-entitled project. SPECIAL INSPECTION REQUIREMENTS TYPE FREQUENCY REFERENCE IBC CONTINUOUS PERIODIC STANDARDS STANDARDS Submittals to Building Officials: - - - 1704.5 Shotcrete mix design Verify use of required mix design - Prior to placement ACI 318 1904.2, 1908.1 Inspect shotcrete placement - Initial placement ACI 318:26.5 1908.1 technique Shotcrete Panel:24"x24"x6" - Initial placement ASTM 1140M - Shotcrete compressive strength - 28 day ASTM C39 Soil Nail grout mix design:mud - Once per day during ASTM D4380 - balance drilling Soil nail testing - X By Engineer • COBALT Cobalt Geosciences,LLC GEOSCIENCES P.O.Box1792 North Bend,WA 98045 August 30,2024 David Anderson danderson@masongeneral.com RE: Geotechnical Addendum Proposed Wall Mitigation io N.Sundown Drive Hoodsport,Washington In accordance with your authorization, Cobalt Geosciences, LLC has prepared this letter to discuss the wall construction near the residence. Based on our understanding and current site conditions, it is our opinion that this is an emergency repair which should be completed as soon as possible, ideally prior to the end of the current dry season. Continued erosion and peel off could adversely affect the residence in a relatively short period of time. The planned pin pile and helical anchor tieback wall is the most practical and feasible option to help mitigate soil movements in this area, primarily due to access considerations. A typical mitigation system would include a deep soldier pile wall between the residence and slope; however,this is not feasible due to a lack of access. Sincerely, Cobalt Geosciences, LLC P�ZHONY,y tWash ?r WA t°.'6+GrwRvW"wkM►q "" .�0 `C,' 2513 qop 54896 <v ��e C ISTEREQ d e 0 `r'�` 8/30/2024 Phil Haberman,PE,LG,LEG Principal REVIEWED FOR CODE COMPLIANCE MASON COUNTY BUILDING DEPARTMENT www.cobaltg_eo.com (2o6)331-1097 Pc A0A if 4 J -!0-GX/i INSIGHT GEOLOGIC, INC. h .x June 14, 2017 RECEIVED JUL 2 12017 David Allison 10 North Sundown Drive 615 W. Alder Street Hoodsport, Washington 98548 Report Slope Failure Investigation 11 Allison Property r�lllU� 10 North Sundown Drive JU lolrnvft,,�c) Hoodsport, Washington Project No. 929-001-01 INTRODUCTION' Insight Geologic is pleased to provide our report of our geotechnical investigation of the failure of a slope on your property located at Lake Cushman, property address 10 North Sundown Drive, Hoodsport, Washington. The site location is shown relative to surrounding physical features in the Vicinity Map, Figure 1 and Site Map, Figure 2. During our reconnaissance of the site,we observed that the northwest portion of your property leading down to the shore of Lake Cushman had failed resulting in separation and distress of a wooden staircase down to the lake shore. This failure appeared to extend to the east and west along the shoreline, affecting adjacent properties. A retaining structure, consisting of wooden posts and board lagging, has been constructed part-way up the slope, but appears to be failing. Based on our limited observations, the slope appears to be composed of sand and gravel with dense silt or clay at about beach level. Our services were conducted in general accordance with our proposal dated and authorized on March 2, 2017. SCOPE OF SERVICES The purpose of our services was to evaluate the subsurface conditions in the area of the failure, develop an opinion regarding the contributory factors and mechanism of soil failure, and provide recommended alternatives for mitigation and repair. We conducted the following tasks: 1. Review readily available published literature regarding the geology in the area of the site. Our review included published reports, as well as water well logs to develop an understanding of site geology. 2. Conduct a site reconnaissance to mark boring locations and map the features of the landslide down the slope, and evaluate upslope features which may be contributory to the failure. 3. Provide for the location of subsurface utilities at the site. We utilized the "One Call" reporting system to perform this task. 1015 EAST 4TH AVENUE, OLYMPIA, WASHINGTON 98506 PHONE: 360.754.2128 FAX: 360.754.9299 Allison Property Slope Failure Investigation Report June 14, 2017 4. Evaluate the subsurface conditions at the site by drilling two (2) exploratory borings in the area of the soil failure using hollow-stem auger drilling techniques. The borings were completed to the depth of 71.5 feet below ground surface (bgs). 5. Representative soil samples were collected at intervals of approximately 2.5 feet during drilling. Blow counts, which provide an indication of the relative density of the soil, were collected at each sampling interval. 6. Prepare detailed logs of the soil encountered in each boring on field logs. Soils were classified in general accordance with the Unified Soil Classification System. 7. Conduct field testing on recovered samples to include penetration resistance and undrained shear strength. 8. Provide geotechnical analysis of soil samples, as needed. Laboratory testing included grain-size analysis. 9. Utilized the field and laboratory data as input to the Slide 6.0 slope stability modeling program and conduct an analysis of slope stability. 10. Evaluated slope repair options and select the best two options as input into the slope stability model. Options resulting in a factor of safety (SF) less than 1.5 were rejected. 11. Prepared a report summarizing the results of our evaluation and providing our opinion as to the mechanism and contributory factors for the failure at the site. Our report has included detailed boring logs, laboratory results, field testing results, and geologic and hydrogeologic cross sections of the property. We have included our recommendations for mitigation and repair of the slope failure. FINDINGS SITE GEOLOGY The subject site is located approximately 7.5 miles northwest of Hoodsport, along the east shore of Lake Cushman. The property is bounded by Lake Cushman to the northwest, North Sundown Drive to the southeast and residential properties to the southwest. The property to the northeast remains undeveloped. The northwest third of the property is a steep slope that descends to the shore of Lake Cushman, with slopes standing at approximately 80 to 100 percent. This slope extends to the northeast and southwest and forms the southeast side of an inlet to Lake Cushman. The slope has recently failed with the failures extending along the slope and past the property boundary. The property is currently developed with a single-family residence situated on the upland portion of the property, southeast of the steep slope. The site is otherwise vegetated by native vegetation and trees. Detailed geologic maps show the area containing the property as glacially derived Quaternary sediments, which are described as ice contact deposits, but interpreted as the end moraine for the Vashon Puget lobe. The soils are generally described as pebbly sands and gravels with varying quantities of silt that were deposited in association with stagnant ice features such as kettles, hummocky topography, eskers, and outwash channels. Lodgment and ablative tills have not been found near the project location. An existing landslide deposit was identified by the Washington State Department of Natural Resources along the same steep slope to the northeast and adjacent to the project site. These sediments are well consolidated in this area and appear to have been overridden FILE No. 929-001-01 2 Allison Property Slope Failure Investigation Report June 14, 2017 and compacted by later glacial ice. Generally, Vashon Age ice contact deposits in this area are mapped from several to tens of feet in thickness. EXPLORA'-'")RY BORING" Insight Geologic contracted with Bortec, Inc. to provide drilling services for two borings located in the area of interest above the area of the failure. The borings were drilled using a track-mounted hollow stem auger drilling rig to the depth of 71.5 feet bgs. This termination depth was suitable as soils located within the lower 11.5 to 12.5 feet of the borings were consistent with the silt material located at the base of the slope at the shore of Lake Cushman. Boring B-1 encountered approximately 4.5 feet of dense, brown, poorly-sorted fine to coarse sand with gravel and silt (SP-SM), overlying 25 feet of dense to very dense, brown, poorly-sorted fine to coarse sand with gravel (SP). At a depth of 29.5 feet, the soils graded to a dense, brown, poorly-sorted fine to coarse sand with silt (SP-SM) before grading to a medium dense to dense, brown, silty fine sand (SM) at a depth of 40 feet bgs. Underlying the silty sand at a depth of 59 feet and continuing to the base of the boring at a depth of 71.5 feet, we encountered very stiff to hard, brown, sandy silt(ML). The upper 28.5 feet of boring B-2 generally consisted of medium dense to very dense, brown, poorly- sorted fine to coarse sand with gravel and silt(SP-SM), and dense to very dense, brown, poorly-sorted fine to coarse sand with gravel (SP) in interbedded units between 5 and 10 feet in thickness. Underlying these upper units, soils were generally consistent with boring B-1. Groundwater was initially encountered at a depth of 35 feet in boring B-1 and 30 feet in boring B-2, within the poorly graded sand with silt unit. Detailed logs of the borings are contained in Attachment A and a geologic cross section is provided in Figure 3. LASURA i OHY ANALYSES We conducted laboratory analyses on representative boring samples to determine soil classification and grain-size distribution. Our laboratory analyses were performed in our soils laboratory and conformed to the appropriate ASTM methodology. The laboratory results are presented in Attachment B. SLOPE STABILITY MODELING We utilized the commercial software program Slide 6.0 to evaluate the stability of the slope in both current conditions and evaluating various remediation scenarios. We used a nominal unit weight for the sand and gravel unit, and increased cohesion due to the apparent glacial consolidation. Additionally, we modeled a layer of loose, slide debris material over the underlying sand and gravel. We used nominal values for cohesion and internal friction angle. A groundwater table was simulated across the units, which extended to the slope face and down to the base of the slope. We utilized both the Bishop's and Janbu methods to evaluate existing slope stability and found the factor of safety(SF)to be about 1.0,which corresponds to our assessment of the slope and its current, failed condition. Our investigation at the site also determined that the face of the slope consists of FILE No. 929-001-01 3 Allison Property Slope Failure Investigation Report June 14, 2017 slide debris. Without the installation of an engineered system to manage water seeping to the slope face, the soil will continue to fail. The modeling results are contained in Attachment C. We then modeled the slope using a dewatering system to reduce the water table and increase upper soil strength. The resulting model indicated that the minimum failure surface had an SF of 0.7, which occurs in the sloughed material along the face of the slope. The factor of safety increases with depth along the face of the slope and is generally above 1.0, which indicates stability. The results of the modeled mitigation alternative are shown in Attachment C. We have conducted an investigation of the soil failure on the northwest side of the residence located at 10 North Sundown Drive in Mason County, Washington. The property is located on a bluff overlooking an inlet of Lake Cushman. The slope has failed, resulting in separation and distress of a wooden staircase down to the lake shore with the failure extending parallel along the bluff face. Additional failure is possible, resulting in additional loss of property and possibly structures. We investigated the property by drilling two exploratory borings, conducting laboratory analyses on selected soil samples from the borings, and using the collected information to develop a model of slope stability. The results of our investigation indicate that the landslide area is underlain by dense to very dense, sand to sands with silts, that increase in silt content until reaching very stiff to hard silts at a depth of approximately 60 feet bgs. The sand material appears to be end moraine deposit that has be subsequently overridden by glacial activities and compacted. Groundwater was encountered between 30 and 35 feet bgs at the time of our investigation during the spring season. Based on the results of our evaluation, it is our opinion that the slope has failed due to groundwater flow to the face of the bluff in sand and gravel material. It is likely that the significant winter precipitation caused an increase in groundwater flow within this layer, resulting in failure of the overlying soils. RECOItI PIENDATIONSE We recommend the installation of a dewatering well or wells at the front of the property near North Sundown Drive. The dewatering system is used to lower the local groundwater levels within the hillside and reduce hydrostatic forces at the face of the slope. We recommend the installation of two dewatering wells, drilled to the underlying clay layer at about 60 feet bgs. The pumps within the wells would be connected to level-sensing switches, which would activate the pumps when groundwater levels rose to a certain elevation within the well bores. Extracted water would be pumped down the slope to the lake for discharge or into a storm drain at the road, if one is available. Horizontal drains could also be used at the site to dewater and stabilize the slope, however, equipment access to the slope face would be difficult for installation of the drains. A horizontal drain system consists of a series of horizontal pipes drilled back under the property to collect groundwater and convey the water to the lake. Using this system, groundwater levels can be effectively lowered within the slide mass with groundwater draining by gravity. We would be pleased FILE No. 929-001-01 4 Allison Property Slope Failure Investigation Report June 14, 2017 to prepare design documents for your selected mitigation alternative and prepare a cost estimate for implementation. LIM fA[IONS We have prepared this report for use by David Allison and his authorized agents regarding the soil failure of the slope on his property located at 10 North Sundown Drive in Mason County, Washington. Within the limitations of scope, schedule and budget, our services have been executed in accordance with generally accepted practices in the field of geotechnical engineering in this area at the time this report was prepared. No warranty or other conditions, expressed or implied, should be understood. Please refer to Attachment D titled "Report Limitations and Guidelines for Use" for additional information pertaining to use of this report. We appreciate the opportunity to be of service to you on this project. Please contact us if you have questions regarding the work performed or require additional information. Respectfully Submitted, WaBh INSIGHT GEOLOGIC, INC. �Q ipY pCdo�t a. BIG William E. Halbert L.HG., L.E.G. A'sed Ggo�o Principal William E. Halbert FILE No. 929-001-01 5 FIGURES - — —_ —Z 4 C � <J i +---4 O L Y M—P+C ,:.« 1+-A T O N A l 1. F O• 12 - I TE as N . :. 1 , 7• � Sh i t MqN � 1 SOURCE: TERRAIN NAVIGATOR HOODSPORT, WASHINGTON 7.5 MINUTE QUADRANGLE Year1985 SCALE:,:24000 ALLISON PROPERTY MASON COUNTY,WASHINGTON Figure 1 INSIGHT GEOLOGIC. INC. Vicinity Map ------------- 04;UO;-� 'A '11 e , v 7%4 iL 47, '! ' - ss �. -L . }."` y? , `' a+ •+�{ ^ems ar• i:.* ?�� �w�.• 'a. `mot �y Y�j� +'� 4� v M.-jf� y'�AA I 'V-2 ac r SOURCE: GOOGLE _AR'H LEGEND: I B-1 APPROXIMATE BORING LOCATION — — APPROXIMATE PROPERTY BOUNDARY SCALE: 1'=60' ALLISON PROPERTY MASON COUNTY,WASHINGTON INSIGHT GEOLOGIC. INC. Figure 2 Site Plan DECK RESIDENCE DRIVEWAY B-Y SUNDOWN OR6POTUTCH DR � 4------------------?----------------`SP-w ------ ----------------------- ------2G0 SP SP-SM - -- ------------- - v--------------------- oY SP-SM 270 'PNDSJO SM SM -_- UKE CUSHMAN -- ------------- ML FEET , T-i 20 0 10 IO 10 BO f00 1 W 1� 1!0 200 220 210 NORTH SOUTH VIEW NORTHEAST ..?� ALLISON PROPERTY rrc r.0 MASON COUNTV.WASHINGTON —-�—� — Figure 3 ixvwrt Geaowc.K Cross Section ATTACHMENT A EXPLORATION LOGS SOIL CLASSIFICATION CHART MAJOR DIVISIONS SYMBOLS GROUP NAME ADDITIONAL MATERIAL SYMBOLS WELL-GRADED GRAVEL, SYMBOLS TYPICAL DESCRIPTION GRAVEL CLEAN O GW FINE TO COARSE GRAVEL AND GRAVEL CC CEMENT CONCRETE GRAVELLY c5%FWEs "` GP POORLY GRADED GRAVEL SOILS MORE TMAN 50% AC ASPHALT CONCRETE COARSE OF COARSE GRAVEL GM SILTY GRAVEL GRAINED FRACTION ED WITH FINES CR CRUSHED ROCK 1 SOILS ON NO.4 SIEVE >12%FHES QUARRY SPALLS GC CLAYEY GRAVEL WELL-GRADED SAND, TS TOPSOIUSODIDUFF MORE THAN 50% SAND CLEAN SW FINE TO COARSE SAND RETAINED ON AND SAND No.200 SEVE SANDY .5%FINES SP POORLY GRADED SAND GROUNDWATER SOILS MORE THAN 50% EXPLORATION SYMBOLS OF COARSE SAND SM SILTY SAND FRACTION WITH FINES MEASURED GROUNDWATER LEVEL IN EXPLORATION, NO,A SEVE ,� ONESELL,OR PiEZOMETER ScSC CLAYEY SAND GROUNDWATER OBSERVED AT TIME OF EXPLORATION SILTS MIL SILT PERCHED WATER OBSERVED AT TIME OF EXPLORATION AND INORGANIC �_ MEASURED FREE PRODUCT IN WELL OR PIEZOMETER FINE CLAYS CL CLAY GRAINED SOILS I'O D""T ORGANIC SILT, STRATIGRAPHIC CONTACT LESST.M50 rORGANIC OIL ORGANIC CLAY — APPROXIMATE CONTACT BETWEEN SOIL STRATA SILT OF HIGH PLASTICITY, OR GEOLOGIC UNIT MOR E THAN 50% Sip MH ELASTIC SILT --- APPROXIMATE LOCATION OF SOIL STRATA CHANGE PASSING NO. INORGANIC WITHIN GEOLOGIC SOIL UNIT 200 SIM CLAYS CH CLAY OF HIGH PLASTICITY, FAT CLAY APPROXIMATE GRADUAL CHANGE BETWEEN SOIL uOuauw ORGANIC CLAY. STRATA OR GEOLOGIC SOIL UNIT BOOR MORE ORGANIC OH ORGANIC SILT APPROXIMATE GRADUAL CHANGE OF SOIL STRATA WITHIN GEOLOGIC SOIL UNIT HIGHLY ORGANIC SOILS PT PEAT LABORATORY/FIELD TEST CLASSIFICATIONS 70 %F PERECENT FINES MD MOISTURE CONTENT AND DRY DENSITY AL ATTERBERG LIMITS 60 r CA CHEMICAL ANALYSIS OC ORGANIC COMPOUND T PM PERMEABILITY OR - -- CP LABORATORY HYDRAULIC CONDUCTIVITY i A-LINE COMPACTION TEST '0 PP POCKET PENETROMETER W I j j CS CONSOLIDATION TEST 1 CH IDS DIRECT SHEAR SA SIEVE ANALYSIS _ TX TRIAXIAL COMPRESSION 40 - - -+ - - HA HYDROMETER ANALYSIS _...,.. _. __ IfI lttt'" MC MOISTURE CONTENT UC UNCONFINED COMPRESSION V ----• __ _._ ._ _ .__. I - VS VANE SHEAR y 30f - a M 3�H , SAMPLER SYMBOLS 20 CL I -—i 2.4 INCH I.D.SPLIT BARREL ® SHELBY TUBE 10 DIRECT-PUSH ® PISTON 10 - —' - - STANDARD PENETRATION TEST ® BULK OR GRAB ML&OL SHEEN CLASSIFICATIONS 0 10 20 30 40 50 60 70 80 90 100 LIQUID LIMIT NS NO VISIBLE SHEEN SS SLIGHT SHEEN SOIL MOISTURE MODIFIERS: MS MODERATE SHEEN DRY-ABSENCE OF MOISTURE,DUSTY,DRY TO THE TOUCH MOIST-DAMP,BUT NO VISIBLE WATER HS HEAVY SHEEN WET-VISIBLE FREE WATER OR SATURATED,USUALLY SOIL IS OBTAINED BELOW WATER TABLE NT NOT TESTED INSIGHT GEOLOGIC. INC_ �_-� Key to Exploration Logs B-1 _ `�w REMARKS AND o w ill ill I . LITNOLOGY SOIL DESCRIPTION LABORATORY TEST RESULTS 0 SP-SM . Brown fine to coarse sand with fine gravel and silt,occasional 1 18l7 31 wood,dense,moist 2 18/12 33 3 18/16 68 Brown fine to coarse sand with fine gravel,trace silt,dense to 10 4 2/2 50/5 very dense,moist 5 16/14 47 Grades to dense 6 8/3 50/2 (- Grades to very dense 7 18/12 44 U) Grades to dense 20 8 18113 51 Grades to very dense 9 18l13 39 Grades to dense 10 18/14 22 Grades to medium to coarse sand with fine gravel,very dense 11 18/18 W6 30 12 18114 31 Brown fine to medium sand with silt,dense,moist 13 18/15 35 2 14 18/16 32 a Grades to wet rn }15 18/18 36 40 16 18/18 30 17 18/18 34 Brown silty fine sand,dense,wet 18 18/18 20 Grades to medium dense 19 18/18 40 2 Grades to dense J0 20 18/18 41 rn 21 18118 48 Grades to silty fine to medium sand 22 18/18 34 Grades to silty fine sand 23 18/18 41 60 24 18/18 35 Brown sandy silt,hard,wet 25 18/18 25 Grades to very stiff 26 18/18 29 J� Grades to gray-brown 27 18/18 35 Grades to hard 70 28 18/18 29 Grades to very stiff Groundwater encountered at 35 feet 80 LEGEND: PROJECT NO.:929-001-01 DATE:APRIL 27,2017 TOTAL DEPTH:71.5 FEET DRILLING CONTRACTOR:BORETEC DRILLING EQUIPMENT:TRACK-MOUNTED DRILL RIG DRILLING METHOD:HOLLOW STEM AUGER LOGGED BY:KEVIN VANDEHEY ALLISON PROPERTY MASON COUNTY,WASHINGTON INSIGHT GEOLOGIC, INC Exploration Log B-1 B-2 REMARKS W �' y AN LITHOLCKsv SOIL DESCRIPTION LABURATORV Y y j TEST RESULTS 0 Brown fine to coarse sand with fine to coarse gravel and sift, r ` medium dense,moist 1 18/16 28 10 2 18/13 30 (L Brown fine to coarse sand with fine gravel,dense,moist CO 3 18118 62 (° tt Brown fine to coarse sand with fine gravel and sift,very dense, cn as.a moist 20 4 1216 50/6 { k. y- 5 18/16 67 n- Brown fine to coarse sand with fine to coarse gravel,very dense, mast 30 6 18/16 29 A Brown fine to coarse sand with silt,medium dense,wet 7 18/18 35 Grades to fine to medium sand with silt,dense a 40 6 18/16 28 to Grades to medium dense 9 19/16 at Grades to dense 50 10 18/18 41 Brown silty fine sand,hard,wet 11 18/18 42 U) 60 12 18/18 31 Brown sandy silt,hard,wet 13 18118 50 —� 70 14 lane 33 1 Grades to silt,dense Groundwater encountered at 30 feet 80 LEGEND: PROJECT NO.:929-001-01 DATE:APRIL 27,2017 TOTAL DEPTH:71.5 FEET DRILLING CONTRACTOR:BORETEC DRILLING EQUIPMENT:TRACK-MOUNTED DRILL RIG DRILLING METHOD:HOLLOW STEM AUGER LOGGED BY:KEVIN VANDEHEY ALLISON PROPERTY MASON COUNTY,WASHINGTON INSIGHT GEOLOGIC. INC. �ti , Exploration Log B-2 ATTACHMENT B LABORATORY ANALYSES RESULTS Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 12.5'-14.0' Date Tested: 5/1/17 Depth: 12.5- 14 Feet Tested By: Kevin Vandehey Moisture Content(%) 6.4% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 2.1 1.5 in. (37.5) 100.0 Fine Gravel 25.3 3/4 in. (19.0) 97.9 3/8 in. (9.5-mm) 84.8 Coarse Sand 12.8 No. 4 (4.75-mm) 72.5 Medium Sand 33.9 No. 10 (2.00-mm) 59.7 Fine Sand 22.0 No. 20 (.850-mm) 44.3 No. 40 (.425-mm) 25.8 Fines 3.8 No. 60(.250-mm) 13.5 Total 100.0 No. 100 (.150-mm) 7.5 No. 200 (.075-mm) 3.8 LL -- PL -- PI -- D10 1.90 D30 0.50 D60 2.00 D90 13.00 Cc 0.07 Cu 1.05 ASTM Classification Group Name: Poorly-Graded Sand with Gravel Symbol: SP INSIGHT GEOLOGIC. INC. Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 20.0'-21.5' Date Tested: 5/1/17 Depth: 20-21.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 5.3% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 9.8 1.5 in. (37.5) 100.0 Fine Gravel 22.2 314 in. (19.0) 90.2 3/8 in. (9.5-mm) 79.5 Coarse Sand 16.1 No.4(4.75-mm) 68.0 Medium Sand 26.5 No. 10 (2.00-mm) 51.9 Fine Sand 20.8 No. 20 (.850-mm) 38.4 No. 40 (.425-mm) 25.4 Fines 4.6 No. 60 (.250-mm) 15.4 Total 100.0 No. 100 (.150-mm) 8.8 No.200 (.075-mm) 4.6 LL -- PL -- PI -- D10 0.18 D30 0.55 D60 3.10 D90 19.00 Cc 0.5 Cu 17.2 ASTM Classification Group Name: Poorly-Graded Sand with Gravel Symbol: SP INSIGHT GEOLOGIC, INC. %_ ,,` .1�� .,� . Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 30.0'-31.5' Date Tested: 5/1/17 Depth: 30-31.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 9.2% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 4.0 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 97.9 Coarse Sand 2.7 No. 4(4.75-mm) 96.0 Medium Sand 9.5 No. 10 (2.00-mm) 93.3 Fine Sand 74.4 No. 20 (.850-mm) 89.3 No.40 (.425-mm) 83.8 Fines 9.3 No. 60(.250-mm) 67.4 Total 100.0 No. 100(.150-mm) 33.6 No. 200(.075-mm) 9.3 LL -- PL -- PI -- D,a 0.076 D30 0.150 D60 0.230 D90 1.000 Cc 1.29 Cu 3.03 ASTM Classification Group Name: Poorly-Graded Sand with Silt Symbol: SP-SM INSIGHT \GEOLOGIC, INC. Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 40.0'-41.5' Date Tested: 5/1/17 Depth: 40-41.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 26.8% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 0.2 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 100.0 Coarse Sand 0.4 No. 4 (4.75-mm) 99.8 Medium Sand 1.4 No. 10 (2.00-mm) 99.3 Fine Sand 82.0 No. 20 (.850-mm) 98.7 No. 40 (.425-mm) 98.0 Fines 16.0 No. 60 (.250-mm) 95.4 Total 100.0 No. 100 (.150-mm) 69.4 No. 200 (.075-mm) 16.0 LL -- PL -- PI -- D10 0.00 D30 0.09 D60 0.14 D90 0.22 Cc -- Cu -- ASTM Classification Group Name: Silty Sand Symbol: SM INSIGHT GEOLOGIC, INC. .R , Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 50.0'-51.5' Date Tested: 5/1/17 Depth: 50-51.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 27.2% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 0.0 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 100.0 Coarse Sand 0.1 No.4 (4.75-mm) 100.0 Medium Sand 0.3 No. 10(2.00-mm) 99.9 Fine Sand 63.5 No. 20(.850-mm) 99.7 No. 40 (.425-mm) 99.6 Fines 36.1 No. 60 (.250-mm) 99.3 Total 100.0 No. 100 (.150-mm) 90.7 No. 200(.075-mm) 36.1 LL -- PL -- PI -- D10 0.00 D30 0.00 D60 0.10 D90 0.16 Cc -- Cu -- ASTM Classification Group Name: Silty Sand Symbol: SM INSIGHT GEOLOGIC, INC. Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 60.0'-61.5' Date Tested: 5/1/17 Depth: 60-61.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 24.4% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 0.1 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 100.0 Coarse Sand 0.5 No. 4 (4.75-mm) 99.9 Medium Sand 2.0 No. 10 (2.00-mm) 99.4 Fine Sand 47.0 No. 20 (.850-mm) 99.1 No. 40 (.425-mm) 97.4 Fines 50.4 No. 60 (.250-mm) 92.9 Total 100.0 No. 100 (.150-mm) 86.2 No. 200 (.075-mm) 50.4 LL - PL - PI - 010 0.00 D30 0.00 D60 0.09 D90 0.20 Cc -- Cu -- ASTM Classification Group Name: Sandy Silt Symbol: ML INSIGHT GEOLOGIC. INC. Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-1 Job Number: 929-001-01 Sample Name: B-1 70.0'-71.5' Date Tested: 5/1/17 Depth: 70-71.5 Feet Tested By: Kevin Vandehey Moisture Content (%) 27.8% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 0.0 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 100.0 Coarse Sand 0.0 No. 4 (4.75-mm) 100.0 Medium Sand 0.1 No. 10 (2.00-mm) 100.0 Fine Sand 30.9 No. 20 (.850-mm) 100.0 No. 40 (.425-mm) 99.9 Fines 69.0 No. 60 (.250-mm) 99.8 Total 100.0 No. 100 (.150-mm) 99.2 No. 200 (.075-mm) 69.0 LL -- PL -- PI -- D10 0.00 DJ0 0.00 D60 0.00 D90 0.14 Cc -- Cu -- ASTM Classification Group Name: Sandy Silt Symbol: ML INSIGHT GEOLOGIC. INC. w v Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-2 Job Number: 929-001-01 Sample Name: B-2 30.0'-31.5' Date Tested: 5/1/17 Depth: 30-31.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 18.0% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 6.1 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 96.9 Coarse Sand 3.6 No. 4 (4.75-mm) 93.9 Medium Sand 7.9 No. 10(2.00-mm) 90.3 Fine Sand 73.8 No. 20(.850-mm) 87.1 No. 40(.425-mm) 82.4 Fines 8.5 No. 60 (.250-mm) 64.9 Total 100.0 No. 100(.150-mm) 30.4 No. 200(.075-mm) 8.5 LL -- PL -- PI -- D,o 0.08 D30 0.16 D60 0.24 Dyo 2.00 Cc 1.3 Cu 3.0 ASTM Classification Group Name: Poorly-Graded Sand with Silt Symbol: SP-SM INSIGHT GEOLOGIC, INC. Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-2 Job Number: 929-001-01 Sample Name: B-2 50.0'-51.5' Date Tested: 5/1/17 Depth: 50-51.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 33.7% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 0.8 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 100.0 Coarse Sand 0.6 No.4 (4.75-mm) 99.2 Medium Sand 0.9 No. 10(2.00-mm) 98.6 Fine Sand 76.8 No. 20(.850-mm) 98.1 No.40(.425-mm) 97.6 Fines 20.8 No. 60 (.250-mm) 96.7 Total 100.0 No. 100 (.150-mm) 85.0 No. 200 (.075-mm) 20.8 LL -- PL -- PI -- D10 0.000 D30 0.082 D60 0.120 D90 0.170 Cc -- Cu -- ASTM Classification Group Name: Silty Sand Symbol: SM INSIGHT GEOLOGIC, INC. 4 w.. Gradation Analysis Summary Data Job Name: Allison Property Sample Location: B-2 Job Number: 929-001-01 Sample Name: B-2 70.0'-71.5' Date Tested: 5/1/17 Depth: 70-71.5 Feet Tested By: Kevin Vandehey Moisture Content(%) 28.1% Percent Percent by Sieve Size Passing Size Fraction Weight 3.0 in. (75.0) 100.0 Coarse Gravel 0.0 1.5 in. (37.5) 100.0 Fine Gravel 1.3 3/4 in. (19.0) 100.0 3/8 in. (9.5-mm) 98.7 Coarse Sand 0.1 No.4 (4.75-mm) 98.7 Medium Sand 0.4 No. 10 (2.00-mm) 98.6 Fine Sand 10.3 No. 20 (.850-mm) 98.4 No.40 (.425-mm) 98.2 Fines 87.9 No. 60 (.250-mm) 97.8 Total 100.0 No. 100(.150-mm) 97.2 No. 200(.075-mm) 87.9 LL -- PL -- PI -- DI, 0.000 D30 0.000 D69 0.000 D99 0.089 Cc -- Cu -- ASTM Classification Group Name: Silt Symbol: ML INSIGHT GEOLOGIC, INC. U.S.Standard Sieve Size 3" 1.5" 314" 318" #4 #10 #20 #40 #60 #100 0200 100 90 80 - r 70 lit 60 x 50 d c 40 Y Y a 30 20 1 1071_t I � -- 0 1000 100 10 1 0.1 0.01 0.001 Grain Size in Millimeters -B-1 12.5'-14.0' -•B-1 20.0'-21.5' k--B-1 30.0'-31.5' 1 * B-1 40.0'-41.5' —+—B-1 50.0'-51.5' —A-- B-1 60.0'•61.5' COBBLES ORAVEL SAND SILT OR CLAY COARSE FME COARSE I MEDIUM FINE ALLISON PROPERTY MASON COUNTY.WASHINGTON Graph 1 INSIGHT GEOLOGIC, INC. Gradation Analysis Results U.S.Standard Sieve Size 3" 1.5" 3/4" 3/8" 94 #10 020 #40 #60 #100 0200 100 - - - -- 80 - - - O1 70 k 60 so e o. 40 IL 30 20 1 10 - I 0 1000 100 10 1 0.1 0.01 0.001 Grain Size In Millimeters -s B-1 70.0'-71.5' a-•B-2 30.0'-31.5' -i-B-2 50.0'51.5' - -S-2 70.0'-71.5' GRAVEL SAND COBBLES SILT OR CLAY COARSE DINE COARSE I MEDIUM FINE ALLISON PROPERTY MASON COUNTY,WASHINGTON Graph 2 lNsicliT ceoLocic. INC. Gradation Analysis Results ATTACHMENT C MODELING RESULTS t, Page 1 of 8 Slide Analysis Information SLIDE - An Interactive Slope Stability Program Project Summary File Name:Allison Property.slim Slide Modeler Version:6.038 Project Title:SLIDE-An Interactive Slope Stability Program Date Created:5/15/2017,10:17:26 AM General Settings Units of Measurement:Imperial Units Time Units:days Permeability Units:feet/day Failure Direction:Left to Right Data Output:Standard Maximum Material Properties:20 Maximum Support Properties:20 Analysis Options Analysis Methods Used Bishop simplified Janbu simplified Number of slices:25 Tolerance:O.00S Maximum number of iterations:50 Check malpha<0.2:Yes Initial trial value of FS:1 Steffensen Iteration:Yes Groundwater Analysis Groundwater Method:Water Surfaces Pore Fluid Unit Weight:62.4 Ibs/ft3 Advanced Groundwater Method:None Random Numbers Pseudo-random Seed:10116 Random Number Generation Method:Park and Miller v.3 Surface Options Allison Property.slim 5/15/2017,10:17:26 AM sumwrtxro[r c.o�e •:•- Page 2 of 8 Surface Type:Circular Search Method:Slope Search Number of Surfaces:5000 Upper Angle:Not Defined Lower Angle:Not Defined Composite Surfaces:Disabled Reverse Curvature:Create Tension Crack Minimum Elevation:Not Defined Minimum Depth:Not Defined Material Properties Property Material Material Material Color Strength Type Mohr-Coulomb Mohr-Coulomb Mohr-Coulomb Unsaturated Unit Weight[Ibs/ft3] 115 110 Saturated Unit Weight[Ibs/ft3] 140 140 Cohesion[psf] 100 400 0 Friction Angle[deg] 35 25 20 Water Surface Water Table Water Table Water Table Hu Value 1 1 1 Global Minimums Method:bishop simplified FS:0.280355 Center:150.416,781.820 Radius:15.853 Left Slip Surface Endpoint:141.556,768.675 Right Slip Surface Endpoint:144.077,767.290 Resisting Moment=37.4129 lb-ft Driving Moment=133.448 lb-ft Total Slice Area=0.125222 ft2 Method:janbu simplified FS:0.279693 Center:150.416,781.820 Radius:15.853 Left Slip Surface Endpoint:141.556,768.675 Right Slip Surface Endpoint:144.077,767.290 Resisting Horizontal Force=2.07074 lb Driving Horizontal Force=7.40363 lb Total Slice Area=0.125222 ft2 Valid/Invalid Surfaces Method:bishop simplified Allison Property.slim 5/15/2017, 10:17:26 AM SllbpflfElMET fAL ®�•- Page 3 of 8 Number of Valid Surfaces:4291 Number of Invalid Surfaces:709 Error Codes: Error Code-103 reported for 70 surfaces Error Code-105 reported for 329 surfaces Error Code-106 reported for 71 surfaces Error Code-109 reported for 6 surfaces Error Code-112 reported for 3 surfaces Error Code-113 reported for 230 surfaces Method:janbu simplified Number of Valid Surfaces:4234 Number of Invalid Surfaces:766 Error Codes: Error Code-103 reported for 70 surfaces Error Code-105 reported for 329 surfaces Error Code-106 reported for 71 surfaces Error Code-108 reported for S7 surfaces Error Code-109 reported for 6 surfaces Error Code-112 reported for 3 surfaces Error Code-113 reported for 230 surfaces Error Codes The following errors were encountered during the computation: -103=Two surface/slope intersections,but one or more surface/nonslope external polygon intersections lie between them.This usually occurs when the slip surface extends past the bottom of the soil region,but may also occur on a benched slope model with two sets of Slope Limits. -105=More than two surface/slope intersections with no valid slip surface. -106=Average slice width is less than 0.0001`(maximum horizontal extent of soil region).This limitation is imposed to avoid numerical errors which may result from too many slices,or too small a slip region. -108=Total driving moment or total driving force<0.1.This is to limit the calculation of extremely high safety factors if the driving force is very small(0.1 is an arbitrary number). -109=Soiltype for slice base not located.This error should occur very rarely,if at all.It may occur if a very low number of slices is combined with certain soil geometries,such that the midpoint of a slice base is actually outside the soil region,even though the slip surface is wholly within the soil region. -112=The coefficient M-Alpha=cos(alpha)(l+tan(alpha)tan(phi)/F)<0.2 for the final iteration of the safety factor calculation.This screens out some slip surfaces which may not be valid in the context of the analysis,in particular,deep seated slip surfaces with many high negative base angle slices in the passive zone. -113=Surface intersects outside slope limits. Slice Data Global Minimum Query(bishop simplified)-Safety Factor:0.280355 Base Base Shear Shear Base Pore Effective Slice Width Weight Base Cohesion Friction Stress Strength Normal Pressure Normal Number IN [lbs] Material [psfl Angle [Psfl (psf] Stress (psf] Stress [degrees] [psf] [psf] Allison Property.slim 5/15/2017, 10:17:26 AM srarwrt�r arm 1� Page 4 of 8 1 0.100851 0.0849101 Material 3 0 20 0.32459 0.0910004 0.625131 0.375109 0.250022 2 0.100851 0.246926 Material 0 20 0.950991 0.266615 1.82366 1.09114 0.732523 3 0.100851 0.393412 Materia3l 0 20 1.52666 0.428008 2.91449 1.73855 1.17594 4 0.100851 0.524598 Material 0 20 2.05114 0.575047 3.89825 2.31833 1.57992 5 0.100851 0.640705 Material 0 20 2.52394 0.7076 4.77558 2.83146 1.94412 6 0.100851 0.741945 Materia3l 0 20 2.9446 0.825534 5.54704 3.2789 2.26814 7 0.100851 0.828524 Material 0 20 3.31264 0.928715 6.21317 3.66154 2.55163 8 0.100851 0.900641 Material 3 0 20 3.62758 1.01701 6.77447 3.98026 2.79421 9 0.100851 0.958488 Material 0 20 3.88889 1.09027 7.23143 4.23592 2.99551 10 0.100851 1.00225 Material 0 20 4.09616 1.14838 7.58446 4.42932 3.15514 11 0.100851 1.03211 Material 0 20 4.24879 1,19117 7.834 4.56127 3.27273 12 0.100851 1.04823 Materia3l 0 20 4.34635 1.21852 7.98039 4.63253 3.34786 13 0.100851 1.05079 Material 0 20 4.38829 1,23028 8.02399 4.64383 3.38016 14 0.100851 1.03994 Material 0 20 4,37406 1.22629 7.96511 4.5959 3.36921 15 0.100851 1.01585 Material 0 20 4.30315 1.20641 7.80402 4.48942 3.3146 16 0.100851 0,978662 Material 3 0 20 4.17503 1.17049 7.54098 4.32507 3.21591 17 0.100851 0.928526 Material 3 0 20 3.98916 1.11838 7.17621 4.10349 3.07272 18 0.100851 0.865584 Material 0 20 3.74489 1.0499 6.7099 3,82532 2.88458 19 0.100851 0.789974 Material 3 0 20 3,44175 0.964911 6.14223 3.49115 2.65108 20 0.100851 0.701827 Material3 0 20 3.07909 0.863237 5.47331 3.10159 2.37172 21 0.100851 0.601275 Material 0 20 2.65632 0.744713 4.70327 2.65719 2.04608 22 0.100851 0.48844 Material3 0 20 2.17284 0.609167 3.83218 2.15851 1.67367 23 0,100851 0.363446 Material3 0 20 1.62803 0.456425 2.86011 1.60609 1.25402 24 0.100851 0.226408 Material3 0 20 1,02123 0.286306 1.78707 1.00045 0.786622 25 0.100851 0.0774411 Material3 0 20 0.351801 0.0986293 0.613063 0.342082 0.270981 Allison Property.slim 5/15/2017, 10:17:26 AM 4JOEWIHPMF140H �1 Page 5 of 8 Global Minimum Query Uanbu simplified)-Safety Factor:0.279693 Base Base Effective Base Shear Shear Pore Slice Width Weight Base Friction Normal Normal Number Cohesion Stress Strength Pressure [ft] [ibs] Material [psf] Angle [psf] [per Stress [psf] Stress [degrees] [psf] [psf] 1 0.100851 0.0849101 Material 0 20 0.325708 0.0910983 0.6254 0.375109 0,250291 2 0.100851 0.246926 Material 3 0 20 0.954261 0.2669 1.82444 1.09114 0.733302 3 0.100851 0.393412 Material 0 20 1.53189 0.42846 2.91573 1.73855 1.17718 4 0.100851 0.524598 Material 3 0 20 2.05815 0.575649 3.89991 2.31833 1.S8158 5 0.100851 0.640705 Material 0 20 2.53254 0.708334 4.7776 2.83146 1.94614 6 0.100851 0.741945 Material 0 20 2.95461 0.826383 5.54937 3.2789 2.27047 7 0.100851 0.828524 Material3 0 20 3.32386 0.929661 6.21576 3.66154 2.55422 8 0.100851 0.900641 Material3 0 20 3.63981 1.01803 6.77729 3.98026 2.79703 9 0.100851 0.958488 Material 3 0 20 3.90199 1.09136 7.23441 4.23592 2.99849 10 0.100851 1.00225 Material 0 20 4.1099 1.14951 7.58758 4.42932 3.15826 11 0.100851 1.03211 Material 0 20 4.26303 1.19234 7.8372 4.56127 3.27593 12 0.100851 1.04823 Material3 0 20 4.36085 1.2197 7.98364 4.63253 3.35111 13 0.100851 1.05079 Material 0 20 4.4029 1.23146 8.02724 4.64383 3.38341 14 0.100851 1.03994 Material 0 20 4.3886 1.22746 7.96831 4.5959 3.37241 15 0.100851 1.01585 Material 0 20 4.31741 1.20755 7.80714 4.48942 3.31772 16 0.100851 0.978662 Material3 0 20 4.18884 1.17159 7.54398 4.32507 3.21891 17 0.100851 0.928S26 Material3 0 20 4.00228 1.11941 7.17904 4.10349 3.07555 18 0.100851 0.865584 Material3 0 20 3.75719 1.05086 6.71254 3.82532 2.88722 19 0.100851 0.789974 Material3 0 20 3.45301 0.965782 6.14462 3.49115 2.65347 20 0.100851 0.701827 Material3 0 20 3.08913 0.864007 5.47543 3.10159 2.37384 21 0.100851 0.601275 Material3 0 20 2.66496 0.74537 4.70508 2.65719 2.04789 22 0.100851 0.48844 Material3 0 20 2.17989 0.609699 3.83364 2.15851 1.67513 Material Allison Property.slim 5/15/2017, 10:17:26 AM suocwrt*wer s.on &C- Page 6 of 8 3 24 0.100851 0.226408 Material3 0 20 1.02452 0.28655 1.78774 1.00045 0.787292 25 0.100851 0.0774411 Material3 0 20 0.352931 0.0987124 0.613292 0.342082 0.27121 Interstice Data Global Minimum Query(bishop simplified)-Safety Factor:0.280355 X Y Interslice Interslice Interslice Slice coordinate coordinate-Bottom Normal Force Shear Force Force Angle Number ]ft] [ft] [Ibs] [Ibs] [degrees] 1 141.556 768.675 0 0 0 2 141.657 768.608 0.00943526 0 0 3 141.757 768.541 0.0345281 0 0 4 141.858 768.476 0.0707597 0 0 5 141.959 768.412 0.114105 0 0 6 142.06 768.349 0.161014 0 0 7 142.161 768.287 0.208398 0 0 8 142.262 768.226 0.2S3611 0 0 9 142.363 768.166 0.294438 0 0 10 142.463 768.107 0.329081 0 0 11 142.564 768.049 0.356145 0 0 12 142.665 767.992 0.374631 0 0 13 142.766 767.936 0.38392 0 0 14 142.867 767.881 0.383764 0 0 15 142.968 767.827 0.374281 0 0 16 143.068 767.773 0,355941 0 0 17 143.169 767.721 0.329559 0 0 18 143.27 767.67 0.296291 0 0 19 143.371 767.619 0.257624 0 0 20 143.472 767.S7 0.215368 0 0 21 143.573 767.521 0.171655 0 0 22 143.674 767.473 0.128928 0 0 23 143.774 767.426 0.0899427 0 0 24 143.875 767.38 0,0577554 0 0 2S 143.976 767.335 0.0357242 0 0 26 144.077 767.29 0 0 0 Global Minimum Query Oanbu simplified)-Safety Factor:0.279693 X y Interslice Interslice Interslice Slice coordinate coordinate-Bottom Normal Force Shear Force Force Angle Number [ft] [ft] [Ibs] fibs] [degrees] 1 141.556 768.675 0 0 0 2 141.657 768.608 0.00949398 0 0 3 141.757 768.541 0.0347584 0 0 4 141.858 768.476 0.0712649 0 0 Allison Property.slim 5/15/2017, 10:17:26 AM SIICfIME�R6Db i� •- Page 7 of 8 5 141.959 768.412 0.114979 0 0 6 142.06 768.349 0.16234 0 0 7 142.161 768.287 0.210251 0 0 8 142.262 768.226 0.256056 0 0 9 142.363 768.166 0.29753 0 0 10 142.463 768.107 0.332866 0 0 11 142.564 768.049 0.360659 0 0 12 142.665 767.992 0.3799 0 0 13 142.766 767.936 0.38996 0 0 14 142.867 767.881 0.390583 0 0 15 142.968 767.827 0.381875 0 0 16 143.068 767.773 0.364297 0 0 17 143.169 767.721 0.338655 0 0 18 143.27 767.67 0.306093 0 0 19 143.371 767.619 0.268088 0 0 20 143.472 767.57 0.226442 0 0 21 143.573 767.521 0.183273 0 0 22 143.674 767.473 0.141017 0 0 23 143.774 767.426 0.102416 0 0 24 143.875 767.38 0.0705174 0 0 25 143.976 767.335 0.0486671 0 0 26 144.077 767.29 0 0 0 List Of Coordinates Water Table X Y 0 779.881 121.151 779.881 193.641 740.07 External Boundary X Y 0 729.688 207.888 729.688 193.641 740.07 102.938 789.884 100 800 0 800 0 740.07 Material Boundary X Y 0 740.07 Allison Property.slim 5/15/2017,10:17:26 AM SIfOflN1EFP4ET 6dJt Page 8 of 8 176.129 740.07 Material Boundary X Y 102.938 789.884 106.038 779.332 176.129 740.07 193.641 740.07 Allison Property.slim 5/15/2017, 10:17:26 AM .uvN IYv LTOZ :aw ,AeW KO 3nEn3U 130 suoq/puo7 anliey :uogQunsab s6lleu O N I `31190103 9 1 H 91 S N I AZiadoad uosIIIVOR wrap LI 0% SZl OM St 09 9z 0 SZ 09. i 1 ..a_. I I.....�...a_li_iiJ.......uJ_._a_..�..1.........a...J_....�y......1_a_..ia_L.._.. I I_.._.i.�.i�_�.L�.. l�. V N V N ( M *0'9 E 0'S (D 0'6 ® C ® ) S £ ED 0 ®® ` (D (D (D �% 0'Z -- (YD S.t qD G o't j 0'0 (D zoZoe,3 C1a3es Page 1 of 8 Slide Analysis Information SLIDE - An Interactive Slope Stability Program Project Summary File Name:Allison Property.slim Slide Modeler Version:6.038 Project Title:SLIDE-An Interactive Slope Stability Program Date Created:5/15/2017,10:17:26 AM General Settings Units of Measurement:Imperial Units Time Units:days Permeability Units:feet/day Failure Direction:Left to Right Data Output:Standard Maximum Material Properties:20 Maximum Support Properties:20 Analysis Options Analysis Methods Used Bishop simplified Janbu simplified Number of slices:25 Tolerance:0.005 Maximum number of iterations:50 Check malpha<0.2:Yes Initial trial value of FS:1 Steffensen Iteration:Yes Groundwater Analysis Groundwater Method:Water Surfaces Pore Fluid Unit Weight:62.4 Ibs/ft3 Advanced Groundwater Method:None Random Numbers Pseudo-random Seed:10116 Random Number Generation Method:Park and Miller v.3 Surface Options Allison Property.slim 5/15/2017,10:17:26 AM sucei��r ana •�•- Page 2 of 8 Surface Type:Circular Search Method:Slope Search Number of Surfaces:5000 Upper Angle:Not Defined Lower Angle:Not Defined Composite Surfaces:Disabled Reverse Curvature:Create Tension Crack Minimum Elevation:Not Defined Minimum Depth:Not Defined Material Properties Property Material Material Material Color Strength Type Mohr-Coulomb Mohr-Coulomb Mohr-Coulomb Unsaturated Unit Weight[Ibs/ft3] 115 110 Saturated Unit Weight[Ibs/ft3] 140 140 Cohesion[psf] 100 400 0 Friction Angle[deg] 35 25 30 Water Surface Water Table Water Table Water Table Hu Value 1 1 1 Global Minimums Method:bishop simplified FS:1.055830 Center:150.416,781.820 Radius:15.853 Left Slip Surface Endpoint:141.556,768.675 Right Slip Surface Endpoint:144.077,767.290 Resisting Moment=110.708 lb-ft Driving Moment=104.854 lb-ft Total Slice Area=0.125222 ft2 Method:janbu simplified FS:1.053520 Center:150.416,781.820 Radius: 15.853 Left Slip Surface Endpoint: 141.556,768.675 Right Slip Surface Endpoint:144.077,767.290 Resisting Horizontal force=6.11604 lb Driving Horizontal Force=5.80535lb Total Slice Area=0.125222 ft2 Valid/invalid Surfaces Method:bishop simplified Allison Property.slim 5/1512017, 10:17:26 AM sslo[lxre�wet tos toll,6i j Page 3 of 8 Number of Valid Surfaces:4291 Number of Invalid Surfaces:709 Error Codes: Error Code-103 reported for 70 surfaces Error Code-105 reported for 329 surfaces Error Code-106 reported for 71 surfaces Error Code-109 reported for 6 surfaces Error Code-112 reported for 3 surfaces Error Code-113 reported for 230 surfaces Method:janbu simplified Number of Valid Surfaces:4234 Number of Invalid Surfaces:766 Error Codes: Error Code-103 reported for 70 surfaces Error Code-105 reported for 329 surfaces Error Code-106 reported for 71 surfaces Error Code-108 reported for 57 surfaces Error Code-109 reported for 6 surfaces Error Code-112 reported for 3 surfaces Error Code-113 reported for 230 surfaces Error Codes The following errors were encountered during the computation: -103=Two surface/slope intersections,but one or more surface/nonslope external polygon intersections lie between them.This usually occurs when the slip surface extends past the bottom of the soil region,but may also occur on a benched slope model with two sets of Slope Limits. -105=More than two surface/slope intersections with no valid slip surface. -106=Average slice width is less than 0.0001`(maximum horizontal extent of soil region).This limitation is imposed to avoid numerical errors which may result from too many slices,or too small a slip region. -108=Total driving moment or total driving force<0.1.This is to limit the calculation of extremely high safety factors if the driving force is very small(0.1 is an arbitrary number). -109=Soiltype for slice base not located.This error should occur very rarely,if at all.It may occur if a very low number of slices is combined with certain soil geometries,such that the midpoint of a slice base is actually outside the soil region,even though the slip surface is wholly within the soil region. -112=The coefficient M-Alpha=cos(alpha)(l+tan(alpha)tan(phi)/F)<0.2 for the final iteration of the safety factor calculation.This screens out some slip surfaces which may not be valid in the context of the analysis,in particular,deep seated slip surfaces with many high negative base angle slices in the passive zone. -113=Surface intersects outside slope limits. Slice Data Global Minimum Query(bishop simplified)-Safety Factor:1.05583 Base Base Shear Shear Base Pore Effective Slice Width Weight Base Friction Normal Normal Number [ft] [lbs] Materi Cohesion Stress Strength Pressure al Angle Stress Stress ]Psfl [degrees] ]Psfl [Psfl [Psfl [Psi] [psfl Allison Property.slim 5/15/2017, 10:17:26 AM �:•- Page 4 of 8 1 0.100851 0.0667225 Material 0 30 0.264941 0.279733 0.484512 0 0.484512 2 0.100851 0.194021 Material 0 30 0.773822 0.817024 1.41513 0 1.41513 3 0.100851 0.309117 Material3 0 30 1.23826 1.30739 2.26446 0 2.26446 4 0.100851 0.412192 Material 0 30 1.6583 1.75088 3.03261 0 3.03261 5 0.100851 0.503418 Material3 0 30 2.03398 2.14754 3.71966 0 3.71966 6 0.100851 0.582964 Material3 0 30 2.36537 2.49743 4.32567 0 4.32567 7 0.100851 0.650991 Material 3 0 30 2.65248 2.80057 4.85074 0 4.85074 8 0.100851 0.707654 Material3 0 30 2.89536 3.05701 5.29489 0 5.29489 9 0.100851 0.753105 Material3 0 30 3.09403 3.26677 5.65822 0 5.65822 10 0.100851 0.78749 Material 0 30 3.24852 3.42989 5.94074 0 5.94074 11 0.100851 0.810948 Material3 0 30 3.35885 3.54637 6.1425 0 6.1425 12 0.100851 0.823616 Material3 0 30 3.42503 3.61625 6.26353 0 6.26353 13 0.100851 0.825626 Material 0 30 3.44708 3.63953 6.30385 0 6.30385 14 0.100851 0.817105 Material3 0 30 3.42499 3.61621 6.26346 0 6.26346 15 0.100851 0.798175 Material3 0 30 3.35878 3.5463 6.14237 0 6.14237 16 0.100851 0.768957 Material3 0 30 3.24843 3.42979 5.94056 0 5.94056 17 0.100851 0.729565 Material3 0 30 3.09394 3.26667 5.65804 0 5.65804 18 0.100851 0.68011 Material3 0 30 2.89529 3.05693 5.29475 0 5.29475 19 0.100851 0.620702 Material3 0 30 2.65245 2.80054 4.85067 0 4.85067 20 0.100851 0.551444 Material3 0 30 2.36542 2.49748 4.32576 0 4.32576 21 0.100851 0.472438 Material3 0 30 2.03415 2.14772 3.71996 0 3.71996 22 0.100851 0.383783 Material3 0 30 1.65861 1.75121 3.03319 0 3.03319 23 0.100851 0.285573 Material3 0 30 1.23876 1.30792 2.26538 0 2.26538 24 0.100851 0.1779 Material3 0 30 0.77455 0.817793 1.41646 0 1.41646 25 0.100851 0.0608549 Material3 0 30 0.265926 0.280773 0.486313 0 0.486313 Allison Property.slim 5/15/2017,10:17:26 AM aioEvrnuw�r s.me Page 5 of 8 Global Minimum Query(janbu simplified)-Safety Factor:1.05352 Base Base Shear Shear Base Pore Effective Slice Width Weight Base Friction Normal Normal Number Cohesion Stress Strength Pressure [ft] fibs] Material [psf] Angle [psf] [per Stress [psf] Stress [degrees] [psf] [psf] 1 0.100851 0.0667225 Material 0 30 0.265364 0.279566 0.484222 0 0.484222 2 0.100851 0.194021 Materia3l 0 30 0.77506 0.816541 1.41429 0 1.41429 3 0.100851 0.309117 Material 0 30 1.24025 1.30663 2.26314 0 2.26314 4 0.100851 0.412192 Material 0 30 1.66097 1.74987 3.03087 0 3.03087 5 0.100851 0.503418 Material 0 30 2.03728 2.14632 3.71754 0 3.71754 6 0.100851 0.582964 Material 0 30 2.36922 2.49602 4.32324 0 4.32324 7 0.100851 0.650991 Materia3l 0 30 2.65683 2.79902 4.84804 0 4.84804 8 0.100851 0.707654 Materia3l 0 30 2.90012 3.05533 5.29199 0 5.29199 9 0.100851 0.753105 Material 0 30 3.09913 3.265 5.65515 0 5.65515 10 0.100851 0.78749 Material 0 30 3.2539 3.42805 5.93756 0 5.93756 11 0.100851 0.810948 Material 0 30 3.36444 3.5445 6.13926 0 6.13926 12 0.100851 0.823616 Material 0 30 3.43076 3.61437 6.26027 0 6.26027 13 0.100851 0.825626 Material 3 0 30 3.45285 3.63765 6.3006 0 6.3006 14 0.100851 0.817105 Material 0 30 3.43076 3.61437 6.26028 0 6.26028 15 0.100851 0.798175 Material 0 30 3.36445 3.54452 6.13929 0 6.13929 16 0.100851 0.768957 Material 3 0 30 3.25394 3.42809 5.93763 0 5.93763 17 0.100851 0.729565 Material 0 30 3.09921 3.26508 5.65528 0 5.65528 18 0.100851 0.68011 Material 0 30 2.90024 3.05546 5.29221 0 5.29221 19 0.100851 0.620702 Material3 0 30 2.65701 2.79921 4.84838 0 4.84838 20 0.100851 0.551444 Material3 0 30 2.36949 2.49631 4.32374 0 4.32374 21 0.100851 0.472438 Material3 0 30 2.03767 2.14673 3.71824 0 3.71824 22 0.100851 0.383783 Material 0 30 1.6615 1.75042 3.03181 0 3.03181 Material Allison Property.slim 5/15/2017,10:17:26 AM wonwrfsaEr sun Page 6 of 8 3 24 0.100851 0.1779 Material 3 0 30 0,775906 0.817432 1.41583 0 1.41583 25 0.100851 0.0608549 Material 0 30 0.266394 0.280651 0.486101 0 0.486101 lnterslice Data Global Minimum Query(bishop simplified)-Safety Factor:1.05583 Slice X Y lnterslice lnterslice lnterslice Number coordinate coordinate-Bottom Normal Force Shear Force Force Angle [ft] [ft] [Ibs] [Ibs] [degrees] 1 141.556 768.675 0 0 0 2 141.657 768.608 0.00594804 0 0 3 141.757 768.541 0.0217525 0 0 4 141.858 768.476 0.0445704 0 0 S 141.959 768.412 0.071866S 0 0 6 142.06 768.349 0.101402 0 0 7 142.161 768.287 0.131228 0 0 8 142.262 768.226 0.159671 0 0 9 142.363 768.166 0.185333 0 0 10 142.463 768.107 0.207074 0 0 11 142.564 768.049 0.224012 0 0 12 142.665 767.992 0.235514 0 0 13 142.766 767.936 0.241189 0 0 14 142.867 767.881 0.24088 0 0 15 142.968 767.827 0.234663 0 0 16 143.068 767.773 0.222836 0 0 17 143.169 767.721 0.20592 0 0 18 143.27 767.67 0.184648 0 0 19 143.371 767.619 0.159966 0 0 20 143.472 767.S7 0.133025 0 0 21 143.573 767.521 0.10S178 0 0 22 143.674 767.473 0.0779797 0 0 23 143.774 767.426 0.0531772 0 0 24 143.875 767.38 0.0327116 0 0 25 143.976 767.335 0.0187128 0 0 26 144.077 767.29 0 0 0 Global Minimum Query Ganbu simplified)-Safety Factor:1.05352 X y lnterslice lnterslice lnterslice Slice coordinate coordinate-Bottom Normal Force Shear Force Force Angle Number N [n] [Ibs] [Ibs] [degrees] 1 141.556 768.675 0 0 0 2 141.657 768.608 0.00588473 0 0 3 141.757 768.541 0.0215053 0 0 4 141.858 768.476 0.0440307 0 0 Allison Property.slim 5/15/2017, 10:17:26 AM wocrtmwxel a.n ; Page 7 of 8 5 141.959 768.412 0.070937 0 0 6 142.06 768.349 0.0999974 0 0 7 142.161 768.287 0.129273 0 0 8 142.262 768.226 0.157102 0 0 9 142.363 768.166 0.182096 0 0 10 142.463 768.107 0.203128 0 0 11 142.564 768.049 0.219325 0 0 12 142.665 767.992 0.230063 0 0 13 142.766 767.936 0.234962 0 0 14 142.867 767.881 0.233876 0 0 15 142.968 767.827 0.22689 0 0 16 143.068 767.773 0.214312 0 0 17 143.169 767.721 0.196671 0 0 18 143.27 767.67 0.174712 0 0 19 143.371 767.619 0.149388 0 0 20 143.472 767.57 0.121862 0 0 21 143.573 767.521 0.0934948 0 0 22 143.674 767.473 0.06585 0 0 23 143.774 767.426 0.0406847 0 0 24 143.875 767.38 0.0199488 0 0 25 143.976 767.335 0.00578153 0 0 26 144.077 767.29 0 0 0 List Of Coordinates Water Table X Y 0 759.713 193.641 740.07 External Boundary X Y 0 729.688 207.888 729.688 193.641 740.07 102.938 789.884 100 800 0 800 0 740.07 Material Boundary X Y 0 740.07 176.129 740.07 Allison Property.slim 5/15/2017, 10:17:26 AM l�.•. Page 8 of 8 Material Boundary X Y 102.938 789.884 106.038 779.332 176.129 740.07 193.641 740.07 Allison Property.slim 5/15/2017, 10:17:26 AM Safety Factor n 0.0 a0 0.5 1.0 1.5 2.0 m 2.5 3.0 3.5 4.0 m 4.5 `O 5.0 5.5 6.0+ m n 1 .. w T 0 20 40 80 80 100 120 140 180 180 200 ZZO 240 RIP-? 4+1? Allison Property INSIGHT GEOLOGIC, INC. WsDesaipWw Dewmeredew,ditm —er C—f.V iocurte.aan s.ax Age' May,2017 IF&,Yame ATTACHMENT D REPORT LIMITATIONS AND GUIDELINES FOR USE ATTACHMENT D REPORT LIMITATIONS AND GUIDELINES FOR USE This attachment provides information to help you manage your risks with respect to the use of this report. HYDROGEOLOGIC :SFRVV"'-S ARE PI-RFORIVED FOR SPECIFIC PURPOSES. PERSONS AND PROJECTS This report has been prepared for the exclusive use of David Allison (Client) and his authorized agents. This report may be made available to regulatory agencies for review. This report is not intended for use by others, and the information contained herein is not applicable to other sites. Insight Geologic structures our services to meet the specific needs of our clients. For example, a hydrogeologic or geologic study conducted for a civil engineer or architect may not fulfill the needs of a construction contractor or even another civil engineer or architect that are involved in the same project. Because each hydrogeologic or geologic study is unique, each hydrogeologic or geologic report is unique, prepared solely for the specific client and project site. Our report is prepared for the exclusive use of our Client. No other party may rely on the product of our services unless we agree in advance to such reliance in writing. This is to provide our firm with reasonable protection against open-ended liability claims by third parties with whom there would otherwise be no contractual limits to their actions. Within the limitations of scope, schedule and budget, our services have been executed in accordance with our Agreement with the Client and generally accepted hydrogeologic practices in this area at the time this report was prepared. This report should not be applied for any purpose or project except the one originally contemplated. A HYDROGEOLOGIC OR GEOLOGIC REPORT IS BASED ON A UNIQUE SET OF PROJECT-SPECIFIC FACTORS Insight Geologic considered a number of unique, project-specific factors when establishing the scope of services for this project and report. Unless Insight Geologic specifically indicates otherwise, do not rely on this report if it was: • not prepared for you, • not prepared for your project, • not prepared for the specific site explored, or • completed before important project changes were made. If important changes are made after the date of this report, Insight Geologic should be given the opportunity to review our interpretations and recommendations and provide written modifications or confirmation, as appropriate. —tIRSURF CE CONDITIONS CAN CHANGE This hydrogeologic or geologic report is based on conditions that existed at the time the study was performed. The findings and conclusions of this report may be affected by the passage of time, by manmade events such as construction on or adjacent to the site, or by natural events such as Developed based on material provided by ASFE, Professional Firms Practicing in the Geosciences, www.asfe.org. INSIGHT GEOLOGIC,INC. LIMITATIONS floods, earthquakes, slope instability or ground water fluctuations. Always contact Insight Geologic before applying a report to determine if it remains applicable. MOST HYDROGEOLOGIC AND GEOLOGIC FINDINGS ARE PROFESSIONAL OPINIONS Our interpretations of subsurface conditions are based on field observations from widely spaced sampling locations at the site. Site exploration identifies subsurface conditions only at those points where subsurface tests are conducted or samples are taken. Insight Geologic reviewed field and laboratory data and then applied our professional judgment to render an opinion about subsurface conditions throughout the site. Actual subsurface conditions may differ, sometimes significantly, from those indicated in this report. Our report, conclusions and interpretations should not be construed as a warranty of the subsurface conditions. HYDROGEOLOGIC REPORT RECOMMENDATIONS ARE NOT FINAL Do not over-rely on the preliminary recommendations included in this report. These recommendations are not final, because they were developed principally from Insight Geologic's professional judgment and opinion. Insight Geologic's recommendations can be finalized only by observing actual subsurface conditions revealed during construction. A HYDROGEOLOGIC OR GEOLOGIC REPORT COULD BE SUBJECT TO MISINTERPRETATION Misinterpretation of this report by other design team members can result in costly problems. You could lower that risk by having Insight Geologic confer with appropriate members of the design team after submitting the report. Also retain Insight Geologic to review pertinent elements of the design team's plans and specifications. Contractors can also misinterpret a hydrogeologic engineering or geologic report. Reduce that risk by having Insight Geologic participate in pre-bid and preconstruction conferences, and by providing construction observation. DO NOT REDRAW THE EXPLORATION LOGE Hydrogeologic engineers and geologists prepare final boring and test pit logs based upon their interpretation of field logs and laboratory data. To prevent errors or omissions, the logs included in a hydrogeologic engineering or geologic report should never be redrawn for inclusion in architectural or other design drawings. Only photographic or electronic reproduction is acceptable, but recognize that separating logs from the report can elevate risk. READ THESE PROVISIONS CLOSELY Some clients, design professionals and contractors may not recognize that the geoscience practices (hydrogeologic engineering or geology) are far less exact than other engineering and natural science disciplines. This lack of understanding can create unrealistic expectations that could lead to disappointments, claims and disputes. Insight Geologic includes these explanatory "limitations" provisions in our reports to help reduce such risks. Please confer with Insight Geologic if you are unclear how these "Report Limitations and Guidelines for Use" apply to your project or site. INSIGHT GEOLOGIC,I NC. LIMITATIONS HYDROGEOLOGIC, GEOLOGIC AND ENVIRONMENTAII RFPOPT-:� !}HOJ.11_n n'O.T P. INTERCHANGED The equipment, techniques and personnel used to perform an environmental study differ significantly from those used to perform a hydrogeologic or geologic study and vice versa. For that reason, a hydrogeologic engineering or geologic report does not usually relate any environmental findings, conclusions or recommendations, e.g., about the likelihood of encountering underground storage tanks or regulated contaminants. Similarly, environmental reports are not used to address hydrogeologic or geologic concerns regarding a specific project. INSIGHT GEOLOGIC,INC. LIMITATIONS MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY WALL REPAIR PLANS 10 NSUNDOW.NDRIVE LAKE CUSHMAN, HOODSPORT, WA CLIENT.- SHEET INDEX DA VID E. ANDERSON NO. DESCRIPTION C-01 COVER SHEET APPROXIMATE C-02 GENERAL NOTES PROJECT LOCATION LAT: 47.49 C-03 SITE PLAN LONG:-123.241 C-04 PROFILE VIEW C-05 SECTION VIEW C-06 SECTION VIEW C-07 SOIL NAIL DETAILS N C-08 NAIL SCHEDULE W E Engineering and Architectural Drawings Construction must match all designs and specifications of the VICINITY MAP Architectural and or the Engineering requirements OR a stamped letter of approval must be provided from the design professional responsible for 1 the work that has been altered.—NOTE:Structural engineering shall 1 (NOT TO SCALE) supersede Mason County"Typical"notes for structural items.— 100% DESIGN I SHEET REVISIONS PROJECT NAME: OtAwsv,.dwJ-17swu DATE DESCRIPTION NO 08/16/24 ISSUED FOR REVIEW IFR 10 NSUNDOWNDRIVE 001\ - � Rs 08122124 ISSUED FOR PERMIT 0 Dm:2o24.0ea A. SEC '{ SHEET TITLE: *9= �4� OF WAS 9,p COVER SHEET Gea5tabilization Internatinnal y z 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA NT�G 2202an4 vaa scrum T�r1EP�PPoE�TAAY P'FOfWAT70N 5MO�%iN 1�EftEON IS HOT Toes DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET Phone:855.579.0536 i Fax:970.245.7737 �,o �URALE�G` TLws TTD�'TIHa�n�T.Wn��H u Is 06t-Y�IFDley www.geostabilization.com �`rjONALti�G CONSTAV(,TED M'DSVPERviSED BY G5I DR RS AURIORI�D SUBCOHTAwCTOK JAG DRH DRH 8/16/24 17137, 244118WAON C-01 Changes Reviewed for Code Compliance Joshua Luck Submit changes for approval Mason County Building prior to performing work Department """"" Approved for Issuance MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY CONSTRUCTION SEQUENCEIWORK SCHEDULE: OF TOP OF SHOTCRETE. BARS SHALL NOT BE FORCED INTO THE DRILL HOLE.IN HOLES WHERE RESISTANCE THE CONTRACTOR WILL PROVIDE AND INSTALL THE SPECIFIED SOIL NAILS AND SLOPE IS ENCOUNTERED DURING BAR INSTALLATION,THE HOLES SHALL BE CLEAND AND SURFACE TREATMENT PER THE CONSTRUCTION DOCUMENTS. THE ANTICIPATED REINFORCING STEEL PLACEMENT: INSPECTED PRIOR TO REPLACING THE TENDON. CONSTRUCTION SEQUENCE IS AS FOLLOWS: ? REINFORCING SHALL BE PLACED SUCH THAT THE MINIMUM CONCRETE COVER IS S GROUT INSTALLATION METHODS MAY BE ADJUSTED UPON GSI ENGINEER APPROVAL PROVIDED AS SHOWN. BASED ON SITE CONDITIONS DURING INSTALLATION. 1. DELINEATE LIMITS OF STABILIZATION.NOTIFY LOCAL UTILITIES PROVIDERS TO S REBAR WILL BE TIED TO THE WIRE MESH IN THE SHOTCRETE PORTION OF THE S DRILL HOLES SHOULD BE VISUALLY INSPECTED FOR GROUT LOSS.SOIL NAILS LOCATE AND MARK POTENTIAL UNDERGROUND FACILITIES.DAYLIGHTING OF STABILIZATION SYSTEM. VERTICAL AND HORIZONTAL BARS WILL BE PLACED AS SHOWING SIGNS OF GROUT LOSS MAY BE FILLED BY PLACING A TREMIE GROUT PIPE UTILITIES IN POTENTIAL CONFLICT.AS NECESSARY. SHOWN IN THE CONSTRUCTION PLANS. INTO THE DRILL HOLE UNTIL IT REACHES THE GROUT COLUMN.GROUT WILL BE 2. PREPARE THE WORK AREA FOR STABILIZATION CONSTRUCTION. NON-CONTACT SPLICES OF THE REBAR WILL NOT BE REQUIRED.21. PREPARE SITE ACCESS. PLACED UNDER GRAVITY PRESSURE UNTIL GROUT RETURN IS OBSERVED AT THE 2-2- SURFACE.DRILL HOLES SHOWING SIGNS OF MINOR GROUT LOSS MAY BE TOP INSTALL TEMPORARY EQUIPMENT ANCHORS AS REQUIRED. BEARING PLATE PLACEMENT: FILLED. 23. PREPARE WORKING FACE BY INSPECTING AND REMOVING DELETERIOUS S 8-X 8-X 318"STEEL BEARING PLATES WILL BE PLACED OVER THE NAILS AND MATERIAL ATTACHED WITH A HEX NUT TO SECURE THE MESH AND REBAR DURING SHOTCRETE 24. PROTECT EXISTING HOME WITH PLASTIC SHEETING AND PLYWOOD AS NEEDED. PLACEMENT. IF THE SOIL NAILS EXTEND BEYOND THE HEX NUTS OR WELDED 3. MARK THE LOCATIONS OF THE PROPOSED SOIL NAILS WITH SURVEY MARKING PAINT. PLATES,THEY WILL BE TRIMMED. 4. INSTALLATION OF SOIL NAILS. 5. PLACEMENT OF 6. PLACEMENT OF BEARING PLATTES,HEX TE I"NUTS,REINFORCING STEEL,AND ANY S"°TCRETE: SPECIAL INSPECTIONS S+ REQUIRED S *SPECIFICATIONS MIX DESIGN SHAH COMPLY WITH THE REQUIREMENTS OF ACI 5062, (CONCRETE/SHOTCRETE) CO N C RETE�S H OTC RETE) REPORTS REQUIRED FORMWORK 'SPECIFICATIONS FOR MATERIALS,PROPORTIONING AND APPLICATION OF `l! 7. GSI TO PERFORM SITE RESTORATION. SHOTCRETE",UNLESS OTHERWISE APPROVED BY GSI ENGINEER. 7.2 EXPOSE AND REMOVE7A. REMOVE ON ANYDTEMIPORARY EQUIPMENT ANCHORS AT LEAST 24" SET TIME CONTROLLING ADDITIVES(I.E.HYDRATION STABILIZERS,RETARDERS)MAY MUST BE SUBMITTED TO THE BUILDING BELOW FINAL GRADE. BE USED PER THE MANUFACTURER SPECIFICATIONS AND UNDER THE DIRECTION Of A GSI ENGINEER. DEPARTMENT UPON COMPLETION. SEE SHO CRETE MIX IGN MAY BE HOUSE KEEPING: S AVAIILLABILIlY,AND SITEMEATHEADJUSTED CON IT o�BiAS. ON`°c`u SUPPLIERS, ATTACHED SPECIAL INSPECTION 5 THE SITE WILL BE ORGANIZED AND CLEAR OF ANY TRASH OR DEBRIS. ALL TRASH WILL BE LACED IN A PROPER CONTAINER AND REMOVED AT THE END OF EACH WORKDAY SHOTCRETE MIX DESIGN: AGREEMENT FOR MORE INFORMATION S MINIMUM 28 DAY COMPRESSIVE STRENGTH:3000 PSI SAFETY: TARGET WATER TO CEMENT RATIO:0.4 TO 0.5 5 ALL SAFETY PLANS FOR LIFTING,HEARING,DUST CONTROL,PPE ETC,WILL BE IN TARGET SLUMP:3 TO 4 INCHES PLACE AND FOLLOWED ACCORDINGLY. PPE INCLUDES SAFETY VEST,STEEL TOED TARGET GRADATION:ACI NO.2 OR AS APPROVED BY GSI ENGINEER. SHOES,HARD HAT,SAFETY GLASSES,RESPIRATOR DURING DUST PRODUCING ACTIVITIES,AND GLOVES. S ALL FIELD PERSONNEL SHALL ATTEND SITE SPECIFIC ORIENTATION PRIOR TO BEING SHOTCRETE APPLICATION: ON SITE,AS REQUIRED. 1 SHOTCRETE WILL BE PLACED FROM THE LOWER PART OF THE AREA UPWARDS TO DAILY PREIPOST JOB BRIEFINGS WILL BE HELD AND DOCUMENTED;ALL ON SITE PREVENT ACCUMULATION OF REBOUND. THE NOZZLE WILL BE ORIENTED A PROPER PERSONNEL WILL BE REQUIRED TO REVIEW AND SIGN DISTANCE FROM AND APPROXIMATELY PERPENDICULAR TO THE WORKING FACE SO THAT REBOUND WILL BE MINIMAL AND COMPACTION WILL BE MAXIMIZED. CARE WILL QUALITY CONTROL SCHEDULE EMPLOYEE CERTIFICATIONS: BE TAKEN WHILE ENCASING REINFORCING STEEL AND MESH TO KEEP THE FRONT ACI SHOTCRETE NOZZLEMEN CERTIFICATION FACE OF THE REINFORCEMENT CLEAN DURING PLACEMENT OPERATIONS,SO THAT DESCRIPTION FREQUENCY REFERENCE/CRITERIA S 10-HOUR OCCUPATIONAL SAFETY AND HEALTH TRAINING COURSE IN CONSTRUCTION SHOTCRETE BUILDS UP FROM BEHIND,TO ENCASE THE REINFORCEMENT AND SAFETY&HEALTH PREVENT VOIDS OR POCKETS FROM FORMING. DILL LOGS EVERY SOIL NAIL RECORD DATA PER SHEET C-14 AMERICAN RED CROSS STANDARD FIRST AID TRAINING 2 PRODUCTION NAILS,TEST i AMERICAN RED CROSS BLOODBORNE PATHOGENS TRAINING:PDT GROUT MIX DESIGN: PROOF NAIL TEST AFTER 48 HRS FHWA 14-007,2015 SIZE AND TYPE OF NAILS: S WATERICEMENT RATIO=0.5 TO 0.6 MUD BALANCE READINGS ONCE EACH DAY OF SEE SHEET C-02&C-09 FOR MIX 1 THE SOIL NAILS SHALL BE AS SHOWN IN THE CONSTRUCTION PLANS.INSTALL OF NO. S DENSITY RANGE:112.2-108.6 PCF (SPECIFIC GRAVITY) GROUTING DESIGN AND DATA LOG 6 SOLID THREADBAR TENDONS AS SHOWN UNLESS UNSTABLE HOLE CONDITIONS t PORTLAND CEMENT:TYPE I/TIN OR EQUIVALENT ARE ENCOUNTERED. T40/18 HOLLOW BAR SOIL NAILS ARE ACCEPTABLE AS ALTERNATIVE ANCHORS.IF UNSTABLE HOLE CONDITIONS ARE ENCOUNTERED. (PER 94#BAG OF CEMENT) S ALL ASSOCIATED ANCHOR HARDWARE SHALL HAVE A CAPACITY NOT BE LESS THAN MATERIAL WEIGHT VOLUME MIX RATIO THE FULL ULTIMATE CAPACITY OF THE BAR TENDONS USED. CEMENT 94 LBS 0.47 FT3 1 BAG(94#) FACING AND DRAINAGE SYSTEM: WATER 47 TO 56.4 LBS 0.75 FT'TO 0.09 FT' 5.12 GALLONS TO 5.47 GALLONS DRAIN STRIPS WILL BE PROVIDED AND INSTALLED BETWEEN THE SOIL NAILS PER I THE CONSTRUCTION DOCUMENTS.DRAIN STRIPS WILL BE CONTINUOUS AND ANY NAIL INSTALLATION AND GROUTING: SPLICES SHALL BE MADE WITH A ONE-FOOT MINIMUM OVERLAP SUCH THAT THE ALL NAILS SHALL BE TREMIE GROUTED CONCURRENTLY WITH PLACEMENT OF BARS 100% DESIGN FLOW OF WATER IS NOT IMPEDED. NO DRAIN STRIPS WILL BE LOCATED WITHIN 18" INTO THE DRILLED HOLES. SHEET REVISIONS PROJECT NAME: viaery.vba w aer s>.. pt aus. DATE DESCRIPTION NO 08/16/24 ISSUED FOR REVIEW IFR 1 D NSUNDOWNDIZIVE 0822/24 ISSUED FOR PERMIT 0 0a'202�. m;]lua.oaa 1107 07asva F� A. S'PG sHEET TITLE: �� OF W ASy� Q� GENERAL NOTES 6aen5tab€1€zat€nn Internatianal= y z 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA N'`pG 22024774 TM'SDRA NGisr111tNI sa-ELY101 THE USE ova IN1,1.+Ell H ws DRAWN BY: DESIGNED BY: CHECKED BY. DATE: PURSUIT NUMBER PROJECT NUMBER SHEET Phone:855.579.0536 1 Fax:970-245.7737 �URALEIG`�`�� PROJECT ANO TIE PRORPoEiMYUTAT.WORSIGN'N REREONISH nBE vrww.geostabilization.com �S' G TWiS EOSTA OANYOTMERCR TIONAT(GSI),I EDESIGN IS LYV&MIF BY ���� a 0o s,a�uc�, n� na GSIo ITSNrmoRGL"-o�s�e`YG«TP_kCTM JAG DRH DRH 8/16/24 171374296 244118WAON C-02 Changes Reviewed for Code Compliance Submit changes for approval Joshua Luck Mason County Building prior to performing work Department """`'"" Approved for Issuance MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY 4-1 PROPOSED SHOTCRETE WALL STA 0+00 TO STA 0+55 f „r • w.4-hrig- twvvards Holse E rz r 5 9 o '' hO l X Se r pg ESTIMATED QUANTITIES PAY ITEM OTY OTY UNIT c ? yt : t` t € £ d UP EA ! °V 6 ° u e I 1 c STEEL PLATES 25 EA FURNISH&INSTALL 550 SF SHOTCRETE STRIP DRAIN 83 LF y .rf f f ^'• . ti� t W E t / I s i T f 1 ON a�. 1- 100% DESIGN SHEET REVISIONS PROJECT NAME: . D§ Cr d91,ed ey part swan DATE DESCRIPTION NO j: EaeeC-Usesye '�. 08116t24 ISSUED FOR REVIEW IFR 10 N SUNDO WN DRIVE � 08/22/24 ISSUED FOR PERMIT 0 {� r m24.0ea��� �� A- SFG ��SHEET TITLE: � ��'�p� WASy� SITE PLAN c� Gea5tatlittzation Intemattanat� he z 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA �� 22024T74 wV4�L� T sDR w*c�FVR+SN®So�YFOR,rIII.BEIORWCO« lCnO.m I's Phone:855.579.0536 1 Fax:970.245.7737 �+��J�RALE��'`�`� PROJECTMDTEPROPRIEf YINFORfMMNSNG. HERSONISNOTT09E DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUITNUMBER: PROJECT NUMBER: SHEET U TRANSWTTEO TIIMYOTHEROROANIZATIONWRHOUT SPECJFICAVn10WIAT 81 www.geostabilization.com s'sl CANSTR pANO�I�nBYYGS1(o r:sAu CWZFDs°eYca"'DrnACTOR JAG DRH DRH 8116/24 171374296 244118WAON C-03 AL L Changes Reviewed for Code Compliance Submit changes for approval p Joshua Luck prior to performing work Mason County Building Department Approved for Issuance MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY NOTES: ALL DISTANCES ARE SLOPE DISTANCE UNLESS NOTED OTHERWISE. NOTIFY ENGINEERING IF COMPETENT APPROXIMATE SOIL IS NOT ENCOUNTERED WHILE DRILLING. APPROXIMATE LOCATION LOCATION OF PROTECT EXISTING STAIRWAY. OF EXISTING TIMBER EXISTING STAIRWAY MODIFICATION OF SOIL NAIL LOCATION AND ORIENTATION ACCEPTABLE PER DIRECTION FROM GSI ENGINEERING. TEST NAIL INFORMATION: _j BONDED LENGTH: 18(FT) J Q C) tO _j ,'i UNBONDED LENGTH:3(FT) z + + Q + HOLE DIAMETER:4(IN) 1 5'-0" f SHOTCRETE p C BOND STRENGTH: 1,000(LB/FT) 1'6" m � TYP FACING PROTECT EXISTING w � CORRUGATED DRAIN 1 2 3 a El El a 8 9— El El 1 2 3 4 5 6 7 8 9 i 10 11 a C) L 4 22 m 21 0 o a o �- 0 o a o '$ o a in o a Tn F- A a it � C-07 23 24 25 SOIL NAIL EXTENDED GEOCOMPOSITE STRIP DRAIN BELOW SHOTCRETE WALL,TYP LEGEND 0 UP TO 20'-0'SOIL NAIL i TYPICAL PROFILE _ h SCALE: 1"=5' t 100% DESIGN o4nvb Wined by JeR Sg" PROJECT NAME: SHEET REVISIONS DN ems. DATE DESCRIPTION NO "Ipa 08/16/24 ISSUED FOR REVIEW IFR 10 NSUNDOWNDRIVE tnt-Wr �y.. 08/22/24 ISSUED FOR PERMIT 0 n m 4.oe22 ays�ar F� BG SHEET TITLE: dr�—VAr—m-a —� �� p� WAS C, PROFILEVIEWS Ge 0225 Wes moor rive,Suite 205 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA ;0 Nip 22024774 T dS OB WNGISt dSMEOSOUFLYFORTHEUS OfO 'N NNearwnvm s DRAWN BY: DESIGNED BY: ICHECKEDBY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET Phone:855.579.0536 1 Fax:970.245.7737 OGCTURALENG`�`�� TRA�11o,5=M To�011 ROR IZN TI(ak no TOSSN FIE-0NLS.N IONO BE BY www.geostabilization.com MNST�RI.�c�TID�05t�1PERVISEDnHY°m ail.n�psi�SUSYVALJO IF C To0. JAG DRH DRH 8/16/24 171374296 244118WAON C-04 �NALE Changes Reviewed for Code Compliance Submit changes for approval p Joshua Luck prior to performing work Mason County Building 40Approved for Issuance Department MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY EXISTING STRUCTURE NOTES: PROTECT FROM DAMAGE LEAVE EXISTING TIMBER STRUCTURE ESPECIALLY OVERSPRAY IN-PLACE AS PRACTICAL VARIES MIN.5' EXISTING TO BE REMOVED BY OWNER EXISTING TIMBER WALL TO BE STABILIZED IN PLACE 6"NOMINAL REINFORCED - SHOTCRETE a NAIL SOIL L EXISTING TIMBER A WALL C-07 15't5° UP Tp 2 p,�MgFpti1E TYP NrL�NGrN �P TYPICAL SECTION SCALE:1"=5' I 100% DESIGN SHEET REVISIONS PROJECT NAME: � �Ja^� DATE DESCRIPTION NO �� Eue°.6°°"�°'-'• 08716I24 ISSUED FOR REVIEW IFR 10 N SUNDOWN DRI VE V N ] 08/22/24 ISSUED FOR PERMIT 0 0rt 20240822 SEG SHEET TITLE: flj� .p SECTION VIEWS �� cT Geo5tabilization International h 2 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA THIS DRANTNG IS PERM R SOIELY FOR THE ISSE OF OR IN OONNECT1QV WfTH THIS . . . . PROEOT-ID THE PROPRIRARY biFOWAAnO ShC'—HEREON IS NOT TO BE DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: Phone:8555790536 SHEET I Fax:9702457737 OAF cTURAL TRANSNMED TO ANY OTHER ORG L'ATION W17HOIIT SPED FIC A ORVATION BY www.geostabilization.com ALF'�G ��TRUC/EI-D0 SUPE ED�(G�S�AV»SIRI ED SO4ve`YcoN�ucroR. JAG DRH DR H 8(16/24 171374296 244118WAON C-05 Changes Reviewed for Code Compliance Joshua Luck Submit changes for approval Mason County Building prior to performing work Department Approved for Issuance MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY NOTES: WORKING FACE(SCARP)PREPARATION: CLEAR WORKING FACE OF EXCESSIVELY LOOSE MATERIALS AND TRIM ALL VEGETATION FLUSH. THE WORKING FACE SHALL HAVE A RELATIVELY UNIFORM AND PLANAR SURFACE ALLOWING FINAL FACING TO BE HAVE A POSITIVE BATTER. — 6"NOMINAL REINFORCED SHOTCRETE SOIL NAIL SLOPED BENCH FOR POSITIVE DRAINAGE A Clp TO 20 C-07 FIb1QFOMFNTC�NGTN, 71 p 15"t5° TYP ATYPICAL SECTION ~ J SCALE: 1"=5' 100% DESIGN i SHEET REVISIONS PROJECT NAME: v �.ymabyJeffsegv ON:DATE DESCRIPTION NO EaleQSn2'C%si_. ,.}/� � � " 08/16/24 ISSUED FOR REVIEW IFR 10 NSUNDOWNDRIVE Al. J a-C_olw,cN�rts"yar 08/22124 ISSUED FOR PERMIT 0 OW 2024.0822 F N. SEC fSHEET TITLE: �� p� R ASy�Q� SECTION VIEWS cT 6ea5W�tlizatlon tnternattonal> h 2 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA N'pG u�Oza77a TNIS DMYANG ISF"SHED SOLELY FOR THE USE OF ORIN CONNECTION MTM THIS Phone:855.579.0536 1 Fax:970.245.7737 ,n G r�OJECT AND THE CRovwR,.m wFORUAnoN SHowI+nEREDN cs Nor To eE DRAWN BY: DESIGNEDBY: CHECKEDBY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET O�' URAL V-tk � TR 111781 TO ANY OTHER ORGAN¢AU.umlaut SPECIFIC AUT,1111.nON BY www.geostabilizafion.com �sIONAL��� MNSET�nr�0SLLiEXASEDnBYGS1Mo AAUT�ORG�"OSUBCOWRACToa JAG DRH DRH 8116/24 171374296 244118WAON C-06 Changes Reviewed for Code Compliance Submit changes for approval Joshua Luck prior to performing work Mason County Building -Department Approved for Issuance MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY NOTES: (SEE NOTE 4) 1. ALL SOIL NAIL HEAD HARDWARE SHALL BE EPDXY COATED. 2. LAP SPLICE LENGTH 2.1. NO.4 REBAR-24"MINIMUM WALERS(REBAR) DRAIN STRIP 3. WELDED WIRE MESH TO HAVE A MINIMUM OF 8"OVERLAP(2 SQUARES OVERLAP FOR 4 x 4 MESH). STEEL PLATE TO BE WET SET 4 x 4-W2.9 x W2.9 WELDED 4. REBAR CHAIRS OR EQUIVALENT TO WIRE MESH(ASTM A185) BE USED TO ENSURE SUFFICIENT Cl) O CONCRETE COVER BETWEEN WELDED WIRE MESH (2)36"LONG NO.4 GRADE 60 BARS GROUND SURFACE AND ZD VERTICAL EACH SIDE OF NAIL REINFORCEMENT.2 TO 3 DOBIES PER (2)CONTINUOUS NO.4 5'x 10'SHEET OF MESH,TYPICAL. GRADE 60 BARS HORIZONTAL 5. HORIZONTAL WALERS ARE BIRDS BEAK 8"x 8"x 3/8"A36 STEEL PLATE CONTINUOUS (SHOTCRETE OR GROUT BACKFILL) � 6. INSTALL CENTRALIZERS ALONG THE Ct LENGTH OF THE SOIL NAIL AT TYPICAL AVAIL HEAD INTERVALS NOT GREATER THAN 8' LENC'�NP�RP FROM EACH OTHER.THE N HEX NUT CENTRALIZERS ON THE ENDS OF THE NAIL SHALL BE INSTALLED 1.5'FROM PER PLAN THE COLLAR OF THE HOLE AND THE I BEVELED WASHER BOTTOM OF THE HOLE. 1" MIN — 6"NOM.3,000 PSI SHOTCRETE 75 KSI-NO.6 EPDXY COATED UNDISTURBED GUN FINISH THREADED BAR(ASTM A615) REBAR CHAIRS OR SIMILAR 3,000 PSI NEAT CEMENT GROUT (SEE NOTE 3) CENTRALIZERS 4"0 ORILLHOLE MIN. 3 MIN STANDARD DETAIL SCALE:1"=1' i 100% DESIGN ° SHEET REVISIONS PROJECT NAME: DN:Cp siymd Oy bR Sogar DATE DESCRIPTION NO ENa-say®s�+. 08116124 ISSUED FOR REVIEW IFR 10NSUNDOWNDRIVE 08/22/24 ISSUED FOR PERMIT 0 °' o i SHEET TITLE: 'I ��C OF WAS qjf .p SOIL NAIL DETAILS GeaStahilizatinn lnternatianal'- z 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA "Op pG 224774 Is DRAW NG S FUR ISM®SO E Y Ea TME O.« coNNEcnon wm is Phone:855.579.0536 1 Fax:970.245.7737 OAF R pL E G��`tL vaacc�i ronE—OwMET�xYinowyno snwn r FIEO IS OTTOM DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER: SHEET U r1 fi MA TTIW TO ANY OT ORGANIZATION WRYiOUT SYEgFIC AIRNOR{7AnON BY www.geostabilizabon.com �if'f �G CONOSTR hpANowvEmasener SI,MITS�RJZEDSUBCOWM ONLY ACTOR JAG DRH DR H 8/16/24 171374296 244118WAON C-07 �NAL� Changes Reviewed for Code Com liance Submit changes for approval p Joshua Luck — prior to performing work Mason County Building -Department Approved for Issuance MUST COMPLY WITH PERMIT Mason County Permit Document CONDITIONS BLD2024-01082 SITE COPY NAIL ID DATE EMBEDMENT LENGTH(ft) MUD BALANCE TESTING-SPECIFIC GRAVITY(ASTMD4380) DRILLED GROUTED SOIL ROCK 1 2 DATE NAIL ID' READING-SP.GR.(1.75-1.84,TYP GSI)" 3 4 5 6 7 8 9 APPROXIMATE NAIL NUMBER GROUTED WITH SAMPLED BATCH. 10 SAMPLE SHALL BE TAKEN FROM END OF GROUT HOSE. • 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 >t i t i 100% DESIGN SHEET REVISIONS PROJECT NAME: tio. , y J'ffS a ON:An! ft DATE DESCRIPTION NO l ecre2s�pcAprn., 08116f24 ISSUED FOR REVIEW IFR 10 N SUNDO WN DRI VE ] 08/22/24 ISSUED FOR PERMIT 0 /Lt r ram 2=,I..c2 seas uca F N. S CG SHEET TITLE: I �Fi�pF WAS 9� NAIL SCHED ULE — cT GeoStabilization International 10225 Westmoor Drive,Suite 205 Westminster,CO 80021 USA m��G 22024774 F`4cp� TNUDR,vnN�Is RNSN�nS«�YF«+TNE1Iseo`oaMcoNNEc*a vmN N5 Phone:855.579.0536 I Fax:970245.7737 0,n PROF_CT-O� EPROPRUE LNFOM1A N5HO—IHEREO IS NOT TO BE DRAWN BY: DESIGNED BY: CHECKED BY: DATE: PURSUIT NUMBER: PROJECT NUMBER SHEET �` URAL fi o�suw W IONINFV' TITIO LOGS. EDESIGNISONLY ^B EY www_geostabilization.com rr70NALE�G 7i c0NSTRucreo,w0w WSEDBY¢SIORrrSlumwR¢EGsvacorm+^crori JAG DRH DRH 8116124 171374296 244118WAON C-08 Changes Reviewed for Code Compliance Joshua Luck Submit changes for approval Mason County Building prior to performing work Department Approved for Issuance 'IZ3f - 5-0 oaoil � �T SITE COPY s REVIEWED FOR CODE COMPLIANCE MASON COUNTY ByIL�G DEPARTMENT Date L