HomeMy WebLinkAboutBLD2011-00547 Final SFR - BLD Permit / Conditions - 12/7/2011 4 Inspection Line(360)427-7262 IPMASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 , \� RESIDENTIAL BUILDING PERMIT BLD2011-00547 OWNER: ' MUELER &TOLBERT RECEIVED: 7/5/2011 CONTRACTOR: STEPHEN JOHNSON, INC 1.360.275.6734 LICENSE: STEPHJ"199LW EXP: 6/16/2012 ISSUED: 8/9/2011 SITE ADDRESS: 1741 NE TAHUYA BLACKSMITH RD TAHUYA EXPIRES: 2/9/2012 PARCEL NUMBER: 223305000233 LEGAL DESCRIPTION: HAVEN LAKE TR. 233 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE ST RT 3 TO BELFAIR, L ON ST RT 300/NORTH SHORE RD, R BELFAIR TAHUYA RD, R ON TAHUYA BLACKSMITH RD TO SITE ON THE LEFT SIDE General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3/U Lot Size: Deck: Type of Work: NEW Fire Dist.: 8 No. of Stories: 1 Occ. Load: Building:1,438 Garage-Attached 768 Valuation: $ 179,788.94 Building Height: 18 Occ. Status: Primary Basement: COV PORCH 242 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 40.0 Ft. Shoreline: Ft. Water Body: Rear: W 190.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: S 10.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: N 15.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 2 Furnace<100K 1 Plan Check Fee TW 7/5/2011 $937.14 S120110001 Lavatories 2 Heat Pump 1 Planning Review Fee TW 7/5/2011 $205.00 S120110001 Bath Tubs 2 Ventilation Fan 3 EH Plan Review MRB 7/5/2011 $103.00 S62011000i Water Heaters 1 Propane Tank 1 Water Adequacy Plan Review MRB 7/5/2011 $103.00 S620110001 Clothes Washer 1 Gas Outlets 1 Building State Fee LDK 7/28/2011 $4.50 S120110001 Kitchen Sink 1 Propane Stove 1 Building Permit Fee LDK 7/28/2011 $1,441.75 S120110001 Dishwasher 1 Dryer Vent 1 Mechanical Permit Fee LDK 7/28/2011 $237.90 S120110001 Hosebibs 2 Exhaust Hood 1 Mechanical Base Fee LDK 7/28/2011 $28.50 S120110001 Plumbing Permit Fee LDK 7/28/2011 $93.20 S120110001 Plumbing Base Fee LDK 7/28/2011 $24.70 S120110001 Total $3,178.69 BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2011-00547 CONDITIONS FOR BLD2011-00547 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potenJ411 risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647- .TI a person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) Owner/Agent i esp Bible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 3) Approved per dirk sions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 4) Temporary erosion control measures must be implemented to prevent water quality degradation of adjagOTnTwaters or properties. Silt fencing, straw, or jute matting must be installed and maintained until upland vegetation has become established. X 5) Prior to final approval, all upland areas disturbed or newly create struction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 6) All construction and demolition debris must be removed fro site after project completion. Proper disW-s-aTqf construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X 7) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to a hese structures are shown and meet the setback conditions listed. X 8) By definition, propane tan s and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet th back conditions listed. X -$- ) - 61-1 BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 2 of 7 9) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the tic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowle in at all components of the stormwater management system have been installed as approved on the stormwater site plan. X 10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any fufthfr inspections being performed or approvals granted. X 11) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is respgnsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved docume wil result in failure of required building inspections. X 12) All slabs within the heated space shall be insulated to a minimum r at least 24". Monolithic slabs shall be insulated around the perimeter from the top of the slab to the bottom of the footing X 13) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. XL 14) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department p r o any further inspections being performed or approvals granted. X 15) Washington Stater—n-e- Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option III, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following c rom Table 9-1 shall be completed: 6 X BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 3 of 7 16) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration, and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area (SLA) when tested with a blower door at a press of 50 Pascals (0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate"and are available in X or'/2 sheets. The Mason County Permit er will also have some available. X 17) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Reference WSEC 505. X 18) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installatErManagement ns. X 19) A Mason County Sto Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with he septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is ack wle that all components of the stormwater management system have been installed as approved on the stormwater site plan. X ' 20) Owner/builder assumes all responsibility if drainfield/reserve ar4 s encumbered. A. Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No foundation drai n 30ft, down gradient of drainfield/reserve area. X BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 4 of 7 21 Concrete used for basement walls foundation walls, exterior walls porches, carport slabs h garage floor slabs and other a s, a , p p , steps exposed to the weather, g g vertical concrete work exposed to the eather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 22) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect " county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 23) All construction st meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occ ancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. L 24) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project.) 25) Placement of structure must mply with standards set forth per the international codes regarding descending and/or ascending slopes. X 26) All changes to "appro " u7illdiDg plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, m e r wed and approved by Mason County prior to construction. X 27) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international cod amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be m prior questing additional inspections. X BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 5 of 7 28) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 5-ft or as specifAin the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X 29) All propane tanks must nstalled in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X 30) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet the installation requireme an inimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X 31) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be used until the final inspecti as een performed and approved by a Mason County building inspector. X 32) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think such featuresAw4qLoff or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 33) All property lines shall be clearly identified at the time of foundation inspection. X 34) All building permits shall have a final inspection performed and approved by the Mason County wilding Department prior to permit expiration. The failure to request a final inspection or approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances 41 ding regulations. Xf 35) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (older have prevented action g taken. No more than one extension may be granted. 36) Pressure treated wood ma �ac/tured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. In tal connectors approved for contact with the new types of pressure treated material. X BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 6 of 7 37) Retaining walls needed to support a surcharge ch a s ctures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants a Mas o ty ac ss to t abo described property and structure for revi w an I inspection. OWNER R AGENT: DATE: BLD2011-00547 Please refer to the following pages for conditions of this permit. Page 7 of 7 o CONCRE MECHANICAL MANUFACTURED HOME c o � Footing Setb s Gas Piping BYE-- Ribbons r oInterior Da By interior-Date 1c_Y13_11 By K bate ay M VExterior Date 6 , �BY Exterior-Date B Set-up Point Load!Isolated Footings INSULATION Date By 0 Bate By BG 1 SLAB INSULATION - -- Data 13 FIRE DEPARTMENT pip Foundation Walls Floors Date By M Date y,. Data By DECKS FRAMING 7 Walls Date By pafp d By Data / By PROPANE TANKS PLUMBING vault Datc"I By Date lay OTHER Groundwork Attic Date By Type- Date By Date By mw.v DRYWALL Type- Int Brace Wall Date By, W _13 Date 10— . By _2 1 m Date 8 FINAL INSPECTION m Cn Water Lute I Fire Separation j / Q Date 13Y Date By `D \(/ Date /L ��� BY2 a o Pass or Request I nspect, CD c Type of Insp. Fail Date Date Done By Comments CD 0 0 G� o' Cn ICD _S t 1�}V H/ tr ti-> v co o -« t Building Permit # ' MASON COUNTY " BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location I 7'/i /8 This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been ound: Items Listed below must be corrected to gain code compliance �G .. yT � d mow ? You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department BLS Date Inspector moos � K � T ' u N �T '� M V T 1 � Building Permit'# MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTI E Job Location h -La 9 c This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance C"�'C_����___�C��i�/"J'�` ,.4-r C ��C� �/C ,�Sc� X/:- C L� �✓��X7r 3) 4 You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection -4 OK to e-,,- , v L Z/ e i ❑ This is not a co ete inspection Department Ll Date `/1 Inspector ,a C4 moos EovT MOOV T 1 T A ,� �d0� i lb\ ken IN wt,i 1p rr 2,17' 117q/ /v o-t- "c- . c- r ' se�a�-•c r`e.Sac-4e.Kc.el PLANNING . ALL SETBACKS ARE MEASURED FROM THE FURTHEST 0'�1 PROJECTION OF THE BUILDING 07 PLANNING gel� APPROVED MASON COUNTY DCD PLANNING SITE PLAN REQUIRED TO BE ON SITE CHANGES UBJET TO APPROVAL By pate�u (._Zv C( t�l�c,.�:��+►�� �c� o,,� h Name c.�,�¢ �4e r ITOIIXd Parcel# ZZ-3 o-0 b 0 2.33 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A).—K The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/d rain field system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further ac owl ge at the information provided is accurate and employees of Mason County are granted access to the above- descr' a op for view and inspection as may be required. X Owner/Age ontractor ircle one)Date: Page 2 of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition X _ above table Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area(sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 MASON COUNUwrW SNTIAL PLANS SUBMITTAL CHECKLIST L ( Reviewed BOwner's Name: � �/V'f Dater�I � Y Documents: Building Permit Application Completed --kStormwater Checklist Planning Intake Checklist Completed, Site plan includes: Allowable building area,roof overhangs,decks,etc. Fire Apparatus Access Road info required? Yes/No Energy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace ®Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) O Other: Specify: _Mechanical/Plumbing Application-WATER HEATER FUEL TYPE/LOCATION Engineering? Yes/No Snow load: Seismic: Stock Plan—approved snow load: Seismic: Manufactured Domes—4 FLOOR PLANS Foundation Type: ANSI/Manufacture method Engineered footing/foundation Basement Decks: Covered? Uncovered over 4 x 6 and over 30"? Construction plans required. Construction Plans:_3 COMPLETE SETS _Plans Legible _Recognized Scale _Elevation Views _Cross Section _Foundation Plan _Roof Framing Plan _Floor Plan-Use of rooms noted(all floors) _Floor Framing Plan-all floor levels including loft,crawlspace,etc. (<200 S.F. ??—stairs?) Deck Framing Plan,incl cov.porch framing Plan Details: r� Roof framing details,truss lay-out may be needed (Hip and girder location shown) f� Wall Framing-Does bearing-wall height exceed 10'?(Engineering maybe required) Z_X & l(e_rj �i Floor framing: Floor joists(size&spacing): ,Floor beams: �( Window headers. Typical header. _ 12./ Garage header: l X Foundation: footing size,reinforcement ` X 2� v Concrete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be required, see details) —4 Landings at all exits?Less than 30"above grade?Y/N Heated By Furnace-Location of Furnace (�01 g=iggg, Fuel type: �Fireplace/Stove Information Shown-Fuel Type?Tp� Locatzon(s): (il V 1 ` JK Window Sizes Marked on Plans Braced wall panels(shear walls)marked on plans or lateral engineering? X 2-story garage? (Engineering may be required) I'story of two story D1—45%,D2—55% COMMENTS: ENGINEERING REQUIRED Braced wall panels/brace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: Snow_psf. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3)End of BWP extends more than 1 ft over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces, chimneys,and veneer). When this applies the entire story shall be designed.In accordance with accepted engineering practice. H:\permit tech building checklist.doc Revised 11-29-2007 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/VIAQ Compliance Application Owner: p �—r- Telephone: �c Z Parcelk 2-Z `,3 n _5'6Q� Type of project New Residence ( )Addition ( ) Remodel Total Sq. Ft. 1 sFloor, ---Pnd floor: Heated Basement: of heated area:: 1 `4 J Heating System Type: O Electric wall heater O Electric Central Furnace O LPG Furnace Heat Pump with electric furnace O Heat pump with gas furnace O Boiler, specify fuel type: O Other: Specify Glazing O Prescriptive Option see reverse side circle one: 1 II IV Percentage: Compliance Method O Component Performance , Chapter 5— Calculation worksheets required r 3 % Check one:: t O Systems analysis, Chapter 4 Whole House Ventilation system O Whole House Ventilation using a Heat Ventilation si exhaust fans&window or wall fresh air S Stem vents (VIAQ 303.4.1) Recovery Ventilation System (VI.4Q 303.4.4) Y Check one O Whole House Ventilation Integrated O Whole House Ventilation using an inline with a Forced Air System (VIAQ 303.4.2) supply fan. VIAQ 303.4.3) Window & Door Schedule (If needed, attach an additional sheet) Total Manufacturer Room/location U-Factor Size Quantity Square Feet Windows: l b l a L dz 3 Y° y6 Z 32_ Windows: Total Sq. ft. Doors: 7, - 01 Doors: Total Sq. Ft Total window and door area ` Total window & door area L /(divided by)total sq. ft of heated area I q--3 13` ! _%of glazing I MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Assistance Center SHELTON (360) 427-9670 BELFAIR(360)275-4467 Elma (360)482-5269 FAx: (360)427-7798 WEB SITE: www.co.mason.wa.us P.O. Box 186, SHELTON 98584 2006 Washington State Energy Code (WSEC) 2006 Ventilation and Indoor Air Quality Code (VIAQ) Effective July 1, 2007 Code Compliance Application Form The following information will be required for the WSEC and VIAQ plan review: 1. Complete the Washington State Energy Code/Ventilation and Indoor Air Quality Code (WSECNIAQ) application located on the reverse side. 2. The window and door schedule should include all windows, skylights, sliding glass doors, french doors and any other door with 50% glass or more. Use rough opening dimensions of windows and doors to calculate size. It is always helpful to list the u-factors of windows and doors, if known. If you do not know u-factors, the plan reviewer will assume all window & door glazing will have a u-factor of.35 or less. When using the area weighted average method to comply with the prescriptive path include calculations with submittal documents. 3. On your building plans note the location and fuel type of heating system, water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of proposed insulation for walls, floors, ceilings, and slabs. Outdoor lighting, permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires or motion sensor with integral photocontrol photosensor. All linear fluorescent fixtures must be fitted with T-8 or smaller lamps, but not T-10 or T-12 lamps. To verify compliance, provide lighting information on plans. 4. Questions? Call Mason County Community Development at (360) 427-9670 ext. 352. Additional WSEC and VIAQ compliance information is also available on the WSU-Energy Program website at: http✓/www.energy,wsu.edu/codel Prescriptive Requirements " for Group R Occupancy Climate Zone 1, Table 6-1 Glazing Glazing U-factor Vaulted Wall Wall Wall Area%of Door Ceiling Ceiling3 Above interior exterior Slab 6 Option Floor overhead Ll s 2 see note Grade 4 below 4 Below Floor 5 on tp Vertical Ohead Factor below 12 grade Grade Grade I 10% .32 .58 .20 R-38 R-30 R-15 R-15 R-10 R-30 R-10 II* 15%* .35 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 IV Unlimited Single Family Res •35 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 (R-3)Only *Reference Case/Call (360)427-9670 ext.352 for footnote information. Log&solid timber wall with a min.avg.thickness of 3.5'are exempt from the above grade wall insulation requirements.Vaulted ceilings shall be limited to 500 sq.ft.of ceiling area for any one dwelling unit. FORM MUST BE COMPLETED IN INK MASON COUNTY PERMIT NO. 2DI1-925 -U PLEASE PRESS HARD BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner Evi U✓1� e l 1�r i V- (C' 1 r,`t Company Name Mail' Address 03 � o� o�� Mailin Ad ess �e x City g 'I se s State�Zip Code 3 City 1 State Zip Code Phones ���'��c1 c 1� Other Ph. Phone e36� Z�S �a73 � Other Ph. Lien/Title Holder Contractor Reg. L LIL"Exp. 9Z E mail address E Mail Address �e z .5��1',7 C • y-- Drivers Lic. # DOB Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic X Existing Septic Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION.- 12 Digit Parcel No. 2z- 3 C� Fire District Legal Description � a Z Site Address (Please include street name, street number and city) �5— cti 0< u, x J Directions to site Will timber be cut and sold in parcel preparation?Ye No Is property within 200' of Saltwater Lake River/ Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Yes/No TYPE OF JOB - ew Add Alt Repair Other PRIMARY RESIDENCE X SEASONAL ❑ Use of Building leS T E escribe Work No. of Bedrooms No. of Bathrooms Z Square Footage- 1st Floor —2nd Floor 3rd Floor—Basement Deck Covered Deck 2 L R'— Other Sq. ft. Garage Attached Detached -Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative, or the contractor. I further declare n o the work as proposed in the application. I declare that I have obtained the permission from all that I am entitled to receive this permit and to d p P PP the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.This permit/application becomes null & void if work or authorized construction is not commenced wit ' 180 days or if construction work is suspended for a period of 180 days. PROOF OF PONTINUATION OF WORK IS BY MEANS AO RES NSP CTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180,DAYS WILL INVALIDATE THE APPLICATION. X �� Date �T�h caner/Ow Representativ /Contractor (indicate which one) FOR OFFICIAL USE BEYOND T POINT Accepted by: V Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES � l] FORM MUST BE COMPLETED IN INK PERMIT NO. PLEASE PRESS HARD MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W.Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INF_QRMATION Owner �'--t vl 01 LA"_ I/F✓' ,S`� r y��� Company Name �e i��.-, C 6 6iq'i ta-, T-�►1L, Mailing Address Maili"�Ad ress � c, City State Zip Code tate Zip Code Phone Other Ph. Phone 3 6 c C>73 V Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. 7-Z-33 6 _5-0 0 U Fire District Legal Description Site Address (Please include street name, street number and city) Directions to site Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units - 1st Floor. 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNJTS Type of Fixture No. of Fixtures Fees Fuel Type:Electrir_ LPG— Natural Gas_ Heat Pump_ Toilets 2 Type of Unit No. of Units Fees Bathroom Sink — - Furnace Bath Tubs Heatpumps f Showers Spot Vent Fan 4 Water Heater r Propane Tank Clothes Washer Gas Ou ets / Kithen Sinks Woo a Pellet Stove Dishwasher Kitchen Exhaust Hood �— Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained j permission from them to ap I for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is a rat n ran s ployees of Mason County access to the above described property and structure for review and inspection. PROOF O CO U TION OF OR JS BY MEANS OF A PROGRESS INSPECTION. X Date: j ner/Owners Re sentati ontractor (indicate which one) I FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group—Type Constr.-1� lr�l Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES