HomeMy WebLinkAboutBLD2024-00545 Addition, Remodel - BLD Inspections - 4/18/2025 615 W.Alder St.Bldg 8,SHELTON,WA 98584
MASON COUNTY SHELTON:360-427-9670,EXT 352
COMMUNITY SERVICES BELFAIR:360-275-4467,EXT 352
Building,Planning,Environmental Health Community Healdi ELMA:360-482-5269,EXT 352
www.co.mason.wa.us
INSPECTION CARD AND CERTIFICATE OF OCCUPANCY**
To schedule an inspection call or visit hftp:/Awww.co.mason.wa.us/community-services/bid-inspection.php
Number BLD2024-00545 Date Issued 06/03/2024 Issued By T 1n. r rw)
Project PRIMARY BEDROOM/BATHROOM ADDITION TO EXISTING CAIN
Site Address 150 E SUBLIMITY LN
Applicant ROSE RICKEY A&PATRICIA T
Contractor NASH HOME BUILDERS LLC
Contractor Phone 1.360.840.4959
Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type
Permit Type ADDITION OR REMODEL- Occupancy
RESIDENTIAL
-APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS.
-DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED.
-THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY.
-ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION.
-OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION.
**THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.**
PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET
Public Works Access/Driveway Other
Health Septic Well
Deptartment
Planning Site Inspection
Department
Fire Marshall Fire Apparatus Access Fire Sprinkler
Auto Fire Alarm Hood and Duct
Other Final
Building Building Official: Community Services Designee
Department
Concrete Setbacks 7 Q 4 Z1( Slab
/ Footing Perimeter Point load Footing
1\ Footing Interior Footing Decks/Porches
Foundation Stem Walls 71 tl SLL Other
Rough-In Groundwork Plumbing Framing •t *2 b ,C
Groundwork Mechanical Plumbing '
Groundwork Gas Pipe Mechanical V-2y
Gas Piping Shear Wall Nailing
Underfloor •Z SNI
Other
Insulation Slab Ceiling
Floor Vaulted Ceiling 06c- ';C-s
Walls L ,( .Z DEL JGS Vapor Barrier
Other
Wallboard Interior Wall Brace Panels Fire Walls
Nailing
Other
Final Building ./ 55i-I
Manufactured Setbacks Setup
Home
Concrete Foot/Runners Final
Other
K
t MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352
� Building,Planning,Fire Marshal
615 W. Alder St. Bldg. 8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: ��A2pZ GAS%
ADDRESS/LOCATION: DSO 9L,4 Jl11& LA/
FINDINGS•
S aht(A44111 e!�? S " Z ��ccs
-�'6014�tiv4f, v`! We,01A a! vG! a �a C100f
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
,Call for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to
Date: 2-4 ❑ Please contact our office regarding possible
Department: M-p structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
INSPECTION RESULTS Pagel
Department of Community Development
MASON COUSERVICES TY
COMMUNITYNITY SE 615 W Alder St,Shelton,WA 98584
°. ^-m-.-, -- (360)427-9670
Application# BLD2024-00857 Appplication DEMO Application# BLD2024-00857
Ty
Parcel# 321275200022 Site Address 360 E Shamrock Dr Shelton,WA 98584
Inspector'
8-5-24 DEC
Drew Car!sun BLD-DEMO FINAL INSPECTION FAIL all int finishes and insulation have been removed
contact E&H to close septic permit
Task Description ;- Status
GENERAL OBSERVATIONS AWAITING
I,,'SPECTIONt
Description Status Status Date
4`
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352
Building,Planning,Fire Marshal
615 W. Alder St. Bldg. 8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTIONANSPECTION REPORT
PERMIT/CASE NUMBER: Z:�/- oOSSy's— _
ADDRESS/LOCATION: 1,50- //�y/� LA/
FINDINGS
wr &.4r&-X PP044 S �s '4 o/t-
Items listed above must be corrected to wain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to r
Date: (��/'Z 4 Please contact our office regarding possible
Department: 13G_P structural damage incurred by recent
Inspector: PmAi2 "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
INSPECTION RESULTS Pagel
MASON COUNTY Department of Community Development
COMMUNITY SERVICES 615 W Alder St,Shelton,WA 98584
(360)427-9670
Application# BLD2024-00545 Application ADDITION OR REMODEL-RESIDENTIAL Application# BLD2024-00545
Parcel# 221231490041 Site Address 150 E SUBLIMITY LN GRAPEVIEW,WA 98546
8-7-24 DEC
see#4 from previous inspection
squash blocks are required to be vertical grain and wide
enough to provide full bearing from studs above
Drew Carlson UNDERFLOOR INSPECTION FAIL 8-5-24 DEC
strap sill plate to pony wall top plate 2 places
continue full depth blocking full length of beam to door
install squash blocks at hold down locations
rim joist STHD not used have Engineer of Record provide a
detail to complete the connection
nail rim joist at 6"o.c.per detail
AWAITING
GENERAL OBSERVATIONS
INSPECTION,],,,,,,__,_
Description Status Status Date
INSPECTION RESULTS Page
MASON COUNTY Department of Community Development
COMMUNITY DEVELOPMENT 615 W Alder St,Shelton,WA 98584
Permit Al—tame Center,Burldine,Pla—mg (360)427-9670 ext.352
Application# BLD2024-00545 Application Type ADDITION OR REMODEL- Owner ROSE RICKEY A&
RESIDENTIAL PATRICIA T
Parcel# 221231490041 Site Address 150 E SUBLIMITY LN GRAPEVIEW,WA
98546
Inspector Inspection Type Date Status Comments
11/15/24 NN
ATHROOM FANB DUCTING NOT YET INSTALLED.PLEASE COMPLETE AND
ENT TO EXTERIOR.
�ICEAK IN PLUMBING SUPPLY LINES IN CRAWL SPACE.SEE BLACK X
Nicole Norris FRAMING INSPECTION 11/15/2024 FAIL /MARKED ON SUPPLY PIPING.
PER DETAILS 6,7,8,AND 9.MECHANICAL CONNECTIONS ARE NEEDED AT
AFTERS(HANDERS AND H1 CLIPS)AND A35S AT BLOCKING.PLEASE
INSTALL PER DETAILS.
ITEMS WILL BE CHECKED AT NEXT INSPECTION.
INSPECTION RESULTS Pagel
MASON COUNTY Department of Community Development
IW' COMMUNITY DEVELOPMENT 615 W Alder St,Shelton,WA 98584
vermrc nssasarxe cencc,aommg,v�annmg (360)427-9670 ext.352
Application# BLD2024-00545 Application Type ADDITION OR REMODEL- Owner ROSE RICKEY A&
RESIDENTIAL PATRICIA T
Parcel# 221231490041 Site Address 150 E SUBLIMITY LN GRAPEVIEW,WA
98546
Inspector Inspection Type Date Status Comments
11/20/24 NN
PER PREVIOUS CORRECTION.ITEM#3 NOT COMPLTE.RAFTER TO RIDGE
CONNECTION SPECIFIES HANGERS,CURRENTLY ONLY A35S INSTALLED.
PLEASE REVIEW WITH FOR FOR CURRENT CONDITION.
11/15/24 NN
Nicole Norris FRAMING INSPECTION 11/20/2024 FAIL 1.BATHROOM FANB DUCTING NOT YET INSTALLED.PLEASE COMPLETE AND
VENT TO EXTERIOR.
2.LEAK IN PLUMBING SUPPLY LINES IN CRAWL SPACE.SEE BLACK X
MARKED ON SUPPLY PIPING.
3.PER DETAILS 6,7,8,AND 9.MECHANICAL CONNECTIONS ARE NEEDED AT
RAFTERS(HANDERS AND H1 CLIPS)AND A35S AT BLOCKING.PLEASE
INSTALL PER DETAILS.
ITEMS WILL BE CHECKED AT NEXT INSPECTION.
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
FADDITION
4-00545 ADDITION OR REMODEL-
RESIDENTIAL
ESCRIPTION: PRIMARY BEDROOM/BATHROOM ISSUED: 06/03/2024
O EXISTING CABIN
ESS: 150 E SUBLIMITY LN GRAPEVIEW EXPIRES: 11/30/2024
PARCEL: 221231490041
APPLICANT: ROSE RICKEY A&PATRICIA T OWNER: ROSE RICKEY A&PATRICIA T
P O BOX 122 P O BOX 122
ROSBURG,WA 98643 ROSBURG,WA 98643
1.253.606.9201
GENERAL CONTRACTOR'S LICENSE: NASH HOME BUILDERS LLC License: NASHHHB791K1
PO BOX 722 Expires: 06/01/2025
GRAPEVIEW,WA 98546
1.360.840.4959
VALUATIONS: FEES: Paid Due
Covered Deck/Carport 64.00 $1,408.00 Change in Tenant- Minor EH $135.00 $0.00
R-3 VB Residential, one- 500.00 $83,040.00 Plan Review
and two-family State Fee-Residential $6.50 $0.00
Uncovered Deck 150.00 $2,250.00 Plumbing Base Fee $25.00 $0.00
Mechanical Base Fee $30.00 $0.00
Mechanical Fees $39.00 $0.00
Technology Surcharge $35.58 $0.00
Plumbing Fees $59.00 $0.00
Building Permit Fee $985.32 $0.00
Planning Review Fee $240.00 $0.00
Plan Check Fee $640.46 $0.00
Total: $86,698.00 Totals : $2,195.86 $0.00
FIXTURES
Qty Mechanical Fixtures C j(t Plumbing Fixtures
1.0000 Dryer Vent(s) 1.0000 Bathroom Sink
1.0000 Spot Vent Fan(s) 1.0000 Number of Clothes Washers
Printed by:Anna Schaffran on:06/03/2024 10:51 AM
Page 1 of 7
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2024-00545
-Qty Mechanical Fixtures (3ty Plumbing Fixtures
1.0000 Ductless Heat Pump 1.0000 Number of Showers
1.0000 Number of Toilets
1.0000 Number of Water Heaters and or Vent
2.0000 Number of Hose Bibs
REQUIRED INSPECTIONS
Setback Inspection Framing Inspection
Footing Inspection Rough- Plumbing Inspection
Foundation Wall-Pre-Pour Inspection Mechanical Inspection
Underfloor Inspection Insulation Inspection
Shearwall Inspection BLD-Final Inspection
CONDITIONS
A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room,or an approved location inside the building. When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component, the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage
results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are
available in or sheets.
" CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
Printed by:Anna Schaffran on:06/03/2024 10:51 AM
Page 2 of 7
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2024-00545
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* Adopted Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
2 Heat pump
3.6 Ductless split system heat pumps with no electric resistance heating in the primary living areas. A ductless heat pump
system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor
air temperature.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather,
garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of
3000 psi (IRC Table R402.2).
* The foundation/footing must be placed on undisturbed,firm-native soil. Proper frost depth, minimum 12 inches, shall be
observed below grade in undisturbed soils.
* A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by
the Mason County Department of Public Works. For any construction which is proposed to be located within 25'of a Mason
County road right of way, it is suggested to contact that office to review future planned work which may affect your project.
For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building
permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled
and approved.
* Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate
building permit and approval prior to construction of the retaining wall.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
contact the Mason County Public Works Department prior to construction at Ext 450
Printed by:Anna Schaffran on:06/03/2024 10:51 AM
Page 3 of 7
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2024-00545
" All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
" Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403,
applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches(38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results(Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
" By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
• All property lines shall be clearly identified at the time of foundation inspection.
" All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
" The use, handling and storage of hazardous materials or flammable and combustible liquids is not allowed without the
approval of the Mason County Fire Marshal.
Printed by:Anna Schaffran on:06/03/2024 10:51 AM
Page 4 of 7
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2024-00545
The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED.
* WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind
speed for Mason County is 85 mph with 110 mph gust factor.
* Before renovating or remodeling activities in pre-1978 residential buildings or child occupied facilities and to ensure your
compliance with applicable Washington lead regulations, contact the WA State Department of Commerce Lead Paint
Program at; (360)586-5323 or email Ibpinfo@commerce.wa.gov. Visit www.commerce.wa.gov/lead for further information.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Code 14.28 and 14.17.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* All changes to"approved"building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
Printed by:Anna Schaffran on:06/03/2024 10:51 AM
Page 5 of 7
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2024-00545
" A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan. Under the requirements of Mason County
Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior
approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose.
* REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit
expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being
taken.
* Prior to inspections, the common line, ordinary high-water mark (OHWM), and the entirety of the building envelope
(including roof eaves, landings, decks, etc.)must be identified and staked. Failure to properly identify and stake will result in
a failed inspection which will require a re-inspection at a later date.
* The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical
report or assessment. All applicable recommendations and specifications shall be applied to the development on this site.
Any deviation requires stamped written approval from the registered design professional responsible for the
report/assessment, and may require special inspection by same. Structures and/or land modifications (grading, cuts, fills,
etc.) required in the geotechnical report/assessment, may require a separate permit. The geotechnical report/assessment
shall remain attached to the approved building plans.
* Setbacks are measured from the furthest projection of the structure.
* Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered.
A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations.
B.)Septic tank(s) requires 5ft setback from all footing/foundations.
C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area.
D.) No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/ Reserve area.
Printed by:Anna Schaffran on:06/03/2024 10:51 AM
Page 6 of 7
Mason County
� --- Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2024-00545
hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By: 14+7)/1 Po �.
Contractor or Authorized Agent: Date: Z�