Loading...
HomeMy WebLinkAboutBLD2025-00173 Roof Solar - BLD Inspections - 4/16/2025 INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2025-00173 PROJECT ADDRESS 141 E ENCHANTMENT HEIGHTS DR UNION, WA 98592 PARCEL# 421242200000 PROJECT DESCRIPTION Install 20 rooftop solar modules on single family home OWNER HATCHERY WOODS LLC ADDRESS 1553 N 38TH ST PHONE 347-694-0857 CONTRACTOR SOUTH SOUND SOLAR INC ADDRESS 4511 LEMON RD NE PHONE 360.352.7869 CONTRACTOR LICENSE SOUTHSS902N7 LENDER INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments BLD-Final Inspection Ib12 P43S M (P >-�V,41 (Soa ZS No L Y Q_�ak- �v�FoS 1�i.�►� ���(o�ZS III ip INSPECTION RESULTS Page MASON COUNTY Department of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584 Permit A�sislance Center,Building,Plann;ng (360) 427-9670 ext. 352 Application# BLD2025-00173 Application Type ROOF MOUNT SOLAR PANEL-RESIDENTIAL Owner HATCHERY WOODS LLC Parcel # 421242200000 Site Address 141 E ENCHANTMENT HEIGHTS DR UNION, WA 98592 Inspector Inspection Type Date Status Comments 4-15-25-JQ Joshua o LNI green tag- please send Photos of electrical green tag when installed in the Quarders BLD-FINAL INSPECTION 04/15/2025 FAIL panel OK to send photo Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2025-00173 ROOF MOUNT SOLAR PANEL- RESIDENTIAL PROJECT DESCRIPTION: INSTALL 20 ROOFTOP SOLAR MODULES ISSUED: 02/17/2025 ON SINGLE FAMILY HOME SITE ADDRESS: 141 E ENCHANTMENT HEIGHTS DR UNION EXPIRES: 08/16/2025 PARCEL: 421242200000 APPLICANT: HATCHERY WOODS LLC OWNER: HATCHERY WOODS LLC 1553 N 38TH ST 1553 N 38TH ST SEATTLE,WA 98103 SEATTLE,WA 98103 347-694-0857 CONTRACTOR: South Sound Solar 4511 Lemon Rd NEOlympia,WA 98506 3603527869 GENERAL CONTRACTOR'S LICENSE: SOUTH SOUND SOLAR INC License: SOUTHSS902N7 4511 LEMON RD NEOLYMPIA,WA 98506 Expires: 08/27/2026 360.352.7869 FEES: Paid Due Solar/PV Base Fee $30.00 $0.00 Final Inspection $97.00 $0.00 State Fee-Residential $6.50 $0.00 Technology Surcharge $1.94 $0.00 Solar/PV Fee $380.00 $0.00 Totals : $515.44 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection CONDITIONS Printed by:Brittany King on:02/18/2025 10:26 AM Page 1 of 3 If Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2025-00173 Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. " The installation of solar(thermal or photovoltaic)energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 4 Ibs per square foot. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two-3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. Printed by:Brittany King on:02/18/2025 10:26 AM Page 2 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2025-00173 * The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: O, A_A,,A� Date: Printed by:Brittany King on:02/18/2025 10:26 AM Page 3 of 3 MASON COUNTY PERMIT NO. W)&Z-00/-�3 DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL ( ) C- VIE 0 D WWW.CO.MASON.WA.US 360 427-9670 Shelton ext.352 V Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext.352 �xsr Shelton,WA 98584 (360)482-5269 Elma ext. 352 {=;� 3 2G25 PLUMBING & MECHANICAL PERMIT APPLICATION 615 W. Alder Street OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: Hatchery Woods LLC NAME: South Sound Solar MAILING ADDRESS: 1553 N 38th St MAILING ADDRESS:4511 Lemon Rd. NE CITY:Seattle STATE: WA ZIP: 98103 CITY: Olympia STATE: WA ZIP: 98506 PHONE: 347.694.0857 CELL:__ PHONE: 360-352-7869 CELL: EMAIL: Marshall.Clement Ct amail.com EMAIL : Victoria a Southsottndsolar.com L&I REG# SOUTHSS902J3 EXP. 07/12/2026 PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER):421242200000 LEGAL DESCRIPTION(,4813nC1T4TCD): NW NW SITE ADDRESS: 141 E Enchantment Heights Dr CITY:Union DIRECTIONS TO SITE ADDRESS: Hwy 101 to East on E Purdy Cutoff Rd, right on E Enchantment Dr left on E Old Hatchery Ln, quick Right on E Enchantment Heights Driv , TYPE OF JOB Property on right NEW X ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS— I'' FLOOR 2ND FLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Tie of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG Natural Gas Ductless Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel _ 1 Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null 8 void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. ✓I � y Signature of Applicant Date x Victoria Blunt on behalf of South Sound Solar Owner/Owners Representative/Contractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING, DEPARTMENT FIRE MARSHAL OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist. All project plans and supporting documentation must be provided on site for the inspector. --------TO BE COMPLETED BY APPLICANT------- © Project Information Property Owner Name: Hatchery Woods LLC Project Address: 141 E Enchantment Heights Dr Parcel# City:Union state. WA ZIP: 98592 Day Phone: Contractor Name South Sound Solar Contractor License#: SOUTHSS902J3 Contractor day phone: 360-352-7869 Describe project: conventional framed built dwelling or garage, Pole structure,steel building,etc. Note: Manufactured/mobile homes require L&I Approval PV system description 8.4kWDC Rooftop mounted PV solar system of 20 Silfab SIL420BG (include manufacturer modules with 10 APSystems DS3-S Microinverters and model#of PV modules and inverters): ©Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that ❑ is code compliant to setbacks and height,or code allows expansion of nonconformity for ca solar modules. [IRC 101.2] 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by EX the local jurisdiction. ❑ 3. Rooftop is made from lightweight material such as a single layer of composition shingles, ® ❑ metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.21 I& ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code,and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended ❑ by WA State. [IRC M2302.2] 7. The PV system is designed for the wind speed of the local area, and will be installed per Ck ❑ the manufacturer's specifications. [IRC M2302.2.1(1)] 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] i( ❑ 9. Total dead load of modules, supports, mountings, raceways and all other appurtenances Ex ❑ weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] 1 Enter total dead load of system (lbs/ft):Click here to enter text. 10. To address uplift, modules are mounted no higher than 18"above the surface of the ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty(50) pounds. 1� ❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for 13d ❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, EX ❑ rodents, and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. ❑ [IRC M2302.2.3] Comments: Click here to enter text. N* If you answered yes to all of the above questions,the project qualifies for the over-the- counter permitting process. © Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: / Date:02/12/2025 Applicant Name(Please Print): Victoria Blunt on behalf of South Sound Solar --------TO BE COMPLETED BY MASON COUNTY STAFF------ Qualifiesfor OTC Building Permit? [--]Yes ❑No Permit Application#: Staff Initials Date: 2 +mom l\ l PI 1320 FT Ebb — — — — — — — _ _ — _ — — — — _ I no' AKAWALE vnn I Fs`S�j \ MAT I "t AREA �� W s.o•w.v, z ..�w.° 1 NI \ \ �,•", I „ m � IL •ir s N% f�����•x I ow. ACCESSIBLE i • `x°'K - - -..`—,s _�`•L I • oww ssserts I NABDAr �K- -'—� I •� � e AREA � /•;nP , E ri moLLcr nroArAnox: En[m wanwc LxroRrAnox: f u.na..xw ♦,.m.xm / .a w ..R.xw>........ SDE PLAN LEGEND �,..., �� +aw.am..,s,wn�..... ® ao.mxix.✓n.wm°.a / i // •/� SRE PLAN A'1.1 a,o.,.. �<..e..,•..ow —____—unms w.m SGUEr-ma - s Marshall Clement ROOF SPECS: 141 Enchantment Heights Dr. SLOPE 8:12 Union,WA 98592 TYPE SSM 347-694-0857 Array Mounting:SNR marshall.clement@gmail.com S-5!N OR S-5!S Sales: Bruce Hargrave ARRAY FP=420 LOAD=<4 psf DATE:11 Oct.2024 DRAWN BY:JC 1-LINE DIAGRAM VERSION 1.1 411.75" SOUTH SOUND SOLAR UTILITY:MCPUD 1 360.352.7869 CCB#SOUTHSS902N7 AHJ:LNI THURSTON CO n v SYSTEM SPECS 20)SILFAB 410 BG MODULES= 8.4kW(S.T.C.) MAX POWER:420 WATTS Vmp=38.51 VDC-Imp=10.91 A 4' SPACING Voc=46.36VDC-Isc=11.4A 10)APSYSTEMS DS3-S MICROINVERTERS MAX OUTPUT POWER=640VA=633.6W MAX OUTPUT CURRENT=2.66A @ 240 VAC EACH MAX UNITS PER 20A BRANCH=5 _—_(2) #8THHN _____ ______ ____ (2) 10/2NMB MAX UNITS PER 20A BRANCH=5 W/ #10 EG W/GROUND IN 3/4" PVC I � TOTAL MAX OUTPUT CURRENT=26.6A I I DERATED=33.25A,40A OCPD I � I UTILITY LOCATED INTERIOR I SERVICE GARAGE 1 I 240VAC MAIN PANEL I DISCONNECT/RSD COMBINER PANEL 200A BUS I 2P 60A,UNFUSED LOCKABLE 2P 60A 3R MOUNTING SPECS BLACK 240VAC 2P KNIFE OPERATOR PV Module(SIL-420 BG) i F—�10 SNR RAILS/168"ea 1 2P 40A © 8 SNR SPLICES Dimensions: LINE 2P 200A 73.4"L x 40.5"W MCs 40 L FEET ATTACHMENTS Long Edge Primary Mounting NET zP zoA u40 SNR RAIL ATTACHMENTS Zone: METER 4 SNR GROUND LUGS 10.1"-14.0" 2P 20A 2P 40A 8 SNR END CLAMPS Long Edge Secondary Mounting LOAD Zone: 36 SNR MID CLAMPS 5 2"-10 1" LOCATED EXTERIOR 1 NEAR NET METER 10 SNR MICRO HW Short Edge Mounting Zone: 40 S-51N OR S-51S CLAMPS 7.9"-9.8" CLEMENT 2024 MICRO INVERTER MAP APsystems Leading the Industry in • ALTE N ERGY POWER Solar Microinverter Technology DS3 Series The most powerful Dual Microinverter One microinvertermodules Max output power reaching 640VA, 768VA 880VA Two independent NEC 2020 690.12 Rapid Shutdown Compliant Encrypted Wireless ZigBee Communication Phase Monitored and Phase Balanced PRODUCT FEATURES APsystems'3''generation of dual-module microinverters,the DS3 product family represents the culmination of years of power conversion expertise and innovation in high-efficiency,high-density power conversion to maximize the peak performance of today's high-capacity PV modules. The DS3 series reaches unprecedented levels of power output.It features 2 input channels,each with independent MPPT, and encrypted wireless ZigBee communication. An innovative and compact design makes the product lighter while maximizing power production, and silicone-encapsulated components reduce stress on electronics, facilitate thermal dissipation, and enhance weatherproofing. Reliability is significantly increased thanks to 20% fewer components than previous generations.A 24/7 energy access through apps or web based portal facilitate remote diagnosis and maintenance. The DS3 series is grid-interactive and fully compliant with CA Rule 21 requirements. With an excellent performance and high converstion efficiency,a unique integration with less components, the APsystems DS3 series is a gamechanger for residential and commercial solar. WIRING SCHEMATIC 71 2024/02/22 Rev2.0 w Model DS3-S DS3-L DS3 Region USA/Canada Input Data (DC) Recommended PV Module Power(STC) Range 25OWp-48OWp+ 265Wp-57OWp+ 30OWp-66OWp+ Peak Power Tracking Voltage 28V-45V Operating Voltage Range 26V-60V Maximum Input Voltage 60V Maximum Input Current 16A x 2 18A x 2 20A x 2 Maximum input short circuit current 20A per input 22.5A per input 25A per input Output Data (AC) Maximum Continuous Output Power 640VA 768VA 880VA Nominal Output Voltage/Range"" 240V/211V-264V Nominal Output Current 2.66A 3.2A 3.7A Maximum Output Fault Current(ac)And Duration 5.691Apk,26.75ms of duration; 3.307Arms Nominal Output Frequency/Ranget'l 60Hz/58.8Hz-61.2Hz(HECO:57Hz-63Hz) Power Factor(Default/Adjustable) 0,99/0.8 leading_0.8 lagging Maximum Units per 12AWG Branch(" 6(20A breaker) 5(20A breaker) 4(20A breaker) Maximum Units per 10AWG Branch(2) 9(30A breaker) 7(30A breaker) 6(30A breaker) Efficiency Peak Efficiency 97.3% CEC Efficiency 97% Nominal MPPT Efficiency 99.5% Night Power Consumption 20mW Mechanical Data Operating Ambient Temperature Range(3) -40°F to+149°F(-40°C to+65°C) Storage Temperature Range -40°F to+185°F(-40°C to+85°C) Dimensions(W x H x D) 10.3" x 8.6" x 1.6" 10.3" x 8.6" x 1.7" (263mm x 218mm x 41.2mm) (263mm x 218mm x 42.5mm) Weight 5.7lbs(2.7kg) 6.8lbs(3.lkg) DC Connector Type Staubli MC4 PV-ADBP4-S2&ADSP4-S2 Cooling Natural Convection- No Fans Enclosure Environmental Rating Type 6 Features Communication (Inverter To ECU)/" Encrypted ZigBee Isolation Design High Frequency Transformers,Galvanically Isolated Energy Management Energy Management Analysis(EMA)system Warranty`_ 10 Years Standard;25 Years Optional Compliance Safety and EMC Compliance UL1741;CSA C22.2 No.107.1-16;UL1741SA; UL1741SB; IEEE1547; Rule 21; SRD-V2.0; FCC Part15; ICES-003; NEC2014&NEC2017&NEC2020 Section 690.11 DC Arc-Fault circuit Protection; NEC2014&NEC2017&NEC2020 Section 690.12 Rapid Shutdown of PV systems on Buildings (I)Nominal voltage/frequency range can be extended beyond nominal if required by the utility. c All Rights Reserved (2)Limits may vary.Refer to local requirements to define the number of microinverters per Specifications subject to change without notice please ensure you are branch in your area. (3)The inverter may enter to power de-grade mode under poor ventilation and heat dissipation using the most recent update found at web:usa.APsystems.com installation environment. (4)Recommend no more than 80 inverters register to one ECU for stable communication. (5)To be eligible for the warranty,APsystems microinverters need to be monitored via the EMA portal.Please refer to our warranty T&Cs available on usaAPsystems.com. Meets the standard co ® requirements for Distributed APsystems Energy Resources(UL 1741) o and identified with the CSA 8627 N. Mopac Expy, Suite 150,Austin,TX 78759 C US Listed Mark apsystems.com S=510 The Right Way"" to attach almost anything to metal roofs! The Right Way Installation Instructions o 4A'0 Attention!This document is a guide only.This product may not be suitable for every application.The user is responsible for all necessary applications engineering and design,Please scan the QR code to the right for additional information,warnings and disclaimers regarding product use. ❑� titi You can also view load test results at www.s-5.com where applicable,or contact your S-5!distributor for more information. These instructions are for use by those experienced in the trade Always follow appropriate safety precautions and use appropriate tools 1 What's Included in Your Box S-5-N Based on 1 Part S-5-N Mini Based on 1 Part • 2-3/8 x.90"Setscrews • 1-3/8 x.90"Setscrew (10 mm x 23 mm) (10 mm x 23 mm) • 1-M8x16mmHex / • 1-NInsert .� / Flange Bolt Minor Box Qty: 50* • 1-N Insert Master Box Qty:200* Minor Box Qty:30* Master Box Qty: 120* *Broken-box quantities may vary Note: For the S-5-N Mini, in all applications other than a PVKIT,you will need to purchase a Hex Flange top bolt separately. • What You'll Need for Installation 1 Screw Gun T30Torx Bit Tip (provided) Dial-Calibrated Torque Wrench (For accurate tension values,do NOT use a clicking torque wrench; inquire with S-5! for proper tool sourcing) How to Install S-5-N and S-5-N Mini 1 1. Load the setscrew(s) into the clamp. (Fig 1) O O �� S-5-NT"" Installation Instructions 2. Position clamp and insert at desired location along the seam as shown. 2 (Fig 2) NOTE:On wider panel profiles, it may be necessary to place the clamp �/� lr • onto the seam first and then slide the insert into it.Seams that exceed maximum allowance of 0.82"at the widest part of the seam may require hand crimping to facilitate clamp fit,(Fig 2a) 3. The clamp should be over the seam and insert as shown.(Fig 3) Make sure the toe of the clamp engages beneath the fold of the seam as 2a shown. (Fig 3a) � ' Slide insert into 4. Tighten the setscrew(s) using a screw gun* and the included bit tip clamp (Fig 4).When relying on published load values, setscrew tension should be verified periodically using a dial-indicating calibrated torque wrench to ensure the tool is consistently achieving the recommended torque range (Table 1), When installing the S-5-N clamp:Setscrews should be 3 3a alternately tensioned as shown in Fig 4a until both setscrews have achieved recommended torque. When installing the S-5-N Mini clamp:The seam material will compress evenly during the first tightening. S.Attach your ancillary and tighten the bolt. For critical attachment / applications, reference Table 1 for the appropriate torque, 4 O Table 1 Inch Pounds Foot Pounds Nm Setscrewon 160-180 13-15 13-20 4a ' 22ga(0.8 mm)steel Setscrew on ��• 24ga(0.6 mm) 130-150 11-12.5 15-17 • / / steel and all other materials #2 M8 Hex Flange bolt 160 13 18 #1 i i i Once installed correctly,the mechanical interlock is established and these clamps require no maintenance or torque re-inspection for the life of the roof, NOTE:Any 5.51 warranty and/or cakuiation maybe void it hardware is used that was not furnished by 5-51 directly or through one of their licensed distributors or any assembly that has not been tested by 5-51 S-51'Warning!Please use this product responsibly! products..protected h1_11pk u.S.and form patents.For published data regarding holding strength,wtenbtoque,patents,and trademarks,Nflt the S31 weDfte at www.i5.com. ccpytlgM 2022,Meal R=#mnwatbm,Ud S-51 prodwis re patent pnAticled.S-5!aglirmhdy pmtacb Its pMMs,trade rrak5 and coWW tc P rot ra Br acket-V 1.0-1022 ELITE S1 LFAB • �• S O L A R NOT JUST ANOTHER SOLAR PANEL . Back-contact technology with an innovative conductive backsheet and integrated cell 2023 design delivers the highest performance, PERFORMAHCL durability and beautiful aesthetics. Manufactured exclusively in the United States. ELECTRICAL SPECIFICATIONS 420 Test Conditions STC NOCT Module Power(Pmax) Wp 420 313 _.-- ----____ --- Maximum power voltage(Vpmax) V 3gS1 - 35.89 Maximum power current(Ipmax) A 10.91 8.73 Open circuit voltage(Vill V 46.36 43.45 Short circuit current(Isc) P 11.4 9.18 Module efficiency 21.9% 20.4% Maximum system voltage(VDC) 'v 1000 Series fuse rating --- - A 20 Power Tolerance ivp 0 to+10 Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25"C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by 35%and power by 0 to+low. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 20.8_+0.2 45.8±0.4 Ibs Dimensions(H x L x.D) 1864 mm x 1029 mm x 35 mm 73.4 in x40.5 in x 1.4 in Maximum surface load(wind/snow)` SM Pa rear load/5400 Pa front load 112.8 lb/R'rear load/112.8lb/ft'front load Hail impact resistance a 25 mm at 83 km/h a 1 in at 51.6 mph Cells 66high-efficiency mono-PERCMWicSicells 66 high-efficiency mono-PERCMWTc-Si cells 166 x 166 mm 6.53 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, anti-reflective coating anti-reflective coating Cables and connectors(referto installation manual) 1200 mm a 5.7 mm,MC4from Staubli 47.2 in,a 0.22(12AWG),MC4 from Staubli ___.. .._.. ------ --. ....._...._._._-... -------- Backsheet Multi layer,integrated insulation film and electrically conductive backs heet,superior hydrolysis and UV resistance,fluorine- free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP67 rated .TEMPERATURE RATINGS WARRANTIES Temperature Coeffiee-tls� 7-0.2?9 .046%/"C Module product workmanship warranty 25 years** Temperature CoefficientVoc %/'C Linear power performance guarantee 30years Temperature Coefficient Pmax -0.377%/"C >_98%end 1st yr NOCT2"C 43.5"C >_94.7%end 12th yr __------t ) ----- -- --.._...-------- >90.8%end 25th yr Operating temperature t -40/+85•C >_89.3%end 30thyr CERTIFICATIONS SHIPPING SPECS UL61215-1:2017Ed.1,UL61215-2:2017Ed.1,UL61730-120A7Ed.1,UL61730.2:2017Ed.1,, Modules Per Pallet: 27 or 27(California) Product CSAC222861730-12019Ed.2,CSAC22.21161730.2:2019Ed.2,IEC61215-1:2016Ed.11EC _. 61215.2:2016Ed.1 IEC 61730-1:2016Ed.2,IEC61730.2:2016Ed.2,IEC61701:2020(Salt Mist Pallets Per Truck 31or30(California) Corrosion),IEC 62716 2013(Ammonia Corrosion),CEC Listing,UL Fire Rating:Type 1 ----_. _._._-- --------------_._. ---y Factory IS09001:2015 Modules Per Truck 837 or 810(California) ' A Warning.Read the Safety and Installation Manualfor mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolaccom. PAN files generated from 3rd party performance data are available fordownload at:sllfabsolar.com/downloads. L 73.4"[18fi4mm] J ET f 13.1"[332mm] 47.2"[1200mm] 13.1"[332mm] ',Mounting Hole(x4) O.s" SIVAS SOLAR INC. [12mm] 1770 Port Drive Burlington WA 98233 USA 47.25" E _ T+1360.569.4733 [1200mm] " E E E E info@silfabsolar.com G ' Cable Length C m rE �E N SILFABSOLAR.COM 7149 Logistics Lane 35mmNx,. Fort Mill SC 29715 USA 1.4" E a `�' g T+1839.400.4338 2 a 240 Courtneypark Drive East w 6t c Mississauga ON LST 2S5 Canada 'o T+1905.255.2501 3 0'08" ] � F+1905.696.0267 Smm[1. � rainage Hole(x8) F Silfab-SIL-420-BG-20231221 No reproduction of any kind is allowed without permission.Data and information is subjectto 2"[60mm) 8"[200mm] modificationswithout notim.O Silfab Solar inc., 2022.silfab Solar•is a registered trademark of Silfab Solar Inc. DESCRIPTION: DRAWN BY: SNAPNRACK, UR-40 RAIL mwatkins SnapNvack- I REVISION: Solar Mounting Solutions PART NUMBER(S): 232-02449, 232-02450, 232-02451, 232-02536, 595 MARKET STREEE(415) W-6900 SA F415)58 CO CA 94105 USA PHONE(115)58DE900•FAX(4/5(580-6902 232-02537, 232-02538 HE INFORIMTION IN THIS DMYANO IS CONFIDENTIAL AND PROPRIETARY.ANY REPRODUCTION.DISCLOSURE.OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SWTH LLC. UR-40 RAIL PROPERTIES SKU RAIL LENGTH (X) FINISH 232-02449 168" MILL 232-02450 168" SILVER 232-02451 168" BLACK 232-02536 172" MILL 232-02537 172" SILVER 232-02538 172" BLACK 1.500 .750 .832 SECTION PROPERTIES 1.624 A 0.357 in2 Ixx 0.125 in4 CENTROID Iyy 0.132 in4 Sx (TOP) 0.150 10 .792 Sx (BOT) 0.158 in3 Sy (LEFT) 0.175 10 Sy (RIGHT) 0.175 in3 ALL DIMENSIONS IN INCHES MATERIALS: 6000 SERIES ALUMINUM OPTIONS: DESIGN LOAD (LBS): N/A SILVER/ BLACK ANODIZED ULTIMATE LOAD (LBS): N/A MILL FINISH TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 144 CERTIFICATION: UL 2703, FILE E359313 BOXES OF 8 WEIGHT (LBS): 5.85 - 5.99