HomeMy WebLinkAboutBLD22790 Addition/Alteration - BLD Permit / Conditions - 9/26/1988 PERMIT
NULL & VOID BY EXPIRATION
stDAMEnes��_�g BY
Setback: Mechanical :
Special Interior:
Conditions: FINAL:
Mobile Home. —
Smoke Detector:
Remarks:
Footing: p 4 V-e,� ov
Setback: c�
Foundation 4 O/!//1/Et.� D4DDiIlon/
Walls: C.XlJ CAl.3ly �R7`Si�/l
Fr aming:Q�iS��/
Fireplace:
Wood Stove:
TYPE ADDITION/ALTERATION
Permit No. 22790 No. Floors Sq Ftg 1580
Owner WATSON, James R Tel 778-0208 Date 9-26-88
Address 1-815 G�er�- amen�� Chu ct�, ZIP—
Contractor None i3i hez/o/9
Address Zip
Legal Description Haven Lake Lots 136 & 137
Direction to project site ATTACHED
Plumbing X Mechanical X Sewer Wood St ve K
Fireplace __ Deck 616 Garage Carport � LJ/
Basement Loft Other
BUILDING PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584
427-9670 DATE ISSUED '')����-��
PERMIT NO.S�'"'-'� 7 7 t/
OWNER i
NAME MAILADDRESS CITY BSTATE ZIP PHONE
i0(5Cr-l¢vt St. oga5 . 310. R;JZO 7'7�
DIRECTIONS
TO JOB SITE FFaP,4
� �" _
Ccl Ctl,r St�NertC+ ovcV8, a�f J� , av-k . Rt` h-t' Tov�vt r4 -t- (! � Vro
`a �Cr f(DLf Lip fo Noucvir/akQ . LaF-too t4avc" Wad +o Phododeti6v-on g(vd , foN,FN U
PARCEL F3 LEGAL - _ -______.- . ..
NUMBER a 330 5-0 06t37 DESCR. _ M
NAME MAIL ADDRESS ^ I &STU-Er)I C z�JAG' LICENSE NO. ZIP PHONE
CONTRACTOR N 4 1 -
USE OF O( tt
BUILDING 1'\�54d 4-Lcz,
CLASS
WORK O✓ NEW ADDITION ALTERATION V x REPAIR MOVE REMOVE
DESCRIBE
WORK Mov,&d gxt Abi'v► o v► ew loc-cL+ v, , (LrErcx_
/,Z 06 S , -P f +"l(oc)Y^ 5p¢-e e_ , P; i t'vt -�Q v►d dl t t o ti v vl d�v- s c a V-4.+d,
(7- r 44 It °� ,�i�%r rfn�'u.►fa/ 3��� 9� .7.�"33y
BEDROOMS DECKS 3 CARPORT 1 NOTICE
SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR
BATHROOMS TOTALSQ.FT. GARAGE CONDITIONING.
NO.OF STORIES -2- BASEMENT ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT
TOTAL SQ.FT. I S b Z. FIREPLACE COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANYTIME AFTER WORK IS COMMENCED.
PERMANENT y SHORELINE _
SEASONAL i ",1 (L iq V
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF
REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE
REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN
IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING
OBTAINMIG APPROVAL FROM THE BUILDIN DEPARTMENT. t APPROVAL FROM THE BUILDING DEPARTMENT.
O E ��UE o X BY_ DATE
FOR OFFICE USE ONLY
DEPARTMENT YESPPROVEDJO DEPARTMENT YESPPROVEDIO BUILDING VALUATION
HEALTH PUBLIC WORKS FEE
PLANNING Y FIRE BUILDING PERMIT
D.O.T. BUILDING PLAN CHECK
SPECIAL CONDITIONS BUILDINGGROUP ,'3 PRE-INSPECTION
,6 'r-r a m SHORELINE
WOODSTOVE
PLUMBING ✓
0 0. Or-01A X.36,dm>93 MECHANICAL
6-/e`0 x -5 d2L' _ STATE BUILDING FEE
STATE SURCHARGE
APPLICATION ACCEPTED BY PLAN CHECK BY APPROVED FOR ISSUANCE PERMIT VALIDATION
BYall< a� CASH CK MO TOTAL
PLUMBING & MECHANICAL PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584
427-9670 DATE ISSUED
PERMIT NO.
NAME MAILADDRESS CITY&STATE ZIP PHONE
OWNERS 6-1 1, uilk� - c�
DIRECTIONS
TO JOB SITE
LEGAL
DESCR.
CONTRACTOR NAME MAILADDRESS CITY&STATE LICENSE NO. ZIP PHONE
USE OF
BUILDING
PLUMBING FIXTURES MECHANICAL FIXTURES
NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE
`j WATER CLOSETS FORCED-AIR/GRAVITY TYPE FURNACE 6.00
3 BASINS • ' FLOOR/SUSPENDED FURNACE 6.00
�} BATHTUBS BOILER/COMPRESSOR 6.00
Z SHOWERS L, REPAIR/ALTERATION 6.00
WATER HEATERS y REFRIGERATION COMPRESSOR SYSTEM 6.00
AUTO.WASHER - AIR HANDLING UNITS 7.50
SINKS HEAT-PUMPS 6.00
FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET
DRINKING FOUNTAINS f VENT.FAN SYS.3.00 PER UNIT
LAUNDRYTRAYS WOOD STOVES 10
CONNECT TO CITY SEWER WOOD FURNACE 5.00
DISHWASHER
DISPOSAL
URINALS
PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00
TOTAL �r TOTAL
SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS
SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED.
OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED
THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE
COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL
WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE
WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT.
X OWNER DATE _ X BY__ DATE
FOR OFFICE USE ONLY
APPLICATION ACCEPTED BY PLA
NS CHECK BY BUIIL�DING GROUP APPROVED FOR ISSUANCE PERMIT VALIDATION
'�3 BYA � g CASH CK MO
DATE: SEPTEMBER 21 , 1988
NAME: Mr. & Mrs. Jim Watson
ADDRESS N.E. 131 Rhododendron Blvd.
Tahuya , Washington
PROJECT ADDRESS: SAME
HEAT LOSS CALCULATIONS
MAIN FLOOR AREA 1371 S.F.
SECOND FLOOR/LOFT AREA 300 S.F.
BASEMENT FLOOR AREA( if applicable ) 0 S.F.
MAIN FLOOR VOLUME 10940 C.F.
SECOND FLOOR VOLUME 2400 C.F.
BASEMENT FLOOR VOLUME 0 C.F.
WALL AREAS: MAIN FLOOR 1139 S.F.
SECOND FLOOR 466 S.F.
BASEMENT 0 S.F.
WINDOW AREAS: MAIN FLOOR 254 S.F.
SECOND FLOOR 225 S.F.
BASEMENT 0 S.F.
ROOF AREAS 1371 S.F.
DOOR AREAS 100 S.F.
INFILTRATION(Number of air changes per hour ) 1 .5 A.C.HR
INSIDE TEMPERATURE 70 F
OUTSIDE AIR TEMPERATURE 2.4 F
PART2 HEAT LOSS CALCULATIONS
1 HEAT LOSS THROUGH AIR LEAKS
Q1 = 0.018(con5t ) x V(volume ) x TD( temp diff ) x ACH(air changes )
0.018 x 13340 x 46 x 1 .5
16568. BTUS/HR
2 HEAT LOSS THROUGH WALLS
WALL COMPONENTS - MAIN FLOOR
Qc = A X TO / R
Inside air film 0.68
1139 X 46 / 22.0 gypsum board 0.45
insulation 19
2378.3 BTUS/HR exterior sheathing 0.68
exterior siding 1 .05
outside air film 0. 17
TOTAL 22.03
WALL COMPONENTS - SECOND FLOOR
Qc A X TO / R
Inside air film 0.68
468 X 46 / 22.0 gypsum board 0.45
insulation 19
977.21 BTUS/HR exterior sheathing 0.68
exterior siding 1 .05
outside air film 0. 17
TOTAL 22.03
WALL COMPONENTS - BASEMENT FLOOR
Qc = A X TO / R
Inside air film 0.68
= 0 X 46 ! 14.0 gypsum board 0.45
insulation 11
0 BTUS/HR exterior sheathing 0.68
exterior siding 1 .05
outside air film 0. 17
TOTAL 14.03
3 HEAT LOSS THROUGH ROOF/CEILING
ROOF/CEILING COMPONENTS
Qc = A X TO / R
Inside air film 0.68
1371 X 46 / 32.4 gypsum board 0.45
insulation 30
1945.2 BTUS/HR exterior sheathing 0.68
roofing 0.44
outside air film 0. 17
TOTAL 32.42
4 HEAT LOSS THROUGH FLOORS
FLOOR COMPONENTS
Qc = A X TO / R
Inside air film 0.68
1371 X 46 / 20.6 floor covering 0. 1
underlayment 0.68
= 3057.0 BTUS/HR insulation 19
outside air film 0. 17
TOTAL 20.63
5 HEAT LOSS THROUGH GLASS
GLASS COMPONENTS
Qc = A X TO / R
Insulated glass 1 .82
= 479 X 46 / 1 .82 ( double )
Class 60 with
12106. BTUS/HR electric
resistance
TOTAL 1 .82
6 HEAT LOSS THROUGH EXTERIOR DOORS
DOOR COMPONENTS
Qc = A X TO / R
solid core doors 2.78
= 100 X 46 / 2.78
1654.6 BTUS/HR
TOTAL 2.78
TOTAL ESTIMATED HEAT LOSS 38687.34 BTUS/HR