Site Inspection
November 26, 2008
RICHARD BECKMAN TO BE KEPT IN THE
PO BOX Y PARCEL FILE
SHELTON WA 98584
Case No.: SP12008-00171 PAI 2232-1 S 600c.o
Parcel No.: 223297500090
Project Description: Site review for new residence and outbuildings.
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI)was performed on your property. Below
you will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands
must be included in your specific proposal; these setbacks are included as part of the comments
listed below.
This information is based on County and State regulations as they exist to date. These
regulations may change and may affect the requirements for development of the subject property.
Please contact me at(360)427-9670, ext. 365 if you have questions.
Sincerely,
&"("
Allan Borden
Land Use Planner
Mason County Planning Department
11/26/2008 Page 1 of 4 SP12008-00171
Site Inspection
11/26/2008 Case No.: SP12008-00171
Comments:
Pre-inspection for Richard Beckman or Vic Dell on Oct. 23, 2008:
Lot Description: Property is at the south end of Ranch Rd. as tract
9 (5.20 ac.) in an old plat. The 1,200 + foot long property is
oriented east to west and located uphill from the Tahuya River.
The site was partly cleared with the potential building site and
septic tank and drainfield in the west central area. In the central
area at 450 east of the road, there is a 25 to 35 percent slope
down to a more level area closer to the river. The applicant
wishes to place a residence in the west area and is seeking
whether geologic studies and other setbacks are needed for
proposed development. These findings state regulations in effect
at the time of inspection, unless noted otherwise.
Development Regulations standards:
_Y_ The site is in Inholding Lands zone. Standard building
setbacks are 25-foot front yard setback, and 20-foot side property
line and rear yard setbacks. These setbacks are measured from
structures above grade such as roof overhangs, stairs, balconies,
decks, heat pumps, storage buildings, and fuel tanks.
Resource Ordinance Standards:
_Y_ Slope or Landslide hazards: Slopes over 15 percent
adjacent to or within 300 feet of a proposed project were
observed. The applicant shall have a qualified geologist or
engineering geologist visit the subject parcel and prepare a site
analysis to determine whether a geologic special report is needed
during development review.
_Y_ Slope or Landslide hazards: If the geologist confirms the
need for a special report when slopes are between 15 and 40
percent, a Geologic Assessment would be needed to address
slope stability, site conditions, and the other requirements of the
enclosed landslide hazard chapter 17.01.100 section E. 4. as
required by the Mason County Resource Ordinance. The report
must include all Resource Ordinance requirements and a
submittal checklist noting where these requirements are found in
the study document.
_Y_ Slope or Landslide hazards: The prepared special report
shall be specific to proposed site development on the subject
parcels by addressing clearing, grading, driveway and building
location, retaining walls, and stormwater control. This special
report would be submitted and evaluated at the time of building
11/26/2008 Page 2 of 4 SP12008-00171
Site Inspection
11/26/2008 Case No.: SP12008-00171
permit submittal. The study shall address the presence of the
septic system on site stability conditions.
_N_ Wetland critical area: Planning staff confirmed that the
parcel does not contain certain wetlands, which are regulated
under Mason County's Wetlands chapter 17.01.070 of the Mason
County Resource Ordinance.
_N_ Shoreline setbacks: The shoreline designation for the area
is Conservancy Environment per the Mason County Shoreline
Master Program and setbacks would be determined by the Mason
County Resource Ordinance. The proposed development is
greater than 200 feet from the shoreline management area
covered by either critical area standards.
_Y_ Stream setbacks: The setbacks from the Tahuya River
would be determined by the Mason County Resource Ordinance.
The stream setback for a type S stream is composed of a
150-foot vegetation buffer plus a 15-foot building setback closest
to the roof projection of a proposed structure. Any portion of the
new structure, including decks, balconies, and rooflines, must be
behind this setback line. The 15 feet toward the stream is an area
that may be used for lawns, patios or landscaping (development
Y p p 9 ( P
at grade level). From that point toward the stream is considered
to be a required vegetated buffer and is regulated by the Mason
County Resource Ordinance Fish and Wildlife Habitat
Conservation Areas Chapter. Within this chapter are those
p P
activities listed that can be done both with and without a Mason
Environmental Permit.
Only a 450-foot depth of the parcel has already been cleared of
some of the trees, and the remaining 750-foot depth of the parcel
is left intact. Past land activities were long enough ago for some
of the vegetation to grow back. The general location of proposed
development (the home, outbuildings, and septic system) would
be in this area. The presence of the slope in the central west area
creates some constraints to site development. Working with the
locations of the past home and septic areas and the
recommendations of the geologic study, you should be able to
propose the placement of a residence to meet the structure
setbacks from the property lines.
You would need to confirm with the Health Department what their
septic system standards are to make sure about the adequacy of
supplying a septic system and drainfield area(s).
General process: Future site development must include a site
11/26/2008 Page 3 of 4 SP12008-00171
1
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes,wetlands, etc.)
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEQUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
lr
s—
D
We ( laic
Departmental Review
(For Office Use Only)
Planning Department Findings:
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes, wetlands, etc.)
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEOUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
1
I
�)Ci (
Departmental Review
(For Office Use Only)
Planning Department Findings:
\223297500060 y 223297500190
\ '�-
223297500180
223297500050 �ryo 1 00
N
223297500170
t
! 240
2232975001613
LN �o
NE LITTLEJP�\
223297500040 223297500150
223290060000
223297500140 C.
:. .. • N
P 2 223297500130
223297500030 2A0 223294000000
/ 1 223297500120
T23NR2W 280
223293490020 223297500110 r,
223293490021 291' , 223297500100
� Zg�
1
223293490011 223293490012
Ilk223297500090 �\
\O
223293490013 0
223293490014 •''
223297500080 'P '••'
o •
o
280
200
T23 R2 223320060000 2p0
32 '
223320060010 0� 0 200-
280 ti
260
223320060000
N
1 inch = 300 feet
W E
1 inch = 0.06 miles
S
f
,
s
P � «
.l
ar
00
CA
fj
°
28 ` r
'f23NR .r 2
p F
a
20p 3
NF
Hq L �y
?ao
4
N
1 inch = 300 feet
W E
1 inch = 0.06 miles
S