HomeMy WebLinkAboutFIR2017-00027 AFA - FIR Permit / Conditions - 11/20/2017 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 ors°N cOb�Tp Phone: (360)427-9670, ext. 352 �y Mason County 615 W Alder Street Shelton, WA 98584 FIRE PROTECTION PERMIT FIR2017-00027 APPLICANT: 111 RANCH DRIVE LLC RECEIVED: 9/5/2017 CONTRACTOR: LICENSE: EXP: ISSUED: 11/20/2017 SITE ADDRESS: 111 NE RANCH DR TAHUYA EXPIRES: 5/20/2018 PARCEL NUMBER: 223293490013 LEGAL DESCRIPTION: LOT C OF SP#1134 PTN TR 1 OF S 8/150 PROJECT DESCRIPTION: AUTOMATIC FIRE ALARM SYSTEM GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: Dry Chemical?: Pressure Switches:: Smoke Detectors: Duct Detectors: Zones: Heat Detectors: Wet Chemical?: Sprinkler?: Standpipe?: SQUARE FOOTAGE FEES Monitoring Company: AVANTGUARD First Floor: Type Amount Due Amount Paid Monitoring Phone No.:(844)456-1999 Second Floor: Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Plan Chec $136.01 $136.01 Auto. Fire Alarm Permit Fe, $209.25 $209.25 Total: $345.26 $345.26 FIR2017-00027 Please refer to the following pages for conditions of this permit. Page 1 of 6 CASE NOTES FIR2017-00027 CONDITIONS FOR FIR2017-00027 FIR2017-00027 Please refer to the following pages for conditions of this permit. Page 2 of 6 1.) Alarm acceptance form attached. Please ensure that everything is completed prior to calling for final inspection. X Ensure that keys for alarm system are provided for KNOX Box. X Install Per NFPA 72. X Approved plans must be onsite at all times and kept at the Fire Alarm Panel. X Identify FACP circuit breaker in FACP and provide for FACP A/C lock out. X Label batteries with month and date placed in-service X Provide all staff and equipment to conduct acceptance testing. X Provide EOL access during acceptance test. X All plans are subject to field inspections, inspector revisions may be made to obtain compliance. X Exterior horn/strobe to face roadway. X Final Fire Marshal inspection will be required prior to Building Department Final. X Provide Washington State Fire Marshals Acceptance forms upon Final. X FIR2017-00027 Please refer to the following pages for conditions of this permit. Page 3 of 6 Provide NFPA 72 acceptance paperwork at time of final. X Plan approval does not relieve the designer/contractor from complying with all applicable codes and requirements as adopted by Mason County and the State of Washington, not does it abrogate the requirements of the requirements of other authorities having jurisdiction. X OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signature Date OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) FIR2017-00027 Please refer to the following pages for conditions of this permit. Page 4 of 6 o coU�TA MASON COUNTY N Department of Community Development FIRE PROTECTION SYSTEMS INSPECTION CARD* Mason County, 615 W Alder Street, Shelton, WA 98584 } General Questions: (360) 427-9670 ext 352 Inspection Requests: (360) 427-7262 1854 Permit Number FIR2017-00027 Date 11/20/2017 Issued By Project AUTOMATIC FIRE ALARM SYSTEM Site Address 111 NE RANCH DR TAHUYA Applicant 111 RANCH DRIVE LLC Contractor License Number Con. Phone Expiration Date Primary Code 2012 IFC Wet Chem Sprinkler Use COMM Dry Chem Standpipe Hod and Duct -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS -*THIS STRUCTURE MAY NOT BE USED FOR OCCUPANCY UNTIL ALL REQUIRED FINAL INSPECTIONS ARE APPROVED -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED -POST THIS CARD IN A CONSPICUOUS LCOATION ON THE FRONT OF THE PREMISES CONVENIENT FOR MAKING REQUIRED ENTRIES. -ALL PERMITS EXPIRE 180 DAYS AFTER PERMIT ISSUANCE OR 180 DAYS AFTER LAST INSPECTION ACTIVITY IS PERFORMED. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL REQUIRED INSPECTIONS PRIOR TO THE FINAL OCCUPANCY INSPECTIONS -PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET. Public Works Access/Driveway Other Health Dept Septic Well Planning Dept Site Inspection Fire Marshal Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Dept Building Official: Community Development Designee Concrete Setbacks Slab Footing Perimeter Ret. Wall/ Bulkhead Footing Interior Footing Decks/ Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Plumbing Groundwork Mechanical Other Groundwork Gas Pipe Gas Piping Framing Mechanical Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Nailing Interior Wall Brace Panels Fire walls Other Final Building " Manuf. Home Setbacks Setup Concrete Foot/ Runners Final Other I NOIldIdOS3O SNOISA )l OM JO 3d00S `ON3O31 a31111 ONIMMO :103rod d LU W CD z W W J ♦— z Lv � 0" LJ SILENT KNIGHT DESCRIPTION SILENT KNIGHT N 0 O CD LC) O U w J CD v) N cfl HERBAN TREE FARMERS CC N U 0 E] N- N CC U CO SYSTEM SENSOR CC N 0_ O ram) N C H- O ELECTRICAL Q CD O) O N ACTUATION OF ANY MANUAL ALARM STATION, SPOT TYPE SMOKE, OR HEAT DETECTOR SHALL: Cn U 0 z Q W w CD W°°Lz U Z J7.2 co O LIJ CCQW CC W J J N W ¢ U Cl_ Li Z �W C/) zF- :2 vz LLJC� CI] C(J7 Ca_ >- a_ z wLU Lai = Z - w W 0 F- OUp CD Ei: 7,,E Cl_ 0 Q C/) CD (/) C) Lai F- Q w LU I-L 0 CD W CC O ¢ z W w z z0= c)0 w z w Q U ChfO C~/) LLJWCD p ¢ Q - z LU Clf Clf C%) C_) CL CD O U z m CC> w _ ¢ CD < U C J ¢ O CO J Q 0 W 0 0 z U iZ W ¢ U CDQ J > - z (L ¢ p " p_ZZ" C7 ¢ CC ELzw CL p W wo=QQE = Cr E-Li_ _J ~= --IW w FW- _ ¢ ¢ = Q F- z F- U Fw F O Z Z Z = Z z ¢ J O Z O U CY J J ¢(/)¢ 4 Ln CO N N N Ih N Q w Chf CD z 0 J m Z w F-- C/) La_ w U tY C/) W W Ch: U Z O U O F- O Lai CY F- U F— Cn 0 F- 0 w U N LCD N co N THE FACP LCD N N MONITORING STATION. w F— O F— J C) Cn W J 0 F— ¢ F= Cn Cr F-- CO N O7 N M r N rD M M r) N) U) CD W Z Z CD:I:Z Z 0 Z z~ ~ J O Q LU z mo �zo C/) ��oQ z �w o 0 p Ww W p C_) UOLi_O�mU 0= �W 0 U J g X W Z ¢�Li ¢m QDZ ZOZWD¢Z LLJ Cn0 (n QZ — OU C)UU) z Wm O m O W ¢ U ¢ W (l W C- _) C) 0 W OJ :: EC;) CnILz 00 J J J WZC>p JJZ_C�Q C� Z Q W JF- Z C/) ¢¢Z W C/)¢ U z¢ ZLz� Z¢ C�j-jZ UWZ�Z �J (n¢ ¢ O Lit wpUJ OcpLXW W O=a W W F— �¢ J� m� UJw6' -J Cam 0 CC/)L� �J QQ J JJ d� z �J ZLL_I Lai F- Z U)C) (n J==ZZ8 CD �(� Cn z U ¢ z QV)cn p w aQ z� �— U 1- L� J p Z (� Z two p¢ ww QF-�zO�p Q w0 CC ¢ p O F-W Z = J��O- F— C/) = C/) �¢p pO �� CCpQZ,Z z F-=LC j O Z O ppz JI� pLLI 0 pwZL�(nW CO LLJ m0p¢p U) 0 U �Q¢ W Z O� W .Q=� J __I J LaJ 0 O 0 Cl_ LIJ pW UZ ZWZZ�� ___I JZ= Z Z F— mUW �0 [Y0 0I-0=Li= < =QF- p [Y Zm w 0= _ �UOJ ~O w 8 = 2 JC~ mF- O~ �zNJ1-FW- C/) C3Clf W~ (rC��Z =�Q Jw Up �p~QCw/)z U zzZ W J Cn "_ ¢: ~C/) ¢ZO Q >C� LLJ�00 Z m J 0 w ¢ z (nZO� C=j)� Wp C/)��OFw-~ pz �UC� ¢ J ¢ W CD Q(Y W �� (� W �� C=J 0 < 00!!! C) C a Q= _�> ��it Lai CI: Lii Z zm ��__�� Zp L: rW OO Cn Z Z Lai OJ WOF-UC> W JOW W W CD J- m —'=m U= �m�5-¢0 aF- <0Q U) o F- ¢ 0�3 ¢F-0 ¢U) co ro Z 0 n- 0 0 W a J LL W Z �W V w F— w w 0 F- 0 w C) U w p W F- Cn Li 0 0 U ¢ CL w z F- z w m Cr U 0 w 0 O U NOTIFICATION APPLIANCES. AT THE EXITS. MANUAL PULLS NQ DETECTION THROUGHOUT. 0- 0 LI- J W Z LL J 0 LL F- Z 0 0 J Ui U- CC w 0 CL CL w CC O a U Z z z EVACUATION ALARMS: C/i z CC O w F— ›- CO 0 w U p O CL 0 z O Cl) z O U w >- p w p O CL Cn z O ¢ U W CD z p J Z m La_ O W C) F- 0 Z N) I w 0 O U J Cr O CZ 2E w F- 0 CC ¢ 0 Q C/) C/) z ¢ w C) Z U N � C co D_O W CJ1 n r' O O FAP O O D �co 0 Q £ N0021 213M013 I N CO 0 70 a N0021 213M033 N .3 O C ) •D O O D Lu O O N CO w CO n c0 Q- CJ1 D CO T —0 V N00N 213MO13 a Wes\ Dgco ©b�� II O m O Cb = 3AO9V 80011 aNz O r D Tx-0 \ O C 0 ✓ 0 C) C) C) VVUUd iJUi/\ 0 m 0 m 3NItNV IV(10 O N O N ONISS3O021d D Cr) O O CA rm N ON CJ7 D_0 Csl 33S — M0118 NddO I\V-1d 001J IS 1 N 00 m r 3Oa3/\ 3N01O D b N v 3Oa3A 3N013 c-) 1:0 U) 0 0 O U) D 0 m 0 Fri n 0 D = z m 70 771 O m 0 0 co m p.i 380d1S a31NflOW ON11130 CEILING MOUNTED HORN/STROBE NOIIVIS 13f1d 318VSS3dGOV O NO1O313a 1V3H 338VSS3daaV d010313a 1>IOINS 318VSS3dGGV NOIVI3Nf1NNV 3101Al3d V VIV 3d13 13NVd 1ONlN00 Wdvf1V 3d13 CD 0 CT) PROJECT: DRAWING TITLE: 1ST FLOOR FIRE ALARM REVISIONS NO. DATE DESCRIPTION 1 8/23/17 SUBMITTAL iviim8 f S Jl8 NOI1dI I3S30 31V0 '0N SNOlSIn�� mow] IO d3SIN1 :31111 9NIMd210 :103r0Nd Lu Cri 0 m FIRE ALARM CONTROL PANEL 0 ADDRESSABLE SMOKE DETECTOR ADDRESSABLE HEAT DETECTOR ADDRESSABLE PULL STATION CEILING MOUNTED HORN/STROBE CEILING MOUNTED STROBE WEATHERPROOF HORN/STROBE O CD J I..' N E \° co W CC CL Cl) CL U 1 J N Q PO U n • REMOTE ANNUNCIATOR PHONE LINE #2 1bllI 8flS NOIldIdOS3a SNOISIA :1 INV21OVIO ONI lM :31111 9NIMVd :133rald w TYPICAL TWO PHONE LINE CONNECTION W U_ W 02Emc r 54Th CC9A3-61Ge SB SA S+ S- G) m m m C!) m CT) m < + I J >— W —TROUBLE RELAY Ol �U z U z z N 01 U z z U z U ONIdIM unallO NOLVOIdIlON 1VOld,ll N rr) Q Q Q Z z Z ± I ± I ± ,Z1. (I]> [> V C2 CDw = 1a a 0 0 0 p V Ire �u3 Q , ,z4 I g oa g Q 0 0 lIflO IIO dOlbIONflNNd TYPICAL WIRING TO REMOTE ANNUNCIATOR 5860R V I rn r No r\ (A\ (2) (;=,,r 1. Confirm all supervisory signals are received by the FACP. 2. Fire Pump testing shall be in accordance with NFPA 25. Indicating Devices: O Devices are located according to approved plans. ❑ Adequate sound pressure is obtained according to NFPA 72. Center of room 4.5' from any hard surface. ❑ In areas with doors and no devices located in the room, doors shall be closed to obtain sound pressure rating. 75db1 ❑ Ensure pre-recorded messages are multi lingual if needed. Devices in the same field of view shall be synchronized. Elevator Recall: ❑ Shall be conducted in conjunction with WA State L&I and Elevator Contractor. ❑ Confirm that the elevator returns to the primary recall floor. ❑ Confirm that the elevator returns to the alternate floor. ❑ WA State L&I inspection completion form will be accepted by AHJ. Door Controls: o Confirm proper installation. ❑ Confirm that doors shut with AC power failure of that the doors are included in the battery calculations. o Test all devices with approved method. Documentation: 4.5.2.3 o Record of completion form. o Copies of the NFPA Inspection and Testing form or WA State Fire Marshal System completion form. o Copies of the As -Builds, Acceptance Forms, System Manual, and Programming shall be left onsite in a permanent file in the FACP room. Before you begin the alarm test ❑ Find approved plans ❑ Compare to any modifications ❑ Ask for a completed test and inspect document ❑ Verify UL listed central station ❑ Verify 4.5.1.2 Written statement that the system has been installed with approved plans ❑ Record of completion form should be competed. Alarm System Acceptance Procedure General: ❑ Approved plans on site? ❑ Have building occupants be informed of the test? ❑ Has the central station be notified? Start time and end time of test. o All parties have been informed of test and are present. Elevator, IT, Mechanical, ect. ❑ Any modifications to the plans, if so verify. ❑ Completed testing document from WA State Fire Marshals Office or NFPA 4.5.1.3 o Is the person (s) performing the test qualified to perform the test. 10.2.2.5.1 ❑ Battery terminal removed to show trouble ❑ AC power removed to show trouble ❑ Phone and/or communication removed to show trouble ❑ NAC circuit removed to show trouble ❑ All trouble signals are received within 200 seconds ❑ AC power circuit labeled as to location O AC circuit locked ❑ 10% of devices checked for trouble if removed per circuit. ❑ Verify that the zones and rooms associated with are correct. o All devices worked as listed to operate. O Signals are re -sounded after silenced. Smoke Detectors: ❑ Not installed within 12" of wall and ceiling devices unless listed ❑ Not installed within 3' of air diffuser or fans ❑ Not installed in kitchens, bathrooms, smoking lounges, incinerator rooms. ❑ Installed within 21' of FACP panel. May be omitted if fully sprinklered ❑ Use approved testing device to activate the detector. o Multi detectors shall be tested individually if dual output. Duct Detectors: ❑ Confirm proper installation. ❑ Initiate each detector using approved testing procedure. Magnetic test are not approved. ❑ Documentation from Mechanical Contractor that proves differential pressure between the exhaust and sampling tubes shall be provided. Heat Detectors: ❑ Activate all devices using an approved method. ❑ Confirm proper installation. Air Sampling Devices: ❑ Confirm proper installation. ❑ Activated all devices using an approved method. o Alarm response within 120 seconds. ❑ Verify air flow from all ports. Projected Beam Smoke Detectors: ❑ Confirm proper installation. ❑ Confirm line of sight is clear from obstructions. ❑ Activate every projected beam detector using the filter kit provided by manufacture, or approved method. Initiating Devices for Sprinkler Systems: ❑ Sprinkler devices shall be tested with appropriate contractors onsite. ❑ Devices are installed per approved plans. ❑ Devices shall be tested using approved methods, shorting contacts is not accepted. Department of Labor and Industries INTELLISYSTEMS INC PO Box 44460 Olympia, WA 98504-4460 Lic: EC INTELI*982MQ UBI: 602-220-384 Licensed as provided by Law as: Electrical Contractor (EC06)-LIMITED ENERGY 550 (EC6A) -HVAC/RFRG INTELLISYSTEMS INC PO BOX 592 Effective Date: 7/18/2002 PORT ORCHARD WA 98366 Expiration Date: 7/24/2018 FIRE MARSHAL MUST MEET ALL CURRENT Ti ES'-- 1=r WASHINGTON STATE CODES ON I I IL JOa SITF Y 4. SYSTEM DATA SUBMITTAL MANUAL for BERBAN TREE FARMERS FIRE DETECTION & ALARM SYSTEM Prepared by INTELLISYSTEMS, INC. P.O. BOX 592 PORT ORCHARD, WA 98366 . INTELLISYSTEMS, INC. SYSTEM DATA SUBMITTAL MANUAL for BERBAN TREE FARMERS FIRE DETECTION & ALARM SYSTEMS TABLE OF CONTENTS SECTION 1 DESCRIPTION& SEQUENCE OF OPERATION SECTION 2 EQUIPMENT DATA SHEETS SECTION 3 STANDBY BATTERY CALCULATIONS SECTION 4 SYSTEM DRAWINGS INTELLISYSTEMS, INC. SECTION I DESCRIPTION & SEQUENCE OF OPERATION INTELLISYSTEMS, INC. INTELLISYSTEMS HERBAN TREE FARMERS Section 1 Fire Alarm Systems Data Submittal Manual Page 1 SCOPE OF WORK— GENERAL The fire alarm system shall consist of the following primary elements to provide fire detection, alarm and evacuation annunciation capabilities for the Herban Tree Farmers as indicated on the system plans. A. Addressable fire alarm control panel located in the fire sprinkler room. B. Full coverage detection. C. Evacuation alarms (horn-strobes & strobes) located throughout the tenant space. D. Pull stations at all exterior exits. E. Remote annunciation at the entrance. INTELLISYSTEMS, INC. INTELLISYSTEMS HERBAN TREE FARMERS Section 1 Fire Alarm Systems Data Submittal Manual Page 2 SYSTEM SEQUENCE OF OPERATION FIRE ALARM SYSTEM: 1. ALARM CONDITIONS: 1.1 ACTIVATION OF ANY CEILING MOUNTED SMOKE DETECTOR, OR HEAT DETECTOR SHALL CAUSE THE FOLLOWING TO OCCUR: A. ILLUMINATE THE RED "ALARM" INDICATOR ON THE FACP. B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING LOCATION INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. C. ACTIVATE EVACUATION ALARM HORN-STROBE UNITS IN THE AFFECTED BUILDING. D. TRANSMIT AN "ALARM" SIGNAL TO REMOTE MONITORING STATION. 1.2 ACTIVATION OF ANY MANUAL STATION SHALL CAUSE THE FOLLOWING TO OCCUR: A. ILLUMINATE THE RED "ALARM" INDICATOR ON THE FACP. B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING LOCATION INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. C. ACTIVATE EVACUATION ALARM HORN-STROBE UNITS IN THE AFFECTED BUILDING. D. TRANSMIT AN "ALARM" SIGNAL TO REMOTE MONITORING STATION. 2. FAULT/TROUBLE CONDITIONS: 2.1 CONDITIONS IN THE SYSTEM THAT MAY CAUSE FAILURE, OR IMPAIR OPERATION OF THE SYSTEM SHALL CAUSE THE FOLLOWING: a. CAUSE THE TROUBLE INDICATOR LAMP ON THE FACP TO ILLUMINATE. b. CAUSE THE INTERNAL SOUNDER DEVICE IN THE FACP TO ACTIVATE. c. DISPLAY PROPER MESSAGE ON FACP LCD DISPLAY WITH TROUBLE LOCATION INFORMATION. d. TRANSMIT A TROUBLE SIGNAL TO MONITORING STATION THE FOLLOWING IS AN ABBREVIATED LIST OF THE TYPES OF FAULTS THAT WILL CAUSE A TROUBLE CONDITION TO REPORT TO THE FACP. a. ACTIVATION OF ANY PANEL "BYPASS" OR "OVERRIDE" FUNCTION. b. OPEN, SHORTED OR GROUNDED WIRING ON ANY DETECTION CIRCUIT. c. OPEN, SHORTED OR GROUNDED WIRING ON ANY MANUAL CIRCUIT. d. ANY MISSING OR REMOVED DEVICE SUCH AS POINT MONITORING MODULES OR MANUAL STATIONS. e. OPEN, SHORTED OR GROUNDED WIRING ON ANY NAC (HORN/STROBE) CIRCUIT. f. CONTROL PANEL STAND-BY BATTERY FAULT. g. LOSS OF PRIMARY 120 VAC POWER TO THE FIRE ALARM CONTROL PANEL. INTELLISYSTEMS, INC. SECTION 2 EQUIPMENT DATA SHEETS INTELLISYSTEMS, INC. INTELLIKNIGHT FIRE ALARM CONTROLPANEL SILENT IntelliKnight° 5808 KNIGHT Single Loop Addressable Fire Alarm Control System by Honeywell The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 supports SD or SK protocol devices. 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built-in support for up to 99 SK detectors and 99 SK modules. • Built in support for 127 SD devices. • Up to 125 zones and 125 output groups. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator. Model 5808 • Central station reporting by point or by zone Plex-2 door option combines a dead front • Supports Class B (Style 4) and Class A(Style 6 or 7) cabinet door with a clear window, limiting configuration for SLC. access to the panel while providing single • Distributed, intelligent power. button operation of the reset and silence • Drift compensation. functions. • 13 pre-programmed output cadences, (including ANSI- Integrated dead front panel protects operator 3.41), and 4 programmable outputs. from exposure to electrical components. • Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for The FACP enclosure features a Plexiglass® resettable, constant, or door holder power. viewing window to protect annunciator. • Built-in annunciator with 80-character LCD display. Acknowledge function allows operator to keep • RS-485 bus provides communication to system track of event status. accessories. • Built-in RS-232 and USB interface for programming Installation via a PC. The 5800 can be surface or flush mounted. • Upload or download programming, event history, or Compatibility detector status via remote or direct connection. • Improvements in SKSS deliver five times faster The 5808 signal line circuit (SLC) supports upload/downloads. multiple device types of the same protocol: • Built-in synchronization for appliances from AMSECO, • SK GentexO, Faraday, System Sensor®, and Wheelock®- • SD • One Form C trouble relay rated at 2.5A at 27.4 VDC and You cannot mix SD and SK SLC devices on a two Form C programmable relays rated at 2.5A at 27.4 FACR VDC. CONTROLINTELLIKNIGHT FIRE ALARM PANEL I I I eea.ars, oet'.=� extane.. emee noew exiev ena. e.wna lu-gym se���ra� """',�""," �aaaay. w�"aa. sw�:�xa ea$ so�,.x o�. use,: puma: I manse Moms 5496 RD 5808 Specifications Protected Premises Unit; &Water Deluge Miscellaneous Accessories Electrical Releasing Service. Suitable for automatic, 5660 Silent Knight Software Suite Prima AC: 120 VRMS at 50/60 Hz, manual, waterflow, sprinkler supervisory Primary (DACT non-coded)signalling services. PC-base software for FACP 2.75A UL Listed programming. Upload and view panel Total Accessory Load: 6A @ 27.4 CSFM 7165-0559:0142; account information, event history, and VDC MEA 429-92-E Vol.XIV detector status. Notification Power: 6A @ 27.4 VDC, OSHPD (CA)OSP-0065-10 5670 Silent Knight Software Suite power-limited End-user facility management software Standby Current: 170 mA S-BUS Accessories allows viewing of detector status and Alarm Current: 365 mA 5860/R Remote Fire Annunciator event history via modem or direct Notification &Auxiliary Circuits: Features the same 80 character backlit connection. 3A @ 27.4 VDC per circuit,power- LCD display keypad and firefighter's key limited switch as the 5808. 5860 is gray and Plex-2 Door Battery Charging Capacity: 5860R is red. Dead front cabinet door with clear 7.0-35 AH 5496 Intelligent Power Module window to limit access to the FACP. Battery Size: 18 AH max. allowed in A 6 amp notification power expander that RBB FACP. Larger capacity batteries can provides four additional power-limited Remote Battery Box Accessory be housed in an RBB accessory notification appliance circuit outputs. Cabinet. Use if backup batteries are cabinet too large to fit into FACP cabinet. 5880 LED/10 Module Dimensions: 16"W x 10"H x 6"D Physical Features 40 LED outputs, 8 normally open (406 mm W x 254 mm H x 152 mm D) Flush Mount Dimensions: dry contact inputs and one piezo output. 14.5"W x 24.75" H x 3.5" D SK-SCK (36.8 W x 62.9 H x 8.73 D cm) 5865-3 and 5865-4 Seismic Compliance Kit Remote LED Annunciator Overall Dimensions: Features 30 programmable LED (15 red SD and SK Devices 16"W x 26.4" H x 4.65" D and 15 yellow)outputs and a piezo See the specification sheets listed (40.6 W x 67 H x 11.8 D cm) sounder.The 5865-4 adds a silence and below for a complete listing of the SD Weight: 28 lbs. (12.8 kg) reset switch to the package. and SK devices. Color: Red 5824 Serial/Parallel Printer 53624 SD Devices data sheet Telephone Requirements: Interface Module 53623 SK Devices data sheet FCC Part 15 and Part 68 approved Provides one parallel and one RS-232 Type of Jack: RJ31 X(two required) serial port for connecting a printer to 5808. Approvals Use to print a real-time log of system NFPA 13, NFPA 15, NFPA 16, NFPA events,detector status reports, and event 70, & NFPA 72: Central Station; history. Remote Signalling; Local Protective 5883 Relay Board IntelliKnight&JumpStart are Registered Signalling Systems;Auxiliary Features 10 general purpose Form C Trademarks of Silent Knight Flexput is a relays. Used with 5880 module. Trademark of Silent Knight SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all 13.KNIGHT specific applications or anticipate all requirements.All specifications are 350386 Rev.L subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610. Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support,Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description multiple 5860s Features include an 80-character • RS-485 interface to panel backlit LCD providing easy-to- • Operation and appearance is understand system messages. The identical to 5860 built-in annunciator is ergonomically annunciator designed with over-sized buttons • On-board piezo sounder audibly for the most frequently used indicates alarms, troubles, and features, like Reset and Silence. supervisories In addition to status messages • Five status LEDs for alarm, supervisory, trouble, silence and displayed on the LCD, there are AC power conditions five LEDs for alarm, supervisory, . Wiring lengths up to 6000 ft. from trouble, silence, and AC power the FACP (depending on wire status. gauge and number of devices on 5860 The annunciator is available in gray SBUS) Environmental to match virtually any decor and • UL listed, complies with NFPA 72 Operating Temperature: 320F— red for applications where the • CSFM approved 120°F (0°C—49°C) annunciator must stand out. The Electrical Specifications Humidity: 10%—93% non- annunciator enclosure can be Operating Voltage: 24 VDC condensing surface or flush mounted.A trim Standby Current: 20 mA max Compatibility ring kit is available for surface The 5860 is compatible with the mounting. Alarm Current: 25 mA p Wiring Distance: 6,000 max. from following FACP's: Features FACP (depending on wire gauge • 5820XL Addressable Fire Control • 80-character backlit LCD display and number of devices on the Panel (4 lines with 20 characters on SBUS) • 5820XL-EVS FACP with each line) Emergency Voice System • Tactile and audible feedback Max Per System: 8 • 5808 Addressable Fire Control • Accepts user codes or fire Mechanical Specifications Panel fighter's key Physical 9.1"W x 7.4" H x 1.5" D . 5700 Addressable Fire Control • Larger keypad buttons for system (23.1 W x 18.8 H x 3.8 D cm) Panel reset and silence Shipping Weight: 2.8 Ibs (1.3 kg) Listings • Install up to eight 5860s per FACP Color NFPA 72; UL Listed; • Available in red or light gray 5860R: Red CSFM 7170-0559: 135; • Support for simultaneous use of 5860: Gray MEA 429-92-E Vol. IX; FM Approved INTELLIKNIGHT O. 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals.The control panel must allow all annunciators to accommodate multiple user input simultaneously. VYIrlr KWN DP to$00 f OrMM JFACP vim 9BUIS 4-In i j Up to cap!SWa Pet Syi0cm Cainlaeilwle leatthlKiliR41 fACP Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350224 Rev F subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610.Phone: (800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT SD500-PS and SD500-PSDA KNIGHT Addressable Pull-Station by Honeywell IntelliKnight's addressable pull stations combine fast response with pin-point location ID The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight- easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Addressable Pull • Terminals -accept up to 14 Station gauge wire • Extremely easy to operate SD500-PS & SD500-PSDA • Corrosion-resistant gold-plated The SD500-PS is a single action contacts. addressable fire pull station, and • Reflective label makes it easier the SD500--PSDA is a dual action to locate in low light addressable fire pull station. The Operation SD500-PS/PSDA feature rugged metal construction A terminal strip The SD500-PS/PSDA single action on back of the pull station allows pull stations are operated by a pull interconnection of the pull station to on the front pull cover of the the SLC of an IntelliKnight control station. A plunger switch, wired to panel. The SD500-PS/PSDA is a self contained addressable designed for indoor use in non- module, is released as the pull explosive environments. The station opens to initiate the alarm. normally open initiating point Once operated, the cover hangs contacts are gold-plated to avoid down and can be seen up to 100 risk of corrosion. The SD500- feet away. The pull station is reset PS/PSDA has been tested by UL by returning the front cover to the for compliance to the requirements normal upright position and of the Americans with Disabilities relocking the station with a reset ACT(ADA). key. The reset keys are the same keys used on Silent Knight SD500-PS Features enclosures. Specifications • UL Listed The SD500-PS/PSDA includes a status LED which blinks, indicatingOperating Voltage: 24VDC w • CSFM listed Standby Current: .55mA • MEA(SD500-PS only) that the addressable module is Y 429-92-E Vol XI communicating with the loop. The Alarm Current: .55mA status LED lights continuously Ambient Temperature: • ADA compliant during an alarm.A dip switch on 32°F to 120' (0°C to 49°C) • Key reset (Same key as Silent the addressable module is used to Knight enclosures) set the unique address. Mounting: Single gang box • Surface mount back box PS-SMBB - Optional Red Surface availableMount Box I O. SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. O m O Class a(Sty14) , Class A(Style B) N P9 N9 I- tJ \ _ . sonasne __ft nerelumside t, fl rl \\ o o Il6tl^IUIII ,*0t O 11 m\ m 11 p \ \� o �s o Wiring 0 0 (��p a 3" 2.1/2" Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box 5-1l16" SD500-PSDA 1-LI Electrical Box must be Installing SD500-LK at least 1-1/2"Deep Dimensions L3SILENT This document is not intended to be used for installation purposes.We try to Assembled in USA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are P/N 350342 Rev.D subject to change without notice.For more information,contact Silent Knight by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, ©2011 Honeywell International Inc. Fax:(203)484-7118. www.silentknight.com I ACCESSORYINTELLIKNIGHT Addressable Photoelectric Type z Smoke Detector F Detect smoldering fires quickly and get 2 help fast with IntelliKnight® photoelectric +iGlr °R smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog /Addressable an electronic signal. Under normal - ~� Photoelectric Type conditions, the status LED blinks \ \ Smoke Detector approximately every 15 seconds, The SD505-APS is particularly indicating that the head is , suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. foam or other similar materials Features which tend to smolder and produce . Low profile, 2 inches, including SD505-APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17-41 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the . Built-in fire test feature Alarm: .55 mA WindowsTM based downloading . Simple detector calibration Ambient Temperature:32°F to 120°F software). testing through the control panel (01 C to 49 C) Operation or remotely through a Mounting: 4" Square,4" The SD505-APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a - Vandal-resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable Air Velocity: 0- 300 FPM from the pulsing light source. In the . UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the Compatible Bases: SD505-6AB detector and light is reflected from requirements (Sold Separately) (6" Base) the smoke particles to the receiving ' CSFM approved SD5054AB element. • MEA approved (4" Base) • FM Approved SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector I Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. N Diameter 5-15116" Diameter=3-15116" 0 oe . \3 1 0 o Height=2 inches, �, including base SRBN'f O Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350225 Rev C,.05/05 subject to change without notice. For more information,contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone:(800)328-0103,Fax:(763)493-6475. INTELLIKNIGHT ACCESSORY SILENT SD505-AHS KNIGHT Addressable Heat Detector 0 by Honeywell IntelliKnight® addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-AHS If the temperature exceeds the trip Addressable Heat point (programmed at the panel), an alarm occurs. The status LED Detector lights continuously during the alarm The SD505-AHS is a heat detector period. c suited to virtually any commercial Under normal conditions, the status r setting. The SD505-AHS is an LED blinks approximately every 15 absolute temperature device. This seconds, indicating that the head is means that it responds in alarm if communicating with the loop. the temperature goes above the trip point (programmed at the Features panel). • Low profile, 2 inches, including The SD505-AHS provides accurate base SD505-AHS Heat Detector temperature measurement data to • Absolute temperature device Specifications the fire alarm control panel. This . Simple and reliable addressing Operating Voltage: 17 to 41 VDC heat detector is particularly suited Current Consumption: to environments where smoke Uses digital communication detectors cannot be used because protocol Standby: .55 mA of the presence of steam or • The SD505-AHS is UL Listed Alarm: 55 mA cooking fumes, such as in a and meets the requirements Detection Temperature kitchen. outlined in NFPA 72 Inspection Range: 135°F to 150°F Testing and Maintenance, (57°C TO 65°C) Operation Chapter 7. Ambient Temperature: 32°F to 120°F The SD505-AHS unit is made up of • CFSM listed (o°C to 49°C) an externally mounted thermistor Mounting: 4"SQR,4"OCT with a specially designed cover that MEA listed Single gang mud p y g ring protects the thermistor while • FM approved allowing maximum air flow. The Rated Spacing: 70'between sensors thermistor reads the temperature ceilings.on smooth from the air it takes in. It then transmits a signal representing the Compatible Bases: SD505-6AB B temperature to the IntelliKnight (Sold Separately) SD505-6 B panel. SD505-6RB INTELLIKNIGHT ACCESSORY Model SD505-AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB. The heat detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Diameter= 5-15/16" Diameter= 3-15/16" 0 0 �QP o =o Height=2 inches, 0 ( ����� f� including base o O iavccxT Model SD505-6AB Detector Base Model SD505-AHS Detector Head (Front View) (Front View) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350229 Rev C subject to change without notice. For more information,contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. www.silentknight.com SYSTEM �� SENSOR® Indoor Selectable- Output Strobes and Horn Strobes for Z4 -4: Ceiling Applications 3 SpectrkertO Advance audible visible notification products 3a�� are rich with features guaranteed to cut installation times SPECTRAfe and maximize profits. I ■�� E Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at 15 and can meet virtually any application requirement. 15/75 candela • Field-selectable candela settings on ceiling units: 15,15r75,30, Like the entire SpectrAlert Advance product line,ceiling-mount 75,95, 110, 115, 135, 150,177,and 185 strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for ceiling units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ,.Ot UL F M •:' MEA LISTED APPROVED approved 7125-1653186(indoor strobes) 7125-1653.188(horn strobes, S4011(chimes,horn strobes,horns) 3023572 M_A452-05-E chime strobes) S5512(strobes) 7136-1653.189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 1'/.—inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110,115,135, 150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS, 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) TRCW-HS) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P.S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15f75 15 15f75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 Strobe,UL Max.Current Draw(mA RMS),2-Wire Horn 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 • 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. AVDS00501 SpectrAlert Advance Dimensions 7.1" I 2.25 6.8" ia. Dia. O 2.5" +iI o Ceiling-mount horn strobes Ceiling back box skirt SpectrAlert Advance Ordering Information DescriptionModel Description Model Ceiling Horn Strobes Ceiling Strobes PC2R* 2-Wire Horn Strobe,Standard cd,Red SCR Strobe,Standard cd,Red PC2RH 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White PC2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red Accessories PC4RH 4-Wire Horn Strobe,High cd,Red BBSC-2 Back Box Skirt,Ceiling,Red PC4W 4-Wire Horn Strobe,Standard cd,White Back Box Skirt,Ceiling,White TRC-HS Trim Ring,Ceiling,Red TRCW- Trim Ring,Ceiling,White HS Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P213-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. t"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. SYSTE ®2012 System Sensor. M 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR* Phone:800-SENSOR2•Fax:630-377-6495 f«current product information,AVDS00501-elatest version of this data sheet. 3/12 SYSTEM �4 SENSOR® =_ F F R R Indoor Selectable- Output Horns, Strobes, and y� Horn Strobes for Wall Applications �,• SpectrAlert@ Advance audible visible notification products SPECTRert are rich with features guaranteed to cut installation times ,4 o If ,tt N c E and maximize profits. Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela • Field-selectable candela settings on wall units: 15, 15/75, Like the entire SpectrAlert Advance product line,wall-mount horns, 30,75,95, 110, 115, 135, 150, 177,and 185 strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING @ F M > MEA LISTED APPnoveo approved 7125-1653:186(indoor strobes) 7125-1 653:1 88(horn strobes, 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) • 55512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 1'h-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the SynceCircuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the SynceCircuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, 110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor SynceCircuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21B-inch back box.The module shall also control two Style Y(class 8)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7-L x 4.8-W x 0.35-D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Its 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 4.7-- 2.5" 5.6" Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe,High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Homs P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 02014 System Sensor. SENSORa Phone:800 SENSOR2•Fax:630 377-6495 Product wrrent Prod fions subormabt to changng the latest ce.m Visits this data sorcorn heet. for current product information,including the latest version d this data sheet. www.systemsensor.com AVDS10201.1/14 SYSTEM SENSOR Outdoor Selectable- . Output Horns, Strobes, and Horn Strobes SpectrAlert'Advance outdoor selectable-output horns, strobes,and horn strobes are rich with features that �y cut installation times and maximize profits. SPECTRAiert 46 Features The SpectrAlert Advance series offers the broadest line of •Automatic selection of 12-or 24-volt operation at 15 and 15/75 outdoor horns,strobes,and horn strobes in the industry.With candela white and red plastic housings,wall and ceiling mounting options, •Field-selectable candela settings on wall and ceiling units:15,15/75, and plain and FIRE-printed devices,SpectrAlert Advance can meet 30,75,95,110,115,135,150,177,and 185 virtually any application requirement. •Plug-in design with minimal intrusion into the back box SpectrAlert Advance outdoor horns,strobes,and horn strobes can -Tamper-resistant construction be used indoors or outdoors in wet or dry applications,and can •Universal mounting plate for wall-and ceiling-mount units provide reliable operation from—40°F to 151°F. •Mounting plate shorting spring tests wiring continuity before Like the entire SpectrAlert Advance product line,these devices devices are installed include a variety of features that increase their application versatility •Weatherproof per NEMA 4X,IP56 while simplifying installation.All devices feature plug-in designs with •Listed to UL 1638(strobe)and UL 464(horn) minimal intrusion into the back box,which make installations fast •Rated from—40°F to 151°F and foolproof while virtually eliminating costly and time-consuming •Horn rated at 88+dBA at 16 volts ground faults. •Rotary switch for horn tone and three volume selections All horns,strobes,and horn strobes use a universal mounting plate •Compatible with System Sensor synchronization protocol and with an onboard shorting spring that tests wiring continuity before legacy SpectrAlert products the device is installed,protecting devices from damage.In addition, field-selectable candela settings,automatic selection of 12-or 24- volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING LISTED F nn MEA 73001653:187(outdoo strobes) roved 7125-1653:188(hom strobes, S4011(chimes,horn strobes,horns) APPROVES approved chime strobes) S3S93(outdow and alert strobes) 3023572 MEA452-OS-E 7135-1653:189(horn;chimes) SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts,24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,1 IQ 115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobes entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobes entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in orderto remain outdoor approved per UL.The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(fi0°C to 66"C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 175 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions(SA-WBBC) 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0456-002 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non Temporal High 57 56 69 75 95 NA NA 181 176 Non Temporal Medium 42 50 60 69 110 NA NA 202 195 Non Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(1 S-1 15 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela Horn and Horn Strobe Output ratings must be reduced in accordance with this table. 24 Volt Nominal Strobe Output 8-17.5 16-33 Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non Temporal High 82 82 88 88 93 92 100 100 95 70 5 Non Temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non Temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8t Coded Medium 78 78 85 85 90 90 97 98 150 150 9t Coded Low 75 75 81 81 88 85 96 92 177 177 tSettings 7,8,and 9 are not available on 2-wire horn strobe. 185 185 A05-0456-002 SpectrAlert Advance Dimensions i.-4.7' 2.5' _ 6.8' Dia. TN 5.6 Wall-mount horn strobes Ceiling-mount horn strobes 7.1- 2.0' Dia. o y O AD eo � _ o y 5.7- 0 o O O O �.1—mil Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Horn Strobes P2RK"t 2-Wire Horn Strobe,Standard cd,Red,Outdoor PC2RK 2-Wire Horn Strobe,Standard cd,Red,Outdoor P2RHK"1 2-Wire Horn Strobe,High cd,Red,Outdoor PC2RHK 2-Wire Horn Strobe,High cd,Red,Outdoor P2WK't 2-Wire Horn Strobe,Standard cd,White,Outdoor PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor P2WHK"t 2-Wire Horn Strobe,High cd,White,Outdoor PC2WHK 2-Wire,Horn Strobe High cd,White,Outdoor P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor PC4WK 4-Wire,Horn Strobe,Standard cd,White,Outdoor P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor PC4WHK 4-Wire,Horn Strobe,High cd,White,Outdoor P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120V Ceiling Strobes Wall Strobes SCRK Strobe,Standard cd,Red,Outdoor SRK"t Strobe,Standard cd,Red,Outdoor SCRHK Strobe,High cd,Red,Outdoor SRHK"t Strobe,High cd,Red,Outdoor SCWK Strobe,Standard cd,White,Outdoor SWK"t Strobe,Standard cd,White,Outdoor SCWHK Strobe,High cd,White,Outdoor SWHK"t Strobe,High cd,White,Outdoor Horns HRK Horn,Red,Outdoor Notes: Add'-P'to model number for plain housing(no'FIRE'marking on cover),e.g.,P2RK-P. t Add'-R'to model number for weatherproof replacement device(no back box Included),only for use with weatherproof outdoor flush mounting plate,W1P and WTPW. 'Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd'refers to strobes that Include 135,150,177,and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 Products ozoov system sun:«. SENSORa ntproduct rodbtinfor atttodangewttharcnotkevsit rsimofthKdensheel, « Phone: Fax:630-377-6495 curtentp odu tinf«matbry56-00-the latest92version of hsdaasheet . nos-oast-ooz•t vos•rzzss SECTION 3 CALCULATIONS: STANDBY BATTERY INTELLISYSTEMS, INC. SILENT Global Project Values: Project Name:I Herban Tree Farmers Standby Hours:KNIGHT 24 Project ID: 110586 Alarm Mins:93 O Prepared By:lintellisystems Derating Factor: 1.2 Calculations5808 Date: 8/25/2017 1 Voltage Drop Warning Version10.24.14Threshold%: 10 Panel ID: 15808 Model: 5808 Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: Office Volts: 24 VDC Max Panel Current: 5.0 Amps Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 5808 5808 CTRL Panel 1 1 0.170 1 0.365 SD500-AIM Addr. Input Mod 0.000 0.000 SD500-MIM Mini-Input Module 0.000 0.000 SD500-ARM Addr.Relay Module 0.000 0.000 SD500-PS Addr. Pull Station 2 0.001 0.001 SD505-AIS Addr.Ion Smoke Det 0.000 0.000 SD505-AHS Addr. Heat Detector 14 0.008 0.008 SD505-APS Addr.Photo Smoke Det 11 0.006 0.006 SD505-DUCTR Addr.Duct w/Relay 0.000 0.000 SD505-DUCT Addr.Duct 0.000 0.000 SD500-ANM Addr. Notification Module 0.000 0.000 SD500-LED Addr.LED Module 0.000 0.000 SD500-SDM Addr.Smoke Det.Mod. 0.000 0.000 SD505-6RB Addr. Det.Relay Base 0.000 0.000 SD505-6SB Addr.Det.Sounder Base 0.000 0.000 SD505-61B Addr. Det. Isolator Base 0.000 0.000 SD500-LIM Line Isolation Module 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator(4G) 0.000 0.000 5865-3 LED Annunciator(3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 NAC#1 Notification Appl Circuit 0.000 0.893 #14 Solid 2.52 1 171 0.86 19.63 3.77% NAC#2 Notification Appl Circuit 0.000 1 0.555 #14 Solid 2.52 124 0.62 20.05 1.70% NAC#3 AUX PWR 0.250 0.610 #14 Solid 2.52 146 0.74 19.95 2.20% NAC#4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Total Standby Current(Amps) 0.455 2.463 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins) Total Standby AH Required 10.916 0.205 Total Alarm AH Required Total Combined AH Required 11.12 Command Shortcuts Multiply By The Derating Factor 1.20 l 1 Minimum Battery AmpHours Required 13.35 Configure Circuits J Print Page J pR°v�O SNP` G 8 NSP RORs All CURR'E� MUST MEET STATE GOES INGTON 59-a \GPSS�NSO oN�RP� pNS�P�pPR°vP� WASN P P� °RAM kE5�C �NSP� E?N\S R\GNA p,N \v°F MF\E\� EyPENs . 41kv \N S. g\8\L�\RE�FR Rp G�ORS V pERs° PEE�GRPN,\l G °RS °Es tE v\0�' SECTION 4 1 SYSTEM DRAWINGS Note: If reduced size drawings are not present in this section,then full size drawings have been furnished attached or separately. INTELLISMEMS INC. I I MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT FIRE MARSHAL Mason County Bldg. III, 426 West Cedar Street, Shelton, WA 98584 www.co.mason.wa.us Shelton (360)427-9670 Belfair(360)275-4467 Elma(360)482-5269 September 110'2017 Fire Marshal Notes: Permit:FIR2017-00027 Name:Ranch Drive LLC Phone:IntelliSystems 360-895-7995 • Alarm acceptance form attached. Please ensure that everything is completed prior to calling for final inspection. • Ensure that keys for alarm system are provided for KNOX Box. • Install Per NFPA 72. • Approved plans must be onsite at all times and kept at the Fire Alarm Panel. • Identify FACP circuit breaker in FACP and provide for FACP A/C lock out. • Label batteries with month and date placed in-service • Provide all staff and equipment to conduct acceptance testing. • Provide EOL access during acceptance test. • All plans are subject to field inspections,inspector revisions may be made to obtain compliance. • Exterior horn/strobe to face roadway. • Final Fire Marshal inspection will be required prior to Building Department Final. • Provide Washington State Fire Marshals Acceptance forms upon Final. • Provide NFPA 72 acceptance paperwork at time of final. Plan approval does not relieve the designer/contractor from complying with all applicable codes and requirements as adopted by Mason County and the State of Washington, not does it abrogate the requirements of the requirements of other authorities having jurisdiction. F ARE Reviewe,, �4 S�A 110